YASKAWA SGM-A3, SGM-01, SGM-02, SGM-03, SGM-04 User Manual

...
Series SGM/SGMP/DR2
USER'S MANUAL
AC Servomotors and Driver
SGM/SGMP Servomotors DR2 Servopack
YASKAWA
YA S K A WA
MANUAL NO. TSE-S800-17D
PREFACE
The rapid progress being made in today’s automation and information technologies is resulting in a growing need for even more-advanced motion control for future high-tech equipment. The end result is a need for devices that can provide more-precise and quicker motion at higher speeds. Servo control technology makes this possible. Launched by Yaskawa in 1993, the Σ Series consists of innovative AC Servos that were developed using leading-edge servo control technology.
This manual covers all products information on the Σ Series SGM j/DR2, which feature superior functions and performance. This manual was designed to provide comprehensible information for users who are about to use a servo for the first time as well as for users who already have experience in using servos. This manual enables users to understand what Σ-Series AC Servos are all about and how to design, install, operate, and maintain a servo system. Keep this manual in a convenient location and refer to it whenever necessary in operating and maintaining the servo system.
YASKAWA ELECTRIC CORPORATION
General Precautions
S Some drawings in thismanual are shownwith the protectivecover or shields removed, in order to
describe the detail with more clarity. Make sure all coversand shields are replacedbefore operat­ing this product.
S Some drawings in this manual are shown as typical example and may differ from the shipped
product.
S This manual may be modified when necessary because of improvement of the product, modifica-
tion or changes in specifications. Such modification is made as a revision by renewing the manual No.
S To order a copy of this manual, if your copy has been damaged or lost, contact your YASKAWA
representative listed on the last page stating the manual No. on the front cover.
S YASKAWA is not responsible for accidents or damages due to any modification of the product
made by the user since that will void our guarantee.
NOTES FOR SAFE OPERATION
Read this manual thoroughly before installation, operation, maintenance or inspection of the AC Servo
Drives. In this manual, the NOTES FOR SAFE OPERATION are classified as “WARNING” or
“CAUTION”.
WARNING
Indicates apotentially hazardous situation which, ifnot avoided, couldresult in death or serious personalinju-
ry.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate personal
injury and/or damage to the equipment.
In some instances, items described in
follow these important items.
CAUTION
.
may also result in a serious accident. In either case,
iv
WARNING
(INSTALLATION)
S After voltage resistance test, wait at least five minutes before servicing the
product.
Failure to observe this warning may result in electric shock.
(WIRING)
S Grounding must be in accordance with the national code and consistent
with sound local practices.
Failure to observe this warning may lead to electric shock or fire.
(OPERATION)
S Never touch any rotating motor parts during operation.
Failure to observe this warning may result in personal injury.
(INSPECTION AND MAINTENANCE)
S Be sure to turn OFF power before inspection or maintenance.
Otherwise, electric shock may result.
S After turning OFF power, wait at least five minutes before servicing the
product.
Otherwise, residual electric charges may result in electric shock.
CAUTION
(RECEIVING)
S Use the specified combination of SERVOMOTOR and SERVOPACK.
Failure to observe this caution may lead to fire or failure.
(INSTALLATION)
S Never use the equipment where it may be exposed to splashes of water,
corrosive or flammable gases, or near flammable materials.
Failure to observe this caution may lead to electric shock or fire.
(WIRING)
S Do not connect three−phase power supply to output terminals
.
W
Failure to observe this caution may lead to personal injury or fire.
S Securely tighten screws on the power supply and motor output terminals.
Failure to observe this caution can result in a fire.
UV
and
v
CAUTION
(OPERATION)
S To avoid inadvertent accidents, run the SERVOMOTOR only in test run
(without load).
Failure to observe this caution may result in personal injury.
S Before starting operation with a load connected, set up user constants
suitable for the machine.
Starting operation without setting up user constants may lead to overrun failure.
S Before starting operation with a load connected, make sure emergency-
stop procedures are in place.
Failure to observe this caution may result in personal injury.
S During operation, do not touch the heat sink.
Failure to observe this caution may result in burns.
(INSPECTION AND MAINTENANCE)
S Do not disassemble the SERVOMOTOR.
Failure to observe this caution may result in electric shock or personal injury.
S Never change wiring while power is ON.
Failure to observe this caution may result in electric shock or personal injury.
vi
Manual Contents
This manual providesΣ-Series users with information on the following:
An overview of servo systems for first-time users.
Checking the product on delivery and basic applications of the servo.
Servo applications.
Selecting an appropriate servo for your needs and placing an order.
Inspection and maintenance.
Manual Structure
All chapters in this manual are classified into one or more of three areas according to their contents:A,B, andC. Refer to the applicable chapters for the information you require.
A:
Chapters explaining how to select a servo: For users who wish to gain a basic understanding of
Σ
Series products or who need to select an appropriate servo.
B:
Chapters explaining how to design a servo system: For users who are about to design, install, and operate aΣ-Series Servo Control System.
C:
Chapters explaining maintenance: For users who are going to maintain and troubleshootΣ-Series products.
Chapter
CHAPTER 1 For First-time Users of AC Servos
CHAPTER 2 Basic Uses of Σ-series Products
CHAPTER 3 Applications of Σ-series Products
CHAPTER 4 Using the Digital Operator
CHAPTER 5 Servo Selection and Data Sheets
CHAPTER 6 Inspection, Maintenance, and Troubleshooting
CHAPTER 7 Measures to Satisfy the Requirements of
Title Page Area
...................... .........
Provides an overview of servos and theΣSeries
......................... .........
Describes steps to take when product is received, plus basic wiring and application methods.
....................... .........
Describes the effective usage ofΣ-Series features according to application.
.............................. ........
Describes operating procedures forΣ-Series servos, turning features ON and OFF, setting control constants, etc.
........................ ........
Describes selection methods forΣ-Series servos and peripher­als and provides servo specifications.
Describes user maintenance and troubleshooting.
EMC Directive
Provides the measures to conform to the EMC Directive.
1
15
49
169
203
........... ........
387
415
A, B
B
B
B
A, B
C
B........................................ .........
vii
APPENDIXES
A
B
C
D
E
F
G
Differences between DR2 and DR1, SGDA and SGD Servopacks 423
Servo Adjustment 429
List of I/O Signals 445
List of User Constants 465
List of Alarm Displays 477
Relationship between Reference Forms and User Constants 481
Reviewing the Full-closed Loop Specifications 489
............................................ ........
....................................... ........
....................................... ........
................................... ........
.................................... ........
.. ........
............... ........
A, B. C
B, C
A, B, C
B, C
B, C
B, C
B, C
INDEX
.............................................................. ........
497
A, B, C
viii
Basic Terms
Unless otherwise specified, the following definitions are used:
Servomotor:
Servopack: An amplifier (Trademark of Yaskawa servo amplifier “DR2 Servopack”)
Servodrive: A SGM/SGMP Servomotor and an amplifier (DR2 Servopack)
Servo system: A complete servo control system consisting of servodrive, host controller,
Visual Aids
The following aids are used to indicate certain types of information for easier reference.
.
TERMS
Speed/Torque
Σ
-Series SGM/SGMP Servomotor
and peripheral devices
Indicates references for additional information.
Technical terms placed in bold in the text are briefly explained in a “TERMS” sec­tion at the bottom of the page. The following kinds of technical terms are explained: Technical terms that need to be explained to users who are not very familiar with servo systems or electronic devices and technical terms specific toΣSeries Ser­vos that need to be explained in descriptions of functions.
The text indicated by this icon is applicable only to Servopack in speed/torque con­trol mode.
Positions
JUSP-OP02A-1
NOTE
The text indicated by this icon is applicable only to Servopack in position control mode.
The text indicated by this icon explains the operating procedure using hand-held type digital operator (Type: JUSP-OP02A-1).
AΣ-Series Servodrive alone cannot ensure the functionality and performance of the entire machine control system. It must be combined with an appropriate machine and host control­ler so that the entire control system works properly. Therefore, carefully read the instruction manuals for the machine to be used before attempting to operate the servodrive.
ix
Yaskawa, 1996
All rights reserved. Nopart ofthis publication may be reproduced, stored in a retrievalsystem, ortransmitted, inany form,or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission of Yas­kawa. No patent liabilityis assumedwith respectto theuse of the information contained herein. Moreover, becauseYaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation of this manual. Nevertheless, Yaskawa assumes no re­sponsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained in this publication.
x
CONTENTS
CHAPTER 1 FOR FIRST-TIME USERS OF AC SERVOS 1...............
1.1 Basic Understanding of AC Servos 2..........................................
1.1.1 Servo Mechanisms 2................................................
1.1.2 Servo Configuration 5...............................................
1.1.3 Features of Σ-Series Servos 11.........................................
CHAPTER 2 BASIC USES OF Σ-SERIES PRODUCTS 15.................
2.1 Precautions 16.............................................................
2.1.1 Notes on Use 16....................................................
2.2 Installation 18.............................................................
2.2.1 Checking on Delivery 18..............................................
2.2.2 Installing the Servomotor 19...........................................
2.2.3 Installing the Servopack 22............................................
2.3 Connection and Wiring 25....................................................
2.3.1 Connecting to Peripheral Devices 25....................................
2.3.2 Main Circuit Wiring and Power ON Sequence 28..........................
2.3.3 Examples of Connecting I/O Signal Terminals 30..........................
2.4 Conducting a Test Run 37....................................................
2.4.1 Test Run in Two Steps 37.............................................
2.4.2 Step 1: Conducting a Test Run for Motor without Load 39...................
2.4.3 Step 2: Conducting a Test Run with the Motor Connected to the Machine 43.....
2.4.4 Supplementary Information on Test Run 45...............................
2.4.5 Minimum User Constants Required and Input Signals 47....................
CHAPTER 3 APPLICATIONS OF Σ-SERIES PRODUCTS 49..............
3.1 Setting User Constants According to Machine Characteristics 52.....................
3.1.1 Changing the Direction of Motor Rotation 52..............................
3.1.2 Setting the Overtravel Limit Function 54.................................
3.1.3 Restricting Torque 57................................................
3.2 Setting User Constants According to Host Controller 64............................
3.2.1 Inputting Speed Reference 64..........................................
3.2.2 Inputting Position Reference 69........................................
3.2.3 Using Encoder Output 76.............................................
3.2.4 Using Contact I/O Signals 80..........................................
3.2.5 Using Electronic Gear 82.............................................
3.2.6 Using Contact Input Speed Control 86...................................
3.2.7 Using Torque Control 91..............................................
3.2.8 Using Torque Feed-forward Function 97.................................
3.2.9 Using Torque Restriction by Analog Voltage Reference 98...................
3.2.10 Using the Reference Pulse Inhibit Function (INHIBIT) 100....................
3.2.11 Using the Reference Pulse Input Filter Selection Function 101.................
3.2.12 Using the Analog Monitor 102..........................................
3.3 Setting Up the Σ Servopack 103................................................
3.3.1 Setting User Constants 103.............................................
3.3.2 Setting the Jog Speed 104..............................................
3.3.3 Setting the Number of Encoder Pulses 105.................................
3.3.4 Setting the Motor Type 106.............................................
xi
CONTENTS
3.4 Setting Stop Mode 107.......................................................
3.4.1 Adjusting Offset 107..................................................
3.4.2 Using Dynamic Brake 108.............................................
3.4.3 Using Zero-Clamp 109................................................
3.4.4 Using Holding Brake 110..............................................
3.5 Running the Motor Smoothly 114...............................................
3.5.1 Using the Soft Start Function 114........................................
3.5.2 Using the Smoothing Function 115.......................................
3.5.3 Adjusting Gain 115...................................................
3.5.4 Adjusting Offset 116..................................................
3.5.5 Setting the Torque Reference Filter Time Constant 116.......................
3.6 Minimizing Positioning Time 118...............................................
3.6.1 Using Autotuning Function 118.........................................
3.6.2 Setting Servo Gain 118................................................
3.6.3 Using Feed-forward Control 120.........................................
3.6.4 Using Proportional Control 120.........................................
3.6.5 Setting Speed Bias 121................................................
3.6.6 Using Mode Switch 122...............................................
3.7 Forming a Protective Sequence 128.............................................
3.7.1 Using Servo Alarm Output and Alarm Code Output 128......................
3.7.2 Using Servo ON Input Signal 132........................................
3.7.3 Using Positioning Complete Signal 133...................................
3.7.4 Using Speed Coincidence Output Signal 134...............................
3.7.5 Using Running Output Signal 136.......................................
3.7.6 Using Servo Ready Output Signal 138....................................
3.8 Special Wiring 140..........................................................
3.8.1 Wiring Instructions 140................................................
3.8.2 Wiring for Noise Control 142...........................................
3.8.3 Using More Than One Servo Drive 147...................................
3.8.4 Using Regenerative Units 148...........................................
3.8.5 Using an Absolute Encoder 151.........................................
3.8.6 Extending an Encoder Cable 159........................................
3.8.7 Using DR2 Servopack with High Voltage Line 161..........................
3.8.8 Connector Terminal Layouts 163........................................
CHAPTER 4 USING THE DIGITAL OPERATOR 169.....................
4.1 Basic Operations 170.........................................................
4.1.1 Connecting the Digital Operator 170.....................................
4.1.2 Resetting Servo Alarms 171............................................
4.1.3 Basic Functions and Mode Selection 172..................................
4.1.4 Operation in Status Display Mode 173....................................
4.1.5 Operation in User Constant Setting Mode 176..............................
4.1.6 Operation in Monitor Mode 179.........................................
xii
CONTENTS
4.2 Using the Functions 183......................................................
4.2.1 Operation in Alarm Trace-back Mode 183.................................
4.2.2 Operation Using the Digital Operator 186.................................
4.2.3 Autotuning 188......................................................
4.2.4 Reference Offset Automatic Adjustment 195...............................
4.2.5 Speed Reference Offset Manual Adjustment Mode 197.......................
4.2.6 Clearing Alarm Trace-back Data 200.....................................
4.2.7 Checking Motor Type 201..............................................
4.2.8 Checking Software Version 201.........................................
CHAPTER 5 SERVO SELECTION AND DATA SHEETS 203...............
5.1 Selecting a Σ-Series Servo 205.................................................
5.1.1 Selecting a Servomotor 205............................................
5.1.2 Selecting a Servopack 212.............................................
5.1.3 Digital Operator 216..................................................
5.2 SGM Servomotor 217........................................................
5.2.1 Ratings and Specifications 217..........................................
5.2.2 Mechanical Characteristics 230..........................................
5.3 Servopack Ratings and Specifications 233........................................
5.3.1 Ratings and Specifications 233..........................................
5.3.2 Power Consumption 238...............................................
5.3.3 Overload Characteristics 239...........................................
5.3.4 Starting Time and Stopping Time 240.....................................
5.3.5 Load Inertia 241.....................................................
5.3.6 Overhanging Loads 246...............................................
5.4 Σ-Series Dimensional Drawings 247.............................................
5.4.1 Servomotor Dimensional Drawings 247...................................
5.4.2 Servomotor Dimensional Drawings
5.4.3 Servopack Dimensional Drawings 329....................................
5.4.4 Digital Operator Dimensional Drawing 334................................
5.5 Selecting Peripheral Devices 335...............................................
5.5.1 Selecting Peripheral Devices 335........................................
5.5.2 Order List 341.......................................................
5.6 Specifications and Dimensional Drawings of Peripheral Devices 349...................
5.6.1 Cable Specifications and Peripheral Devices 349............................
5.6.2 Motor Cables 355....................................................
5.6.3 Connector Kits 358...................................................
5.6.4 Brake Power Supply 363...............................................
5.6.5 Encoder Cables 365...................................................
5.6.6 Battery for Absolute Encoder 371........................................
5.6.7 1CN Connector 371...................................................
5.6.8 Circuit Breaker 373...................................................
5.6.9 Noise Filter 374......................................................
5.6.10 Magnetic Contactor 375...............................................
5.6.11 Surge Suppressor 376.................................................
5.6.12 Regenerative Unit 376.................................................
5.6.13 Variable Resistor for Speed Setting 379...................................
(TÜV approved, conforming to the machine instructions) 289..................
xiii
CONTENTS
5.6.14 Encoder Signal Converter Unit 379......................................
5.6.15 Cables for Connecting PC and Servopack 381..............................
5.6.16 4CN Connector 385...................................................
