Yamaha Audio YDP2006 User Manual

PARAMETRIC EQUALIZER
OPERATING MANUAL MANUEL D’UTILISATION BEDIENUNGSHANDBUCH
­LR
R
L
CLIP
-6
0
-12
-18
-24
-30
-36
-42
+10
MEMORY
YDP2006
PARAMETRIC EQUALIZER
FGQ
1234
NOTCH
PEQ
123456
HPF LPF
STORE
MEMORY
RECALL
PEQ
NOTCH UTILITY
LR
BYPASS
POWER
ON
OFF
1.
FCC INFORMATION (U.S.A.)
IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT!
This product, when installed as indicated in the instructions contained in this manual, meets FCC requirements. Modifications not expressly approved by Yamaha may void your authority, granted by the FCC, to use the product.
2. IMPORTANT: When connecting this product to accessories and/or another product use only high quality shielded cables. Cable/s supplied with this product MUST be used. Follow all installation instructions. Failure to follow instructions could void your FCC authorization to use this product in the USA.
3. NOTE: This product has been tested and found to comply with the requirements listed in FCC Regulations, Part 15 for Class “B” digital devices. Compliance with these requirements provides a reasonable level of assurance that your use of this product in a residential environment will not result in harmful interference with other electronic devices. This equipment generates/uses radio frequencies and, if not installed and used according to the instructions found in the users manual, may cause interference harmful to the operation of other electronic devices. Compliance with FCC regulations does not guarantee that interference will not occur in all installations. If this product is found to be the source of interference, which can be determined by turning the unit “OFF” and “ON”, please try to eliminate the problem by using one of the following measures:
Relocate either this product or the device that is being affected by the interference.
Utilize power outlets that are on different branch (circuit breaker or fuse) circuits or install AC line filter/s.
In the case of radio or TV interference, relocate/reorient the antenna. If the antenna lead-in is 300 ohm ribbon lead, change the lead-in to co-axial type cable.
If these corrective measures do not produce satisfactory results, please contact the local retailer authorized to distribute this type of product. If you can not locate the appropriate retailer, please contact Yamaha Corporation of America, Electronic Service Division, 6600 Orangethorpe Ave, Buena Park, CA 90620
*This applies only to products distributed by YAMAHA CORPORATION
OF AMERICA
CANADA
This digital apparatus does not exceed the “Class B” limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radio­électriques dépassant les limites applicables aux appareils numériques de la “Classe B” prescrites dans le Règlement sur le brouillage radioélectrique édicté par le Ministère Des Communications du Canada.
*This applies only to products distributed by YAMAHA CANADA MUSIC LTD.
IMPORTANT NOTICE FOR THE UNITED KINGDOM
Connecting the Plug and Cord WARNING: THIS APPARATUS MUST BE EARTHED
IMPORTANT: The wires in this mains lead are coloured in accor-
dance with the following code:
GREEN-AND-YELLOW : EARTH BLUE : NEUTRAL BROWN : LIVE
As the colours of the wires in the mains lead of this apparatus may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:
The wire which is coloured GREEN-AND-YELLOW must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or coloured GREEN or GREEN-AND-YELLOW.
The wire which is coloured BLUE must be connected to the terminal which is marked with the letter N or coloured BLACK.
The wire which is coloured BROWN must be connected to the terminal which is marked with the letter L or coloured RED.
YDP2006
Contents
1 – Contents
Congratulations Precautions The front panel The rear panel Memory areas
How the memories are arranged in the YDP2006 Recalling an equalization setting Storing an equalization setting A note on software protection
Using the display
The [PEQ] and [NOTCH] keys
Display when in stereo mode ............................................................................................................ 7
Display when in mono mode ............................................................................................................. 8
The
[L/<] and [R/>] keys
Linking channels The PEQ, notch and HPF and LPF indicators
Utilities
................................................................................................................................................... 10
SYSTEM SETUP TITLE EDIT BULK DUMP Y-485 NETWORK Y-485 COMM. I/O PARAMETER COPY SOFTWARE PROTECT MIDI CONTROL DELAY DISPLAY
TUTORIAL
Finding a suitable memory area in which to store the setting Initializing the memory area Linking the L and R channels Making parametric equalizer settings Using the notch filters, and the HPF and LPF
I. Turning the filters on and off individually .................................................................................... 16
II. Editing the filters graphically ...................................................................................................... 16
III. Editing the filters numerically ....................................................................................................17
Setting up the input level, attenuation and delay
I. Input level and input attenuation .................................................................................................18
II. Delay .......................................................................................................................................... 18
Specifications MIDI Implementation Chart User programs Program change table Block diagram Dimensions
...................................................................................................................................... 2
.............................................................................................................................................. 3
....................................................................................................................................... 4
......................................................................................................................................... 5
......................................................................................................................................... 6
........................................................................... 6
....................................................................................................... 6
........................................................................................................... 6
........................................................................................................... 6
.................................................................................................................................... 7
................................................................................................................. 7
........................................................................................................................ 8
.................................................................................................................................. 9
................................................................................... 9
.................................................................................................................................. 10
.......................................................................................................................................... 10
...................................................................................................................................... 11
.............................................................................................................................. 11
............................................................................................................................ 12
........................................................................................................................... 12
....................................................................................................................... 13
................................................................................................................................13
................................................................................................................................13
............................................................................................................................................. 14
...................................................... 14
............................................................................................................ 14
............................................................................................................ 14
............................................................................................. 15
................................................................................. 16
.......................................................................... 18
........................................................................................................................................ 19
............................................................................................................. 65
...................................................................................................................................... 66
.......................................................................................................................... 67
....................................................................................................................................... 68
............................................................................................................................................ 69
English
YDP2006
2 – Congratulations
Congratulations
Your new YDP2006 Digital Parametric Equalizer uses the most advanced Yamaha digital signal processing to provide extremely precise, stable equalization.
