Mic-E:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
POSITION:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
WEATHER:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
OBJECT:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
ITEM:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
STATUS:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
OTHER:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
MY PACKET:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
MSG:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BNDCNT ALL10s
Reference
page
–
–
100
Page 2
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Set mode option No./
setting Item
9-9 APRS POPUPSet the beacon type, the message
9-10 APRS RINGERTurn on/off the bell when a bea-
9-11 APRS UNITSelect the units for APRS display. Position: MM.MM' / MM'SS'
9-12 APRS TX DELAYSet the data sending delay time. 100ms / 150ms / 200ms /
Description of function
type and the time of the popup
display.
con is received.
GRP:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
BLN:
OFF / ALL2s to ALL60s /
ALLCNT / BND2s to BND60s /
MY MSG:
OFF / BND2s to BND60s /
DUP.BCN:
OFF / BND2s to BND60s /
DUP.MSG:
OFF / BND2s to BND60s /
ACK.REJ:
OFF / BND2s to BND60s /
OTHER MSG:
OFF / BND2s to BND60s /
Mic-E: ON / OFF
POSITION: ON / OFF
WEATHER: ON / OFF
OBJECT: ON / OFF
ITEM: ON / OFF
STATUS: ON / OFF
OTHER: ON / OFF
MY PACKET: ON / OFF
MSG: ON / OFF
GRP: ON / OFF
BLN: ON / OFF
MY MSG: ON / OFF
DUP.BCN: ON / OFF
DUP.MSG: ON / OFF
ACK.REJ: ON / OFF
OTHER MSG: ON / OFF
TX BCN: ON / OFF
TX MSG: ON / OFF
Distance: km / mile
Speed: km/h / knot / mph
Altitude: m / ft
Temp: °C / °F
Rain: mm / inch
Wind: m/s / mph
250ms / 300ms / 400ms /
500ms / 750ms / 1000ms
Setting Item
(Bold letters: Default)
BNDCNT ALL10s
BNDCNT ALL10s
BND10s
BND10s
BND10s
BND10s
BND10s
Reference
page
–
–
Functions Used As Needed
–
–
101
Page 3
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Set mode option No./
setting Item
9-13 BEACON INFOSet the transmission beacon in-
9-14 BEACON
INTERVAL
9-15 BEACON STATS
TXT
9-16 BEACON TXSelect automatic or manual send-
9-17 COM PORT
SETTING
9-18 DIGI PATHSelect a digital repeater route.P1 OFF
Functions Used As Needed
9-19 GPS DATUMSelect a datum used for the GPS
9-20 GPS POWERTurn on/off the GPS function.GPS ON / GPS OFF–
9-21 GPS TIME SETTurn on/off the GPS time and date
9-22 GPS UNITSelect the units for GPS display. Position: .MMM' / 'SS''
9-23 CALLSIGN (APRS) Specify the callsign of your sta-
9-24 MY POSITIONSet the position for your station. GPS / Lat N * **°**.**' /
9-25 MY SYMBOLSet the symbol for your station.45 Icon–
WGS-84 / Tokyo Mean /
Tokyo Japan / Tokyo Korea /
Tokyo Okinawa
AUTO / MANUAL–
Speed: km/h / Knot / mph
Altitude: m / ft
LON* **°**.**'
P1 to P10
Setting Item
(Bold letters: Default)
OFF / 1 dig to 4dig
4800 / 9600 / 19200 / 38400
NMEA9 / NMEA6 / NMEA7 /
NMEA8
––
Reference
page
–
–
–
–
–
–
–
–
102
Page 4
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Set mode option No./
setting Item
9-26 POSITION
COMMENT
9-27 SmartBeaconingSet the smart beaconing function. STATUS:
9-28 TIME ZONESet the time zone.UTC ±13.0 H / UTC+0:00–
* For more details of functions, refer to the APRS Section in the instruction manual.
10 SD CARD
10-1 BACKUPWrite or read the information
10-2 MEMORY CHWrite or read the memory channel
10-3 GROUP IDWrite or read GROUP ID infor-
10-4 FORMATFormat the micro SD memory
11 OPTION
11-1 USB CAMERASet the USB CAMERA image size
12 CALLSIGNSet the CALLSIGN.–141
Description of function
Set up the position comment function.
about your transceiver into or
from the micro SD memory card.
information into or from the micro
SD memory card.
mation into or from the micro SD
memory card.
card.
and resolution.