CHAPTER 6 INSPECTION, MAINTENANCE, AND TROUBLESHOOTING 387.
6.1 Inspection and Maintenance 388................................................
6.1.1 Servomotor 388......................................................
6.1.2 Servopack 389.......................................................
6.1.3 Replacing Battery for Absolute Encoder 390...............................
6.2 Troubleshooting 391.........................................................
6.2.1 Troubleshooting Problems with Alarm Display 391..........................
6.2.2 Troubleshooting Problems with No Alarm Display 409.......................
6.2.3 Internal Connection Diagram and Instrument Connection Examples 411.........
CHAPTER 7 MEASURES TO SATISFY THE REQUIREMENTS OF
EMC DIRECTIVE 415.....................................
7.1 What is European Safe Standard? 416............................................
7.1.1 What is EN Standard? 416.............................................
7.1.2 What is CE Marking? 416..............................................
7.1.3 EMC Directive 417...................................................
7.1.4 Certification Body TÜV Authorized by EU 417.............................
7.2 Measures to Satisfy the Requirements of EMC Directive 418.........................
7.2.1 Applicable Servomotor 418.............................................
7.2.2 Applicable Noise Filter 418.............................................
7.2.3 Motor Cables 419....................................................
7.2.4 Encoder Cables 419...................................................
7.2.5 Control I/O 420......................................................
7.2.6 Digital Operator and Monitoring by Personal Computer 420...................
7.2.7 The Core on the Cable 421.............................................
7.2.8 Wiring 421..........................................................
APPENDIXES
A Differences Between DR2 and DR1, SGDA and SGD Servopacks 423..................
B Servo Adjustment 429........................................................
B.1 Σ-Series AC Servopack Gain Adjustment 430.....................................
B.1.1 Σ-Series AC Servopacks and Gain Adjustment Methods 430...................
B.1.2 Basic Rules for Gain Adjustment 431.....................................
B.2 Adjusting a Servopack for Speed Control 432.....................................
B.2.1 Adjusting Using Auto-tuning 432........................................
B.2.2 Manual Adjustment 433...............................................
B.3 Adjusting a Servopack for Position Control 436...................................
B.3.1 Adjusting Using Auto-tuning 436........................................
B.3.2 Manual Adjustment 437...............................................
B.4 Gain Setting References 441...................................................
B.4.1 Guidelines for Gain Settings According to Load Inertia Ratio 441..............
C List of I/O Signals 445........................................................
D List of User Constants 465.....................................................
xiv
CONTENTS
E List of Alarm Displays 477....................................................
F Relationship between Reference Forms and User Constants 481.......................
G Reviewing the Full-closed Loop Specifications 489.................................
INDEX 497...........................................................
xv
FOR FIRST-TIME USERS OF AC SERVOS
1
1
This chapter is intended for first-time users of AC servos. It describes the ba­sic configuration of a servo mechanism and basic technical terms relating to servos. Users who already have experience in using a servo should also take a look at this chapter to understand the features of Σ-Series AC Servos.
1.1 Basic Understanding of AC Servos 2...........
1.1.1 Servo Mechanisms 2.................................
1.1.2 Servo Configuration 5................................
1.1.3 Features of Σ-Series Servos 11..........................
1
1
FOR FIRST-TIME USERS OF AC SERVOS
1.1.1 Servo Mechanisms
1.1 Basic Understanding of AC Servos
This section describes the basic configuration of a servo mechanism and technical terms relating to servos and also explains the features of Σ-Series AC Servos.
1.1.1 Servo Mechanisms 2..............................................
1.1.2 Servo Configuration 5..............................................
1.1.3 Features of Σ-Series Servos 11......................................
1.1.1 Servo Mechanisms
You may be familiar with the following terms:
Servo
Servo mechanism
Servo control system
In fact, these terms are synonymous. They have the following meaning:
A control mechanism that monitors physical quantities such as specified positions.
In short, a servo mechanism is like a servant who does tasks faithfully and quickly according to his master’s instructions. In fact, “servo” originally derives from the word “servant.”
TERMS
Servo mechanism
According to Japanese Industrial Standard (JIS) terminology, a “servo mechanism” is de­fined as a mechanism that uses the position, direction, or orientation of an object as a pro­cess variable to control a system to follow any changes in a target value (set point). More simply, a servo mechanism is a control mechanism that monitors physical quantities such as specified positions. Feedback control is normally performed by a servo mecha­nism. (Source: JIS B0181)
2
1.1 Basic Understanding of AC Servos
Servo system could be defined in more detail as a mechanism that:
Moves at a specified speed and
Locates an object in a specified position
To develop such a servo system, an automatic control system involving feedback control must be designed. This automatic control system can be illustrated in the following block dia­gram:
Configuration of Servo System
Specified position
input
Servo amplifier
Servo motor
Feedback part
Detector
Controlled machine (load)
Machine position
output
This servo system is an automatic control system that detects the machine position (output data), feeds back the data to the input side, compares it with the specified position (input data), and moves the machine by the difference between the compared data.
In other words, the servo system is a system to control the output data to match the specified input data.
If, for example, the specified position changes, the servo system will reflect the changes.
In the above example, input data is defined as a position, but input data can be any physical quantities such as orientation (angle), water pressure, or voltage.
1
TERMS
Position, speed, force (torque), electric current, and so on are typical controlled values for a servo system.
The main technical terms used in this manual are as follows:
1) Servo mechanism
2) Servo
Normally, servo is synonymous with servo mechanism. However, because “mechanism” is omitted, the meaning becomes somewhat ambiguous. Servo may refer to the entire servo mechanism but may also refer to an integral part of a servo mechanism such as a servomotor or a servo amplifier. This manual also follows this convention in the use of the term “servo”.
Feedback control
A control that returns process variables to the input side and forms a closed loop. It is also called closed-loop control.
3
1
FOR FIRST-TIME USERS OF AC SERVOS
1.1.1 Servo Mechanisms cont.
3) Servo control system
Servo control system is almost synonymous with servo mechanism but places the focus on system control. In this manual, the term “servo system” is also used as a synonym of servo control system.
Related Terms Meaning
Servomotor General servomotors or Yaskawa SGM/SGMP
Servomotors. In some cases, a position detector (encoder) is included in a servomotor.
Servopack Trademark of Yaskawa servo amplifier “DR2 Servopack.”
Servo drive A Servomotor and amplifier pair. Also called “servo.”
Servo system A closed control system consisting of a host controller,
servo drive and controlled system to form a servo mechanism.
Host controller
Reference
Amplifier (Servopack)
Servo drive
Servomotor
Servo system
Operate
Controlled system
4
1.1.2 Servo Configuration
1) Configuration of Servo System
The following diagram illustrates a servo system in detail:
1.1 Basic Understanding of AC Servos
Host controller
(5)
Position or speed reference
Servo amplifier
Comparator
(Input)
Position or speed feedback
Power amplifier
Detector
(1) Controlled system: Mechanical system for which the position or speed is to be con-
trolled. This includes a drive system that transmits torque from a servo­motor.
(4)
Motor drive circuit
Gear
(2)
(3)
Servomotor Drive system
(Output)
(1)
Controlled system
Position
Speed
Movable table
Ball screw
1
(2) Servomotor: A main actuator that moves a controlled system. Two types are
(3) Detector: A position or speed detector. Normally, an encoder mounted on
(4) Servo amplifier: An amplifier that processes an error signal to correct the differ-
(5) Host controller: A device that controls a servo amplifier by specifying a position
available: AC servomotor and DC servomotor.
a motor is used as a position detector.
ence between a reference and feedback data and operates the servomotor accordingly. A servo amplifier consists of a comparator, which processes error signals, and a power ampli­fier, which operates the servomotor.
or speed as a set point.
5
FOR FIRST-TIME USERS OF AC SERVOS
1.1.2 Servo Configuration cont.
Servo components (1) to (5) are outlined below:
(1) Controlled system
In the previous figure, the controlled system is a movable table for which the position or speed is controlled. The movable table is driven by a ball screw and is connected to the servomotor via gears. So, the drive system consists of:
1
Gears + Ball Screw
This drive system is most commonly used because the power transmission ratio (gear ratio) can be freely set to ensure high positioning accuracy. However, play in the gears must be minimized.
The following drive system is also possible when the controlled system is a movable table:
Coupling + Ball Screw
When the power transmission ratio is 1 : 1, a coupling is useful because it has no play.
Coupling
Rolling-contact guide
Ball screw
Rolling-contact bearing
This drive system is widely used for ma­chining tools.
Housing
Timing Belt + Trapezoidal Screw Thread
A timing belt is a coupling device that allows the power transmission ratio to be set freely and that has no play.
A trapezoidal screw thread does not provide excellent positioning accuracy, so can be
Trapezoidal screw thread
treated as a minor coupling device.
Servomotor
Timing belt
To develop an excellent servo system, it is important to select a rigid drive system that has no play.
Configure the controlled system by using an appropriate drive system for the control purpose.
TERMS
Drive system
Also called a drive mechanism. A drive system connects an actuator (such as a servomotor) to a controlled system and serves as a mechanical control component that transmits torque to the controlled system, orientates the controlled system, and converts motion from rotation to linear motion and vice versa.
6
(2) Servomotor
(a) DC Servomotor and AC Servomotor
Servomotors are divided into two types: DC servomotors and AC servomotors.
DC servomotors are driven by direct current (DC). They have a long history. Up until the 1980s, the term “servomotor” used to imply a DC servomotor.
1.1 Basic Understanding of AC Servos
From 1984, ACservomotors were emerging as a result of rapid progress inmicro­processor technology. Driven by alternating current (AC), AC servomotors are now widely used because of the following advantages:
Easy maintenance: No brush
High speed: No limitation in rectification rate
Note however that servomotors and Servopacks use some parts that are subject to mechanical wear or aging. For preventive maintenance, inspect and replace parts at regular intervals. For details, refer to Chapter 6 Inspection, Maintenance, and Troubleshooting.
(b) AC Servomotor
AC servomotors are divided into two types: synchronous type and induction type. The synchronous type is more commonly used.
For a synchronous type servomotor, motor speed is controlled by changing the frequency of alternating current.
A synchronous type servomotor provides strong holding torque when stopped, so this type is ideal when precise positioning is required. Use this type for a servo mechanism for position control.
1
Position detector (encoder)
The following figure illustrates the structure of a synchronous type servomotor:
Rotary disc
Light-emitting element
Light-receiving element
Armature wire
Lead wire
Housing
Stator core
Magnet
Front cap
Ball bearing
Shaft
Rotor core
Yaskawa SGM and SGMP Servomotors are of the synchronous type.
7
FOR FIRST-TIME USERS OF AC SERVOS
1.1.2 Servo Configuration cont.
(c) Performance of Servomotor
A servomotor must have “instantaneous power” so that it can start as soon as a start reference is received. The term “power rating (kW/s)” is used to represent instantaneous power. It refers to the electric power (kW) that a servomotor generates per second. The greater the power rating, the more powerful the servomotor.
1
(3) Detector
A servo system requires a position or speed detector. It uses an encoder mounted on a servomotor. Optical and magnetic detection methods are both available. Encoders are divided into the following two types:
(a) Incremental Encoder
An incremental encoder is a pulse generator, which generates a certain number of pulses per revolution (e.g., 2,000 pulses per revolution). If this encoder is con­nected to the mechanical system and one pulse is defined as a certain length (e.g., 0.001 mm), it can be used as a position detector. However, this encoder does not detect an absolute position and merely outputs a pulse train. Hence zero return operation must be performed before positioning. The following figure illustrates the operation principle of a pulse generator (Opti­cal method):
Phase A pulse train
Phase B pulse train
Fixed slit
Light-receiving element
Rotary slit
Center of revolution
Phase A
Phase B
Phase Z
Rotary disc
Slit
Light-emitting element
(b) Absolute Encoder
An absolute encoder is designedto detect an absolute angle of rotation as well as to perform the general functions of an incremental encoder. With an absolute en­coder, therefore, it is possible to create a system that does not require zero return operation at the beginning of each operation.
Difference between an absolute An absolute power is lost and some motion occurs during that period of time. The incremental encoder is incapable of the above.
8
and incremental encoder:
encoder will keep track of the motor shaft position even if system
1.1 Basic Understanding of AC Servos
(4) Servo amplifier
A servo amplifier is required to operate an AC servomotor.
The following figure illustrates the configuration of a servo amplifier:
Servo amplifier
Motor driving AC power
Servomotor
Commercial AC power
Reference input
Comparator
Feedback
Power amplifier
A servo amplifier consists of the following two sections:
(a) Comparator
A comparator consists of a comparison function and a control function. The com­parison function compares reference input (position or speed) with a feedback signal and generates a differential signal.
1
TERMS
The control function amplifies and transforms the differential signal. In other words, it performs proportional (P) control or
proportional/integral (PI) control
(It is not important if you do not understand these control terms completely at this point.)
(b) Power Amplifier
A power amplifier runs the servomotor at a speed or torque proportional to the output of the comparator. In other words, from the commercial power supply of 50/60 Hz, it generates alternating current with a frequency proportional to the ref­erence speed and runs the servomotor with this current.
Proportional/integral (PI) control
PI control provides more accurate position or speed control than proportional control, which is more commonly used.
.
9
1
FOR FIRST-TIME USERS OF AC SERVOS
1.1.2 Servo Configuration cont.
(5) Host Controller
A host controller controls a servo amplifier by specifying a position or speed as a set point.
For speed reference, a position control loop may be formed in the host controller when a position feedback signal is received. Yaskawa PROGIC-8 is a typical host controller.
TERMS
PROGIC-8
A programmable machine controller. If combined with a servo amplifier for speed control (maximum eight axis control), the PROGIC-8 can provide position control. The PROGIC-8 also provides programmable controller functions.
10
1.1.3 Features of Σ-Series Servos
1) Σ-Series SGM/SGMP Servomotors are synchronous type servomotors and have the fol­lowing features:
Size and weight reduced to one-third those of
our conventional models. Compact Servomotor for saving installation space.
Servo performance (power rating) enhanced to
three times that of our conventional models. Enhanced power rating (kW/s) to satisfy every need.
A wide product range covering rated output of
30 W to 750 W.
1.1 Basic Understanding of AC Servos
1
SGM type
Supply Voltage Rated Output 100 VAC: 30 W, 50 W, 100 W, 200 W, 300 W
(0.04 HP, 0.07 HP, 0.13 HP, 0.27 HP, 0.40 HP)
200 VAC: 30 W, 50 W, 100 W, 200 W, 400 W, 750 W
(0.04 HP, 0.07 HP, 0.13 HP, 0.27 HP, 0.53 HP, 1.01 HP)
2) DR2 Servopacks can perform speed/torque or position control. Select the control mode by set­ting of the user constant Cn-02 (memory switch).
Speed/Torque Control Mode: User constant
Cn-02 (memory switch) Bit B = 0 This mode uses speed or torque reference in­put. Reference input is by analog voltage.
Position Control Mode: User constant Cn-02
(memory switch) Bit B = 1 This mode uses position reference input. Reference
input is by pulse train.
SGMP type
DR2 Servopack
TERMS
Power rating (kW/s)
A constant that represents response performance of a servomotor. It can be determined by dividing squared rated torque by motor inertia. Power rating is the electric power (kW) that a servomotor can generate per second. The greater the power rating, the more powerful the servomotor.
11
1
FOR FIRST-TIME USERS OF AC SERVOS
1.1.3 Features ofΣ -Series Servos cont.
3) The most common usage of a speed/torque control Servopack is shown below:
Using Servopack in Speed/Torque Control Mode (Speed Control)
Position feedback
Position reference +
Speed reference
(Analog voltage)
Position
Host controller
Position control loop
Servopack
(speed/torque control)
Speed
Convert
Pulse train
Position feedback
Power amplifier
Servomotor
Torque (current) feedback
Encoder
As shown in the figure above, a position control loop is formed in the host controller. The host controller compares a position reference with a position feedback signal and sends processing results to the Servopack as a speed reference.
In this way, the host controller can freely perform the control required for the servo mech­anism. The Servopack undertakes the speed control loop and subsequent control processing.
Yaskawa programmable machine controller PROGIC-8 is available as a typical host con­troller.
12
1.1 Basic Understanding of AC Servos
4) Speed/torque control Servopack can also provide torque control as shown below.
