4-8-8 Nakameguro, Meguro-Ku, Tokyo 153-8644, Japan
VERTEX STANDARD
US Headquarters
10900 Walker Street, Cypress, CA 90630, U.S.A.
YAESU EUROPE B.V.
P.O. Box 75525, 1118 ZN Schiphol, The Netherlands
YAESU UK LTD.
Unit 12, Sun Valley Business Park, Winnall Close
Winchester, Hampshire, SO23 0LB, U.K.
VERTEX STANDARD HK LTD.
Unit 5, 20/F., Seaview Centre, 139-141 Hoi Bun Road,
Kwun Tong, Kowloon, Hong Kong
INTRODUCTION
FCC ID: K6610443240
IC ID: 511B-10443240
Vertex Standard Co., Ltd.
The VXR-9000 is commercial-grade 50-watt FM repeater designed to provide reliable two-way full-duplex communications over a wide range of environmental conditions.
Designed to mount in a standard 19-inch rack, the VXR-9000 is crafted using the latest computer-aided design and
manufacturing processes, to ensure a high level of reliability to users. Important channel frequency data is stored in
EEPROM, and is easily programmable by a Servicing Technician or Dealer using an IBM compatible personal computer and the VPL-1 Programming Cable and CE60 Software.
Please take a few minutes to read this manual carefully. The information presented here will allow you to derive
maximum performance from your VXR-9000. After reading it, keep this manual handy for quick reference, in case
questions arise later on.
Important Note: Internal service work, programming, and accessory installations should only be performed by your
authorized Vertex Standard Dealer. Dangerous conditions and/or possibly illegal operation may result from improper setup, programming, or internal modifications.
SAFETY/W ARNINGINFORMATION
The antenna(s) used for this transmitter must be fixed-mounted on outdoor permanent structures with a
separation distance of at least 100cm from all persons during normal operation and must not exceed an
antenna gain of 0 dBd. This device must be restricted to work related operations in an Occupational/Controlled RF exposure Environment, not exceeding a maximum transmitting duty factor of 50%. The antenna(s)
used with this device must satisfy the antenna co-location requirements of 47 C.F.R. 1.1307(b)(3).
VXR-9000 FM REPEATER OPERATING MANUAL
NOTICE!
r Do not modify this repeater for any reason.
Refer service of this repeater to qualified technicians only.
r Should an obviously abnormal condition be observed, such as overheating, a burning smell, etc., turn the
main power switch off, and disconnect the AC plug from the AC mains supply or wall outlet immediately.
r Do not place any combustible material near the repeater.
r Do not spray any liquid over the repeater.
r Ensure that the power and antenna connections are securely made, using cables with excess capacity for
the power being utilized.
FRONT PANEL CONTROLS & CONNECTORS
FCC ID: K6610443240
IC ID: 511B-10443240
Vertex Standard Co., Ltd.
‡ ˆ ‰Š
‚•ƒ „†…
POWER (O/I) Switch
•
This is the main power switch for the repeater.
Power Indicator (MAIN
‚
This LED glows green when the main power source
is used.
Power Indicator (BACKUP
ƒ
This LED glows red when the backup power source
is used.
MIC Jack
„
Connect the microphone plug to this jack. This jack
is also used for writing and reading channel frequency or other configurations via the COM Port of
the PC on which the clone editor (CE60) is running.
Programmable Function (PF) Key
…
Six pushbuttons on the front panel are programmable function (PF) keys, each with an orange indicator inside. Each key can be programmed with
two functions, one for a “long” press and one for a
“momentary” press. The PF key functions may be
customized, via programming by your VERTEX
STANDARD dealer, to meet your communications
network requirements. Note that some functions
may require the purchase of optional internal accessories. The possible PF key features and functions are explained on the pages to follow.
)
)
TX Indicator
‡
This LED glows red when the repeater is transmitting.
Numeric Display
ˆ
This display consists of two 7-segment LEDs, indicating the channel number during normal operation. If an abnormal condition arises, an error code
will be displayed:
DISPLAYDESCRIPTION
01 - 32Channel Number
PCClone Active
ULPLL Unlock
HIHigh temperature in PA Unit
SCScan Active
LCFront Panel Keys are Locked
E1PTT key is Disabled
E2Cooling Fan is Disabled
E5Low Voltage in Backup Battery
E7PA Unit Abnormality
E3, E4, E6 , E9 Contact your Dealer
BUSY Indicator
‰
This LED glows green when the receiving channel
is busy.
Speaker
Š
The internal speaker is located here.
VOL Knob
†
This control knob adjusts the output level of the
front speaker and external speaker jack on the back
panel.
VXR-9000 FM REPEATER OPERATING MANUAL
PROGRAMMABLE FUNCTION (PF) KEY DETAILS
FCC ID: K6610443240
IC ID: 511B-10443240
Vertex Standard Co., Ltd.
FUNCTION
CH DOWN
CH UP
COMPANDER
CTCSS/DCS ENC
CTCSS/DCS DEC
CW ID
TWO TONE DEC
CW ID SIGNAL
CW MESSAGE 1
CW MESSAGE 2
CW MESSAGE 3
CW MESSAGE 4
CW MESSAGE 5
CW MESSAGE 6
CW MESSAGE 7
CW MESSAGE 8
DC POWER SAVE
ENCRYPTION
ENCRYPTION CODE
KEY LOCK
LOCAL PTT
MONITOR
MONITOR M
MULTI TONE
PANEL INDICA TOR
REMOTE
REPEA T
RESET
SCAN
SQUELCH
TEST TONE
TEST TONE M
TOT
TRANSMIT
TX POWER MID
TX POWER LOW
PF-1 KEY
P
RESSPRESS
& H
OLD
PF-2 KEY
P
RESSPRESS
& H
OLD
PF-3 KEY
P
RESSPRESS
& H
OLD
PF-4 KEY
P
RESSPRESS
& H
OLD
PF-5 KEY
P
RESSPRESS
& H
OLD
PF-6 KEY
P
RESSPRESS
& H
OLD
CH DOWN
Press (or Press and hold in for one second) the PF key
assigned to “CH Down” to step to the next-lower operating channel.