Off Duty / En Route /
In Service / Returning /
Committed / Special / Priority /
Custom 0 to 6 / EMERGENCY!
LOW SPD: 2mph to 30mph
HIGH SPD: 31mph to 90mph
SLOW RATE: 1min to 100min
FAST RATE: 10sec to 180sec
TURN ANGL: 5° to 90°
TURN SLOP: 1 to 255
TURN TIME: 5sec to 180sec
Write to SD / Read from SD138
Write to SD / Read from SD138
Write to SD / Read from SD139
Format24
SIZE: 160×120 / 320×240
QUALITY: LOW / NORMAL /
Setting Item
(Bold letters: Default)
OFF / TYPE1 / TYPE2 / TYPE3
HIGH
Reference
page
140
–
–
Functions Used As Needed
Displaying the GPS screen.
When using the GPS function, you can display the GPS information on the LCD.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
4 Turn O to select [1 GPS INFO].
5 Press H to display the GPS information on the LCD.
103
Page 5
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Setting the display method of the remote station information
Set the display method of the remote station information when using the GM Function.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
4 Turn O to select [2 TARGET LOCATION].
5 Press H.
6 Turn O to select the display method.
COMPASS: Compass appears.
NUMERIC: Longitude and latitude appear.
7 Press p to set the selected display method, and exit from
the Set mode.
Caution
When the NUMERIC is selected, only the location information of the remote station appears on the
LCD. The BACKTRACK function is not activated.
Setting the display method for BACKTRACK
You can set the BACKTRACK screen display method.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
Functions Used As Needed
4 Turn O to select [3 COMPASS].
5 Press H.
6 Turn O to select the display method.
HEADING UP: Heading direction is indicated upward.
NORTH UP: North direction is indicated upward.
7 Press p to save the selected display setting and exit the
set mode.
104
Page 6
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Setting the search channels for the BAND SCOPE function
You can set the number of channels to be displayed for the band scope when the BAND
SCOPE function is used.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
4 Turn O to select [4 BAND SCOPE].
5 Press H.
6 Turn O to select the number of channels to search for.
11ch / 19ch / 33ch / 49ch / 101ch
Remark Default: 33ch
7 Press p to set the number of channels to search for, and
exit the Set mode.
Changing the Lighting Condition
You can change the LCD and key lighting condition.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
4 Turn O to select [5 LAMP].
䎶䎨䎷 䎝 䎃䎃䎔䎃 䎧 䎬 䎶 䎳䎯䎤䎼
䎃䎃䎃䎃䎃䎃䎃䎃䎕 䎃 䎷 䎻 䎒 䎵 䎻
䎃䎃䎃䎃䎃䎃䫹䎃 䎖䎃 䎰䎨䎰 䎲䎵䎼
䎃䎃䎃䎃䎃䎃䎃䎃䎗 䎃 䎶 䎬 䎪 䎱 䎤 䎯 䎬 䎱䎪
5 Press H.
6 Turn O to select a lighting condition.
Select a lighting condition with reference to the following
table:
DisplayLighting Condition
2 SEC (KEY) to
10 SEC (KEY)
CONTINUOUSThe LCD and keys light up continuously.
OFFThe LCD and keys do not light.
When O dial or a key is pressed, the LCD
and keys light up for the set time.
7 Press p to save the lighting condition, and exit the Set mode.
105
Page 7
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Selecting a Display Language
You can select a display language from Japanese and English.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
4 Turn O to select [6 LANGUAGE].
5 Press H.
6 Turn O to select a language.
Select [JAPANESE] or [ENGLISH].
Remark Default: Japanese
7 Press p to save the selected display language, and exit
the Set mode.
Adjusting the LCD Contrast Level
You can adjust the LCD contrast level.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
4 Turn O to select [7 LCD CONTRAST].
5 Press H.
Functions Used As Needed
6 Turn O to select a contrast level.
Select from among LEVEL 1 (LIGHT) to LEVEL 15 (DARK).
Remark Default: LEVEL 7
7 Press p to save the selected contrast, and exit the Set
7 Press p to save the selected display brightness level, and
exit the Set mode.