Using Servopack in Speed/Torque Control Mode (Torque Control)
Host controller
Position monitoring
1
Position information
Speed reference (Analog voltage)
Torque reference
(Analog voltage)
Position
Speed
Convert
Pulse train
Position feedback
Power amplifier
Servopack (speed/torque control)
Torque (current) feedback
Servomotor
Encoder
Set the user constants for Servopack to switch between the following torque control modes:
(1) Controlling servomotor torque by torque reference
(Torque control I)
(2) Operating servomotor by switching between torque reference and speed
reference
(Torque control II)
The host controller outputs a torque reference or speed reference to control the Servo­pack. It also receives a pulse train (position information) from the Servopack and uses it to mon­itor the position.
13
1
FOR FIRST-TIME USERS OF AC SERVOS
1.1.3 Features ofΣ -Series Servos cont.
5) Position control Servopack can be used as below.
Using Servopack in Position Control Mode
Position reference
Position information
Pulse train
Host controller
Position monitoring
Speed/current loop
Pulse train
Position feedback
Servopack
(position control)
Power amplifier
Servomotor
Encoder
The host controller can send a position reference (pulse train) to the Servopack to per­form positioning or interpolation. This type of Servopack contains a position control loop.
User constants can be used to select either of the following pulse trains:
(1) Code and pulse train
(2) Two-phase pulse train with 90° phase difference
(3) Forward and reverse pulse trains
The host controller receives a pulse train (position information) from the Servopack and uses it to monitor the position.
6) A Digital Operator can be used to set user constants for a Servopack as follows:
(1) Setting user constants to enable or disable each function
(2) Setting user constants required for functions to be used
Set user constants according to the servo system to be set up.
14
BASIC USES OF Σ-SERIES PRODUCTS
This chapter describes the first things to dowhenΣ-Series products are deliv­ered. It also explainsthe most fundamentalways of connecting and operating
-Series products. Both first-time and experienced servo users
Σ
this chapter.
2.1 Precautions 16...............................
2.2 Installation 18...............................
2.1.1 Notes on Use 16.....................................
2.2.1 Checking on Delivery 18...............................
2.2.2 Installing the Servomotor 19............................
2.2.3 Installing the Servopack 22.............................
2
must read
2
2.3 Connection and Wiring 25.....................
2.3.1 Connecting to Peripheral Devices 25.....................
2.3.2 Main Circuit Wiring and Power ON Sequence 28............
2.3.3 Examples of Connecting I/O Signal Terminals 30...........
2.4 Conducting a Test Run 37.....................
2.4.1 Test Run in Two Steps 37..............................
2.4.2 Step 1: Conducting a Test Run for Motor without Load 39....
2.4.3 Step 2: Conducting a Test Run with the Motor Connected
to the Machine 4 3....................................
2.4.4 Supplementary Information on Test Run 45................
2.4.5 Minimum User Constants Required and Input Signals 47......
15
2
BASIC USES OF Σ-SERIES PRODUCTS
2.1.1 Notes on Use
2.1 Precautions
This section provides notes on using Σ-Series products.
2.1.1 Notes on Use 16...................................................
2.1.1 Notes on Use
NOTE Always note the following to ensure safe use.
Two types of supply voltage are available, 100 V and 200 V.
Both Σ-Series Servomotor and Servopack have 100 V and 200 V types. Be sure to use the correct type.
Voltage label
Type NP
Always use the SGM/SGMP Servomotor and DR2 Servopack in pairs.
The SGM/SGMP Servomotor cannot run without the DR2 Servopack.
Direct connection
Do not plug the SGM Servomotor directly into the commercial power supply. (Direct connection to the commercial power supply will damage the Servomotor.)
200 V or 100 V power supply
Damage will result!
Do not change wiring when power is ON.
Always turn the power OFF before connecting or disconnecting a connector. (Except for Digital Operator (Type: JUSP­OP02A-1))
CHARGE Lamp Extinguished
Always turn the power OFF before connecting or disconnecting a connector.
Note that residual voltage still remains in the Servopack even after the power is turned OFF.
Even after the power is turned OFF, residual volt­age still remains in the capacitor inside the Servo­pack. Before inspection is to be performed, make sure if CHARGE lamp is extinguished.
CHARGE Lamp
Careful!
Residual voltage remains in capacitor
16
Check if CHARGE lamp goes OFF.
2.1 Precautions
Always follow the specified installation method.
Provide sufficient clearance
10 mm
The Servopack generates heat. Install the Servo­pack so that it can radiate heat freely. Note also that the Servopack must be in an environment free from condensation, vibration and shock.
Ambient temperature: 0to55°C
Perform noise reduction and grounding properly.
If the signal line is noisy, vibration or malfunction will result.
D Separate high-voltage cables from low-voltage cables. D Use cables as short as possible. D Use at least class 3 grounding (ground resistance
100Ω or below) for the Servomotor and Servopack.
D Never use a line filter for the power supply in the
motor circuit.
Casing
Servopack
Signal
Conduct a voltage resistance test under the following conditions.
D Voltage: 1500 Vrms AC, one minute D Braking current: 30 mA D Frequency: 50/60 Hz D Voltage applied point: Between L1, L2, L, N, +, -,
Y3, Y4, U, V, W terminals and ground terminal (connect between terminals securely.)
line
Servomotor
2
Conduct a voltage resistance test as described on the left.
Use a fast-response type ground-fault detector.
For a ground-fault detector, always use a fast-re­sponse type or one designed for PWM inverters. Do not use a time-delay type.
Fast-response type
Ground-fault detector
GOOD POOR
GOOD
For PWM inverter
Do not perform continuous operation under overhanging load.
Continuous operation cannot be performed by ro-
Servomotor
tating the motor from the load and applying regen­erative braking. Regenerative braking by the Ser­vopack can be applied only for a short period, such as the motor deceleration time.
Regenerative braking continuously applied
The Servomotor cannot be operated by turning the power ON and OFF.
Frequently turning the power ON and OFF causes
Servopack
the internal circuit elements to deteriorate. Always start or stop the servomotor by using reference pulses.
Power supply
Time-delay type
Starting and stopping by turning power ON and OFF
17
2
BASIC USES OF S-SERIES PRODUCTS
2.2.1 Checking on Delivery
2.2 Installation
This section describes how to check S-Series products on delivery and how to install them.
2.2.1 Checking on Delivery 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.2 Installing the Servomotor 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.3 Installing the Servopack 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.1 Checking on Delivery
1) When S-Series products are delivered, check the following items:
Check Items Remarks
Check if the delivered products are the ones you ordered.
Check if the motor shaft rotates smoothly.
Check for damage. Check the overall appearance, and check for damage
Check screws for looseness. Check for looseness by using a screwdriver as
Check the types marked on the nameplates of Servomotor and Servopack (see the table below).
If the motor shaft is smoothly turned by hand, it is normal. However, if the motor has brakes, it cannot be turned manually.
or scratches resulting from transportation.
necessary.
If any of the above items are faulty or incorrect, contact the dealer from which you pur­chased the products or your nearest local sales representative.
Appearance Nameplate Type
Servo motor
S-Series
SGM Servomotor
S-Series
SGMP Servomotor
Rated output
Servomotor type
Serial number
Rated rotation speed
Rated current Rated torque
Manufacturing date
S-Series SGM: SGM
Servomotor
SGMP: SGM
Servomotor
Rated Output A3:0.04HP A5:0.07HP 01:0.13HP 02:0.27HP 03:0.40HP 04:0.53HP 08:1.01HP Power supply
A:200V B:100V Encoder specifications 3: 2048P/R incremental encoder
W: 12-bit absolute encoder Design revision order
Shaft specifications 2: Straight without key 4: Straight with key
Option B: With brake S: With oil seal D: With brake and oil seal P: Drip-proof provision
18
Appearance Nameplate Type
Servo­pack
Serial number
Σ-Series DR2 Servopack
Output power voltage
Applicable power supply
2.2.2 Installing the Servomotor
Servomotor SGM and SGMP types can be installed either horizontally or vertically. However, if the Servomotor is installed incorrectly or in an inappropriate location, the service life will be shortened or unexpected problems will occur. To prevent this, always observe the installation instructions described below.
Servopack type
2.2 Installation
DR2-01ACP- F
Σ-Series DR2 Servopack
Rated Ouoput A3:0.04HP A5:0.07HP 01:0.13HP 02:0.27HP 03:0.40HP 04:0.53HP 08:1.01HP Power Supply
Type C: Incremental/absolute
encoder available
Applicable motor Blank: SGM Servomotor P: SGMP Servomotor
Option Blank: Semiclosed loop (standard) P: Fullclosed loop
2
Before installation
Anticorrosive paint is coated on the edge of the motor shaft. Clean off the anticorrosive paint thoroughly using a cloth moistened with thinner.
NOTE
Avoid getting thinner on other parts of the Servomotor when cleaning the shaft.
Storage:
When the Servomotor is to be stored with the power cable disconnected, store it in the following temperature range:
Between −20°C and 60°C
:
Anticorrosive paint is coated here
19
BASIC USES OF Σ-SERIES PRODUCTS
2.2.2 Installing the Servomotor cont.
Installation sites:
The Servomotor SGM and SGMP types are designed for indoor use. Install Servomotor in an environment which meets the following conditions:
a) Free from corrosive and explosive gases
b) Well-ventilated and free from dust and moisture
c) Ambient temperature of 0 to 40°C
d) Relative humidity of 20% to 80% (non-condensing)
e) Inspection and cleaning can be performed easily
2
NOTE
If the Servomotor is used in a location subject to water or oil mist, install a shield cover over the Servomotor.
Alignment
:
Align the shaft of the Servomotor with that of the equipment to be controlled, then connect the shafts with couplings. Install the Servomotor so that alignment accuracy falls within the range shown below.
Measure this distance at four different positions in the circumference. The difference between the maximum and minimum measurements must be
0.03 mm or less. (Turn together with couplings)
Measure this distance at four different positions in the circumference. The difference between the maximum and minimum measurements must be 0.03 mm or less. (Turn together with couplings)
If the shafts are not aligned properly, vibration will occur, resulting in damage to the bear­ings.
Mechanical shock to the shaft end must be less than 98m/s applied no more than twice.
Design the mechanical system so that motor shaft end during operation falls within the range shown in the following table.
TERMS
Thrust load and radial load
1. Thrust load: Shaft-end load applied parallel to the cent­erline of a shaft
2. Radial load: Shaft-end load applied perpendicular to the centerline of a shaft
20
thrust load and radial load
Motor
2
(10G) and must be
applied to the servo-
2.
Shaft end
1.
Servomotor with incremental encoder
2.2 Installation
Allowable
Motor Type
SGM-A3 68 (15) 54 (12) 20 (0.82)
SGM-A5 68 (15) 54 (12) 20 (0.82)
SGM-01 78 (17) 54 (12) 20 (0.82)
SGM-02 245 (55) 74 (16) 25 (1.02)
SGM-03 245 (55) 74 (16) 25 (1.02)
SGM-04 245 (55) 74 (16) 25 (1.02)
SGM-08 392 (88) 147 (33) 35 (1.43)
SGMP-01 78 (17) 49 (11) 20 (0.82)
SGMP-02 245 (55) 68 (15) 25 (1.02)
SGMP-03 245 (55) 68 (15) 25 (1.02)
SGMP-04 245 (55) 69 (15) 25 (1.02)
SGMP-08 392 (88) 147 (33) 35 (1.43)
Servomotor with absolute encoder
Motor Type
SGM-A3 49 (11) 19 (4) 20 (0.82)
SGM-A5 68 (15) 19 (4) 20 (0.82)
SGM-01 68 (15) 19 (4) 20 (0.82)
SGM-02 196 (44) 49 (11) 25 (1.02)
SGM-03 196 (44) 49 (11) 25 (1.02)
SGM-04 196 (44) 68 (15) 25 (1.02)
SGM-08 343 (77) 98 (22) 35 (1.43)
SGMP-01 78 (17) 49 (11) 20 (0.82)
SGMP-02 245 (55) 68 (15) 25 (1.02)
SGMP-03 245 (55) 68 (15) 25 (1.02)
SGMP-04 245 (55) 69 (15) 25 (1.02)
SGMP-08 392 (88) 147 (33) 35 (1.43)
Radial Load
Fr [N(lb)]
Allowable
Radial Load
Fr [N(lb)]
Allowable
Thrust Load
Fs [N(lb)]
Allowable
Thrust Load
Fs [N(lb)]
LR mm (in.)
LR mm (in.)
Reference Drawing
LR
2
Reference Drawing
LR
Note
The radial load and thrust load values shown above are the maximum allowed values for the sum of the load generated by motor torque and the load externally applied to the shaft.
21
BASIC USES OF Σ-SERIES PRODUCTS
2.2.3 Installing the Servopack
2.2.3 Installing the Servopack
Σ-Series DR2 Servopack is a rackmounted type ser- vo controller. Incorrect installation will cause problems. Always ob­serve the installation instructions described in the next page.
2
Storage:
DR2 Servopack
When the Servopack is to be stored with the power cable disconnected, store it in the following temperature range:
Between −20°C and 85°C
Installation sites:
Situation Notes on Installation
Design the control panel size, unit layout, and cooling
When installed in a control panel
When installed near a heating unit
When installed near a source of vibration
When installed in a place receiving corrosive gases
Others
method so that the temperature around the periphery of the Servopack does not exceed 55°C.
Suppress radiation heat from the heating unit and a temperature rise caused by convection so that the temperature around the periphery of the Servopack does not exceed 55°C.
Install a vibration isolator underneath the Servopack to prevent it from receiving vibration.
Corrosive gases do not immediately affect the Servopack but will eventually cause contactor-related devices to malfunction. Take appropriate action to prevent corrosive gases.
Avoid installation in a hot and humid place or where excessive dust or iron powder is present in the air.
Orientation:
Install the Servopack perpendicularly as shown in the figure.
The Servopack must be orientated as shown in the figure because it is designed to be cooled by natural convection.
Firmly secure the Servopack through three or four mounting holes.
22
Ventilation
2.2 Installation
Installation method:
When installing multiple Servopacks side by side in a control panel, observe the following installation method:
Fan
Fin
30 mm or more
10 mm or more
Fan
50 mm or more
50 mm or more
a) Install Servopack perpendicularly so that the front panel (containing connectors) faces
outward.
b) Provide sufficient space around each Servopack to allow cooling by natural
convection.
2
23
BASIC USES OF Σ-SERIES PRODUCTS
2.2.3 Installing the Servopack cont.
c) When installing Servopacks side by side, provide at least 10 mm space between them
and at least 50 mm space above and below them as shown in the figure above. Install
cooling fans above the Servopacks to prevent the temperature around each Servopack
from increasing excessively and also to maintain the temperature inside the control
panel evenly.
d) Maintain the following conditions inside the control panel:
Ambient temperature for Servopack: 0 to 55°C
Humidity: 90%RH or less
2
Vibration: 0.5G (4.9 m/s
Condensation and freezing: None
Ambient temperature to ensure long-term reliability: 45°C or less
2
)
24
2.3 Connection and Wiring
This section describes how to connect Σ-Series products to peripheral devices and explains a typical example of wiring the main circuit. It also describes an example of connecting to main host controllers.
2.3.1 Connecting to Peripheral Devices 25..................................
2.3.2 Main Circuit Wiring and Power ON Sequence 28........................
2.3.3 Examples of Connecting I/O Signal Terminals 30........................
2.3.1 Connecting to Peripheral Devices
This section shows a standard example of connecting Σ-Series products to peripheral de­vices and briefly explains how to connect to each peripheral device.
2.3 Connection and Wiring
2
NOTE Read the following notes before wiring:
Connect only one cable to one terminal. Never connect two cables to one terminal.
Do not solder the cable.
Peel back the cable shield by about 10mm (0.39in.) min. Then insert the cable into the
terminal securely and tighten the screw. Never leave the bare wires outside of the ter­mianl.
When the cable is inserted into the flat terminal, use the following ferrules. Noninsulated ferrules, 2.5mm
<Reference> Terminal block type: FRONT 2.5H/SA5
2
or less (Made by PHOENIX CONTACT)
(Made by PHOENIX CONTACT)
25
BASIC USES OF S-SERIES PRODUCTS
Standard
connection
method
forS-Series
AC
Servo
Drives:
Molded-case circuit breaker (MCCB)
Used to protect power supply line. Shuts the circuit off when overcurrent is detected.