As well as a stereo 6 band parametric equalizer, the YDP2006 Digital Parametric Equalizer has a high and low pass filter, and 4 notch filters which can be used to selectively “knock out” specific frequencies. When running in mono mode, the YDP2006 provides not 6, but 12 bands, and 8 notch filters. Furthermore, the unit can operate at either 6 or 12dB cut/boost.
If you are used to using conventional analog parametric equalizers with knobs you will find the YDP2006 very easy to use. Selecting “knobs” and “turning” them are simple operations performed with rotary encoders on the front panel. With a multi-function LCD screen, you can see at a glance exactly which “knob”, or notch filter you are moving. Or if you prefer, you can change to a purely numeric display for the parametric filter and notch filter param­eters.
One of the biggest advantages of Yamaha digital equalizers (apart from their stunning 20 bit sound) is the ability to store the equalizer settings you create for instant recall. The YDP2006 has the ability to store 40 different settings in this way, avoiding the need to completely reconfigure the knobs every time the unit has to be used for a different purpose, or in another environment.
In order to satisfy the most demanding needs of music professionals, the YDP2006 is able to be controlled not only by MIDI, but also by the new standard Y-485 interface. This allows for the fastest possible system configuration, without having to use up an extra MIDI channel to send program changes.
We urge you to read this manual carefully before using this unit, in order to fully appreciate, and be able to take advantage of, the many advanced features it offers.
YDP2006
Downloaded from:
Precautions
Avoid excessive heat, humidity, dust and vibration
Keep the unit away from locations where it is likely to be exposed to high temperatures or humidity - such as near radiators, stoves, etc. Also avoid locations which are subject to excessive dirt accumulation or vibration which could cause mechanical damage.
Avoid physical shocks
Strong physical shocks to the unit can cause damage. Handle it with care.
Do not open the unit, or attempt repairs or modifications yourself
This product contains no user-serviceable parts. Refer all maintenance to qualified Yamaha service personnel. Opening the unit and/or tampering with the internal circuitry will void the warranty.
Make sure power is off before making or removing connections
Always turn the power OFF prior to connecting or disconnecting cables. This is important to prevent damage to the unit itself as well as other connected equipment.
3 – Precautions
Handle cables carefully
Always plug and unplug cables - including the AC cord - by gripping the connector, not the cord.
Clean with a soft dry cloth
Never use solvents such as benzine or thinner to clean the unit. Wipe clean with a soft, dry cloth.
Always use the correct power source
Make sure that the power source voltage specified on the rear panel matches your local AC mains supply:
U.S. & Canadian Model: 120V AC, 60Hz General Model: 230V AC, 50Hz UK and Australian Model: 240V AC, 50Hz
Backup battery
The unit contains a long-life lithium battery which maintains the contents of the buffer and user memory locations even when the unit is off. With normal use, the battery should last approximately 5 years. If the battery voltage falls below a certain level, a “***WARNING*** LOW BATTERY” message will appear on the screen when the power is turned on. If this occurs, have the battery replaced by at a qualified Yamaha service center. Do not attempt to replace the battery yourself!
YDP2006
4 – The front panel
The front panel
RECALL
8
9
PEQ
NOTCH UTILITY
LR
AB
:
BYPASS
B
1
INPUT LEVEL
­LR
2
3
R
L
CLIP
-6
0
-12
-18
-24
-30
-36
-42
+10
MEMORY
45
PARAMETRIC EQUALIZER
FGQ
1234
NOTCH
PEQ
123456
HPF LPF
STORE
7
MEMORY
6
From left to right, the controls on the front panel are:
1
INPUT LEVEL – two concentric rotary controls (inner control is left channel) to adjust the
level of the signal fed into the YDP2006.
2
Level meters – L and R – These meters come after the A-D convertors in the signal chain.
A “CLIP” indication therefore indicates digital distortion, and the input levels should be adjusted so that the “CLIP” indicators never light.
3
Memory – this 2-digit LED indicator shows the current memory area.
Screen – this 56 x 128 pixel display gives a graphic representation of the current equal-
4
ization settings. It is also used to display other settings which you can edit using the front panel controls.
5
Rotary encoders – the F , G and Q controls are used primarily for setting the Frequency,
Gain and Q of equalization bands. When editing utility settings, they may also be used for editing data.
POWER
ON
OFF
6
PEQ/NOTCH selectors and indicators – When the PEQ key
8
is lit, the selectors are used to select a band from PEQ 1–6 (or either MONO.L 1–6, or MONO.R 1-6 when in mono mode).
When the NOTCH key
9
is lit, they are used to select a band among notches 1–4, and the HPF and LPF filters or, when in mono mode, MONO.L (1–4 and HPF and LPF) or MONO.R (1-4). The indicators show the status of the various bands/filters, and light when the corre­sponding band/filter is on.
7
MEMORY keys – the [STORE] , [RECALL] , [^] and [%] keys are used to read and write settings
stored in the 40 memory areas.
8
PEQ key – pressing this key will show the parameters for the parametric equalizer (in either graphic or numerical form), and enable the PEQ selectors. The indicators will show the on/off status of the parametric bands.
9 NOTCH key – pressing this key will show the parameters for the notch filters (in either
graphic or numerical form), and enable the NOTCH selectors and indicators.