䎃 䎛 䎃 䎯 䎦 䎧 䎃 䎧 䎬 䎰 䎰䎨䎵
䎃 䎃䎃䎃䎃䎃䎯 䎨 䎹 䎨 䎯 䎃 䎙
䎃
Changing the Opening Message Displayed
Immediately after Power-on
You can select the message displayed under the “YAESU” logo from among four types:
“no message”, “power supply voltage”, “message comprising up to 16 characters”, and
“callsign”.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
4 Turn O to select [9 OPENING MESSAGE].
5 Press H.
Functions Used As Needed
107
Page 9
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
6 Turn O to select the display method.
Select a message type with reference to the following table:
Remark Default: CALLSIGN
DisplayDisplay Condition
NORMALThe YAESU logo appears immediately after power-on.
OFFImmediately after power-on, the reception frequency, etc. appear without display-
DCThe power supply voltage and time appear immediately after power-on.
MESSAGEA message comprising up to 16 characters ap-
CALLSIGNYour callsign appears immediately after power-on.
ing an opening message.
pears immediately after power-on.
Pressing H displays the message registration
screen. Enter a message to be displayed following
the procedure described in “Assigning a Name to a
Memory Channel” (See page 47).
7 Press p to save the selected display method, and exit from the Set mode.
Measuring the Battery Voltage and the Transceiver Temperature
Power Supply Voltage Measurement Function/Temperature
Measurement Function
You can measure the battery voltage and the temperature inside the transceiver. When
the optional external power supply adapter with a cigarette plug (SDD-13) is connected,
the power supply voltage of this adapter is measured.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
Functions Used As Needed
3 Press H.
4 Turn O to select [10 SENSOR INFO].
䎶䎨䎷 䎝 䎃䎃䎔䎃 䎧 䎬 䎶 䎳䎯䎤䎼
䎃䎃䎃䎃䎃䎃䎃䎃䎕 䎃 䎷 䎻 䎒 䎵 䎻
䎃䎃䎃䎃䎃䎃䫹䎃 䎖䎃 䎰䎨䎰 䎲䎵䎼
䎃䎃䎃䎃䎃䎃䎃䎃䎗 䎃 䎶 䎬 䎪 䎱 䎤 䎯 䎬 䎱䎪
5 Press H.
The voltage and temperature appear on the LCD.
Remark When the temperature appears on the LCD, pressing V
toggles the unit of temperature display between °C and °F.
• The display changes as follows depending on the type of the power supply used.
Battery pack: “Lit”
Battery case: “Dry”
External power supply adapter: “Ext”
• During mono band reception, the voltage can be displayed on the LCD constantly (See page 27).
• This function displays the temperature inside the transceiver.
• In a situation where the temperature inside of the transceiver does not rise (e.g., standby reception),
you can know the approximate outside temperature from the temperature displayed on the LCD.
Changing the Display Pattern of the PO Meter
You can select a display pattern of the S/PO meter from among four types.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [1 DISPLAY].
3 Press H.
4 Turn O to select [11 S-METER SYMBOL].
5 Press H.
6 Turn O to select a display pattern.
Remark Default:
7 Press p to save the selected display pattern, and exit from
the Set mode.
Switching between AM Antennas
You can switch antennas when listening to AM broadcast stations.
For details, see “Switching between AM Antennas” on page 33.
Reducing receiver sensitivity
Attenuator (ATT) Function
If the signal from the remote station is too strong or, a strong signal is present nearby that
interferes with reception, use the attenuator (ATT) function.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
Functions Used As Needed
109
Page 11
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
4 Turn O to select [1 MODE].
5 Press H.
6 Turn O to select [2 ANTENNA ATT].
7 Press H.
8 Turn O to select [ON].
Remark Default: OFF
9 Press p to save the attenuator function setting, and exit
the Set mode.
Tip
• The amount of attenuation by the attenuator (ATT) is about 10 dB.
Setting the transmission modulation level
You can set the transmission modulation level to half of its usual level.
Set [OFF] for normal amateur operation.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [1 MODE].
5 Press H.
6 Turn O to select [3 HALF DEVIATION].
7 Press H.
Functions Used As Needed
8 Turn O to select [ON]
Remark Default: OFF
9 Press p to save the transmission modulation level is set,
and exit the Set mode.