Noise filter
Used to eliminate external noise from power supply line.
Note: The following
noise filters do not conform to the EMC
instructions. As for the noise filters conforming to EMC instructions, refer to 7.2.2.
Types: LF-205A (for DR2-A3A, A5A, 01A,
02A, A3B, A5B, and 01B) LF-210 (for DR2-04A and 02B) LF-220 (for DR2-03B and 08A)
Magnetic contactor
Brake control relay
Power supply: Single-phase 200 or 100 V
Digital Operator
Allows the user to set user constants or operation references and display operation status or alarm status.
Hand-held type (JUSP-OP02A-1) 1-meter(3.3ft.) cable included
S-Series DR2 Servopack
Turns the main power ON or OFF. Use a surge suppressor for the magnetic contactor.
Type: HI-15E5 (30 A)
Brake power supply
Used for Servomotor with brake.
Types:
LPSE-2H01
(for 200 V input)
LPDE-1H01
(for 100 V input)
Regenerative unit
(For types DR2-A3A, A5A, 01A, 02A)
Type: JUSP-RG08 (Not applicable to types DR2A3B, A5B, 01B)
Exterior type regenerative resistor
Applicable to DR2-04ACY8, 08ACY8, 02BCY8, 03BCY8)
This wiring is required
This wiring is required
only for a Servomotor
only for a Servomotor
with brake
with brake
W
See the precautions on wiring (on the previous page).
L1 L2
L
N U V
+(Y3), -(Y4)
U V W
Connector for PG
Connector for PG
(on Servopack side)
(on Servopack side)
Connector kits for pulse generator (PG) and for motor are not required if the following parts are ordered:
S Cable with terminal connectors S Cable with connector and amplifier terminal
26
Personal computer
Exclusive-use cable between personal computer and Servo­pack (for NEC PC) is available. Type: DE9405258 (2m, 6.6ft.) consult factory about cable for IBM PC.
1CN connector kit
(Type: DP9420010)
Host controller
Servopack is compatible with most P.L.C.motion controllers and indexers.
References are input as analog signals or pulse trains.
PROGIC-8
Cable for PG
This cable is used to connect a Servomotor encoder to a Servopack.
The following two types of cable are available according to the encoder type. As for the PG cables conforming to EMC instructions, refer to
7.2.4.
Cable for incremental encoder (with connector on both ends)
9.8ft: DP9320082-1 16.4ft: DP9320082-2
32.8ft: DP9320082-3 49.2ft: DP9320082-4
65.6ft: DP9320082-5
Cable for absolute encoder (with connectors on both ends)
9.8ft: DP9320084-1 16.4ft: DP9320084-2
32.8ft: DP9320084-3 49.2ft: DP9320084-4
65.6ft: DP9320084-5
A cable with a single connector (without connector on Servopack side) and a cable without connectors are also available.
Connector kit for PG
On Servomotor side On Servopack side
Connector for PG (on motor side)
Connector for motor
Σ-Series Servomotor
This connector kit is required for cables without connectors. For moving parts, a cablefor robot must be ordered separately.
Cable for motor
This is a power cable for connecting a Servomotor to a Servopack.
For a Servomotor with brake, this cable is also used to wire the brake. As for the motor cables conforming to EMC instructions, refer to
5.6.1.
Without brake (connector included)
9.8ft: DP9320659-1 16.4ft: DP9320659-2
32.8ft: DP9320659-3 49.2ft: DP9320659-4
65.6ft: DP9320659-5
With brake (connector included)
9.8ft: DP9320660-1 16.4ft: DP9320660-2
32.8ft: DP9320660-3 49.2ft: DP9320660-4
65.6ft: DP9320660-5
A cable without connector and spare solder is also available.
Connector kit for motor
Connector for motor (on motor side)
This connector kit is required for cables without connector and amplifier terminal.
27
BASIC USES OF Σ-SERIES PRODUCTS
2.3.2 Main Circuit Wiring and Power ON Sequence
2.3.2 Main Circuit Wiring and Power ON Sequence
1) The following diagram shows a typical example of wiring the main circuit for Σ-Series products:
2
Single-phase 200 to 230 VAC 50/60 Hz
RT
1MCCB
1FIL
Main Power
OFF
+ 10
%
,
–15
1Ry
ON
1MC
1Ry
1MCCB: Circuit breaker 1FIL: Noise filter 1MC: Contactor 1Ry: Relay 1PL: Patrol light 1SUP: Surge suppressor 1D: Flywheel diode
1PL
1MC
1SUP
For 100 V Type Single-phase 100 to 115 VAC 50/60 Hz
Servopack DR2
1MC
L1
L2 L
N
U V W
ALM+
ALM-
+ 10
–15
A
B
C
D
1CN
31
32
%
,
M
PG
+24V
1Ry
0
V
24
1D
2) The following table shows the name and description of each main circuit terminal:
Terminal
Symbol
L1, L2
L, N
U, V, W
×2
Y3, Y4
+,
*1 For 100 V power supply: Single-phase 100 to 115 VAC
*2 Provided only for types 400W, 750W (200VAC) and 200W, 300W (100VAC). *3 Provided only for types 30W to 200W (200VAC).
28
Name Description
Main circuit AC input
Control power supply input
Motor connection
Ground terminal
Regenerative resistor connection
Regenerative unit connection
Single-phase 200 to 230 VAC , 50/60Hz*
Single-phase 200 to 230 VAC , 50/60Hz*
Connects terminal U to motor terminal (red), V to (white) and W to (blue).
Connects to ground and motor terminal (for ground and motor grounding)
Regenerative resistor connection (External connection is not normally required.)*
Regenerative unit connection terminal (Connection is not normally required.)*
2
3
+ 10
–15
+ 10
–15
+ 10
%
%
–15
%
, 50/60Hz
1
1
2.3 Connection and Wiring
3) Form a power ON sequence as follows:
a) Form a power ON sequence so that the main power is turned OFF when a servo alarm
signal is output. (See the circuit diagram shown on the previous page.)
b) Hold down the power ON push-button for at least two seconds. The Servopack out-
puts a servo alarm signal for approximately two seconds or less when the power is turned ON. This operation is required to initialize the Servopack.
Power supply
Servo alarm (ALM) output signal
NOTE D After turning the power OFF, do not touch the power terminals for 5 minutes. High voltage
may remain in the Servopack.
2
D Avoid frequently turning the power ON and OFF. Since the Servopack has a capacitor in
the power supply, a high charging current flows (for 0.2 second) when the power is turned
ON. Therefore, frequently turning the power ON and OFF causes the main power devices
(such as capacitors and fuses) to deteriorate, resulting in unexpected problems.
29
BASIC USES OF Σ-SERIES PRODUCTS
2.3.3 Examples of Connecting I/O Signal Terminals
2.3.3 Examples of Connecting I/O Signal Terminals
1) This sub-section provides typical examples of connecting to main host controllers. Con­nection to other host controllers is also possible. Connect to the host controller according to the connection examples shown below by referring to technical documentation for the host controller.
NOTE This sub-section describes signals related to the DR2 Servopack only. For other signals,
refer to the relevant technical documentation.
2) Example of Connecting to PROGIC-8
2
Servopack for Speed Control
Servopack
Speed
(MADE BY YASKAWA)
FG (connector frame)
Cable between PROGIC8 and DR2 Servopack
.
30
*1 These pin numbers are also applicable to SV2 to SV4.
*2 Do not change the standard settings of user constants for the Servopack.
Type JEPMC W5521 05 (1.6ft.)
JEPMC W5521 10 (3.3ft.) JEPMC W5521 30 (9.8ft.)
Speed
3) Example of Connecting to GL-Series Positioning Module B2833
Servopack for Speed Control
SERVOPACK
(MADE BY YASKAWA)
SERVO NORMAL
35
DECEL LS
D/A OUTPUT
2.3 Connection and Wiring
2
*1
ALARM
*1 These signals are output for approximately two seconds when the power is turned ON. Take this into consideration when designing a power ON sequence. Relay 1Ry is used to stop main circuit power supply to the Servopack.
31
2
BASIC USES OF Σ-SERIES PRODUCTS
2.3.3 Examples of Connecting I/O Signal Terminals cont.
4) Example of Connecting to GL-Series Positioning Module B2813
Servopack for Position Control
Positions
(MADE BY YASKAWA)
SERVO NORMAL
35
DECEL LS
Servopack
ALARM
*1 These signals are output for approximately two seconds when the power is turned ON. Take this into consideration when designing a power ON sequence. Relay 1Ry is used to stop main circuit power supply to Servopack.
*2 Change the Cn-02 setting as follows: Bit No. 3 = 0 Bit No. 4 = 0 Bit No. 5 = 0 Bit No. B = 1
*3 Pull up the CLR signal with 1 k resistance. Change the Cn-02 setting as follows: Bit No. A =1
32
Speed
2.3 Connection and Wiring
5) Example of Connecting to OMRON Position Control Unit C500-NC222
Servopack for Speed Control
Servopack
I/O POWER SUPPLY
C500-NC222 (MADE BY OMRON)
X-AXIS (Y-AXIS)
(ON when positioning is stopped) (ON when proximity is detected)
2
* These signals are output for approximately two seconds when the power is turned ON. Take this into consideration when designing a power ON sequence. Relay 1Ry is used to stop main circuit power supply to Servopack.
Note The signals shown here are applicable only to OMRON Sequencer
C500-NC222 and Yaskawa Servopack DR2-VVVV.
33
2
BASIC USES OF Σ-SERIES PRODUCTS
2.3.3 Examples of Connecting I/O Signal Terminals cont.
6) Example of Connecting to OMRON Position Control Unit C500-NC112
Servopack for Position Control
Positions
C500-NC112
(MADE BY OMRON)
CW LIMIT
CCW LIMIT
EMERGENCY STOP
EXTERNAL INTERRUPT
HOME POSITION
HOME POSITION PROXIMITY
LOCAL
READY
PULSE OUTPUT CW + CCW DIRECTION OUTPUT CW
I/O POWER SUPPLY
(ON when proximity is detected)
SERVOPACK
EXTERNAL POWER SUPPLY
1
7
SG
O24V
*1 These signals are output for approximately two seconds when the power is turned ON. Take this
into consideration when designing a power ON sequence. Relay 1Ry is used to stop main circuit power supply to Servopack.
*2 Change the Cn-02 setting as follows:
Bit No. 3 = 1 Bit No. 4 = 0 Bit No. 5 = 0
*3 Manufactured by Yaskawa Controls Co., Ltd.
Note The signals shown here are applicable only to OMRON Sequencer C500-NC112 and
Yaskawa Servopack DR2-VVVV.
34
Speed
7) Example of Connecting to MITSUBISHI Positioning Unit AD72
Servopack for Speed Control
SERVOPACK
I/O POWER SUPPLY
(MADE BY MITSUBISHI)
AD72
(ON when position­ing is stopped)
(ON when proximity is detected)
SPEED REF­ERENCE
2.3 Connection and Wiring
2
*1 These signals are output for approximately two seconds when the power is turned ON. Take this into
consideration when designing a power ON sequence. Relay 1Ry is used to stop main circuit power supply to Servopack.
*2 These pin numbers are the same for both X and Y axes.
Note The signals shown here are applicableonly toMITSUBISHI SequencerAD72 andYas-
kawa Servopack DR2-VVVV.
35
2
BASIC USES OF Σ-SERIES PRODUCTS
2.3.3 Examples of Connecting I/O Signal Terminals cont.
8) Example of Connecting to MITSUBISHI Positioning Unit AD71 (B Type)
Servopack for Position Control
Positions
I/O POWER SUPPLY
AD71 (B TYPE)
(MADE BY MITSUBISHI)
X AXIS (Y AXIS)
(ON when positioning is stopped)
(ON when proximity is detected)
SERVOPACK
EXTERNAL POWER SUPPLY +24V
1
SG
36
O24V
*1 These signals are output for approximately two seconds when the power is turned ON. Take this into
consideration when designing a power ON sequence. Relay 1Ry is used to stop main circuit power supply to Servopack.
*2 Manufactured by Yaskawa Controls Co., Ltd.
Note The signals shown here are applicable only to MITSUBISHI Sequencer AD71 (B Type)
and Yaskawa Servopack DR2-VVVV.
2.4 Conducting a Test Run
This section describes how to conduct a full test run. The test run is divided into two steps. Complete a test run in step 1 first, then proceed to step 2.
2.4.1 Test Run in Two Steps 37............................................
2.4.2 Step 1: Conducting a Test Run for Motor without Load 39................
2.4.3 Step 2: Conducting a Test Run with the Motor Connected to the Machine 43
2.4.4 Supplementary Information on Test Run 45............................
2.4.5 Minimum User Constants Required and Input Signals 47.................
2.4.1 Test Run in Two Steps
Conduct the test run when wiring is complete.
2.4 Conducting a Test Run
2
NOTE
Generally, conducting a test run for servo drives can bedifficult. However,by following the two steps described below, the test run can be performed safely and correctly.
To prevent accidents, initially conduct a test run only for a servomotor under no load (i.e., with all couplings and belts disconnected). Do not run the servomotor while it is connected to a machine.
The test run is divided here into steps 1 and 2.
Complete the test run in step 1 first, then proceed to step 2. The purposes of each step are described on the next page.
37
BASIC USES OF Σ-SERIES PRODUCTS
2.4.1 Test Run in Two Steps cont .
Step 1: Conducting a test run for the motor without load Check that the motor is wired correctly....
2
Operate the motor with a Digital Operator.
Check wiring.
Step 2: Conducting a test run with the motor and
machine connected Adjust Servopack according to machine.................................
Speed adjustment by autotuning
DR2
Do not connect to a machine.
Conduct a test run with the motor shaft disconnected from the machine.
Purpose:
Outline:
Connect to the machine and conduct a test run.
Purpose:
To check power supply circuit wiring
To check motor wiring
To check I/O signal (1CN) wiring
Turn the power ON.
Operate the motor with a digital op-
erator.
Check I/O signals (1CN).
Conduct a test run using I/O signals.
characteristics.
To perform autotuning to adjust the mo­tor according to machine characteris­tics
To match the speed and direction of rotation with themachine specifications
To check the final control mode
Connect to the machine.
Outline:
End of test run
For customers who use a servomotor with a brake, refer to
Information on Test Run
before starting a test run.
Perform autotuning.
Adjust user constant settings.
Record user constant settings.
Section 2.4.4 Supplementary
The following pages describe the test run procedure in detail.
38
2.4 Conducting a Test Run
2.4.2 Step 1: Conducting a Test Run for Motor without Load
Check that the motor is wired correctly. If the motor fails to rotate properly during a servo drive test run, the cause most frequently lies in incorrect wiring. Conduct a test run for the motor without load according to the procedure described below. For customers who use a servomotor with brake, refer to Section 2.4.4 Supplemental In- formation on Test Run before starting a test run.
Operate the motor with a Digital Operator.
2
Check wiring.
Do not connect to the machine.
(1) Secure the servomotor.
Secure the servomotor to mounting holes to prevent it from moving during operation. Alter­natively, install the servomotor on the machine and disconnect couplings and belts.
(2) Disconnect connector 1CN, then check the
motor wiring in the power supply circuit.
(When incremental encoder is used)
I/O signals (1CN) are not to be used so leave connector 1CN disconnected.
(When absolute encoder is used)
Connect the battery to the battery terminals 1CN-21, -22.
(3) Short the alarm signal circuit.
Because connector 1CN is disconnected, the alarm signal prevents the power supply circuit from being turned ON. Therefore, temporarily short the alarm signal circuit.
Secure servomotor to mounting holes.
Do not connect anything to the motor shaft (no-load status).
Disconnect connector 1CN
Power supply 0V +24V
Short this circuit.
Force this relay ON.
ALM+
ALM-
1CN disconnected
(1CN31)
(1CN32)
39
BASIC USES OF Σ-SERIES PRODUCTS
2.4.2 Step 1: Conducting a Test Run for Motor without Load cont.
(4) Turn the power ON.
Turn the Servopack power ON. If the Servo­pack is turned ON normally, the LED on the Digital Operator lights up as shown in the fig­ure. Power is not supplied to the servomotor be­cause the servo is OFF.
If an alarm display appears on the LED as shown in the figure above, the power supply circuit, motor wiring or encoder wiring is incor­rect. In this case, turn the power OFF, then cor­rect the problem.
