Xyratex RS-1600-FC-SBD, RS-1602-FC-SBD Installation And User Manual

RS-1600-FC-SBD and RS-1602-FC-SBD Installation and User Guide
Part No. 46329-01A
Issue 1.0
12 January, 2004
The information in this document is subject to change without notice.
While every effort has been made to ensure that all information in this document is accurate, the Authors accept no liability for any errors that may arise.
No part of this document may be transmitted or copied in any form, or by any means, for any purpose, without the written permission of the Authors.
Acknowledgments
Issue 1.0 12 January, 2004 Part No. 46329-01A
ii
RS-1600/1602-FC-SBD User Guide
All names, brands, products or services are trademarks or registered trademarks of their respective companies.
Contents
iii
Contents
Preface ................................................................................................................................................. vii
International Standards .................................................................................................................. ... .. .. vii
Potential for Radio Frequency Interference .......................................................................................... vii
European Regulations ................................. ... ..................................... .. ............................................... viii
Safety .................................................................................................................................................... viii
Rack System Precautions ...................................................................................................................... xi
ESD Precautions .................................................................................................................................. xii
Data Security ................................................................................................................... ... .. ................ xii
Special Tools and Equipment ........................................................................................................... .. .. xii
Related Documentation ........................................................................................................................ xiii
Revision History .................................................................................................................................... xiii
1 Introduction ..................................................................................................................................... 1
1.1 RS-1600-FC-SBD and RS-1602-FC-SBD Subsystems .............................................................. 1
1.2 The Enclosure Core Product ....................................................................................................... 2
1.2.1 Enclosure Chassis .............................................................................................................. 2
1.2.2 Tower Option ....................................................................................................... ............... 3
1.3 The Plug-in Modules ................................. ... .................................... ... ........................................ 4
1.3.1 Power Supply/Cooling Module ........................................................................................... 4
1.3.2 Operators Panel ................................................................................................................. 6
1.3.3 SBD Input/Output Module .................................................................................................. 7
1.3.4 Drive Carrier Module ........................................................................................................ 11
1.3.5 Dummy Carrier Modules .................................................................................................. 12
1.3.6 Blank Modules .................................................................................................................. 12
1.4 Visible and Audible Alarms ........................................................................................................ 12
1.5 RS-1600-FC-SBD & RS-1602-FC-SBD Technical Specifications ............................................. 13
1.5.1 Dimensions ....................................................................................................................... 13
1.5.2 Weight .............................................................................................................................. 13
1.5.3 AC Power (450W PSU) ........................................................ ... ... ...................................... 13
1.5.4 -48V DC Power (450W PSU) .................................... ..................................... .. ................ 14
1.5.5 PSU Safety and EMC Compliance ................................................................................... 14
1.5.6 Power Cords ..................................................................................................................... 14
1.5.7 Environment ..................................................................................................................... 15
1.5.8 Interfaces ...............................................................................................................
........... 15
1.5.9 SBD Module Specification ................................................................................................ 16
1.5.10 Drive Carrier Module Specification ................................................................................... 17
1.5.11 SCSI Enclosure Services (SES) Support ......................................................................... 17
iv
RS-1600/1602-FC-SBD User Guide
2 Getting Started .............................................................................................................................. 19
2.1 Introduction ............................................................................................................................... 19
2.2 Planning Your Installation ......................................................................................................... 19
2.2.1 Enclosure Bay Numbering Convention ............................................................................ 20
2.3 Enclosure Installation Procedures ............................................................................................. 21
2.3.1 Pre-Requisites ................................................................................................................. 21
2.3.2 Rack Mounting Rail Kit ..................................................................................................... 21
2.3.3 Chassis Installation .......................................................................................................... 22
2.4 Power Supply/Cooling Module Installation ................................................................................ 23
2.4.1 Parts Check List ............................................................................................................... 23
2.4.2 AC Power Supply/Cooling Module Procedure ................................................................. 23
2.4.3 -48V DC Power Supply/Cooling Modul e Pro ce dure ........................................................ 25
2.5 SBD Module Installation ............................................................................................................ 29
2.5.1 Parts Check List ............................................................................................................... 29
2.5.2 Procedure ........................................................................................................................ 29
2.6 SBD Module Configurations ...................................................................................................... 31
2.6.1 Internal Loop Structures ............................................... ... ..................................... ............ 31
2.7 FC-AL Interface ......................................................................................................................... 31
2.7.1 Connecting Multiple Enclosures ....................................................................................... 31
2.8 Drive Enclosure Device Addressing .......................................................................................... 34
2.8.1 Drive Start ...................................................... .................................. ... ............................. 35
2.9 Drive Carrier Configuration ...................................................................................................... 36
2.9.1 Planning and Configuring Your Installation ...................................................................... 36
2.10 Drive Carrier Installation ............................................................................................................ 36
2.10.1 Parts Check List ............................................................................................................... 36
2.10.2 Procedure ........................................................................................................................ 36
2.10.3 Dummy Carrier Modules .................................................................................................. 39
2.10.4 Engaging the Anti-tamper Locks ...................................................................................... 39
2.11 Power Cord Connection ............................................................................................................ 39
2.11.1 Parts Check List ............................................................................................................... 39
2.11.2 Procedure ........................................................................................................................ 40
2.12 Grounding Checks .................................................................................................................... 40
3 Operation ....................................................................................................................................... 41
3.1 Before You Begin ...................................................................................................................... 41
3.2 Power On ............................ ... ................................................................................................... 41
3.2.1 Power Supply/Cooling Module LEDs ............................................................................... 42
3.3 Ops Panel LEDs .............................................................................................................