110
Page 12
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Changing the mode manually
Manually switch to an optimum mode (radio wave type) according to the frequency band.
For more details, see “Changing the Mode Manually” on page 38.
Switching between digital and analog mode
You can set digital and analog mode switching and digital transmission mode.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [2 DIGITAL].
5 Press H.
6 Turn O to select [1 DIGITAL MODE].
7 Press H.
8 Turn O to select [MODE].
9 Press H.
10
Turn O to select your desired mode.
DIGITAL: Transmit and receive in the digital mode.
ANALOG: Transmit and receive in the analog mode.
AMS (Automatic Mode Select):
Tune to the transmission and reception mode of the remote
station from which a signal is automatically received.
11 Press M.
12
Turn O to select [DIGI TX].
13
Press H.
14
Turn O to select a reception mode.
DN: Usual digital communication mode. Conversation is
infrequently interrupted even under low power level.
VW: (Voice Wide) Full rate high quality sound mode This is the transmission function
to prioritize the sound quality when the communication condition of the remote
station is relatively good.
15
Press p to save the setting and exit the Set mode.
Functions Used As Needed
111
Page 13
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Setting the AMS transmission mode
When operating in the AMS function, the transmit mode may be selected:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [2 DIGITAL].
5 Press H.
6 Turn O to select [1 DIGITAL MODE].
7 Press H.
8 Turn O to select [AMS MODE].
9 Press H.
10
Turn O to select the AMS transmit mode.
TX M: The operating mode is automatically selected
from four communication modes to match the
received signal. Pressing the Microphone [PTT]
momentarily, toggles between the Digital and
Analog communication modes.
TX FM: The RX mode is automatically selected from the
four communication modes to match the received
signal. The TX mode is automatically changed to
the “FM” mode.
TX DN: The RX mode is automatically selected from the
four communication modes to match the received
signal. The TX mode is automatically changed to
the “DN” mode.
TX VW: The RX mode is automatically selected from the four communication modes
Functions Used As Needed
AUTO: The RX and TX operating mode is automatically selected from the four
Remarks • Default: TX M
• Blink “
11
Press p to save the setting and exit the Set mode.
to match the received signal. The TX mode is automatically changed to the
“VW” mode.
communication modes to match the received signal.
▎” : TX M
▎
Blink “
OO” : TX FM / TX DN / TX VW
The OO symbol display differs according to the received signal.
112
Page 14
Setting the squelch type for the digital mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
You can set the squelch type for the digital mode.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [2 DIGITAL].
5 Press H.
6 Turn O to select [2 SQL TYPE].
7 Press H.
8 Turn O to select [SQL TYPE].
9 Press H.
10
Turn O to select a squelch type.
OFF: Voice is always output upon receiving a digital signal
from a Yaesu transceiver.
CODE: Voice is output only when receiving a signal with a
corresponding SQL CODE.
BREAK: Voice is output regardless of any squelch code
when the remote station transmits with BREAK set.
11 Press M.
12
Turn O to select [SQL CODE].
13
Press H.
14
Turn O to enter a code.
You can enter SQL CODE of 126 types from 001 to 126.
15
Press p to save the SQL CODE setting and exit the Set mode.
Set Mode
Setting the pop up time of the remote station information
You can set the time duration to display the remote station information, such as callsign,
on the LCD.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [2 DIGITAL].
5 Press H.
Functions Used As Needed
113
Page 15
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
6 Turn O to select [3 DIGI POPUP].
7 Press H.
8 Turn O to select the display method.
OFF: Does not display the remote station information.
BND2s to 60s: Set the time to display the remote station
information (2 to 60 seconds).
BNDCNT: Always display the remote station information.
Remark Default: 10 seconds
9 Press p to save the pop up time setting and exit the Set mode.
Setting the Standby Beep
When communicating in a digital mode, a beep is sounded after the end of the other
stations transmission.
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [2 DIGITAL].
5 Press H.
6 Turn O to select [5 STANDBY BEEP].
7 Press H.
8 Turn O to select [OFF]/[ON].
OFF: Disable the STANDBY BEEP feature.
ON: Enable the STANDBY BEEP feature.