2
(5) Operate using the Digital Operator
Operate the motor with the Digital Operator. Check that the motor runs normally.
Refer to 4.2.2 Operating Using the Digital Op- erator.
(6) Connect signal lines.
Connect connector 1CN as follows:
(1) Turn the power OFF.
(2) Return the alarm signal circuit shorted in the
above step (3) to its original state.
(3) Connect connector 1CN.
(4) Turn the power ON again.
(7) Check input signals.
Check the input signal wiring in monitor mode. For the checking method, refer to 4.1.6 Opera- tion in Monitor Mode.
Operation by Digital Operator
If an alarm occurs, the power supply circuit, motor wiring, or encoder wiring is incorrect.
After turning the power OFF, re­move the short circuit.
Connect connector 1CN.
Example of Un-05
Internal status bit display (Un-05, Un-06)
N-CL (1CN-46)
P-CL (1CN-45)
ALM+
ALM-
Checking method Turn each connected signal line ON and OFF to check that the monitor bit display changes accordingly.
High level or open OFF Extinguished
0 V level ON Lit
40
S-ON (1CN-40)
Input Signal ON/OFF Monitor Bit Display
P-CON (1CN-41)
The memory switch can be used to
for
external short-circuits in
wiring (Refer to 3.1.2).
P-OT (1CN-42)
eliminate the need
N-OT (1CN-43)
2.4 Conducting a Test Run
If the signal lines below are not wired correctly, the motor fails to rotate. Always wire them correctly. (If signal lines are not to be used, short them as necessary.)
P-OT 1CN-42 Motor can rotate in forward direction when this input signal is at 0 V.
N-OT 1CN-43 Motor can reverse when this input signal is at 0 V.
S-ON 1CN-40 Servo is turned ON when this input signal is at 0 V. However, leave
the servo in OFF status.
(8) Turn servo (motor) ON.
Turn the servo ON as follows:
(1) Check that no reference has been input.
Speed/torque control mode : V-REF (1CN-5) and T-REF (1CN-9) are at 0 V.
Position control mode: PULS (1CN-7) and SIGN (1CN-11) are fixed.
(2) Turn the servo ON signal ON.
Set S-ON
(1CN-40) to 0 V. If normal, the motor is turned ON and the Digital Operator displays the data as shown in the figure. If an alarm dis­play appears, take appropriate action as de­scribed in Appendix E List of Alarm Displays.
Servopack
ON
S
(1CN40)
Turn the servo ON
Display when servo is turned ON
Servomotor
2
Speed/Torque
(9) Operate by reference input.
The operating procedure differs according to the Servopack control mode used.
Speed/Torque Control Mode
(This section describes the standard speed con-
Servopack
trol setting.)
(1CN5)
(1) Gradually increase the speed reference input
(V-REF, 1CN-5) voltage. The motor will rotate.
Servomotor rotates at a speed proportional to the reference voltage.
(1CN6)
When a host controller such as a programmable controller performs position control, it may be difficult to directly input the speed reference voltage. In this case, constant voltage reference should be input once to ensure correct opera­tion.
Servomotor
41
BASIC USES OF Σ-SERIES PRODUCTS
2.4.2 Step 1: Conducting a Test Run for Motor without Load cont.
(2) Check the following items in monitor mode (Refer to 4.6.1.):
(1) Has a reference speed been input?
(2) Is the motor speed as designed?
(3) Does the reference speed match the actual motor speed?
(4) Does the motor stop when no reference is input?
2
Positions
Un-00
Actual motor speed
Un-01 Reference speed
(3) If the motor rotates at an extremely slow speed when 0 V is specified as the reference
voltage, correct the reference offset value as described in Section 4.2.4 Reference
Offset Automatic Adjustment
(4) To change motor speed or the direction of rotation, reset the user constants shown
below.
Cn-03
Speed reference gain (Refer to 3.2.7.)
Cn-02 bit 0 Reverse rotation mode (Refer to 3.1.1.)
Position Control Mode
(1) Set user constant Cn-02 so that the reference pulse form matches the host controller
output form. (Refer to 4.1.5 for details on how to set user constants.)
Selecting reference pulse form (Refer to 3.2.2.)
Bit 3
Cn-02
Bit 4
Bit 5
(2) Input a slow speed pulses from the host con-
troller and execute low-speed operation.
42
Host controller
Refer­ence pulse
Servopack
(1CN7)
(1CN8)
(1CN11)
(1CN12)
Servomotor
(3) Check the following items in monitor mode
(Refer to 4.6.1.):
(1) Has a reference pulse been input?
(2) Is the motor speed as set?
(3) Does the reference speed match the actual motor speed?
(4) Does the motor stop when no reference is input?
2.4 Conducting a Test Run
Un-00
Un-07 Reference pulse speed display
Un-08 Position error
(4) To change motor speed or the direction of rotation, reset the user constants shown
below.
Cn-24,Cn-25
If an alarm occurs or the motor fails to rotate during the above operation, connec­tor 1CN wiring is incorrect or the user constant settings do not match the host con­troller specifications. In this case, check the wiring and review the user constant settings, then repeat step 1.
Refer to Appendix E List of Alarm Displays and Appendix D List of UserConstants.
This is all that is required to completestep 1 (conducting a test run for motor without load). Whenever possible, perform tuning associated with the host controller and other neces­sary adjustments in step 1 (before installing the motor on the machine).
Actual motor speed
Electronic gear ratio (Refer to 3.2.5.)
Cn-02 bit 0 Reverse rotation mode (Refer to 3.1.1.)
2
2.4.3 Step 2: Conducting a Test Run with the Motor Connected to the Machine
After step 1 is complete, proceed to step 2 in which a test run is conducted with the motor connected to the machine. The purpose of step 2 is to adjust the Servopack according to the machine characteristics. Conduct a test run according to the procedure described below.
DR2 Servopack
Purposes: 1) Autotuning
2) Speed adjustment
Servomotor
Connect to the machine.
43
BASIC USES OF Σ-SERIES PRODUCTS
2.4.3 Step 2: Conducting a Test Run with the Motor Connected to the Machine cont.
NOTE Before proceeding to step 2, repeat step 1 (conducting a test run for the motor without load)
until you are fully satisfied that the test has been completed successfully. Operation faults that arise after the motor is connected to the machine not only damage the machine but may also cause an accident resulting in injury or death. Therefore, all items including user constants setting and wiring should be tested as conclusively as possible before step 1 is complete.
2
(1) Check that power is OFF.
Turn the Servopack power OFF.
(2) Connect the servomotor to the machine.
Refer to 2.2.2 Installing the Servomotor.
(3) Perform autotuning.
Tune the Servopack according to the machine characteristics. Refer to 4.2.3 Autotuning.
Power supply
Power OFF
Install servomotor on machine.
Servomotor
Autotuning:
Automatically measures machine characteristics and performs optimum tuning
DR2
Servopack Servomotor
Servopack
44
(4) Operate by reference input.
As in step 1 (conducting a test run for motor
Host controller
Servopack
Servomotor
without load), perform (9) Operate by refer- ence input on page 41. Perform tuning
Reference
associated with the host controller.
(5) Set user constants and record the settings.
Servopack
Set user constants as necessary. Record all the user constant settings for maintenance
User constants
purposes.
Record the settings
This is all that is required to conduct the test run.
Normally, the machine may cause much friction because of an insufficient running-in pe­riod. After a test run is complete, perform adequate running-in.
2.4.4 Supplementary Information on Test Run
In the following cases, always refer to the information described below before starting a test run:
When using a servomotor with a brake
When performing position control from the host controller
1) When using a servomotor with brake
The brake prevents the motor shaft from rotating due to a backdriving torque. Such a torque may be created by an external force or the force of gravity acting on the load and may result in undesired motion or the load, should motor power be lost.
2.4 Conducting a Test Run
Servopack uses the brake interlock output (BK) signal to control holding brake operation for a servomotor with brake.
Vertical axis
Servomotor
Holding brake
Prevents the motor from rotating due to gravity
Axis to which external force is applied
External force
Servomotor
Holding brake
NOTE To prevent faulty operation caused by gravity (or external force), first check that the motor
and holding brake operate normally with the motor disconnected from the machine. Then, connect the motor to the machine and conduct a test run.
For wiring of a servomotor with a brake, refer to 3.4.4
Brake control relay
Brake power supply LPSE-2H01 (200 V input) LPDE-1H01 (100 V input)
Power supply: single-phase 200 V or 100 V
U V W
Servopack
Using Holding Brake.
Cable for motor with brake
9.8ft DP9320660-1
16.4ft DP9320660-2
32.8ft DP9320660-3
49.2ft DP9320660-4
65.6ft DP9320660-5
2
Servomotor with brake
45
2
BASIC USES OF Σ-SERIES PRODUCTS
2.4.4 Supplementary Information on Test Run cont.
2) When performing position control from the host controller
Check motor operation first and then conduct a test run as described in the table below.
Host controller
Position control
Type: DR2jjjj
Speed reference
Speed control
GOOD POOR
MM
Test run for motor without load
NOTE Check the motor operation withthe motor disconnected from the machine. If the host con-
troller does not perform position control correctly, the motor may run out of control.
Reference from Host Controller
Jogging (constant-speed reference input from host controller)
Simple positioning
Overtravel (when P-OT and N-OT signals are used)
Check Items Check Method Review Items
Check the motor speed as follows:
D Use the speed
monitor (Un-00) of the digital operator.
Check whether the speed reference gain value (user constant Cn-03) is correct.
Check whether the dividing ratio count (user constant Cn-0A) is correct.
If the motor does not stop, review the P-OT and N-OT wiring.
Motor speed
Number of motor revolutions
Whether the motor stops rotating when P-OT and N-OT signals are input
D Run the motor at
low speed. For example, input a speed reference of 60 r/min and check that the motor makes one revolution per one second.
D Input a reference
equivalent to one motor revolution and visually check that the motor shaft makes one revolution.
D Check that the
motor stops when P-OT and N-OT signals are input during continuous motor operation.
46
2.4 Conducting a Test Run
2.4.5 Minimum User Constants Required and Input Signals
1) This section describes the minimum user constants that must be set to conduct a test run. For details on how to set each user constant, refer to 4.1.5 Operation in User Constant Setting Mode.
a) Servopack in speed/torque control mode
Cn-03
Speed reference gain
Cn-0A Dividing ratio setting
b) Servopack in torque control mode
Cn-13
Torque reference adjustment gain
Cn-0A Dividing ratio setting
c) Servopack in position control mode
Cn-02 bits 3, 4 and 5
Reference pulse form selection
Cn-24 Electronic gear ratio (numerator)
Cn-25 Electronic gear ratio (denominator)
After changing the Cn-02 setting, always turn the power OFF, then ON. This makes the new setting valid.
2) If the specified direction of rotation differs from the actual direction of rotation, the wiring may be incorrect. In this case, recheck the wiring and correct it accordingly. Then, if the direction of rotation is to be reversed, set the following user constant:
2
Cn-02 (bit 0)
After changing the Cn-02 setting, always turn the power OFF, then ON. This makes the new setting valid.
3) The following table lists the minimum input signals required to conduct a test run. For de­tails of each input signal, refer to the relevant page.
Signal Name
S-ON (servo ON) 1CN-40
P-OT
N-OT
(forward rotation prohibited)
(revere rotation prohibited)
Reverse rotation mode
Pin
Number
Switching between motor ON and OFF status.The memory switch can be used to eliminate the need for external short-circuit wiring (see page 132).
1CN-42
1CN-43
Overtravel limit switch The memory switch can be used to eliminate the need for external short-circuit wiring (see page 54).
Function
47
APPLICATIONS OF Σ-SERIES PRODUCTS
This chapteris prepared forreaders who wishto learn more about the applica­tions ofΣ-series products after fully understanding Chapter 2 Basic Uses of
-series Products. It explains how to set user constants for each purpose and
Σ
how to use each function. Read the applicable sections according to your re­quirements.
3.1 Setting User Constants
3
3
Before Reading this Chapter 51...............................
According to Machine Characteristics 52.......
3.1.1 Changing the Direction of Motor Rotation 52...............
3.1.2 Setting the Overtravel Limit Function 54..................
3.1.3 Restricting Torque 57.................................
3.2 Setting User Constants
According to Host Controller 64...............
3.2.1 Inputting Speed Reference 64...........................
3.2.2 Inputting Position Reference 69.........................
3.2.3 Using Encoder Output 76..............................
3.2.4 Using Contact I/O Signals 80...........................
3.2.5 Using Electronic Gear 82..............................
3.2.6 Using Contact Input Speed Control 86....................
3.2.7 Using Torque Control 91...............................
3.2.8 Using Torque Feed-forward Function 97..................
3.2.9 Using Torque Restriction by Analog Voltage Reference 98....
3.2.10 Using the Reference Pulse Inhibit Function (INHIBIT) 100.....
3.2.11 Using the Reference Pulse Input Filter Selection Function 101..
3.2.12 Using the Analog Monitor 102...........................
3.3 Setting Up the Σ Servopack 103................
3.3.1 Setting User Constants 103..............................
3.3.2 Setting the Jog Speed 104...............................
3.3.3 Setting the Number of Encoder Pulses 105..................
3.3.4 Setting the Motor Type 106..............................
3.4 Setting Stop Mode 107........................
3.4.1 Adjusting Offset 107...................................
49
3
Chapter Table of Contents, Continued
3.4.2 Using Dynamic Brake 108..............................
3.4.3 Using Zero-Clamp 109.................................
3.4.4 Using Holding Brake 110...............................
3.5 Running the Motor Smoothly 114...............
3.5.1 Using the Soft Start Function 11 4.........................
3.5.2 Using the Smoothing Function 11 5........................
3.5.3 Adjusting Gain 11 5....................................
3.5.4 Adjusting Offset 11 6...................................
3.5.5 Setting the Torque Reference Filter Time Constant 116........
3.6 Minimizing Positioning Time 118...............
3.6.1 Using Autotuning Function 118..........................
3.6.2 Setting Servo Gain 11 8.................................
3.6.3 Using Feed-forward Control 120..........................
3.6.4 Using Proportional Control 120..........................
3.6.5 Setting Speed Bias 121.................................
3.6.6 Using Mode Switch 122................................
3.7 Forming a Protective Sequence 128.............
3.7.1 Using Servo Alarm Output and Alarm Code Output 128.......
3.7.2 Using Servo ON Input Signal 132.........................
3.7.3 Using Positioning Complete Signal 133....................
3.7.4 Using Speed Coincidence Output Signal 134................
3.7.5 Using Running Output Signal 136........................
3.7.6 Using Servo Ready Output Signal 138.....................
3.8 Special Wiring 140...........................
3.8.1 Wiring Instructions 140.................................
3.8.2 Wiring for Noise Control 142............................
3.8.3 Using More Than One Servo Drive 147....................
3.8.4 Using Regenerative Units 148............................
3.8.5 Using an Absolute Encoder 151..........................
3.8.6 Extending an Encoder Cable 159.........................
3.8.7 Using DR2 Servopack with High Voltage Line 161...........
3.8.8 Connector Terminal Layouts 163.........................
50
Before Reading this Chapter
1) This chapter describes how to use each 1CN connector I/O signal for the DR2 Servopack and how to set the corresponding user constant.
2) For a list of I/O signals of 1CN connecor, refer to Appendix C List of I/O Signals. For terminal arrangement for I/O signals of 1CN connecor, refer to 3.8.8 Connector Ter- minal Layouts.
3) For a list of user constants, refer to Appendix D List of User Constants.
4) User constants are divided into the following two types.
I/O signals
Host controller, external circuit
3
1) Memory switch Cn-01 and Cn-02
2) Constant setting Cn-03 and later
Set each bit to ON or OFF to select a function.
Set a numerical value such as a torque limit value or speed loop gain.
DR2 Servopack
User constants
5) For details on howto set user constants, refer to 4.1.5 Operation in User Constant Setting
Mode.
51
APPLICATIONS OF Σ-SERIES PRODUCTS
3.1.1 Changing the Direction of Motor Rotation
3.1 Setting User Constants According to Machine Characteristics
This section describes how to set user constants according to the dimensions and performance of the machine to be used.
