Yaesu Musen VX 6000L User Manual

VX-6000L
OPERATING MANUAL
POWER
VERTEX STANDARD CO., LTD.
4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
17210 Edwards Rd., Cerritos, CA 90703, U.S.A.
International Division
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road, Kwun Tong, Kowloon, Hong Kong
Congratulations!
You now have at your fingertips a valuable communications tool - a two-way radio! Rugged, reliable and easy to use, your radio will keep you in constant touch with your colleagues for years to come, with negligible main­tenance down time.
Please take a few minutes to read this manual carefully. The information presented here will allow you to derive maximum performance from your radio. After reading it, keep the manual handy for quick reference, in case questions arise later on.
We’re glad you joined the team. Call on us any time, because our business is communications. Let us help you get your message across.
NOTICE
There are no user-serviceable points inside this transceiver. All service jobs must be referred to your Authorized Service Center or Network Administrator.
Safety / Warning Information
WARNING - DO NOT operate the VX-6000L radio when someone (bystanders)
outside the vehicle is within following range.
Safety Training information:
Antennas used for this transmitter must not exceed an antenna gain of 0 dB. The radio must be used in vehicle-mount configurations with a maximum operating duty factor not exceeding 50%, in typical Push-to-Talk configurations. This radio is restricted to occupational use, work related operations only where the radio operator must have the knowledge to control the exposure conditions of its passengers and bystanders by maintaining the minimum separation distance of following range. Failure to observe these restrictions will result in exceeding the FCC RF exposure limits.
Antenna Installation:
For rear deck trunk installation, the antenna must be located at least following range away from rear seat passengers in order to comply with the FCC RF exposure requirements. For roof top installation, the antenna must be placed in the center of the roof.
Radiated frequency and Distance
VX-6000L
1.55 m
VX-6000 Operating Manual
POWER
The VX-6000L is full-featured FM transceivers designed for flexible mobile and base station business communications in the VHF Low-Band (120/50 Watts: programmable) Land Mobile Bands. Each model is designed for reliable business communications in a wide variety of applications, with a wide range of operating capability provided by its leading-edge design.
The 250-channels memories can each be programmed with a 8-character channel name.
Important channel frequency data is stored in EEPROM and flash memory on the CPU, and is easily programmable by dealers using a personal computer and the VERTEX STAN­DARD CT-71 Programming Cable and CE35 Software.
The pages which follow will detail the many advanced features provided on the VX­6000L transceiver. After reading this manual, you may wish to consult with your Network Administrator regarding precise details of the configuration of this equipment for use in your application.
VX-6000 Operating Manual
Page 1
Front Panel
CONTROLS & CONNECTORS
!"#$
*
POWER
)
%
1 POWER Botton
Press the button to turn the transceiver ON and OFF.
TX Indicator
2
This lamp glows red when the radio is transmitting.
BUSY Indicator
3
This lamp glows green when the channel is busy.
Liquid Crystal Display
4
The display include an 8-character alpha-numeric section showing channel and group names, status and identity information, and error messages. Additional indicators on the display show priority channel assignments and scan include / exclude selection.
“CHANNEL RECALL” List
This channel on “HORN ALERT” List
This channel on
“OPTION” List
&'(
This channel on “INTERCOM” ListThis channel on “SELECTABLE TONE” List
Receiver MonitorThis channel on “PUBLIC ADDRESS” or
This channel on “SCAN” List
Channel Group Number
This channel on “AUX A/B/C” List
Page 2
8 Character Alpha-numeric Invertible Display
VX-6000 Operating Manual
CONTROLS & CONNECTORS
!!
""
!/
" Button
!!
5
6
7
8
9
10
11 Programmable Function Button (PF button)
""
Pressing these buttons changes the current group (and displayed group number or name). Holding this button for more than 1/2 second causes the function to repeat.
SQC Indicator
This lamp glows orange when incorrect position at the setting of CE35.
Programmable Function Button (PF button)
This button can be set up for special applications, such as high/low power selection, monitor, dimmer, talk-around, and call alert function, as determined by your network requirements and programmed by your VERTEX STANDARD dealer.
VOLUME Knob
This knob sets the volume of the receiver.
EMERGENCY Microphone
The emergency microphone is located behind this small slit. When the emergency feature is activated, this Microphone is enabled.
CHANNEL Selector Knob
This knob select the operating channel.
This button can be set up for special applications, such as high/low power selection, monitor, dimmer, talk-around, and call alert function, as determined by your network requirements and programmed by your VERTEX STANDARD dealer.
Side Panel
Microphone Jack (It is on both sides.)
Connect the microphone plug to this jack.
Microphone Jack