........... 42
3.4 Starting the Drives ..................................................................................................................... 43
3.4.1 Disk Drives LEDs ............................................................................................................. 43
3.5 Power Down ............................................................... ............................................................... 43
4 Troubleshooting and Problem Solving .......................................................... ............................. 45
4.1 Overview ................................................................................................................................... 45
4.1.1 Initial Start-up Problems ................................................................................................... 45
4.2 LEDs ......................................................................................................................................... 46
4.2.1 Power Supply/Cooling Module LEDs ............................................................................... 46
4.2.2 Ops Panel LEDs .............................................................................................................. 47
4.2.3 SBD Module LEDs ........................................................................................................... 49
4.2.4 Drive Carrier LEDs ........................................................................................................... 49
4.3 Audible Alarm ............................................................. ............................................................... 49
Contents
v
4.3.1 Audible Alarm Mute .......................................................................................................... 49
4.4 Drive Carrier Module Faults ...................................................................................................... 50
4.4.1 Dummy Carrier Modules ................................................................................................. 50
4.4.2 Auto Start Failure ............................................................................................................. 50
4.5 Troubleshooting ......................................................................................................................... 51
4.5.1 System Faults ................................................................................................................... 51
4.5.2 Power Supply/Cooling Faults ........................................................................................... 51
4.5.3 Thermal Control ..................................... ... ..................................... ................................... 52
4.5.4 Thermal Alarm ........................................................... ....................................................... 53
4.5.5 Thermal Warnings ..................................................... ... .................................... ................ 54
4.6 Dealing with Hardware Faults ................................................................................................... 54
4.7 Continuous Operation During Replacement .............................................................................. 54
4.8 Replacing a Module ........................................................................................ ... ........................ 55
4.8.1 Power Supply/Cooling Modules ....................................................................................... 55
4.8.2 Ops Panel ......................................................................................................................... 60
4.8.3 SBD Module ..................................................................................................................... 61
4.8.4 Drive Carrier Module ........................................................................................................ 63
4.9 Spare Parts and Ancillary Items .................... ..................................... ... .. ................................. 63
Glossary ................................................................................................................................................ 65
Index ..................................................................................................................................................... 67
vi
RS-1600/1602-FC-SBD User Guide
Preface
vii
Preface
What is in this guide
This user guide gives you step-by-step instructions on how to install, configure and connect an RS-1600­FC-SBD or RS-1602-FC-SBD storage subsystem to your host computer system, and how to use and maintain the system.
Who should use this guide
This user guide assumes that you have a working knowledge of the Fibre Channel Arbitrated Loop (FC­AL) environment into which you are installing your RS-1600-FC-SBD or RS-1602-FC-SBD subsystem and are familiar with switched connectivity technology . If you do not have these skills, or are not confident with the instructions in this guide, do not proceed with the installation.
International St andards
The RS-1600-FC-SBD and RS-1602-FC-SBD storage subsystems comply with the requirements of the following agencies and standards:
• CE to IEC 950/EN60950
•UL
•cUL
Potential for Radio Frequency Interference
USA Federal Communications Commission (FCC)
Note This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. The supplier is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user’s authority to ope rate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RS-1600/1602-FC-SBD User Guide
viii
European Regulations
This equipment complies with European Regulations EN 55022 Class A: Limits and Methods of Measurement of Radio Disturbance Characteristics of Information Technology Equipments and EN50082-1: Generic Immunity.
Safety
All plug-in modules are part of the fire enclosure and must only be removed when a replacement can be immediately added. The system must not be run without all units in place.
Permanently unplug the unit if you think that it has become damaged in any way and before you move it.
Drive Carrier Module Caution Label: Do not operate with modules missing; Spin down time 30 seconds
• An RS-1600-FC-SBD or RS-1602-FC-SBD enclosure can weigh up to 37kg (81lb). Do not try to lift it by yourself.