3.1.1 Changing the Direction of Motor Rotation 52...........................
3.1.2 Setting the Overtravel Limit Function 54...............................
3.1.3 Restricting Torque 57...............................................
3.1.1 Changing the Direction of Motor Rotation
3
1) This Servopack provides a reverse rotation mode in which the direction of rotation can be reversed without altering the servomotor wiring. With the standard setting, forward rotation is defined as counterclockwise (CCW) rotation when viewed from the drive end.
2) If reverse rotation mode is used, the direction of motor rotation can be reversed without other items being changed. The direction (+/) of axial motion is reversed.
Standard Setting Reverse Rotation Mode
Forward Run Reference
Reverse Run Reference
Encoder output from Servopack
(Phase A)
(Phase B)
Encoder output from Servopack
(Phase A)
(Phase B)
Encoder output from Servopack
(Phase A)
(Phase B)
Encoder output from Servopack
(Phase A)
(Phase B)
52
3.1 Setting User Constants According to Machine Characteristics
3) Setting Reverse Rotation Mode:
Reverse rotation mode can be set in either of the following two ways. Normally, method 1 is easier to use.
Method 1: Setting Memory Switch
a)
Set bit 0 of memory switch Cn-02 to select reverse rotation mode.
Cn-02 Bit 0 Rotation Direction
Selection
Factory Setting: 0
Set the direction of rotation.
Setting Meaning
Forward rotation is defined as
0
counterclockwise rotation when viewed from the drive end.
Forward rotation is defined as clockwise
1
rotation when viewed from the drive end.
(Standard
setting)
(Reverse
rotation
mode)
b) Method 2: Shorting the Wiring in the 2CN Connector
Reverse rotation mode can be set for the 2CN connector for the encoder. This method is used to standardize user constant settings without using the memory switch.
In this case, reverse rotation mode is set regardless of the memory switch setting.
Servopack Servomotor
For Speed/Torque Control and Position Control
3
Encoder
Servopack
Short 2CN-1 and 2CN-7 in the 2CN connector.
2CN
53
APPLICATIONS OF Σ-SERIES PRODUCTS
3.1.2 Setting the Overtravel Limit Function
3.1.2 Setting the Overtravel Limit Function
1) The overtravel limit function forces the moving part of the machine to stop when it ex­ceeds the movable range.
2) To use the overtravel limit function, connect the following input signal terminals correctly.
3
Forward Rotation Prohibited
Input P-OT 1CN-42
Input N-OT 1CN-43
(Forward Overtravel)
Reverse Rotation Prohibited (Reverse Overtravel)
Inputs terminals for overtravel limit switch.
For linear motion, connect a limit switch to prevent damage to the machine.
P-OT
N-OT
ON: 1CN-42 is at low level.
OFF: 1CN-42 is at high level.
ON: 1CN-43 is at low level.
OFF: 1CN-43 is at high level.
Forward rotation allowed. Normal operation status.
Forward rotation prohibited (reverse rotation allowed).
Reverse rotation allowed. Normal operation status.
Reverse rotation prohibited (forward rotation allowed).
Reverse rotation side
Servomotor
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
Forward rotation side
Limit switch
Servopack
(1CN42)
(1CN43)
54
3.1 Setting User Constants According to Machine Characteristics
3) Use the following user constants (memory switch) to specify whether input signals for overtravel are to be used.
Cn-01 Bit 2
Cn-01 Bit 3
Use of P-OT Input Signal Factory
Setting: 0
Use of N-OT Input Signal Factory
Setting: 0
Specifies whether the P-OT input signal for pro­hibiting forward rotation at overtravel (1CN-42) is to be used and whether the N-OT input signal for prohibiting reverse rotation at overtravel (1CN-43) is to be used.
Specifies “1” when external short-circuit wiring is to be omitted.
Bit Setting Meaning
Uses the P-OT input signal for prohibiting forward rotation. (Forward
0
rotation is prohibited when 1CN-16 is open. Forward rotation is allowed
Bit 2
Bit 3
when 1CN-42 is at 0 V.)
Does not use the P-OT input signal for prohibiting forward rotation.
1
(Forward rotation is always allowed. This has the same effect as shorting 1CN-42 to 0 V.)
Uses the N-OT input signal for prohibiting reverse rotation. (Reverse
0
rotation is prohibited when 1CN-17 is open. Reverse rotation is allowed when 1CN-43 is at 0 V.)
Does not use the N-OT input signal for prohibiting reverse rotation. (Reverse rotation is always allowed. This has the same effect as shorting
1
1CN-43 to 0 V.)
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
Servopack
-42
-43
The short-circuit wiring shown in the figure can be omitted when P-OT and N-OT are not used.
3
4) If the P-OT and N-OT input signals are used, set the following user constants to specify how to stop the motor.
Cn-01 Bit 8
Cn-01 Bit 9
Inputs signal for prohibiting forward rotation
(P-OT, 1CN-42)
Inputs signal for prohibiting reverse rotation
(N-OT, 1CN-43)
Specify how to stop the motor when either of the above signals is input.
How to Stop Motor at Overtravel
Operation to be Performed when Motor Stops after Overtravel
Factory Setting: 0
Factory Setting: 0
Overtravel
0
Bit 8
1
For Speed Control and Position Control
For Speed Control and Position Control
Stop mode After stop
Stop by
0
Bit 6
1
dynamic brake
Coasting to a stop
Deceleration stop
Releasing dynamic brake
Releasing
0
dynamic brake Servo OFF
Bit 9
Zero-clamp
1
55
3
APPLICATIONS OF Σ-SERIES PRODUCTS
3.1.2 Setting the Overtravel Limit Function cont.
Setting Meaning
0 Cn-01 bit 8
1
If deceleration stop mode is selected, specify the operation to be done after the motor stops.
Setting Meaning
Cn-01 bit 9
0
1
If torque control mode is selected, the motor stops in the same way as when the servo is turned OFF, regardless of the setting of Cn-01 bit 8.
Stops the motor in the same way as when the servo is turned OFF.
The motor is stopped by dynamic brake or coasts to a stop. Either of these stop modes can be selected by setting bit 6 of Cn-01.
Stops the motor by decelerating it with the preset torque.
Preset value: Cn-06 (EMGTRQ) emergency stop torque
Turns the servo OFF when the motor stops in deceleration stop mode.
Causes the motor to enter zero-clamp status after it stops in deceleration stop mode.
Cn-06
EMGTRQ Emergency Stop Torque
Unit:%Setting
Range: 0 to Maximum Torque
Specifies the stop torque to be applied at overtra­vel when the input signal for prohibiting forward or reverse rotation is to be used.
Specifies a torque value in terms of a percentage of the rated torque.
Cn-01 Bit 6
Cn-01 Bit 7
How to Stop Motor at Servo OFF
Operation to Be Performed when Motor Stops after Servo OFF
Factory Setting: 0
Factory Setting: 1
The Servopack enters servo OFF status when:
Servo ON input signal (S-ON, 1CN-40) is turned OFF.
Servo alarm arises.
Main power is turned OFF.
Specify how to stop the motor when one of the above events occurs during operation.
Setting Meaning
0 Cn-01 bit 6
Stops the motor by dynamic brake.
Causes the motor to coast to a stop.
1
The motor power is OFF and stops due to machine friction.
Factory Setting: Maximum
For Speed/Torque Control and Position Control
Torque
Input signal for prohibiting forward rotation P-OT (1CN-42)
Input signal for prohibiting reverse rotation N-OT (1CN-43)
Memory switch
Emergency stop torque
Stop by dynamic brake
Coasting to a stop
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
Servo OFF
Stop mode
Stop by dynamic brake
0
Bit 6
1
Coasting to a stop
Dynamic brake is a function that electrically applies brakes by using a resistor to consume motor rotation energy.
After stop
Releasing dynamic brake
0
Bit 7
Holding dynamic brake
1
Remains being released dynamic brake
56
If dynamic brake stop mode is selected, specify the operation to be performed when the
Cn-01
motor stops.
Setting Meaning
0
Cn-01 bit 7
Releases dynamic brake after the motor stops.
Does not release dynamic brake even after the motor stops.
1
3.1.3 Restricting Torque
1) The Servopack can provide the following torque control:
D Torque restriction Level 1: To restrict the maximum output torque to
D Torque control Level 3: To always control output torque, not speed
3.1 Setting User Constants According to Machine Characteristics
protect the machine or workpiece
Level 2: To restrict torque after the motor moves the machine to a specified position
3
Level 4: To alternately use speed control and torque control
This section describes how to use levels 1 and 2 of the torque restriction function.
2) How to Set Level 1: Internal Torque Limit
The maximum torque is restricted to the values set in the following user constants.
Cn-08
Cn-09
TLMTF Forward Rotation Torque Limit
TLMTR Reverse Rotation Torque Limit
Setting
Unit:
Range: 0 to
%
Maximum Torque
Unit:%Setting
Range: 0 to Maximum Torque
Factory Setting: Maximum Torque
Factory Setting: Maximum Torque
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
57
APPLICATIONS OF Σ-SERIES PRODUCTS
Output)
Control
3.1.3 Restricting Torque cont.
Sets the maximum torque values for forward rotation and reverse rotation, respectively.
Sets these user constants when torque must be restricted according to ma­chine conditions.
This torque restriction function always monitors torque, and outputs the signal shown on the right when the limit value is reached.
Specifies a torque limit value in terms of a percentage of the rated torque.
Example of Use: Machine Protection
Output Signal for Torque Restric­tion Function
D CLT
+ (1CN-25), CLT- (1CN-26)
D Status indication mode bit data
D Monitor mode (Un-05) bit 4
User Constant Setting:
Memory switch (Cn-01) bit 4 = 0
3
Speed
Torque limit
Motor speed
Note that too small a torque limit val­ue will result in torque shortage at ac­celeration or deceleration.
Torque
Using CLT
+, CLT- Signals
This section describes how to use contact output signals CLT output signal.
Servopack
Photocoupler Output
Per output:
Maximum operation voltage: 30 VDC
Maximum output current: 50 mA DC
1CN-25
1CN-26
CLT
CLT
+
-
+, CLT- as a torque limit
I/O power supply
+24V
Output CLT+ 1CN-25 Output CLT- 1CN-26
This signal indicates whether motor output torque (current) is being restricted.
ON status: The circuit between 1CN-25 and 1CN-26 is closed. 1CN-25 is at low level.
OFF status: The circuit between 1CN-25 and 1-CN26 is open. 1CN-25 is at high level.
58
Torque Limit Output (Running
Motor output torque is being restricted. (Internal torque reference is greater than the preset value.)
Motor output torque is not being restricted. (Internal torque reference is equal to or below the preset value.)
For Speed/Torque
3.1 Setting User Constants According to Machine Characteristics
0
Preset Value: Cn-08 (TLMTF)
Cn-09 (TLMTR) Cn-18 (CLMIF) : P-CL Cn-19 (CLMIR) : N-CL
input only input only
Note This function is changed to another function depending on the setting of bit 4 of
memory switch Cn-01.
To use output signals CLT
+, CLT- as a torque limit output signal, set the following memory
switch to 0.
This memory switch can also be used to set level 2 torque restriction (described in the next subsection).
Cn-01 Bit 4
CLT+, CLT-
Selection
Output Signals
Factory Setting: 0
For Speed/Torque Control
Sets the output conditions for output signals CLT+ (1CN-25) and CLT- (1CN-26).
Setting Meaning
Uses CLT+, CLT- output signals as a torque limit output signal.
Compares the DR2 Servopack internal torque (current) reference with the preset value.
Preset Value:Cn-08 (TLMTF)
Cn-09 (TLMTR) Cn-18 (CLMIF): P-CL input only Cn-19 (CLMIR): N-CL input only
Internal torque (current) reference
preset value
Internal torque (current) reference < preset value
Opens the circuit between 1CN-25 and 1CN-26
Closes the circuit between 1CN-25 and 1CN-26
Uses CLT+, CLT- output signals as a speed coincide output signal.
1
For details, refer to 3.7.4.
Bit 4 of memory switch Cn-01
Torque limit detection
Speed coincide
When CLT+, CLT- output signals are changed, the following bit data are also changed:
Status indication mode bit data
Monitor mode Un-05 bit 4
CLT+ CLT-
(1CN-25) (1CN-26)
3
59
APPLICATIONS OF Σ-SERIES PRODUCTS
P-CL
3.1.3 Restricting Torque cont.
How to Set Level 2: External Torque Limit
3)
3
First, use a contact input signal to make thetorque (current) limit value set in the user constant valid. Torque limit can be set separately for forward and reverse rotation.
To use this function, always set bit 2 of memory switch Cn-02 to 0 (standard setting). The contact input speed control function cannot be used.
N-CL
ON: 1CN-45 is at low level.
OFF: 1CN-45 is at high level.
ON: 1CN-46 is at low level.
OFF: 1CN-46 is at high level.
Torque restriction applies during forward rotation. Limit value:
Torque restriction does not apply during forward rotation.
Torque restriction applies during reverse rotation. Limit value:
Torque restriction does not apply during reverse rotation.
1CN-45
1CN-46
Forward rotation
Reverse rotation
Servopack
Without torque limit
Speed
With torque limit
Speed
Without torque limit
Speed
With torque limit
Speed
Torque
Torque
Torque
Torque
Cn-18
Cn-19
This torque restriction function outputs the signal shown on the right.
Examples of Use:
D
Forced stopping
D
Holding workpiece by robot
Output Signal for Torque Restriction Function
CLT+ (1CN-25), CLT- (1CN-26)
Status indication mode bit data
Monitor mode Un-05 bit 4
User Constant Setting: Memory switch Cn-01 bit 4 = 0
60
3.1 Setting User Constants According to Machine Characteristics
Cn-18
CLMIF Forward External Torque Limit
Unit:%Setting
Range: 0 to Maximum
Factory Setting: 100
For Speed/Torque Control and Position Control
Torque
Cn-19
CLMIR Reverse External Torque Limit
Unit:%Setting
Range: 0 to Maximum
Factory Setting: 100
For Speed/Torque Control and Position Control
Torque
Sets a torque limit value when torque is restricted by external contact input.
This function is valid when bit 2 of memory switch Cn-02 is set to 0.
When P-CL (1CN-45) is input Applies torque restriction as specified in Cn-18
When N-CL (1CN-46) is input Applies torque restriction as specified in Cn-19
For torque restriction by analog voltage reference, refer to
by Analog Voltage Reference
Using P-CL
and N-CL Signals
.
This section describes how to use input signals P-CL
3.2.9 Using Torque Restriction
and N-CL as torque limit input sig-
nals.
3
I/O power supply
1CN
-47
+24VIN
Host controller
P-CL
N-CL
-45
-46
Forward External Torque Limit
Input P-CL 1CN-45
Input (Speed Selection 1)
Reverse External Torque Limit
Input N-CL 1CN-46
Input (Speed Selection 2)
These signals are for forward and reverse exter­nal torque (current) limit input.
This function is useful in forced stopping.
Servopack
4.7k
5mA
Photocoupler
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
Output Signal for Torque Restriction Function
+ (1CN-25), CLT- (1CN-26)
CLT
Status indication mode bit data
Monitor mode Un-05 bit 4
User Constant Setting:
Memory switch Cn-01 bit 4 = 0
61
APPLICATIONS OF Σ-SERIES PRODUCTS
P-CL
3.1.3 Restricting Torque cont.
3
N-CL
ON: 1CN-45 is at low level.
OFF: 1CN-45 is at high level.
ON: 1CN-46 is at low level.
OFF: 1CN-46 is at high level.
Torque restriction applies during forward rotation. Limit value:
Cn-18
Torque restriction does not apply during forward rotation. Normal operation status.
Torque restriction applies during reverse rotation. Limit value:
Cn-19
Torque restriction does not apply during reverse rotation. Normal operation status.
The signal shown on the right is output while torque is being restricted.
Note This function is changed to another function depending on the setting of bit 2 of
memory switch Cn-02 (see below).
To use input signals P-CL
and N-CL as torque limit input signals, set the following
memory switch to 0.
Cn-02 Bit 2
Contact Input Speed Control Selection
Prohibits the contact input speed control function.
If the contact input speed control function is used, the contents of the input signals shown below will change.
Factory Setting: 0
For Speed/Torque Control and Position Control
Servopack
Run the motor at internally set speed
Contact input
Servomotor
After this memory switch is reset, the meanings of the following signals will also change:
Monitor mode (Un-05) bit 7 and bit 8
Setting Meaning Input Signal
Used to switch between P control and
Does not use
P-CON (1CN-41)
the contact
0
input speed control
(1CN-45) Used for forward external torque limit
P-CL
function.