CH UP
Press (or Press and hold in for one second) the PF key
assigned to “CH Up” to step to the next-higher operating channel.
COMPANDER
Press (or Press and hold in for one second) the PF key
assigned to “Compander” to turn the Compander circuit “On” or “Off” (toggle). This function is only activated on the “Narrow Channel Spread” of the “BaseTransceiver” mode.
The Compander IC contains two variable gain circuits
configured for compressing and expanding the dynamic
range of the repeater’s transmitted and received audio
signal. When you enable this function, the signal-tonoise ratio can be improved by reducing the transmitted audio dynamic range.
CTCSS/DCS ENC
Press (or Press and hold in for one second) the PF key
assigned to “CTCSS/DCS Enc” to turn the CTCSS/DCS
Encoder “On” or “Off” (toggle).
CTCSS/DCS DEC
Press (or Press and hold in for one second) the PF key
assigned to “CTCSS/DCS Dec” to turn the CTCSS/DCS
Decoder “On” or “Off” (toggle).
CW ID
Press (or Press and hold in for one second) the PF key
assigned to “CW ID” to turn the CW Identifier feature
“On” or “Off” (toggle).
When the CW ID feature is set to “On,” your station’s
callsign will be superimposed on the outbound signal,
in Morse Code, at the beginning of every transmission.
Programming of the callsign is performed by your VERTEX STANDARD dealer.
VXR-9000 FM REPEATER OPERATING MANUAL
PROGRAMMABLE FUNCTION (PF) KEY DETAILS
FCC ID: K6610443240
IC ID: 511B-10443240
Vertex Standard Co., Ltd.
TWO TONE DEC
Press (or Press and hold in for one second) the PF key
assigned to “Two Tone Dec” to turn the 2-Tone Decoder
“On” or “Off” (toggle).
CW ID SINGLE
Press (or Press and hold in for one second) the PF key
assigned to “CW ID Single” to send the station callsign,
via Morse Code, once. Programming of the callsign is
performed by your VERTEX STANDARD dealer.
CW MESSAGE 1 - CW MESSAGE 8
Press (or press and hold in for one second) the PF key
assigned to “CW Message 1 - 8” to send a pre-programmed Morse Code message on the transmitted signal. Programming of the message(s) is performed by
your VERTEX STANDARD dealer.
DC POWER SAVE
Press (or Press and hold in for one second) the PF key
assigned to “DC Power Save” to turn the DC Power
Save feature “On” or “Off” (toggle).
When DC Power Save feature is set to “ON,” activate
the various power save feature (determined from your
VERTEX STANDARD dealer) while the repeater operates from the Backup Power Source.
ENCRYPTION
Press (or Press and hold in for one second) the PF key
assigned to “Encryption” to turn off the Optional Encryption Unit temporarily.
MONITOR
Press (or Press and hold in for one second) the PF key
assigned to “Monitor” to cancel CTCSS and DCS squelch
decoding, so as to enable reception of signals present on
the channel that do not contain a matching CTCSS tone
or DCS code.
MONITOR M
This function provides to “Monitor” to cancel CTCSS
and DCS squelch decoding, so long as the PF key assigned to “Monitor M” is pressed and held in.
MULTI TONE
Press (or Press and hold in for one second) the PF key
assigned to “Multi Tone” to switch the Tone Table between “Main” and “Sub.”
PANEL INDICA TOR
Press (or Press and hold in for one second) the PF key
assigned to “Panel Indicator” to turn the Front Panel’s
Illumination “On” or “Off” (toggle).
REMOTE
Press (or Press and hold in for one second) the PF key
assigned to “Remote” to toggle the operating mode between the “Remote” mode and “Local” mode.
When the “Remote” mode is selected, the repeater operates according to the control instructions received
from the external device (connected to the ACC jack on
the rear panel). While in the “Local” mode, the repeater
operates from the front panel’s PF keys.
ENCRYPTION CODE
Press (or Press and hold in for one second) the PF key
assigned to “Encryption Code” to select the Encryption
Code (determined from your VERTEX STANDARD
dealer; require the FVP-35 Rolling Code Encryption
Unit).
KEY LOCK
Press (or Press and hold in for one second) the PF key
assigned to “Key Lock” to lock the repeater’s front panel
keys (except “Key Lock” key); this feature can be enabled to prevent repeater settings from being disturbed.
LOCAL PTT
Press (or Press and hold in for one second) the PF key
assigned to “Local PTT” to enable (“On”) or disable
(“Off”) operation using a PTT switch connected to the
front panel’s Microphone Jack.
REPEA T
Press (or Press and hold in for one second) the PF key
assigned to “Repeat” to toggle the operating mode between the “Repeater” mode and “Base Transceiver”
mode.
For normal operation, set this key to the “Repeat” mode.
When the “Base Transceiver” mode is selected, you can
speak into the microphone to use this repeater as a transceiver.
RESET
Press (or Press and hold in for one second) the PF key
assigned to “Reset” to reset (same function as the
POWER switch “off” and “on”) the repeater.
VXR-9000 FM REPEATER OPERATING MANUAL
Loading...
+ 9 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.