Remark Default: ON
9 Press p to exit from the Set mode.
Functions Used As Needed
114
Page 16
Displaying the version of the DSP program
䎶䎨䎷䎝䎃䎃䎕䎃䎷䎻䎒䎵䎻
䎃䎃䎃䎃䎃䎃䎃䎃䎖䎃䎰䎨䎰䎲䎵䎼䎃䎃䎃䎃䎃䎃䎃䎃䎗䎃䎶䎬䎪䎱䎤䎯䎬䎱䎪䎃䎃䎃䎃䎃䎃䎃䎃䎘䎃䎶䎦䎤䎱
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
You can check the DSP program version of the built in digital unit of the transceiver.
First enter the digital mode, and then enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [2 DIGITAL].
5 Press H.
6 Turn O to select [6 DSP Ver].
7 Press H.
The version of the DSP program appears on the LCD.
8 Press p to exit from the Set mode.
Adjusting the microphone sensitivity Microphone Gain
You can adjust the input level of the built-in microphone or an optional external microphone.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [3 AUDIO].
5 Press H.
6 Turn O to select [1 MIC GAIN].
䎖 䎃 䎤 䎸 䎧 䎬 䎲
䎔 䎃 䎰䎲䎧䎨
䎃 䎕 䎃 䎧 䎬 䎪 䎬 䎷 䎤 䎯
7 Press H.
8 Turn O to select a microphone sensitivity level.
Select a microphone gain level from the following:
LEVEL 1 (Lowest sensitivity) to LEVEL 9 (Highest sensitivity)
• Increasing the microphone gain excessively can distort the sound or pick up the surrounding noise,
impairing intelligibility.
• Be sure to adjust the microphone gain whenever you change microphones.
Muting Voice
In the dual reception mode, the audio being received on the non-operating band is muted
when a signal is herd on the operating band.
For more details, see “Muting Audio” on page 35.
Simultaneously radio broadcast reception
Set the mute time of the simultaneous broadcast reception.
For more details, see “AF-DUAL Function” for simultaneously monitoring the amateur
frequency while listening to the broadcast radio.
Changing the sound volume setting method
You can set the sound volume adjustment mode to be automatically canceled after about
3 seconds, after pressing v and then adjusting the sound volume with O.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [2 TX/RX].
3 Press H.
4 Turn O to select [3 AUDIO].
5 Press H.
6 Turn O to select [4 VOL MODE].
Functions Used As Needed
7 Press H.
8 Turn O to select [AUTO BACK].
Remark Default: NORMALTip Usually adjust the sound volume by turning O while pressing
v. If the [AUTO BACK] is selected, the sound volume
adjustment mode will be automatically canceled after you have
pressed v to enter the sound volume adjustment mode and
return to the frequency display screen.
9 Press p to exit the Set mode.
116
Page 18
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Setting memory bank link
You can link multiple registered memory banks, and also recall a frequently used memory
bank immediately
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [3 MEMORY].
3 Press H.
4 Turn O to select [1 BANK LINK].
5 Press H.
6 Turn O to select a memory bank to link.
7 Press B.
The cursor moves to the position (such as BANK1) to set
link.
8 Turn O to select [ON].
Remark Default: OFF
9 Press B.
10
Also set link to other memory banks.
Set link to each memory bank from memory bank 1 through
memory bank 24 by repeating step 6 to 9.
11 Press H.
The memory bank link is set.
12
Press p.
Exits from the Set mode.
Assigning a name to a memory bank
A memory bank can be assigned a name with up to 16 characters.
For more details, see “Assigning Name to Memory Bank” on page 49.
Assigning a name to a memory channel
Memory channels and home channels may be assigned a name (memory tag) such as a
callsign or broadcast station name.
For more details, see “Using Memory Tag” on page 46.
Functions Used As Needed
117
Page 19
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Prohibiting registration to memory channel
Memory Channel Protect Function
A memory channel may be protected so that a new frequency or memory channel tag
name cannot be registered to it.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [3 MEMORY].
3 Press H.
4 Turn O to select [4 MEMORY PROTECT].
5 Press H.
6 Turn O to select [ON].
Any registration to the memory channel is prohibited.
Remark Default: OFF
7 Press p to save the memory channel protect, and exit the
Set mode.
Setting memory skip function
Set the scan method for scanning memory channels.