(1CN-46) Used for reverse external torque limit
N-CL
P-CON P-CL N-CL Speed Setting
Uses the contact
1
input speed control function.
Direction of rotation
0: Forward 1: Reverse
PI control. (For speed/torque control, bits A and B of Cn-01 take precedence over this signal.)
input
input
0: OFF, 1: ON
00
01
11
10
Normal speed/torque or position control
Cn-1F (SPEED1)
Cn-20 (SPEED2)
Cn-21 (SPEED3)
62
3.1 Setting User Constants According to Machine Characteristics
Handling of the CLT Refer to Using CLT
+, CLT- signals are the same as for level 1 (internal torque limit).
+, CLT- Signals on page 58.
3
63
3
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.1 Inputting Speed Reference
3.2 Setting User Constants According to Host Controller
This section describes how to connect a Σ-series Servo to a host controller and how to set user constants.
3.2.1 Inputting Speed Reference 64........................................
3.2.2 Inputting Position Reference 69......................................
3.2.3 Using Encoder Output 76............................................
3.2.4 Using Contact I/O Signals 80.........................................
3.2.5 Using Electronic Gear 82............................................
3.2.6 Using Contact Input Speed Control 86.................................
3.2.7 Using Torque Control 91.............................................
3.2.8 Using Torque Feed-forward Function 97...............................
3.2.9 Using Torque Restriction by Analog Voltage Reference 98................
3.2.10 Using the Reference Pulse Inhibit Function (INHIBIT) 100.................
3.2.11 Using the Reference Pulse Input Filter Selection Function 101.............
3.2.12 Using the Analog Monitor 102.........................................
3.2.1 Inputting Speed Reference
1) Using the following memory switch, select the speed/torque control.
Cn-02 Bit B
Select the control mode (speed/torque control or position control) by bit B of memory switch Cn-02.
Setting Meaning
Selects speed or torque control.
0
Select the control form by bits A and B of memory switch Cn-01.
1 Selects position control.
Note For the memory switch Cn-02, always turn the power OFF and then ON after
changing the setting. This makes the new setting valid.
2) Input a speed reference by using the following input signal “speed reference input.” Since this signal can be used in different ways, set the optimum reference input for the system to be created.
Selection of Speed/Torque Control or Position Control
Factory Setting: 0
For Speed/Torque Control and Position Control
Servopack
64
Torque reference input (analog voltage input)
Speed reference input (analog voltage input)
1CN-9
1CN-10
1CN-5
1CN-6
P: Represents twisted-pair cables
Torque reference
Speed reference
3.2 Setting User Constants According to Host Controller
Input V-REF 1CN-5
Input SG-V 1CN-6
Use these signals when speed control is selected (memory switch Cn-02 bit B = 0).
For ordinary speed control, always wire the V­REF and SG-V terminals.
Motor speed is controlled in proportion to the input voltage between V-REF and SG-V.
Speed Reference Input For Speed/Torque
Control Only
Signal Ground for Speed Reference Input
Reference speed
Standard setting
For Speed/Torque Control Only
4500
3000
1500
Input voltage (V)
-1500
-3000
-4500
Set the slope in Cn-03 (VREFGN).
Standard Setting:
Cn-03 = 500: This setting means that 6 V is equivalent to rated speed (3,000 r/min)
Examples: +6 V input 3000 r/min in forward direction +1 V input 500 r/min in forward direction
3 V input 1500 r/min in reverse direction
User constant Cn-03 can be used to change the voltage input range.
3
Example of Input Circuit (See the figure on the right)
For noise control, always use twisted-pair cables.
Recommended Variable Resistor for Speed Setting: Type 25HP-10B manufactured by Sakae Tsushin Kogyo Co., Ltd.
When position control is performed by a host con­troller such as a programmable controller.
Connect V-REF and SG-V to speed reference
Host controller Servopack
Speed reference output terminals
output terminals on the host controller. In this case, adjust Cn-03 according to output voltage specifications.
Output +15V 1CN-23
Output -15V 1CN-24
+15V power supply for speed/torque control
-15V power supply for speed/torque control
Feedback pulse input terminals
P: Represents twisted-pair cables
Servopack
1CN-5
1CN-6
1CN-33 1CN-34 1CN-35 1CN-36
For Speed/Torque Control Only
For Speed/Torque Control Only
Power output for speed/torque control. Max. output current is 30mADC.
65
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.1 Inputting Speed Reference cont.
3) Use the memory switch and input signal P-CON to specify one of the four modes shown below.
3
Cn-01 Bit A Control Mode Selection Factory
Setting: 0
Cn-01 Bit B Control Mode Selection Factory
Setting: 0
The Servopack for speed/torque control provides four different control modes.
For Speed/Torque Control Only
For Speed/Torque Control Only
66
Cn-01
Control
Mode
0
1
Setting
Bit B Bit A
3.2 Setting User Constants According to Host Controller
Control Mode
Speed Control
This is normal speed control.
D Speed reference is input from V-REF
(1CN-5).
Speed reference
P/PI changeover
DR2 Servopack
V-REF
(1CN-5)
P-CON
(1CN-41)
0 0
D P-CON
(1CN-41) signal is used to switch
between P control and PI control.
1CN-41 is
PI control
open
1CN-41 is
P control
at 0 V
D Torque reference input T-REF (1CN-9)
cannot be used.
Zero-clamp Speed Control
This speed control allows the zero-clamp function to be set when the motor stops.
D Speed reference is input from V-REF
(1CN-5).
D P-CON
(1CN-41) signal is used to turn the
zero-clamp function ON or OFF.
1CN-41 is open
Turns zero-clamp function OFF
DR2 Servopack
Speed reference
Zero-clamp
Zero-clamp is performed when the following two conditions are met:
Condition 1: P-CON ON.
Condition 2: Motor speed drops below the preset value.
Preset value: Cn-29 (ZCLVL)
V-REF
(1CN-5)
P-CON
(1CN-41)
is turned
3
1 0 Torque control I
1 1 Torque control II
For torque control, refer to 3.2.7 Using Torque Control.
1CN-41 is at 0 V
Turns zero-clamp function ON
D Torque reference input T-REF (1CN-9)
cannot be used.
67
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.1 Inputting Speed Reference cont.
3
Using P-CON
Signal:
Proportional Control, etc. For Speed/Torque
Input P-CON 1CN-41
Control and Position Control
The function of input signal P-CON changes with the memory switch setting.
Servopack
Switching between P control and PI control
Switching between zero-clamp enabled mode and zero-clamp prohibited mode
Switching between torque control and speed control
Memory Switch
Cn-02
Bit 2
Cn-01
Bit B
0 0 0
0 0 1
0 1 0
0 1 1
1
Cn-01
Bit A
Memory switch
Switching between proportional (P) control and proportional/integral (PI) control
Switching between zero-clamp enabled/prohibited mode Speed control with zero-clamp function
Torque control I (P-CON is not used.)
Switching between torque control and speed control (Torque control II)
Changing the direction of rotation during contact input speed control
Changing the direction of rotation
Meaning of P-CON Signal
TERMS
4) Adjust the speed reference gain using the following user constant.
Cn-03
VREFGN Speed Reference Gain
Unit: (r/min)/V
Setting Range: 10 to 2162
Factory Setting: 500
For Speed/Torque Control Only
This user constant is for speed/torque control only. Sets the voltage range for speed reference input V-REF (1CN-5). Sets this user constant ac-
Reference speed (r/min)
Set this slope.
cording to the output form of the host controller or external circuit.
Reference voltage (V)
The factory setting is as follows: Rated speed (3000 r/min)/6 V = 500
Zero-clamp function
This function is used for a system in which the host controller does not form a position loop. In this case, the stopping position may shift even if a speed reference is set to 0. If the zero­clamp function is turned ON, a position loop is internally formed so that the stopping position is firmly “clamped.”
68
3.2.2 Inputting Position Reference
1) Using the following memory switch, select the position control.
3.2 Setting User Constants According to Host Controller
Positions
Cn-02 Bit B
Selection of Speed/Torque Control or Position Control
Factory Setting: 0
For Speed/Torque Control and Position Control
Select the control mode (speed/torque control or position control) by bit B of memory switch Cn-02.
Setting Meaning
Selects speed or torque control.
0
Select the control form by bits A and B of memory switch Cn-01.
1 Selects position control.
Note For the memory switch Cn-02, always turn the power OFF and then ON after
changing the setting. This makes the new setting valid.
2) Input a position reference by using the following input signal “reference pulse input.” Since there are several specifications for input signal, select reference input for the sys­tem to be created.
Inputs a move reference by pulse input.
Position reference can correspond to the following three types of out­put form:
Line driver output
Reference pulse input
Reference sign input
Error counter clear input
Servopack
PHOTOCOUPLER
3
+12V Open collector output
+5V Open collector output
Connection Example 1: Line Driver Output
Line Driver Used:
SN75174 manufactured by Texas Instruments Inc., or MC3487 or equivalent.
P: Represents twisted-pair cables
Host controller
Line driver
1CN-7
1CN-8
1CN-11
1CN-12
1CN-15
1CN-14
Servopack
Photocoupler
69
APPLICATIONS OF Σ-SERIES PRODUCTS
Ref
Control
Onl
3.2.2 Inputting Position Reference cont.
Connection Example 2: Open Collector Output
3
Sets the value of limiting re-
Host controller Servopack
sistor R1 so that input cur­rent i falls within the following range:
i
Input Current i: 7 to 15 mA
Examples:
When Vcc is 12 V, R1 = 1 k
When Vcc is 5 V, R1 = 180
P: Represents twisted-pair cables
Note The signal logic for open collector output is as follows.
When Tr1 is ON Equivalent to high level input
When Tr1 is OFF Equivalent to low level input
Output PL1 1CN-3
Power for Open Collector
erence
Output PL2 1CN-13
1CN-7
1CN-8
1CN-11
1CN-12
1CN-15
1CN-14
For Position
Photocoupler
y
Output PL3 1CN-18
For details, refer to the Connection Example 3 (When Power for Open Collector Refer­ence is Used) shown below:
70
3.2 Setting User Constants According to Host Controller
Connection Example 3: When Power for Open Collector Reference is Used
When power for open collec-
Host controller
tor reference (PL1, PL2, PL3) is used, connect be­tween PL1 and PULS, PL2 and SIGN, PL3 and CLR as follows:
P: Represents twisted-pair cables
Note The signal logic for open collector output is as follows.
When Tr1 is ON Equivalent to high level input
When Tr1 is OFF Equivalent to low level input
Servopack
Photo­coupler
3
3) Use the following memory switch to select the reference pulse form to be used:
Input PULS 1CN-7
Input£PULS 1CN-8
Input SIGN 1CN-11
Input£SIGN 1CN-12
Reference Pulse Input For Position Control Only
Reference Pulse Input For Position Control Only
Reference Sign Input For Position Control Only
Reference Sign Input For Position Control Only
The motor only rotates at an angle proportional to the input pulse.
Cn-02 Bit 3
Cn-02 Bit 4
Cn-02 Bit 5
Reference Pulse Form Selection
Reference Pulse Form Selection
Reference Pulse Form Selection
Sets the form of a reference pulse that is external­ly output to the Servopack.
Sets the pulse form according to the host control­ler specifications.
Factory Setting: 0
Factory Setting: 0
Factory Setting: 0
For Position Control Only
For Position Control Only
For Position Control Only
Host controller
Position reference pulse
Servopack
(1CN-7)
(1CN-11)
Set also the input pulse logic in bit D of Cn-02.
71
APPLICATIONS OF Σ-SERIES PRODUCTS
Pul
MotorF
d
MotorR
(
(Posi
with
setting)
dif
fer
(Neg
(Nega
with
setting)
dif
fer
3.2.2 Inputting Position Reference cont.
3
Bit D
0
Posi-
tive
logic
setting)
1
a-
tive
logic
setting)
Cn-02
Bit5Bit4Bit
0 0 0
0 1 0
0 1 1
1 0 0
0 0 1
0 0 0
0 1 0
0 1 1
1 0 0
3
Input
se
Multipli-
er
¢1
¢2
¢4
¢1
¢2
¢4
Refer-
ence
Pulse
Form
Sign + pulse train
Two­phase pulse train with 90° phase differ­ence
*1
CW pulse + CCW pulse
Sign + pulse train
Two­phase pulse train with 90° phase differ­ence
orwar
Run Reference
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
everse
Run Reference
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
0 0 1
*1 When CW pulse + CCW pulse and positive logic setting, make sure to set each of the
signals (the one not being input the pulse) to Low level.
*2 When CW pulse + CCW pulse and negative logic setting, make sure to set each of the
signals (the one not being input the pulse) to High level.
72
*2
CW pulse + CCW pulse
(1CN-7)
(1CN-11)
(1CN-7)
(1CN-11)
3.2 Setting User Constants According to Host Controller
Input Pulse Multiply Function:
When the reference form is two-phase pulse train with 90° phase difference, the input pulse multiply function can be used.
The electronic gear function can also be used to convert input pulses.
Example of I/O Signal Generation Timing
Number of motor move pulses
(1CN-7)
(1CN-11)
x4
x2
x1
Input reference pulse
Servo ON
Base block
Sign + pulse train
PG pulse
Release
t4, t5, t6 2ms
t7 20 μs
Note The interval from the time the servo ON signal is turned ON until a reference pulse is
input must be at least 40 ms. Otherwise, the reference pulse may not be input. The error counter clear (CLR) signal must be ON for at least 20 μs. Otherwise, it be­comes invalid.
t1 30 ms
t2 6ms (When user constant Cn-12 is set to 0)
t3 40 ms
3
73
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.2 Inputting Position Reference cont.
Allowable Voltage Level and Timing for Reference Pulse Input
Reference Pulse Form Electrical Specifications Remarks
Sign + pulse train input (SIGN + PULS signal)
Maximum reference frequency: 450 kpps
The signs for each reference pulse are as follows:
¨: High level ©: Low level
¨ reference © reference
3
90° different two-phase pulse train
Phase A
Phase B
(phase A + phase B)
Maximum reference frequency x 1 multiplier: 450 kpps x 2 multiplier:
Phase B is 90° forward from phase B
Phase B is 90° behind phase B
400 kpps x 4 multiplier: 200 kpps
CCW pulse + CW pulse
Maximum reference
CCW pulse
CW pulse
frequency: 450 kpps
¨ reference © reference
4) The following describes how to clear the error counter.
User constant Cn-02 (bits 3, 4 and 5) is used to switch the input pulse multiplier mode.
Input CLR 1CN-15
Input£CLR 1CN-14
Setting the CLR signal to high level does the fol­lowing:
Sets the error counter inside the Servopack to 0.
Prohibits position loop control.
Use this signal to clear the error counter from the host controller.
Bit A of memory switch Cn-02 can be set so that the error counter is cleared only once when the leading edge of an input pulse rises.
74
Error Counter Clear Input For Position
Control Only
Error Counter Clear Input For Position
Control Only
Servopack
Clear
Position loop error counter
3.2 Setting User Constants According to Host Controller
Cn-02 Bit A
Error Counter Clear Signal Selection
Factory Setting: 0
For Position Control Only
Selects the pulse form of error counter clear signal CLR (1CN-15).
Setting Meaning
Clears the error counter when the CLR signal is set at high level. Error pulses
0
do not accumulate while the signal remains at high level.
Clears the error counter only once when the rising edge of the CLR signal rises.
1
Cn-01 Bit A
Error Counter Processing at Servo OFF
Factory Setting: 0
(1CN-15)
(1CN-15)
Cleared only once at this point
For Position Control Only
Select the error counter processing at Servo OFF.
Cleared state
3
Setting Meaning
0
Error counter is cleared at Servo OFF.
1 Error counter is not cleared at servo OFF.
75
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.3 Using Encoder Output
3.2.3 Using Encoder Output
1) Encoder output signals divided inside the Servopack can be output externally. These
signals can be used to form a position control loop in the host controller.
This output is explained here.
3
Host controller
Servomotor encoder
Phase A Phase B Phase C
Servopack
Frequency dividing
circuit
The output circuit is for line driver output. Connect each signal line according to the fol­lowing circuit diagram.
