Yamaha Audio YDP2006 User Manual

PARAMETRIC EQUALIZER
OPERATING MANUAL MANUEL D’UTILISATION BEDIENUNGSHANDBUCH
­LR
R
L
CLIP
-6
0
-12
-18
-24
-30
-36
-42
+10
MEMORY
YDP2006
PARAMETRIC EQUALIZER
FGQ
1234
NOTCH
PEQ
123456
HPF LPF
STORE
MEMORY
RECALL
PEQ
NOTCH UTILITY
LR
BYPASS
POWER
ON
OFF
1.
FCC INFORMATION (U.S.A.)
IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!
This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product.
2. IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s supplied with this product MUST be used. Follow all installation instructions. Failure to follow instructions could void your FCC authorization to use this product in the USA.
3. NOTE: This product has been tested and found to comply with the requirements listed in FCC Regulations, Part 15 for Class “B” digital devices. Compliance with these requirements provides a reasonable level of assurance that your use of this product in a residential environment will not result in harmful interference with other electronic devices. This equipment generates/uses radio frequencies and, if not installed and used according to the instructions found in the users manual, may cause interference harmful to the operation of other electronic devices. Compliance with FCC regulations does not guarantee that interference will not occur in all installations. If this product is found to be the source of interference, which can be determined by turning the unit “OFF” and “ON”, please try to eliminate the problem by using one of the following measures:
Relocate either this product or the device that is being affected by the interference.
Utilize power outlets that are on different branch (circuit breaker or fuse) circuits or install AC line filter/s.
In the case of radio or TV interference, relocate/reorient the antenna. If the antenna lead-in is 300 ohm ribbon lead, change the lead-in to co-axial type cable.
If these corrective measures do not produce satisfactory results, please contact the local retailer authorized to distribute this type of product. If you can not locate the appropriate retailer, please contact Yamaha Corporation of America, Electronic Service Division, 6600 Orangethorpe Ave, Buena Park, CA 90620
*This applies only to products distributed by YAMAHA CORPORATION
OF AMERICA
CANADA
This digital apparatus does not exceed the “Class B” limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radio­électriques dépassant les limites applicables aux appareils numériques de la “Classe B” prescrites dans le Règlement sur le brouillage radioélectrique édicté par le Ministère Des Communications du Canada.
*This applies only to products distributed by YAMAHA CANADA MUSIC LTD.
IMPORTANT NOTICE FOR THE UNITED KINGDOM
Connecting the Plug and Cord WARNING: THIS APPARATUS MUST BE EARTHED
IMPORTANT: The wires in this mains lead are coloured in accor-
dance with the following code:
GREEN-AND-YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE
As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN or GREEN-AND-YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.
YDP2006
Contents
1 – Contents
Congratulations Precautions The front panel The rear panel Memory areas
How the memories are arranged in the YDP2006 Recalling an equalization setting Storing an equalization setting A note on software protection
Using the display
The [PEQ] and [NOTCH] keys
Display when in stereo mode ............................................................................................................ 7
Display when in mono mode ............................................................................................................. 8
The
[L/<] and [R/>] keys
Linking channels The PEQ, notch and HPF and LPF indicators
Utilities
................................................................................................................................................... 10
SYSTEM SETUP TITLE EDIT BULK DUMP Y-485 NETWORK Y-485 COMM. I/O PARAMETER COPY SOFTWARE PROTECT MIDI CONTROL DELAY DISPLAY
TUTORIAL
Finding a suitable memory area in which to store the setting Initializing the memory area Linking the L and R channels Making parametric equalizer settings Using the notch filters, and the HPF and LPF
I. Turning the filters on and off individually .................................................................................... 16
II. Editing the filters graphically ...................................................................................................... 16
III. Editing the filters numerically ....................................................................................................17
Setting up the input level, attenuation and delay
I. Input level and input attenuation .................................................................................................18
II. Delay .......................................................................................................................................... 18
Specifications MIDI Implementation Chart User programs Program change table Block diagram Dimensions
...................................................................................................................................... 2
.............................................................................................................................................. 3
....................................................................................................................................... 4
......................................................................................................................................... 5
......................................................................................................................................... 6
........................................................................... 6
....................................................................................................... 6
........................................................................................................... 6
........................................................................................................... 6
.................................................................................................................................... 7
................................................................................................................. 7
........................................................................................................................ 8
.................................................................................................................................. 9