0 UTILITY key – pressing this key will cycle through a range of screens, allowing you to set
up various system parameters for the unit.
A [L/<] and [R/>] keys – you can make equalization settings for the left and right channels
independently. These keys allow you to select which channel you are editing. By press­ing one of these keys, holding it down, and then pressing the other, you can edit the parameters of both channels simultaneously.
YDP2006
Downloaded from:
B BYPASS key – when pressed, the signal fed into the unit will bypass the internal circuitry,
and will be re-output “as is”.
The rear panel
5 – The rear panel
1
Y-485 MIDI
THRU
2 4
OUT
IN
3
OUTPUT
RL
+4dB
-20dB +4dB-20dB
INPUT
RL
5
1 Y-485 – these bi-directional connectors are used to connect the unit on a network “chain”
using the Y-485 control protocol. They do not carry audio signals. When making a Y-485 connection, either terminal may be used for IN or OUT.
Please use digital audio cable (impedance 90~120 Ω shield type equilibrium transmis-
sion cable) for connection with periphery equipment.
Using general analog audio cable (impedance 40~50 shield type equilibrium transmis-
sion cable) could cause trouble such as signal reflection due to mismatching impedance and transmission waveform turbulence. Waveform turbulence is especially noticeable with long cables, and with multi cable longer than 10 meters. If the length of the cable is longer than 100 meters, it is recommended that it should be terminated with a resistor matching the impedance of the cable (connect a resistor of
approx. 100 between Pin 2 and Pin 3).
2 MIDI IN, OUT and THRU – These terminals are used for MIDI control of the unit. IN is
used to receive MIDI data, THRU passes along information received at the IN terminal, and OUT transmits data originated by the unit.
3 OUTPUT (L, R) – these balanced XLR-type connectors output the signal from the unit.
4 INPUT (L, R) – these balanced XLR-type connectors are used to input signals to the unit.
5 Level switches – both the input and output connectors may be set to nominal levels of
+4dB or -20dB. When connecting other equipment, refer to the specifications of the other units to match the signal levels correctly.
YDP2006
6 – Memory areas
Memory areas
How the memories are arranged in the YDP2006
The unit contains 40 memory areas which contain equalization settings, all of which are user-programmable. This allows you to set up and store frequently-used equalization set­tings which you can recall at any time. These settings can be stored to a mass-storage device (MIDI data file system or personal computer system) either through the MIDI interface, or the Y-485 connectors (see the section on “Utilities” for full details of this).
Recalling an equalization setting
Use the MEMORY [^] and [%] keys to display the name of the setting you want to recall. The name (set in UTILITY mode) is shown in the middle of the display, and the memory number flashes on the LED display.
Press the [RECALL] key. If you had not made any changes to the previous setting, the new setting will be displayed
immediately. If you had made changes to the previous setting without storing them, the unit will flash
“RECALL OK?” in the center of the screen. If you really want to recall this setting, press the [RECALL] key again (while this message is flashing, you can use the MEMORY [^] and [%] keys to select another setting to be recalled). If you press the [RECALL] key, the number in the LED will stop flashing, and the screen will show the equalization curve for this setting. If you have made a mistake in selecting the setting or pressing the [RECALL] key in the first place, and do not want to recall the setting, press any key except the [RECALL] key.
Remember that the equalization curve shown will be for either the left or the right channel, depending on whether the [L/<] or [R/>] key is lit.
Storing an equalization setting
When you have edited a setting, you use the MEMORY [^] and [%] keys to select a memory area where you want to store the setting (if the memory area you are editing is the area where you want to store the setting, you do not need to press the [^] and [%] keys). As you step through the memory areas, the name of each one will be displayed in the center of the screen.
When you have selected the area, press the [STORE] key to write these settings into memory. The unit will flash “STORE OK?” in the center of the screen. Press the [STORE] key again to confirm the store, or any other key to cancel the store.
A note on software protection
You can protect the settings against accidental key-presses, etc., by using the UTILITY soft­ware protection (see “SOFTWARE PROTECT” on page 3). If protection is set to ON, then any attempt to store or recall settings using the methods described above will result in the
message “ERR ** NOW PROTECT” being shown on the screen. The 2-digit LED will start to
flash if you attempt to recall, store or modify a setting with protection on, as an additional
warning. If you get the “ERR ** NOW PROTECT” message when trying to perform any operations with protection on, press any key to stop the LED flashing. “ERR ** NOW PRO-
TECT” will disappear from the screen.
YDP2006
Downloaded from:
Using the display
The
[PEQ]
and
Using the large LCD screen, your YDP2006 has several different ways of displaying settings, and being able to edit them. These different modes are accessed with the [PEQ] and [NOTCH] keys. Pressing the [PEQ] key will take you through the equalization displays, and pressing the [NOTCH] key will take you through the notch filter, and LPF and HPF filter displays.
NOTE
The displays differ in mono and stereo mode. To set the mono/stereo mode, refer to the “Utilities” section, later in the manual.
Display when in stereo mode:
PEQ displays:
[NOTCH]
keys
7 – Using the display
PEQ
PEQ PEQ
PEQ PEQ
Notch displays:
NOTCH
PEQ
Graphical display of all active equalizer bands.
Numerical display of all equalizer bands.
Delay and attenuation parameters.
NOTCH
Graphical display of all active notch, HPF and LPF filters.
NOTCH NOTCH
Numerical display of the notch, HPF and LPF parameters.