Chassis Warning Label: Weight Hazard
• Do not lift RS-1600-FC-SBD or RS-1602-FC-SBD populated enclosures by the handles on the Power Supply/Cooling module, they are not designed to support the weight of the populated enclosure.
• In order to comply with applicable safety, emission and thermal requirements no covers should be removed and all bays must be fitted with plug-in modules.
• RS-1600-FC-SBD and RS-1602-FC-SBD subsystems must only be operated from a power supply input voltage range of 100 - 120 VAC or 200-240 VAC.
• The plug on the power supply cord is used as the main disconnect device. Ensure that the socket outlets are located near the equipment and are easily accessible.
• The equipment is intended to operate with two working Power Supply/Cooling modules.
Preface
ix
SBD Module Caution Label: Do not operate with modules missing
Power Supply/Cooling Module Caution Label: Do not operate with modules missing
• A faulty Power Supply/Cooling module must be replaced with a fully operational module within 24 hours.
• If powered by multiple AC sources, disconnect all supply power for complete isolation.
PSU Warning Label: Power Hazards
• The power connection should always be disconnected prior to removal of the Power Supply/Cooling module from the enclosure.
• A safe electrical earth connection must be provided to the power cord. Check the grounding of the enclosure before applying power.
• Provide a suitable power source with electrical overload protection to meet the requirements laid down in the technical specification.
Warning Do not remove covers from the Power Supply/Cooling module. Danger of electric sho ck inside.
Return the Power Supply/Cooling module to your supplier for repair.
RS-1600/1602-FC-SBD User Guide
x
PSU Safety Label: Electric Shock Hazard Inside
Caution If this equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Fibre Channel Host & Expansion Connectors.
Important If fitted with Optical modules, the modules must be a UL (or other North American NRTL)
RECOGNISED COMPONENT and the laser in the module must comply with Laser Class 1, US 21 CFR (J) and EN 60825-1.
If passive copper cables are connected, the cable must not have a connection to a common ground/earth point.
-48V DC PSU/Cooling Module Safety Requirements
The following paragraphs summarize additional safety requirements to be observed when installing or operating a -48V DC Power Supply/Cooling module: Please refer to section
2.4.3.1, ”-48V DC PSU Safety Requirements”, on page 25 for full details of European and North American safety requirements
applicable to this module.
Voltage Rating
The marked rated voltage for the -48VDC Power Supply/Cooling module is -40V DC to -60V DC. Th e equipment is intended to operate from a centralized dc supply system with a NOMINAL voltage of -48V DC or -60V DC.The voltage from a nominal -48V DC system may vary, due to float charging or discharge conditions, from -40V DC to -60V DC.The voltage from a nominal -60V DC system may vary, due to float charging or discharge conditions, from -48V DC to -72V DC.
Caution If this equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Equipment Location
The rear of this Equipment (in particular the supply terminals and wiring to the terminals on the power supply) must only be located in a “RESTRICTED ACCESS LOCATION” where both of the following apply (Ref.UL60950):
• access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and
• access is through the use of a TOOL or lock and key, or other means of security and is controlled by the authority responsible for the location.
Disconnect Device
The wiring installation must provide a disconnect device close to the product.
Wiring
Must be connected in accordance with the local and National wiring regulations.
Preface
xi
Wire Temperature Rating
The supply wiring to the power supply terminal blocks must have a minimum temperature rating of 75ºC.
mu
Circuit Protection
The building installation must provide overcurrent and short circuit protection in the non earthed suppl y conductor.
-48V DC PSU: USA and Canadian Safety Requirements
Wiring Methods
Wiring method must be code compliant in the field. Wiring methods must be in accordance with the U.S. National Electric Code, Article 300.
Earthing
This equipment is designed to permit the connection of the earthed conductor (+) of the DC supply circuit to the earthing conductor at the equipment.
Protective Earth Conductor Size
The protective earth conductor size must be suitable for the maximum fault current that the installation can provide. U.S. National Electric Code, Article 250-122
Branch Circuit Protection
The PSU must be connected to a Branch circuit that is protected by a LISTED Branch Protector. Th e rating of the LISTED Branch Protector >= 125% of the product rating and the rating of the LISTED Branch Protector =< current rating of wire supplying the equipment. U.S. National Electric Code, Article 210-3, Article 240.
Rack System Precautions
The following safety requirements must be considered when the unit is mounted in a rack.
• The rack design should incorporate stabilizing features suitable to prevent the rack from tipping or being pushed over during installation or in normal use.
• When loading a rack with the units, fill the rack from the bottom up and empty from the top down.
• System must be operated with low pressure rear exhaust installation (Back pressure created by rack doors and obstacles not to exceed 5 pascals [0.5mm Water gauge])
• The rack design should take into consideration the maximum operating ambient temperature for the unit, which is 35°C with a single Power Supply/Cooling module fitted and 40°C when dual Power Supply/Cooling modules are fitted.