................................................................................... 9
.................................................................................................................................. 10
.......................................................................................................................................... 10
...................................................................................................................................... 11
.............................................................................................................................. 11
............................................................................................................................ 12
........................................................................................................................... 12
....................................................................................................................... 13
................................................................................................................................13
................................................................................................................................13
............................................................................................................................................. 14
...................................................... 14
............................................................................................................ 14
............................................................................................................ 14
............................................................................................. 15
................................................................................. 16
.......................................................................... 18
........................................................................................................................................ 19
............................................................................................................. 65
...................................................................................................................................... 66
.......................................................................................................................... 67
....................................................................................................................................... 68
............................................................................................................................................ 69
English
YDP2006
2 – Congratulations
Congratulations
Your new YDP2006 Digital Parametric Equalizer uses the most advanced Yamaha digital signal processing to provide extremely precise, stable equalization.
As well as a stereo 6 band parametric equalizer, the YDP2006 Digital Parametric Equalizer has a high and low pass filter, and 4 notch filters which can be used to selectively “knock out” specific frequencies. When running in mono mode, the YDP2006 provides not 6, but 12 bands, and 8 notch filters. Furthermore, the unit can operate at either 6 or 12dB cut/boost.
If you are used to using conventional analog parametric equalizers with knobs you will find the YDP2006 very easy to use. Selecting “knobs” and “turning” them are simple operations performed with rotary encoders on the front panel. With a multi-function LCD screen, you can see at a glance exactly which “knob”, or notch filter you are moving. Or if you prefer, you can change to a purely numeric display for the parametric filter and notch filter param­eters.
One of the biggest advantages of Yamaha digital equalizers (apart from their stunning 20 bit sound) is the ability to store the equalizer settings you create for instant recall. The YDP2006 has the ability to store 40 different settings in this way, avoiding the need to completely reconfigure the knobs every time the unit has to be used for a different purpose, or in another environment.
In order to satisfy the most demanding needs of music professionals, the YDP2006 is able to be controlled not only by MIDI, but also by the new standard Y-485 interface. This allows for the fastest possible system configuration, without having to use up an extra MIDI channel to send program changes.
We urge you to read this manual carefully before using this unit, in order to fully appreciate, and be able to take advantage of, the many advanced features it offers.
YDP2006
Downloaded from:
Precautions
Avoid excessive heat, humidity, dust and vibration
Keep the unit away from locations where it is likely to be exposed to high temperatures or humidity - such as near radiators, stoves, etc. Also avoid locations which are subject to excessive dirt accumulation or vibration which could cause mechanical damage.
Avoid physical shocks
Strong physical shocks to the unit can cause damage. Handle it with care.
Do not open the unit, or attempt repairs or modifications yourself
This product contains no user-serviceable parts. Refer all maintenance to qualified Yamaha service personnel. Opening the unit and/or tampering with the internal circuitry will void the warranty.
Make sure power is off before making or removing connections
Always turn the power OFF prior to connecting or disconnecting cables. This is important to prevent damage to the unit itself as well as other connected equipment.
3 – Precautions
Handle cables carefully
Always plug and unplug cables - including the AC cord - by gripping the connector, not the cord.
Clean with a soft dry cloth
Never use solvents such as benzine or thinner to clean the unit. Wipe clean with a soft, dry cloth.
Always use the correct power source
Make sure that the power source voltage specified on the rear panel matches your local AC mains supply:
U.S. & Canadian Model: 120V AC, 60Hz General Model: 230V AC, 50Hz UK and Australian Model: 240V AC, 50Hz
Backup battery
The unit contains a long-life lithium battery which maintains the contents of the buffer and user memory locations even when the unit is off. With normal use, the battery should last approximately 5 years. If the battery voltage falls below a certain level, a “***WARNING*** LOW BATTERY” message will appear on the screen when the power is turned on. If this occurs, have the battery replaced by at a qualified Yamaha service center. Do not attempt to replace the battery yourself!