YDP2006
8 – Using the display – The
Display when in mono mode:
PEQ displays:
[[[[LLLL////<<<<]]
]]
and
[[[[RRRR////>>>>]]
]]
keys
PEQ
PEQ
PEQ
Notch displays:
NOTCH
NOTCH
Mono
PEQ
Graphical display of all active equalizer bands (MONO.L 1-6 on one screen and MONO.R 1-6 on the other).
PEQ
Numerical display of all equalization bands (MONO.L 1-6 on one screen and MONO.R 1-6 on the other).
PEQ
Delay and attenuation parameters.
NOTCH
Graphical display of all active notch, HPF and LPF filters (filters MONO.L 1-4, HPF and LPF on one screen, and filters MONO.R 1-4 on the other).
NOTCH
The
[L/<]
YDP2006
Numerical display of the notch, HPF and LPF parameters.
and
[R/>]
keys
When in stereo mode, each of the above displays can show either the settings for the left channel, or the settings for the right channel. To select which channel will be displayed, press the [L/<] or [R/>] key. The LED on the corresponding key will light up, the display will change to show the new channel, and either R or L will appear in the top left of the screen.
In mono mode, if the unit is in PEQ mode, the [L/<] and [R/>] keys toggle between equalization bands MONO.L 1-6 and MONO.R 1-6. If the unit is in notch mode, the [L/<] and [R/>] keys toggle between notches 1-4, HPF, LPF (MONO.L), and MONO.R notches 1-4, as shown above.
Linking channels
In order to change both the L and R channels at the same time, the L and R channels must be linked. When the channels are linked, making any changes to one channel will also affect the other. Existing parameters from one channel will not be copied to the other channel, unless they are altered while the channels are linked.
To link the channels, press one of the two channel keys (either [L/<] or [R/>]), and while hold­ing it down, press the other one. Because the screen can only show one channel at a time, only the settings of the first channel you pressed will be displayed, and the LED on that key will light. The settings of the other channel will not be displayed, and its LED will blink.
The PEQ, notch and HPF and LPF indicators
9 – Using the display – Linking channels
NOTCH
PEQ
21 3 4 HPF LPF
432156
The small round LEDs above the PEQ and notch selectors indicate whether or not the corre­sponding PEQ band, or notch filter is active (turned on). When the LED on the PEQ key is on, the row of indicators refers to the PEQ bands. When the LED on the NOTCH key is on, the row of indicators refers to the notch, and LPF and HPF filters.
To turn a specific notch, filter or PEQ band on or off, it must first be selected for editing. If the parameters for the desired band are not displayed at the top of the screen (in graphical display screens), or the name of the notch highlighted on the left of the screen (in the text display modes), you must press the selector twice—once to select which notch, filter or PEQ band to change (this also selects it for editing), and once to toggle it between on and off. If the notch, filter or PEQ band is already selected for editing, simply pressing the selector once will do the toggling.
Put more simply, if you wish to toggle a notch, filter on/off that is already selected, just press the selector once. If it’s not selected, press the selector twice.
YDP2006
10 – Utilities
Utilities
The [UTILITY] key allows you to set up various system parameters for the unit. Repeated presses of the key will cycle you through the following modes. You can also use the [%] and
[%] keys to cycle through these parameters (but this will not return to the equalization set-
ting display):
Equalization
setting display
NOTE
You can also exit the UTILITY mode by pressing either the [PEQ] or [NOTCH] key.
The [UTILITY] key will be lit for all these displays
SYSTEM SET UP BULK DUMPTITLE EDIT Y-485 NETWORK
Y-485 COMM. I/O
SOFTWARE PROTECTDELAY DISPLAY PARAMETER COPYMIDI CONTROL
SYSTEM SETUP
If you are in stereo mode, you will only have one parameter here: EMPHASIS. If you are in mono mode, you will also have the option (INP. MODE) of whether the signal is taken from the left or right input.
The emphasis function is a type of noise reduction and can effectively be used to reduce the high-frequency noise produced during A/D conversion and D/A conversion. It causes some deterioration of the dynamic range in the high-frequency range, however.
Because this equipment uses a 20-bit AD/DA converter, a sufficient dynamic range is assured even when the emphasis function is turned off. Setting it to OFF will work best for most material most of the time.
TITLE EDIT
Each equalization setting may have a name. This may be useful in a mobile PA setup which is often used at the same venues at different times (a setting named “UNIV. STADIUM” is easier to remember again than program 23). Names set using this function are displayed on the screen whenever you step through the memory areas using the [%] or [^] keys.
Emphasis: Use the F encoder to turn emphasis on and off (this trips an internal relay, so you will hear a “click” as this is switched).
Input mode: Use the G encoder (if you’re in mono mode) to set the input mode to either “L-MONO” (the signal is taken from the left channel input) or “R-MONO” (the sig­nal is taken from the right input). This option is only avail­able in mono mode.
Use the F encoder to select a character (0-9, A-Z, a-z + punctuation) and the [L/<] and [R/>] keys as cursor keys to determine which character will be edited. Use the [STORE] key as an easy way to enter a space.
YDP2006
BULK DUMP
NOTE
You can dump this data over MIDI to a MIDI data filer device (including a personal com­puter), or over the Y-485 network to a computer connected through the YAMAHA IFU485 interface.
There is no need to set the unit into any special receive mode to receive bulk dump data from an external device.
11 – Utilities – BULK DUMP
Three parameters are available here: Use the F encoder to select whether bulk dump operations
will take place through the MIDI or Y-485 connections. Use the G encoder to select what kind of data will be
dumped. You can choose between: ALL DATA (all memory areas will be dumped), SYSTEM (the parameters you set up in the UTILITY menus will be dumped), MEMORY (a single memory area, or all memory areas will be dumped), and BANK (the Program Change tables).
