PM5D system software V1.12 includes the following changes and additions relative to V1.04 (changes up to V1.10 are also included).
Use ENCODER [ON] keys to turn phan­tom power (+48V) on/off (from V1.05)
A “USE ENCODER-ON AS +48V” option has been added to the PREFERENCE 1 screen. If this option is on, and HA (head amp input sensitivity) is selected as the encoder mode, you can use the ENCODER [ON] key located above each encoder to turn phantom power supply (+48V) on/off.
Switch parameter value indication on/ off in the Name display (from V1.05)
A “CHANNEL NAME NUMERIC DISPLAY” field has been added to the PREFERENCE 2 screen. In V1.04 and earlier, operating the fader or encoder (pan setting) of each chan­nel caused the name display to show the value of that parameter. In V1.05 and later, turning the “ENCODER VALUE” and “FADER VALUE” options off will prevent the respective parameter value from appearing when you oper­ate the fader or encoder.
Select the monitor source from the panel (from V1.05)
When selecting a monitor source from the panel in V1.04 or earlier, you could simultaneously select one source from [2TR A1]–[2TR D3] or [DEFINE] and one source from [STEREO A]/[STEREO B] (including LCR), for a maxi­mum total of two sources. In V1.05 and later, turning on one key will turn off the other keys, allowing you to select a single monitor source more rapidly. If you want to select two sources simultaneously (as in V1.04 and earlier), press the corresponding panel keys simultaneously, or use the MONITOR screen.
HA follows Recall Safe on/off operations (from V1.05)
A new SAFE KEY MODE SELECT section has been added to the RECALL SAFE screen. If you turn on the HA+CH button, using the [RECALL SAFE] key of the panel or the RECALL SAFE button in the CH VIEW screen (INPUT VIEW function) to turn Recall Safe on/off will now also turn on/off the Recall Safe setting for the HA patched to the corresponding channel. If the CH button is on, the HA Recall Safe setting will not be linked.
DCA group name Recall Safe and Selec­tive Recall can be switched on/off (from V1.05)
A new WITH NAME button has been added to the DCA area of the RECALL SAFE screen and SELECTIVE RECALL screen. This allows you to exclude just the DCA group name from DCA group Recall Safe and Selective Recall. If the WITH NAME button is on, Recall Safe and Selective Recall will apply to the DCA group names of DCA groups for which these functions are on. If the WITH NAME button is off, DCA group names are excluded from Recall Safe and Selective Recall.
PM5D V1.12 Supplementary Manual
Parameter operation for Recall Safe/ Selective Recall (from V1.12)
When using Recall Safe or Selective Recall, there has been a change in the behavior of parameters of which only one exists for each pair of adjacent odd-numbered/even-num­bered channels or modules (see owner's manual p.165). If Recall Safe or Selective Recall is specified for only one of these channels or modules, the parameters will behave as follows.
• PAIR
Forcibly turned off (pairing will be defeated).
• GATE STEREO LINK
• COMP STEREO LINK
• GEQ LINK
LINK parameters will be forcibly turned off (link will be defeated).
• DELAY GANG
• ATT GANG
GANG parameters will be recalled. If GANG turns On because of the recall, the relative differences of the DELAY and ATT parameter values following the recall will be maintained when they are edited.
• MS DECODE
• FIXED/VARI
These will not be recalled.
• PAN MODE
The PAN MODE parameter will be recalled. However, if the recall would cause the PAN MODE setting to change from BALANCE to some other setting, or from some other setting to BALANCE, then the PAN MODE and PAN parameters will not be recalled. Also, if the recall causes the PAN MODE to become GANG PAN, the rel­ative difference of the PAN parameter values following the recall will be maintained when they are edited.
Support for the Y96K card (from V1.10)
A PLUG-IN screen has been added to the EFFECT func­tion. Also, PLUGIN parameters have been added to the RECALL SAFE screen and SELECTIVE RECALL screen of the SCENE function. These additions are in order to sup­port the Y96K card that will become available in the near future from the Waves Corporation. For details on opera­tion, refer to the owner’s manual for the Y96K.
Please note that the Y96K card will operate as follows.
• Data will be stored/recalled as scene data, but the Undo function is not supported.
• If you power-off and then power-on the PM5D, con­ventional scene data will be in the same state as when you powered-off, but the Y96K will be in the state that was last stored or recalled.
• If you recall a scene that produces a major change in the settings of the Y96K, the settings of the Y96K will change several seconds after recall occurs on the PM5D. If you want the timing of the change to be synchronized, use the FADE TIME screen to specify a START OFFSET.
• Do not perform scene store/recall operations in the Y96K’s update waiting screen. If you do so, the screen will become inoperable for up to 30 seconds.
• The Scene Store operation saves the Y96K settings in the PM5D. If you executed Scene Store while the Y96K had previously been installed, and then once again store the scene with the Y96K not installed, the previous Y96K settings will remain. If a scene has never been stored while the Y96K is installed, recalling that scene with the Y96K installed will not affect the Y96K in any way.
• In PREVIEW mode, the PLUG-IN screen does not dis­play the Y96K status.
MIDI EVENT etc. data now maintained during scene recall (from V1.05)
The MIDI EVENT, GPI OUT CONTROL, and REMOTE TRANSPORT data included in a scene is now maintained when a scene recall occurs. This means that if you store a recalled scene into another scene, this data will be stored as it was when recalled.
DME series monitor source selection and EXTERNAL CUE on/off (from V1.05)
A MONITOR button and monitor source select button have been added to the DME CONTROL screen. When you click the monitor source select button ( ), the MONITOR POINT SELECT window will appear, letting you select the DME series unit monitor source. If the MONITOR button is on, the EXTERNAL CUE indicator in the upper part of the display will turn on, and the monitor signal of the DME series unit will be sent to the PM5D’s CUE bus.
Note
Before turning on the MONITOR button, you must select the same port as the monitor output on the DME series unit and as the monitor input for the PM5D. To specify the DME series unit monitor output, use the “Monitor Out” dialog box of DME Designer, accessed by [Tools] menu → [Monitor]. To specify the PM5D monitor input, use the MONITOR PORT field on the SETUP page of the DME CONTROL screen.
DME64N/24N version (from V1.12)
In order to use the DME CONTROL functionality, the PM5D must be V1.12 or higher, and all connected DME64N/24N units must be version 1.1 or higher.