YDP2006
4 – The front panel
The front panel
RECALL
8
9
PEQ
NOTCH UTILITY
LR
AB
:
BYPASS
B
1
INPUT LEVEL
­LR
2
3
R
L
CLIP
-6
0
-12
-18
-24
-30
-36
-42
+10
MEMORY
45
PARAMETRIC EQUALIZER
FGQ
1234
NOTCH
PEQ
123456
HPF LPF
STORE
7
MEMORY
6
From left to right, the controls on the front panel are:
1
INPUT LEVEL – two concentric rotary controls (inner control is left channel) to adjust the
level of the signal fed into the YDP2006.
2
Level meters – L and R – These meters come after the A-D convertors in the signal chain.
A “CLIP” indication therefore indicates digital distortion, and the input levels should be adjusted so that the “CLIP” indicators never light.
3
Memory – this 2-digit LED indicator shows the current memory area.
Screen – this 56 x 128 pixel display gives a graphic representation of the current equal-
4
ization settings. It is also used to display other settings which you can edit using the front panel controls.
5
Rotary encoders – the F , G and Q controls are used primarily for setting the Frequency,
Gain and Q of equalization bands. When editing utility settings, they may also be used for editing data.
POWER
ON
OFF
6
PEQ/NOTCH selectors and indicators – When the PEQ key
8
is lit, the selectors are used to select a band from PEQ 1–6 (or either MONO.L 1–6, or MONO.R 1-6 when in mono mode).
When the NOTCH key
9
is lit, they are used to select a band among notches 1–4, and the HPF and LPF filters or, when in mono mode, MONO.L (1–4 and HPF and LPF) or MONO.R (1-4). The indicators show the status of the various bands/filters, and light when the corre­sponding band/filter is on.
7
MEMORY keys – the [STORE] , [RECALL] , [^] and [%] keys are used to read and write settings
stored in the 40 memory areas.
8
PEQ key – pressing this key will show the parameters for the parametric equalizer (in either graphic or numerical form), and enable the PEQ selectors. The indicators will show the on/off status of the parametric bands.
9 NOTCH key – pressing this key will show the parameters for the notch filters (in either
graphic or numerical form), and enable the NOTCH selectors and indicators.
0 UTILITY key – pressing this key will cycle through a range of screens, allowing you to set
up various system parameters for the unit.
A [L/<] and [R/>] keys – you can make equalization settings for the left and right channels
independently. These keys allow you to select which channel you are editing. By press­ing one of these keys, holding it down, and then pressing the other, you can edit the parameters of both channels simultaneously.
YDP2006
Downloaded from:
B BYPASS key – when pressed, the signal fed into the unit will bypass the internal circuitry,
and will be re-output “as is”.
The rear panel
5 – The rear panel
1
Y-485 MIDI
THRU
2 4
OUT
IN
3
OUTPUT
RL
+4dB
-20dB +4dB-20dB
INPUT
RL
5
1 Y-485 – these bi-directional connectors are used to connect the unit on a network “chain”
using the Y-485 control protocol. They do not carry audio signals. When making a Y-485 connection, either terminal may be used for IN or OUT.
Please use digital audio cable (impedance 90~120 Ω shield type equilibrium transmis-
sion cable) for connection with periphery equipment.
Using general analog audio cable (impedance 40~50 shield type equilibrium transmis-
sion cable) could cause trouble such as signal reflection due to mismatching impedance and transmission waveform turbulence. Waveform turbulence is especially noticeable with long cables, and with multi cable longer than 10 meters. If the length of the cable is longer than 100 meters, it is recommended that it should be terminated with a resistor matching the impedance of the cable (connect a resistor of
approx. 100 between Pin 2 and Pin 3).