If you have selected MEMORY with the G encoder, use the Q encoder to select the memory area that you want to dump (1 through 40 or ALL).
If you have selected BANK with the G encoder, use the Q encoder to select the Program Change bank you want to dump (A through D or ALL).
Y-485 NETWORK
The Y-485 network is more complex (in terms of software addressing) than the MIDI system. Each device on a network belongs to a group and has a device number within that group.
To control this unit and other Y-485 units from a computer, you will require an IFU485 hard­ware interface, and computer software (QS-1) to control it. QS-1 software is available for both Macintosh and IBM-compatible computers. Contact Yamaha or your local Yamaha dis­tributor for further details.
Use the [L/<] and [R/>] keys to decide whether you are edit­ing the REMOTE or LOCAL settings. The LOCAL settings, of course, refer to this unit, and the REMOTE settings refer to a unit to which you will be sending data.
The F encoder allows you to set up a group number between 1 and 7. The Y-485 protocol allows messages to be sent to groups of units. If you are editing the REMOTE set­tings, you can also set this to a “*”. This is a “don’t care” value – the remote device address is irrelevant, and mes­sages will be sent to all groups.
The G encoder allows you to set a device number inside the group between 1 and 31. If you are editing REMOTE settings, you can also set this to a “*”. This is a “don’t care” value – the remote device address is irrelevant, and mes­sages will be sent to all devices.
The Q encoder allows you to set the data transfer rate for the LOCAL settings only. This should usually be set to 9600 (even though a value of 38400 may be set).
YDP2006
12 – Utilities – Y-485 COMM. I/O
Y-485 COMM. I/O
NOTE
These parameters are entirely independent of any data received at the MIDI ports.
PARAMETER COPY
This allows you to initialize new equalization settings from a “template” setting and to copy channel settings. The “template” settings allow you to set the mono/stereo mode, and the 6dB/12dB boost mode.
Whatever data you have chosen to copy (“template” or channel data) press the [STORE] key to start the copying process. If you have not set the software protection on, the message “** EXECUTING” will appear briefly on screen as the data is copied. If software protection is on, nothing will appear on screen, and no data will be copied when you press the [STORE] key.
Only one parameter is available here: the data which will be recognized by the unit over the Y-485 network. There are three values, selectable with the F encoder: OFF, PGM CHANGE and ALL. When OFF, no Y-485 messages will be recognized by the unit, when PGM CHANGE, only Pro­gram Change messages will be recognized by the unit, and when ALL, any data coming over the Y-485 interface will be recognized.
Use the F encoder to decide what setting you will use as the default, and where you will copy it to. There are four “template” settings available:
STEREO 12 is a stereo 6-band parametric EQ with 4 notch filters (plus HPF and LPF) and gain for each band of
±12dB.
STEREO 6 is a stereo 6-band parametric EQ with 4 notch
filters (plus HPF and LPF) and gain for each band of ±6dB.
MONO 12 is a mono 12-band parametric EQ with 8 notch filters (plus HPF and LPF) and gain for each band of
±12dB.
MONO 6 is a mono 12-band parametric EQ with 8 notch
filters (plus HPF and LPF) and gain for each band of ±6dB. Select the “template” you want to use using the F encoder.
The “template” will be copied to the edit area.
After the “template” settings, if the current setting is in ste­reo mode (STEREO 6 or STEREO 12), turning the F encoder will bring up two more options: from L-DATA to R-DATA and from R-DATA to L-DATA. This allows you to copy from one channel to another. If you are in mono mode, these options will of course not be available.
Using the G encoder, you can select what data is to be cop­ied between channels: ALL (self-explanatory), EQ (the parametric equalization settings), FILTER (the notch filter settings), or DELAY/ATT (the delay and attenuation set­tings).
YDP2006
SOFTWARE PROTECT
MIDI CONTROL
The unit will respond to MIDI Program Change messages sent from a master keyboard, sequencer or other device. It may be useful to remap program change settings so that a Pro­gram Change message of 2, for instance, selects memory area 40.
13 – Utilities – SOFTWARE PROTECT
Use the F encoder to turn memory protection on or off. When ON, the unit will not respond to Program Change messages received over MIDI or Y-485. You will not be able to store or copy any new or edited equalization settings if protection is ON. “ERR ** NOW PROTECT” will appear on the screen if you try to store data while protection is ON.
There are four “banks” of Program Change tables available – A through D. Use the [L/<] and [R/>] keys to select which bank will be edited. The bank displayed on this screen will remain the active bank after you have exited the UTILITY mode.
Use the F encoder to select the MIDI channel to which the bank will respond (OFF, 1 through 16 or OMNI).
Use the G encoder to select the Program Change number which will be recognized.
Use the Q encoder to select the memory area which will be recalled when the Program Change number set with the G encoder is received.
NOTE
The currently-selected Program Change bank is also applicable when a Y-485 Program Change is received.
DELAY DISPLAY
When using the unit in a sound reinforcement application, it is very often useful to delay one or both channels to com­pensate for phase differences caused by speaker place­ment. In this menu, use the F encoder to select the units in which this delay will be expressed: FEET, METERS or SECONDS. The distance units (FEET, METERS) allow you to enter delay times expressed in distance (select the appropriate one, depending on your familiarity with the metric system). The SECONDS option allows you to enter delay times directly in milliseconds.
YDP2006
14 – TUTORIAL
TUTORIAL
In this section we will go over the setting up of the YDP2006, from the parametric equalizer and the filters, to the delay and input attenuation. The information is presented as a tuto­rial—from it, you should be able to pick up the techniques necessary to make settings for any situation.