For more details, see “Specifying a Skip/Selected Memory Channel” on page 60.
Registering to a memory channel with the lowest memory channel
number
Memory Channel Write Function
When registering to a memory channel. you can display an unregistered memory channel
with the lowest memory channel number.
Enter the Set mode:
Functions Used As Needed
1 Press and hold M for over 1 second.
2 Turn O to select [3 MEMORY].
3 Press H.
4 Turn O to select [6 MEMORY WRITE].
5 Press H.
6 Turn O to select [LOWER].
A memory channel with the lowest memory channel number
appears on the LCD.
Remark Default: NEXT
7 Press p to set the memory channel registration to the
lowest unregistered memory channel number, and exit from
the Set mode.
118
Page 20
Notifying a call from a remote station by the bell
䎶䎨䎷䎝䎃䎃䎗䎃䎶䎬䎪䎱䎤䎯䎬䎱䎪
䎃䎃䎃䎃䎃䎃䎃䎃䎘䎃䎶䎦䎤䎱䎃䎃䎃䎃䎃䎃䫹䎙䎃䎪䎰䎃䎃䎃䎃䎃䎃䎃䎃䎚䎃䎺䎬䎵䎨䎶䙵䎻
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Notifies you of a call from a remote station by the bell.
See “Notification of a Call from a Remote Station by the Bell” on page 89.
Selecting a DCS code
Select the DCS code from 104 codes from 023 to 754.
For more details, see “Setting a DCS Code” on page 86.
Transmit and receive a DCS Code with a inverted phase
DCS INVERSION Function
You can transmit and receive a DCS code with an inverted phase when using the digital
code squelch function.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [4 SIGNALING].
3 Press H.
4 Turn O to select [3 DCS INVERSION].
The phase of DCS code is set, and exits from the Set mode.
Set Mode
Functions Used As Needed
119
Page 21
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Setting the transmission method of the DTMF code
Set the transmission method of the registered DTMF code.
For more details, see “Sending the Registered DTMF Code” on page 80.
Setting DTMF code
The maximum of 16 digit DTMF code can be registered for a telephone number to make
a call through the public telephone line from a phone patch.
For more details, see “Using DTMF Function” on page 79.
Calling only a specific station
New Pager Function
When using transceivers with your friends, specifying personal codes allows only a
specific station to be called.
For more details, see “Calling Only a Specific Station New Pager Function” on page 90.
Enabling no-communication squelch function
PR FREQUENCY Function
You can set a no-communication squelch frequency in steps of 100 Hz within the range
from 300 Hz to 3000 Hz.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [4 SIGNALING].
3 Press H.
4 Turn O to select [7 PR FREQUENCY].
5 Press H.
6 Turn O to tune in to a frequency.
Functions Used As Needed
Select no-communication squelch frequency in steps of 100
Hz.
Remark Default: 1600 Hz
7 Press p to set the no-communication squelch function,
and exit the Set mode.
120
Page 22
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Adjusting the squelch level SQL LEVEL Function
You can set squelch level to mute the raspy noise heard.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [4 SIGNALING].
3 Press H.
4 Turn O to select [8 SQL LEVEL].
Setting the signal strength to output sound
S Meter Squelch Function
You can set A-Band and B-Band individually to output the sound only when receiving a
signal stronger than signal strength level set to the S-Meter Level.
1 Select a band as an operating band.
2 Press and hold M for over 1 second to enter the Set
mode.
3 Turn O to select [4 SIGNALING].
4 Press H.
5 Turn O to select [9 SQL S-METER].
6 Press H.
7 Turn O to select a setting value.
Select a S-Meter level with reference to the table shown
below.
Remark Default: OFF
8 Press p to save the selected S-Meter level, and exit the
Set mode.
Functions Used As Needed
121
Page 23
Set Mode
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
DisplayS-Meter DisplayOperating Status
OFFNo display
S-Meter squelch function is OFF.
(By default, S-Meter squelch function is set to OFF.)
Level 1
Level 2
Level 3
Level 4
Level 5
Level 6
Level 7
Level 8
Level 9
Outputs the sound of signal stronger than the S-Meter level 1.
Outputs the sound of signal stronger than the S-Meter level 2.
Outputs the sound of signal stronger than the S-Meter level 3.