2 MIDI IN, OUT and THRU – These terminals are used for MIDI control of the unit. IN is
used to receive MIDI data, THRU passes along information received at the IN terminal, and OUT transmits data originated by the unit.
3 OUTPUT (L, R) – these balanced XLR-type connectors output the signal from the unit.
4 INPUT (L, R) – these balanced XLR-type connectors are used to input signals to the unit.
5 Level switches – both the input and output connectors may be set to nominal levels of
+4dB or -20dB. When connecting other equipment, refer to the specifications of the other units to match the signal levels correctly.
YDP2006
6 – Memory areas
Memory areas
How the memories are arranged in the YDP2006
The unit contains 40 memory areas which contain equalization settings, all of which are user-programmable. This allows you to set up and store frequently-used equalization set­tings which you can recall at any time. These settings can be stored to a mass-storage device (MIDI data file system or personal computer system) either through the MIDI interface, or the Y-485 connectors (see the section on “Utilities” for full details of this).
Recalling an equalization setting
Use the MEMORY [^] and [%] keys to display the name of the setting you want to recall. The name (set in UTILITY mode) is shown in the middle of the display, and the memory number flashes on the LED display.
Press the [RECALL] key. If you had not made any changes to the previous setting, the new setting will be displayed
immediately. If you had made changes to the previous setting without storing them, the unit will flash
“RECALL OK?” in the center of the screen. If you really want to recall this setting, press the [RECALL] key again (while this message is flashing, you can use the MEMORY [^] and [%] keys to select another setting to be recalled). If you press the [RECALL] key, the number in the LED will stop flashing, and the screen will show the equalization curve for this setting. If you have made a mistake in selecting the setting or pressing the [RECALL] key in the first place, and do not want to recall the setting, press any key except the [RECALL] key.
Remember that the equalization curve shown will be for either the left or the right channel, depending on whether the [L/<] or [R/>] key is lit.
Storing an equalization setting
When you have edited a setting, you use the MEMORY [^] and [%] keys to select a memory area where you want to store the setting (if the memory area you are editing is the area where you want to store the setting, you do not need to press the [^] and [%] keys). As you step through the memory areas, the name of each one will be displayed in the center of the screen.
When you have selected the area, press the [STORE] key to write these settings into memory. The unit will flash “STORE OK?” in the center of the screen. Press the [STORE] key again to confirm the store, or any other key to cancel the store.
A note on software protection
You can protect the settings against accidental key-presses, etc., by using the UTILITY soft­ware protection (see “SOFTWARE PROTECT” on page 3). If protection is set to ON, then any attempt to store or recall settings using the methods described above will result in the
message “ERR ** NOW PROTECT” being shown on the screen. The 2-digit LED will start to
flash if you attempt to recall, store or modify a setting with protection on, as an additional
warning. If you get the “ERR ** NOW PROTECT” message when trying to perform any operations with protection on, press any key to stop the LED flashing. “ERR ** NOW PRO-
TECT” will disappear from the screen.
YDP2006
Downloaded from:
Using the display
The
[PEQ]
and
Using the large LCD screen, your YDP2006 has several different ways of displaying settings, and being able to edit them. These different modes are accessed with the [PEQ] and [NOTCH] keys. Pressing the [PEQ] key will take you through the equalization displays, and pressing the [NOTCH] key will take you through the notch filter, and LPF and HPF filter displays.
NOTE
The displays differ in mono and stereo mode. To set the mono/stereo mode, refer to the “Utilities” section, later in the manual.
Display when in stereo mode:
PEQ displays:
[NOTCH]
keys
7 – Using the display
PEQ
PEQ PEQ
PEQ PEQ
Notch displays:
NOTCH
PEQ
Graphical display of all active equalizer bands.
Numerical display of all equalizer bands.
Delay and attenuation parameters.
NOTCH
Graphical display of all active notch, HPF and LPF filters.
NOTCH NOTCH
Numerical display of the notch, HPF and LPF parameters.
YDP2006
Loading...
+ 19 hidden pages