Finding a suitable memory area in which to store the setting
This may be an existing equalization setting which you wish to alter, or a completely new setting that you wish to create from scratch.
1 Ensure you are in one of the display screens (the utility
indicator is off). If you’re in utility mode, press the[PEQ] or [NOTCH] key.
2 To go to another memory setting, press the MEMORY
[^] or [%] keys until the name of the setting appears on
the screen, and its memory number flashes on the MEMORY display. Then press [RECALL] once. If you have edited the settings in the previous memory area, “RECALL OK?” will appear on the display as a warn­ing—press [RECALL] again to recall the new setting.
3 If you seem to be having problems with this, and “ERR
** NOW PROTECT” appears on the display, the mem­ory is protected. See the “Utilities” section.
Initializing the memory area
If you wish to start creating a setting from scratch, and there is an existing setting at the memory location you are working at, you can clear the existing setting using the PARAME­TER COPY function (see the “Utilities” section). This will also allow you to set whether the equalizer is in stereo mode (6 PEQ bands, and 4 notch filters per channel), or mono mode (12 PEQ bands, and 8 notch filters), and also whether the maximum cut/boost is 6dB or 12dB.
Settings in the PARAMETER COPY function
Display Mode
STEREO 12 STEREO 6 MONO 12 MONO 6
Linking the L and R channels
If you are working in stereo mode, you will probably frequently want to set up the L and R channels identically (at least for most of the settings), and then tweak the L and R channels separately. Linking the channels is the way to achieve this.
To link the channels, press one of the two channel keys (either [L/<] or [R/>]), and while hold­ing it down, press the other one. Only the settings of the first channel you pressed will be displayed, and the LED on that key will light.
Linking the channels does not automatically copy all parameters from one channel to the other. Only the parameters that you create or change while the channels are linked will be made to both channels.
Stereo Stereo Mono Mono
Maximum cut/boost
12dB
6dB
12dB
6dB
YDP2006
Making parametric equalizer settings
Here is where the user interface of the YDP2006 really makes parametric equalization easy. For the most part, you will never need to set any parameters numerically (unless you want to)—the resulting frequency response of the equalizer, and the notch filters can be displayed graphically on the screen.
1
Press the [PEQ] key until you see a screen similar to the one shown. The number of the currently selected band is shown below the channel indication in the top left corner of the display. The actual settings on your screen will probably be different to the ones shown here.
2 Select which equalization band you wish to edit. If the
number of this band is not shown below the channel indication (“Lch”, “Rch”, “MONO.L” or “MONO.R”) at the top left of the screen, press the corresponding PEQ selector to select it. The number of the band will appear below the channel indication. In mono mode, press either [L/<] or [R/>] to toggle between the display of bands MONO.L 1-6 and MONO.R 1-6.
Each band can only be set within a certain frequency range. These ranges are shown in the table below. As can be seen, the ranges overlap to a large degree, making them very flexible.
15 – TUTORIAL – Making parametric equalizer settings
Frequency ranges and Q for each equalizer band
Band
(Stereo mode)
L1, R1
L2 – L5
R2 – R5
L6, R6
Band
(Mono mode)
L1
L2 – L6
R1 – R5
R6
3 If you wish to see/hear the effects of the equalization
4 Turn the F rotary encoder, and notice how the dotted
Frequency
LSH, 0.5 – 10.0
20 Hz – 20.0 kHz
HSH, 0.5 – 10.0
band while it is being edited, make sure that the PEQ for the band is turned on (the appropriate PEQ indica­tor LED is lit). If it is not, press the corresponding PEQ selector. The current settings for the band will be shown in graphical form on the screen.
bar moves to the left and right. This is the frequency selector—any changes you will make with the gain rotary encoder affect only this frequency.
Q
0.5 – 10.0
YDP2006
16 – TUTORIAL – Using the notch filters, and the HPF and LPF
5 Once you have decided on the frequency for the equal-
izer band, turn the G rotary encoder to move the response curve up or down, and the Q rotary encoder to adjust the width of the band. The values of F, G and Q (frequency, gain and resonance) are also given numerically at the top of the screen. This process can be repeated for each of the bands, to create the desired set­tings.
NOTE
Remember that the settings for only one channel are displayed at a time, and you can toggle between them with the [L/<] and [R/>] keys. If you have linked the channels, the channel dis­played will be the one indicated at the top left of the screen (Lch or Rch).
6
Once the desired settings have been created, don’t for­get to store them in one of the memory areas, so you can use them again at a later time.
Using the notch filters, and the HPF and LPF
Besides the HPF and LPF, which are shelving high-pass and low-pass filters, respectively, the notch filters provide very selective gain cuts, with adjustable Q. One of their main uses is to filter out sounds that occur at specific frequencies, such as 50/60 Hz AC hum, or the high frequency noise induced by some fluorescent lighting, or lighting dimmers. Of course, to avoid affecting the original material any more than necessary, try to use the narrowest notch possible that will remove the offending signals.
Q is a measure of the resonance of the filter. Basically, the higher the Q, the narrower the notch. Except for setting the Q, the process for setting the notch filters and the HPF and LPF is exactly the same (the shelving HPF and LPF don’t have Q).
I. Turning the filters on and off individually
1 You must be in notch mode (the indicator on the
[NOTCH] key on). If you are not, then press the [NOTCH] key.
2 Use the [L/<] or [R/>] keys to select the appropriate left or
right channel display (in stereo mode), or to choose between notches MONO.L 1-4, HPF and LPF, and notches MONO.R 1-4 (in mono mode).