Host controller
Line receiver
4
12
D
Phase A
Phase B
Phase C
Choke coil
Phase A
Phase B
Phase C
Servopack
(1CN-33)
(1CN-34)
(1CN-35)
(1CN-36)
(1CN-19)
(1CN-20)
P: Represents twisted-pair cables
TERMS
Divided (or dividing)
“Dividing” means converting an input pulse train from the encoder mounted on the motor according to the preset pulse density and outputting the converted pulse. The unit is pulses per revolution.
76
(1CN-1)
(1CN-50)
SG
FG
Smoothing capacitor
Line receiver used: SN75175 manufactured by
Texas Instruments Inc. or
MC3486 (or equivalent) R (termination resistor): 220 to 470 C (decoupling capacitor): 0.1 μF
2) I/O signals are described below.
3.2 Setting User Constants According to Host Controller
Output PAO 1CN-33
Output £PAO 1CN-34
Output PBO 1CN-35
Output £PBO 1CN-36
Output PCO 1CN-19
Output £PCO 1CN-20
Encoder Output Phase-A
Encoder Output Phase-A
Encoder Output Phase-B
Encoder Output Phase-B
Encoder Output Phase-C
Encoder Output Phase-C
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
Divided encoder signals are output.
Always connect these signal terminals when a position loop is formed in the host control­ler to perform position control.
Set a dividing ratio in the following user constant.
Dividing ratio setting Cn-0A PGRAT
The dividing ratio setting is not relevant to the gear ratio setting (Cn-24, 25) for the electronic gear function of the Servopack for position control.
3
Output Phase Form
(Incremental Encoder)
Forward rotation Reverse rotation
Phase A
Phase B
Phase C
(Absolute Encoder)
Forward rotation Reverse rotation
Phase A
Phase B
Phase C
Phase A
Phase B
Phase C
Phase A
Phase B
Phase C
77
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.3 Using Encoder Output cont.
3
Input SEN 1CN-4
Input 0SEN 1CN-2
Output PSO 1CN-48
Output £PSO 1CN-49
Input BAT¨ 1CN-21
Input BAT© 1CN-22
SEN Signal Input For Speed/Torque Control
SEN Signal Input For Speed/Torque Control
Encoder Output Phase-S
Encoder Output Phase-S
Battery (+) For Speed/Torque Control
Battery (−) For Speed/Torque Control
and Position Control
and Position Control
For Speed/Torque Control
and Position Control
For Speed/Torque Control
and Position Control
and Position Control
and Position Control
Use these signals (SEN to BAT©) for absolute encoders. For details, refer to 3.8.5 Using an Absolute Encoder.
Output SG 1CN-1
Output FG 1CN-50
Signal Ground for Encoder Output
Frame Ground For Speed/Torque Control
For Speed/Torque Control
and Position Control
and Position Control
SG: Connect to 0 V on the host controller. FG: Connect to the cable shielded wire.
3) Use the following memory switch to specify the type of the encoder to be used.
Cn-02 Bit 9
Encoder Type Selection Factory
Setting: 0
For Speed/Torque Control and Position Control
Sets the encoder type according to the servomotor type as shown in the table.
After changing the memory switch setting, always turn the power OFF, then ON.
Motor Type Encoder Type Setting
SGM-jjj31j SGMP-jjj31j
SGM-jjjW1j SGMP-jjjW1j
Incremental encoder
Absolute encoder
0
1
78
3.2 Setting User Constants According to Host Controller
4) Set the pulse dividing ratio in the following user constant.
PGRAT Dividing Ratio Setting
Cn-0A
Unit: P/R
Setting Range: 16 to No. of
Factory Setting: 2048
For Speed/Torque Control and Position
Control Encoder Pulses
Sets the number of output pulses for PG output
£
signals (PAO,
PAO, PBO and£PBO).
Pulses from motor encoder (PG) are divided by
Servomotor encoder
Servopack
Frequency dividing
Output terminals: PAO (1CN-33)
£PAO (1CN-34)
PBO (1CN-35)
£PBO (1CN-36)
Phase A
Phase B
the preset number of pulses before being output.
The number of output pulses per revolution is set in this user constant. Set this value ac­cording to the reference unit of the machine or controller to be used.
The setting range varies according to the encoder used.
Setting example:
Motor Type Number of Encoder Pulses Per Revolution Setting Range
SGM-jjj31j
Incremental encoder: 2048 pulses per revolution 16 to 2048
SGMP-jjj31j
SGM-jjjW1j
Absolute encoder: 1024 pulses per revolution 16 to 1024
SGMP-jjjW1j
Preset value: 16
1 revolution
3
For the user constant Cn-0A, always turn the power OFF and then ON after chang­ing the setting. This makes the new setting valid.
79
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.4 Using Contact I/O Signals
3.2.4 Using Contact I/O Signals
1) Contact Input Signal Terminal Connections
These signals are used to control DR2 Servopack operation. Connect these signal termi­nals as necessary.
I/O power supply
Host controller
1CN-47
1CN-45
1CN-46
1CN-40
Servopack
Photocoupler
3
1CN-41
1CN-42
1CN-43
1CN-44
Note Provide an external I/O power supply separately.
There are no power terminals to which the DR2 Servopack outputs signals exter­nally.
External Power Supply: 24 1 VDC 50 mA or more
Yaskawa recommends that this external power supply be the same type as for the output circuit.
I/O Power Supply For Speed/Torque
Input +24VIN 1CN-47
Control and Position Control
This external power supply input terminal is com­mon to the following contact input signals:
Contact Input Signals: P-CL
80
(1CN-45) N-CL S-ON P-CON
(1CN-46)
(1CN-40)
(1CN-41) P-OT (1CN-42) N-OT (1CN-43) ALMRST
(1CN-44)
Servopack
I/O power supply
1CN-47
Connect an external I/O power supply.
3.2 Setting User Constants According to Host Controller
2) Contact Output Signal Terminal Connections
These output signals are used to indicate DR2 Servopack operation status.
Photocoupler output
Per output
Maximum operational voltage: 30 VDC Maximum output current: 50 mA DC
Open collector output
Per output
Maximum operational voltage: 30 VDC Maximum output current: 20 mA DC
Servopack
Photocoupler
Host controller
Note Provide an external I/O power supply separately.
There are no power terminals to which the DR2 Servopack outputs signals exter­nally. Yaskawa recommends that this external power supply be the same type as for the input circuit.
I/O power supply
3
Output SG 1CN-2
Signal Ground for Alarm Code Output Signal
For Speed/Torque Control and Position Control
This signal ground is used for the following output signals. Connect to 0 V on the external power supply.
Contact Output Signals: ALO1 (1CN-37)
ALO2 (1CN-38) ALO3 (1CN-39)
81
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.5 Using Electronic Gear
3.2.5 Using Electronic Gear
For position control only.
1) Outline
3
Positions
The electronic gear function enables the motor travel distance per input reference pulse to be set to any value. It allows the host controller to perform control without having to consider the machine gear ratio and the number of encoder pulses.
When Electronic Gear Function is Not Used
Workpiece
Number of encoder pulses: 2048
To move a workpiece 10 mm,
One revolution is equivalent to 6 mm, so
2048 x 4 (pulses) is equivalent to one revolution, so
A total of 13653 pulses must be input as a reference.
the host controller needs to make this calculation.
Setting the Electronic Gear
2)
10 6 = 1.6666 (revolutions)
1.6666 x 2048 x 4 = 13653 (pulses)
Ball screw pitch: 6 mm
When Electronic Gear Func­tion is Used
Workpiece
Number of encoder pulses: 2048
Machine conditions and reference unit must be defined for the electronic gear function beforehand.
To move a workpiece 10 mm:
Reference unit is 1 μm, so 10 mm 1 μm = 10000 pulses
Reference unit: 1 μm
Ball screw pitch: 6 mm
82
Calculate the electronic gear ratio (B/A) according to the procedure below and set the value in Cn-24 and Cn-25.
a) Check the machine specifications.
Items related to electronic gear:
Gear ratio
Ball screw pitch
Ball screw pitch
Gear ratio
Pulley diameter
b) Check the number of encoder pulses for the SGM Servomotor.
Motor Type Encoder Type Number of Encoder
SGM-jjj31j SGMP-jjj31j
SGM-jjjW1j SGMP-jjjW1j
Incremental encoder 2048
Absolute encoder 1024
Pulses Per Revolution
Same as user constant Cn-11 settings.
c) Determine the reference unit to be used.
3.2 Setting User Constants According to Host Controller
Reference unit is the minimum unit of posi­tion data used for moving the load.
To move a table in 0.001 mm units
Reference unit: 0.001 mm
(Minimum unit of reference from host con­troller)
Examples:
0.01 mm, 0.001 mm, 0.1°, 0.01 inch
Determine the reference unit according to
Reference input of one pulse moves the load
machine specifications and positioning accuracy.
by one reference unit.
Example: When reference unit is 1 μm If a reference of 50,000 pulses is input, the load moves 50 mm (50,000 x 1 μm).
d) Determine the load travel distance per revolution of load shaft in reference units.
Load travel distance per revolution of load shaft (in reference units)
Load travel distance per revolution of load shaft (in unit of distance)
=
Reference unit
Example: When ball screw pitch is 5 mm and reference unit is 0.001 mm
5/0.001 = 5,000 (reference units)
3
Ball Screw Disc Table Belt & Pulley
Load shaft
1 revolution
=
P: Pitch
P
Reference unit
1 revolution
e) Determine the electronic gear ratio
=
B
A
Load shaft
360°
Reference unit
.
Load shaft
1 revolution
D: Pulley diameter
=
Reference unit
If the load shaft makes “n” revolutions when the motor shaft makes “m” revolutions, the gear ratio of motor shaft and load shaft is
B
Electronic gear ratio
Travel distance per revolution of load shaft (in reference units)
=
A
Number of encoder pulses x 4
n
.
m
m
×
n
NOTE Make sure that the electronic gear ratio meets the following condition:
B
0.01 Electronic gear ratio 100
A
If the electronic gear ratio is outside this range, the Servopack does not work properly. In this case, modify the load configuration or reference unit.
π D
83
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.5 Using Electronic Gear cont.
f) Set the electronic gear ratio in the user constants below.
Reduce the electronic gear ratio
integer smaller than 65535, then set A and B in the following user constants.
B
to their lowest terms so that both A and B are an
A
3
B
A
This is all that is required to set the electronic gear.
Cn-24
Cn-25
These user constants are for position control only.
Set the electronic gear ratio according to machine specifications.
Electronic gear ratio
Cn-24 RATB Electronic gear ratio (numerator)
Cn-25 RATA Electronic gear ratio (denominator)
RATB Electronic Gear Ratio (Numerator)
RATA Electronic Gear Ratio (Denominator)
B
A
=
Unit: None
Unit: None
Cn-24 Cn-25
Setting Range: 1 to 65535
Setting Range: 1 to 65535
Factory Setting: 4
Factory Setting: 1
Input reference pulse
For Position Control Only
For Position Control Only
Servopack
Electro­nic gear
Servomotor
B = [(Number of encoder pulses) x 4] x [Motor shaft rotating speed] A = [Load travel distance per revolution of load shaft (Reference unit)] x [Load shaft
rotating speed]
Note that the user constant settings must meet the following condition:
B
0.01
100
A
84
3.2 Setting User Constants According to Host Controller
Examples of Setting an Electronic Gear Ratio for Different Load Mechanisms
3)
Ball Screw
Reference unit: 0.001 mm
Load shaft
Travel distance per revolution of load shaft
Electronic gear ratio
=
B
=
A
6mm
0.001mm
2048 × 4 × 1
6000 × 1
= 6000
=
Cn-24 Cn-25
Incremental encoder: 2048 pulses per revolution
Ball screw pitch: 6 mm
Disc Table
Reference unit:
0.1°
Load shaft
Incremental encoder: 2048 pulses per revolution
Belt & Pulley
Reference unit: 0.0254 mm
Load shaft
Gear ratio:
2.4 : 1
Absolute encoder: 1024 pulses per revolution
Pulley diameter: 100 mm
Gear ratio: 3:1
Travel distance per revolution of load shaft
Electronic gear ratio
Preset values
Travel distance per revolution of load shaft
Electronic gear ratio
=
9830.4 12362
=
49152 61810
Preset values
B
A
3.14 x 100mm
=
B
=
A
Preset values
Cn-24
Cn-25
360°
=
=
Cn-24
Cn-25
0.0254mm
1024 × 4 × 2.4
12362 × 1
= 3600
0.1°
2048 × 4 × 3
3600 × 1
24576
3600
Cn-24
Cn-25
8192
6000
=
= 12362
Cn-24
=
Cn-25
49152
61810
Cn-24 Cn-25
3
4) Control Block Diagram for Servopack for Position Control
DR2 Servopack for position control
Reference pulse
PG signal output
Differ­entiation
Smooth ing
Feed-forw ard gain
Frequency dividing
Error counter
Primary lag filter
Bias
Speed loop
COIN signal
Current loop
SGM Servomotor
Encoder
85
APPLICATIONS OF Σ-SERIES PRODUCTS
3.2.6 Using Contact Input Speed Control
3.2.6 Using Contact Input Speed Control
1) The contact input speed control function provides easy-to-use speed control. It allows the user to initially set three different motor speeds in user constants, select one of the speeds externally by contact input and run the motor.
This function can be used for both speed/torque control and position control.
P-CON
Servopack
1CN-41
3
Contact input
No external speed setting device or pulse generator is required.
P-CL
N-CL
1CN-45
1CN-46
Servomotor
Speed selection
The motor is operated at the speed set in the user constant.
User constants
2) To use the contact input speed control function, perform Steps a) to c).
a) Set the following memory switch to 1.
Cn-02 Bit 2
Contact Input Speed Control Selection
Enables the contact input speed control function.
If the contact input speed control function is used, the contents of the input signals shown be-
Factory Setting: 0
For Speed/Torque Control and Position Control
Servopack
Run the motor at internally
Contact input
set speed
low will change.
Servomotor
When this memory switch is reset, the meanings of the following signals will also change:
Monitor mode (Un-05) bit 7 and bit 8
86
3.2 Setting User Constants According to Host Controller
contact
input
speed
control
p
contact
input
function.
of
the
posi
ype,
type,the
re
p
1:
Reverse
pulse
inhibit
(
)
(INHIBIT)
Setting Meaning Input Signal
Does not use the
0
speed control function.
P-CON(1CN-41) Used to switch between P control and PI
control.
P-CL(1CN-45) Used for forward external torque limit input
N-CL(1CN-46) Used for reverse external torque limit input
Uses the contact in speed control
ut
P-CON P-CL N-CL Speed Setting
function.
Note In the case
1
tion control t
the re-
ferrence
-
-
-
Direction of rotation
0: Forward 1: Reverse
0 0 Stop (or pulse reference)
0 1 Cn-1F, SPEED1
1 1 Cn-20, SPEED2
ulse inhibit
function
1 0 Cn-21, SPEED3
INHIBIT cannot be used.
b) Set three motor speeds in the following user constants.
Cn-1F
Cn-20
Cn-21
SPEED1 1st Speed (Contact Input Speed Control)
SPEED2 2nd Speed (Contact Input Speed Control)
SPEED3 3rd Speed (Contact Input Speed Control)
Unit: r/min
Unit: r/min
Unit: r/min
Setting Range: 0 to Maximum Speed
Setting Range: 0 to Maximum Speed
Setting Range: 0 to Maximum Speed
Factory Setting: 100
Factory Setting: 200
Factory Setting: 300
0: OFF, 1: ON
3
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
For Speed/Torque Control and Position Control
Use these user constants to set motor speeds when the contact input speed control function is used (set bit 2 of memory switch Cn-02).
Speed selection input signals P-CL and N-CL selection signal P-CON motor to run at the preset speeds.
c) Set the soft start time (for speed/torque control only).
Cn-07
Cn-23
(1CN-46), and rotation direction
(1CN-41) enable the
SFSACC Soft Start Time (Acceleration)
SFSDEC Soft Start Time (Deceleration)
Unit:msSetting
Unit:msSetting
(1CN-45)
Range: 0 to 10000
Range: 0 to 10000
Contact input speed control (Memory switch Cn-02 bit 2 = 1)
Contact input
Factory Setting: 0
For Speed/Torque Control and Position Control
Factory Setting: 0
For Speed/Torque Control and Position Control
Servopack
Run the motor at internally set speed
Servomotor
87
Loading...