Outputs the sound of signal stronger than the S-Meter level 4.
Outputs the sound of signal stronger than the S-Meter level 5.
Outputs the sound of signal stronger than the S-Meter level 6.
Outputs the sound of signal stronger than the S-Meter level 7.
Outputs the sound of signal stronger than the S-Meter level 8.
Outputs the sound of signal stronger than the S-Meter level 9.
Setting the squelch type for transmission and reception
SQL EXPANTION FUNCTION
Squelch types set beforehand can function separately for transmission and reception.
Enter the Set mode:
Functions Used As Needed
1 Press and hold M for over 1 second.
2 Turn O to select [4 SIGNALING].
3 Press H.
4 Turn O to select [10 SQL EXPANTION].
5 Press H.
6 Turn O to select [ON].
ON: Use separate squelch for transmission and reception.
OFF: Use the same squelch for transmission and reception.
Remark Default: OFF
7 Press p to save the separate squelch setting, and exit the
Set mode.
122
Page 24
Setting the type of tone squelch
䎶䎨䎷䎝䎃䎃䎗䎃䎶䎬䎪䎱䎤䎯䎬䎱䎪
䎃䎃䎃䎃䎃䎃䎃䎃䎘䎃䎶䎦䎤䎱䎃䎃䎃䎃䎃䎃䫹䎙䎃䎪䎰䎃䎃䎃䎃䎃䎃䎃䎃䎚䎃䎺䎬䎵䎨䎶䙵䎻
ApplicationforFCC/IC
FCCID:K6620445X20
IC:511B-20445X20
Set the tone squelch to open the squelch only when a signal containing the specified
frequency tone is received.
For more details, see “Using the Tone Squelch Function” on page 84.
Selecting a tone frequency
Select the tone frequency from 50 types between 67.0 MHz and 254.1 MHz.
For more details, see “Setting a Tone Frequency” on page 85.
Setting the sound and speed during tone search
Tone Search Function
Sound can be muted during tone search. The operation speed of the tone search can
also be changed.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [4 SIGNALING].
3 Press H.
4 Turn O to select [13 TONE-SRCH].
Setting the Weather Alert Feature, used for notifying storms and hurricanes, ON or OFF.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [4 SIGNALING].
3 Press H.
4 Turn O to select [14 WX ALERT].
5 Press H.
6 Turn O to select [ON].
ON: Enables the Weather Alert Feature.
OFF: Disables the Weather Alert Feature.
Remark Default: OFF
7 Press p to save the Weather Alert ON or OFF setting, and exit the Set mode
Setting the surveillance interval time for priority channels
DW TIME Function
When the dual reception function is active, the interval for monitoring the signal of the
priority channel can be set.
Enter the Set mode:
1 Press and hold M for over 1 second.
2 Turn O to select [5 SCAN].
3 Press H.
4 Turn O to select [1 DW TIME].
䎶䎨䎷䎝䎃䎃䎘䎃 䎶 䎦 䎤 䎱
䎃䎃䎃䎃䎃䎃䎃䎃䎙 䎃 䎪䎰
䎃䎃䎃䎃䎃䎃䫹䎚 䎃 䎺 䎬 䎵 䎨 䎶䙵䎻
䎃䎃䎃䎃䎃䎃䎃䎃䎛 䎃 䎦䎲 䎱 䎩 䎬 䎪
5 Press H.
6 Turn O to select the monitoring interval.
Interval can be selected from 0.1 SEC to 10 SEC.
Functions Used As Needed
Remark Default: 5 seconds
䎔 䎃 䎧䎺䎃 䎃䎷 䎬 䎰 䎨
䎕 䎃 䎶䎦䎤䎱䎃 䎃䎯 䎤䎰䎳
䎃䎖䎃 䎶䎦䎤䎱䎃 䎃䎵 䎨䙵䎶 䎷 䎤 䎵 䎷
䎃 䎗 䎃 䎶䎦䎤䎱䎃䎃䎵 䎨䎶䎸䎰䎨
7 Press p to save the priority memory channel monitoring
interval setting and exit the Set mode.
䎔 䎃 䎧䎺䎃 䎃䎷 䎬 䎰 䎨
䎃 䎃䎃䎃 䎃 䎘 䎑 䎓
䎃
䏖䏈䏆
124
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.