3 Then, ensure the notch or filter is selected for editing
(you may need to press the corresponding selector once to do this), then press the appropriate selector to toggle it on/off.
II. Editing the filters graphically
1 Press the [NOTCH] key until you see a screen similar to
the one here. If you are in mono mode, there are two screens like this (accessed with the [L/<] or [R/>] keys)— one for notches MONO.L 1-4, HPF and LPF, and one for notches MONO.R 1-4. The actual settings on your screen will probably be different to the ones shown here.
YDP2006
17 – TUTORIAL – Using the notch filters, and the HPF and LPF
2 To select a filter for editing (if it’s not already selected),
press one of the notch or filter selectors. The indication in the top left corner below the “Lch”, “Rch” or “MONO” indication shows the filter that is currently selected for editing. It will either show NOT1, 2, 3 or 4, HPF or LPF.
NOTE
If you wish to see and hear the effects of the filter while you are editing it, make sure the indicator above the filter selector is on. If not, press the selector.
3
Use the F rotary encoder to move the filter up or down the frequency band.
4 For the notch filters, use the Q rotary encoder to alter
the Q of the notch. As you adjust the filter parameters, the F (and Q if you’re not editing the HPF or LPF) will be shown numerically at the top of the screen. If the fil­ter is turned on (the appropriate indicator is lit), the screen will show the frequency response of the filter set­tings. Notice the extra width of the notch on the left, with Q of 0.5.
III. Editing the filters numerically
1 Press the [NOTCH] key until you see a screen similar to
the one shown. The screen shown is the one displayed in stereo mode. If you are in mono mode, there are two screens like this (accessed with the [L/<] or [R/>] keys)— one for notches MONO.L 1-4, HPF and LPF, and one for notches MONO.R 1-4. The actual settings on your screen will probably be different to the ones shown here.
2 To select a filter for editing (if it’s not already selected),
press one of the notch or filter selectors. The corre­sponding “NOT”, “HPF” or “LPF” indication on the left side of the screen will become highlighted, and a cursor will appear beneath the parameters for the currently selected filter (either the F or Q parameter will be underlined). For any filters that are off, a dash (“—”) will appear in the second column of the display. For fil­ters that are on, this is replaced by a small symbol rep­resenting the filter.
NOTE
If you wish to hear the effects of the filter while you are editing it, make sure the indicator above the filter selector is on. If not, press the appropriate selector to turn it on.
3
Use the F rotary encoder to alter the frequency of the filter.
4 For the notch filters, use the Q rotary encoder to alter
the Q of the notch. The figure shown is adjustable from
0.5 to 10.0 (10.0 is the narrowest). Of course, the HPF and LPF shelving filters do not take Q values.
YDP2006
18 – TUTORIAL – Setting up the input level, attenuation and delay
Setting up the input level, attenuation and delay
I. Input level and input attenuation
There are two operations on the YDP2006 that affect the input level—the input level control in the analog domain (pre A/D converters), and the attenuation parameter (INP.ATT) in the digital domain (post A/D converters).
The input level control (on the front panel) should be set so that the level meters register the highest possible level without the CLIP indicator lighting.
The input attenuation parameter is provided to compensate for equalizer settings that alter the overall gain of the sound. e.g. If the equalizer settings result in an overall gain increase of 4dB (for example), internal clipping may occur even if the level meters do not indicate clipping.
As a guide to input attenuation level, adjust it so that the output volume is the same as
when the bypass function is used. The attenuation can be set from 0dB to infinity (∞), with
the highest numerical value being shown as 50 (see instructions below).
II. Delay
In sound reinforcement situations, it is often desirable for the sound from various loud­speakers to be delayed, to compensate for phase delay caused by speaker placement. Due to its position in the signal chain, the equalization stage is a good place to add this delay.
The YDP2006 can delay signals by up to 714 milliseconds (242m, about 800ft) in stereo mode, or 1428 milliseconds (485m, about 1593ft) in mono mode. You can input this informa­tion either directly as milliseconds, or as a distance in feet or meters (set your preference in the “Utilities”). You can make individual settings for both channels, or for both channels at the same time by linking L and R. These settings are stored in the memory area along with the equalization settings.
1
Press the [PEQ] key until you see a screen similar to the one shown. The actual settings on your screen will probably be different to the ones shown here.
2 If you wish to alter both channels simultaneously, link
the channels.
3 Use the F rotary encoder to set the delay. To change the
units used (msec, meters or feet), see the “Utilities” sec­tion.
4 Use the G rotary encoder to enable (“ON”) or disable
(“OFF”) the delay you have set.
5 Use the Q rotary encoder to set the channel input
attenuation.
6 Don’t forget to store the completed settings in one of
the memory areas, so you can use them again at a later time.
YDP2006
19 – Specifications
Specifications
Frequency response 20Hz to 20kHz 0 ±1, 0dB
Dynamic range Emphasis ON typical, 110dB
> 104dB
Emphasis OFF typical, 106dB
> 100dB
Hum and noise Emphasis ON < -80dBm
Emphasis OFF <-76dBm
Distortion (max level, Emphasis ON) < 0.007%
(max level, Emphasis OFF) <0.01%
Inputs Channel inputs 2 (balanced)
Nominal input level +4/–20dBm (switchable)
Maximum input level +24dBm (switch at +4dB)
Input impedance 20k
Outputs Channel outputs 2 (balanced)
Nominal output level +4/–20dBm (switchable)
Maximum output level +24dBm (switch at +4dB)
Output impedance 150
A/D and D/A convertors A/D resolution 20-bit linear
D/A resolution 20-bit linear
Frequency response 44.1kHz
Memory areas 40 (all user-programmable)
MIDI control Program Change messages
select memory areas
Power requirements USA and Canadian model 120V/60Hz
General model 230V/50Hz
UK and Australian model 240V/50Hz
Power consumption (all models) 25W
Dimensions (w x d x h) mm (in) 480 x 335 x 45 (18.9 x 13.2 x 1.8)
Weight kg (lb) 4.6 (10.1)
(19” 1U rackmount)
YDP2006
YAMAHA [Digital Parametric Equalizer] date: 1993.10.22 Model: YDP2006
Function
Basic Channel
Mode
Note Number :True Voice
Velocity
After Touch
Pitch Bender X X
Default Changed
Default Messages Altered
Note ON Note OFF
Key’s Ch’s
MIDI Implementation Chart
Transmitted Recognized Remarks
X X
X X
**************
X
**************
X X
X X
XX
1 - 16, off 1 - 16, off
OMNI off/OMNI on
Version: 1.0
memorized
memorized X X
X X
X X
X X
Control
Change
Prog Change :True #
System Exclusive O O Bulk Dump
System
Common
System Real Time
Aux
Messages
:Song Pos :Song Sel :Tune
:Clock :Commands
:Local ON/OFF :All Notes OFF :Active Sense :Reset
XO*1
X X X
X X
X X X X
X X X
X X
X X X X
Notes: *1 = For program 1 - 128, memory 1 - 40 is selected.
Mode 1: OMNI ON, POLY Mode 3: OMNI OFF, POLY
Mode 2: OMNI ON, MONO Mode 4: OMNI OFF, MONO
O: Yes X: No
66 – User programs / Programmes utilisateur / User-Programme
User programs / Programmes utilisateur / User-Programme
Unit number: ________ Programmer: _____________ Backed up to: ________ Date: ______
Memory area
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Program name: Date: Comments:
YDP2006
67 – Program change table / Tableau de changement de programme / Program-Change-Tabelle
Program change table / Tableau de changement de programme / Program-Change-Tabelle
Unit number: ________ Bank: ________ Backed up to: ____________ Date: ________
Received Selects: Received Selects: Received Selects: Received Selects:
1336597 2346698 3356799 4 36 68 100 5 37 69 101 6 38 70 102 7 39 71 103 8 40 72 104
9 41 73 105 10 42 74 106 11 43 75 107 12 44 76 108 13 45 77 109 14 46 78 110 15 47 79 111 16 48 80 112 17 49 81 113 18 50 82 114 19 51 83 115 20 52 84 116 21 53 85 117 22 54 86 118 23 55 87 119 24 56 88 120 25 57 89 121 26 58 90 122 27 59 91 123 28 60 92 124 29 61 93 125 30 62 94 126 31 63 95 127 32 64 96 128
YDP2006
68 – Block diagram / Schéma de principe / Blockdiagramm
Block diagram / Schéma de principe / Blockdiagramm
LEVEL
INPUT INPUT
L
+4 -20
R
+4 -20
MIDI
IN
OUT
THRU
Y-485
LEVEL
Pre Emphasis
OFF ON
OFF ON
A/DHA
DSP
A/DHA D/A
CPU
D/A
De Emphasis
F G Q
OFF ON
OFF ON
LCD
KEY
LED
Rotary Encoder
ATT
+4 -20
ATT
+4 -20
OUTPUT
L
R
DSP
STEREO MODE
ATT
ATT
HPF
HPF
LPF
LPF
4-band
Notch
4-band
Notch
6-band
PEQ
6-band
PEQ
Delay
730ms
Delay
730ms
MONO MODE
L
ATT
R
HPF
LPF
4-band
Notch
4-band
Notch
6-band
PEQ
6-band
PEQ
Delay
1460ms
YDP2006
Dimensions / Abmessungen
/16")
3
4.9 (
/16")
50
15
(1
/16")
/16")
1
230.5 (9
3
305.4 (12")
D : 334.9 (13
69 – Dimensions / Abmessungen
440 (17 5/16")
/8")
1
/8")
1
28.5
(1
/16")
13
21 (
/4")
3
44
(1
H : 45.2
/16") 3.6 (
1
1.2 (<
All measurements given in mm (inches). Inch values given to nearest Toutes les mesures sont données en millimètres (pouces). Précision d’ Alle Maße in mm (Zoll). Zoll-Angaben mit einer Genauigkeit von 1/16”.
7
W : 480 (18
348 (13 11/16")
1
/
16 1
/16 pour les valeurs en pouces.
/8")
”.
Litiumbatteri! Bör endast bytas av servicepersonal. Explosionsfara vid felaktig hantering.
VAROITUS! Lithiumparisto, Räjähdysvaara. Pariston saa vaihtaa ainoastaan aian ammattimies.
ADVARSEL! Lithiumbatteri! Eksplosionsfare. Udskiftning mà kun foretages af en sagkyndig, – og som beskrevet i servicemanualen.
YDP2006
VQ95590 R2 1 CR 72
97 09 500 CR Printed in Japan
P.O.Box 1,Hamamatsu,Japan
documentation manual, user maintenance, brochure, user reference, pdf manual
This file has been downloaded from:
User Manual and User Guide for many equipments like mobile phones, photo cameras, monther board, monitors, software, tv, dvd, and othes..
Manual users, user manuals, user guide manual, owners manual, instruction manual, manual owner, manual owner's, manual guide,
manual operation, operating manual, user's manual, operating instructions, manual operators, manual operator, manual product,
Loading...