• The rack should have a safe electrical distribution system. It must provide overcurrent protection for the unit and must not be overloaded by the total number of units installed in the rack. Consideration of the units nameplate rating should be used when addressing these concerns.
• The electrical distribution system must provide a reliable earth for each unit and the rack.
RS-1600/1602-FC-SBD User Guide
xii
• Each power supply in each unit has an earth leakage current of 1.7mA. The design of the electrical distribution system must take into consideration the total earth leakage current from all the power supplies in all the units. The rack will require labelling with "HIGH LEAKAGE CURRENT. Earth connection essential before connecting supply".
• The rack when configured with the units must meet the safety requirements of UL 60950 and IEC
60950.
ESD Precautions
Caution It is recommended that you fit and check a suitable anti-static wrist or ankle strap and observe all
conventional ESD precautions when handling RS-1600-FC-SBD or RS-1602-FC-SBD plug-in modules and components. Avoid contact with backplane compon ents and module connectors, etc.
Data Security
• Power down your host computer and all attached peripheral devices before beginning installation.
• Each enclosure contains up to 16 removable disk drive modules. Disk units are fragile. Handle them with care, and keep them away from strong magnetic fields.
All the supplied plug-in modules and blanking plates must be in place for the air to flow correctly around the enclosure and also to complete the internal circuitry.
• If the subsystem is used with modules or blanking plates missing for more than a few minutes, the enclosure can overheat, causing power failure and data loss. Such use may also invalidate the warranty.
• If you remove any drive module, you may lose data.
– If you remove a drive module, replace it immediately. If it is faulty, replace it with a drive module
of the same type and capacity
• Ensure that all disk drives are removed from the enclosure before attempting to manhandle or move the rack installation.
• Do not abandon your backup routines. No system is completely foolproof.
Special Tools and Equipment
There are no special tools required but in order to complete the assembly of some configurations you may need the following (not supplied):
• Security keys (one of these should be included with your RS-1600-FC-SBD or RS-1602-FC-SBD enclosure for use with the drive locks).
Preface
xiii
Related Documentation
• RS-1600-FC-SBD and RS-1602-FC-SBD Quick Installation Guide (P/N 46328-01)
• RS-Salient Series Rack Installation Guide (P/N 43638-02)
Revision History
Version Date Description of Change
1.0 January, 2004 Initial Release
RS-1600/1602-FC-SBD User Guide
xiv
Introduction
1
Chapter 1
Introduction
1.1 RS-1600-FC-SBD and RS-1602-FC­SBD Subsystems
Figure 1–1 Typical S torage Subsystem Enclosure
RS-1600/1602-FC-SBD User Guide
2
1.2 The Enclosure Core Product
The RS-1600-FC-SBD and RS-1602-FC-SBD design concept is based on a subsystem together with a set of plug-in modules. The RS-1600-FC-SBD or RS-1602-FC-SBD subsystem as supplied comprises:
• Chassis and Backplane with integral Operators Panel.(See Figure 1–10)
• Up to 16 FC Drive Carrier modules (See Figure 1–12) Note: There are two versions of the drive carrier available, for RS-1600 or RS-1602 chassis. They
are not interchangeable as the RS-1602 drive carrier is longer (approximately 44mm) than that for the RS-1600 chassis.
• Dummy drive carrier modules.
•Two Power Supply/Cooling plug-in modules, two variants are available:
– .AC, 450W PSU (see Figure 1–5) – -48V DC 450W PSU (see Figure 1–6)
• Two plug-in LRC Input/Output Modules, with integrated 20-port Fibre Channel Switch and optional FC Target SES interface device. These constitute an SBOD (Switched Bunch of Discs) module with1Gb/2Gb external operating speed, optionally known as an SBD module (See
Figure 1–8).
1.2.1 Enclosure Chassis
The chassis consists of a sheet metal enclosure assembly containing a Backplane printed circuit board (PCB) and module runner system. This chassis assembly also includes an integral Operators (Ops) Panel, mounted at the rear.
The RS-1602 series chassis is longer than the RS-1600 series chassis, to accommodate the longer RS­1602 variant drive carrier modules but is otherwise identical.
The chassis assembly contains 16 drive bays at the front, each of which accommodates the appropriate plug-in drive carrier module. The 16 drive bays are arranged in 4 rows of 4 drives. At the rear, the chassis assembly contains the integral Ops panel module and four plug-in module bays to house two Power Supply/Cooling modules and two SBD modules.
The Backplane PCB provides logic level signal and low voltage power distribution paths. Figure 1–2 and
Figure 1–3 show front and rear views of a populated chassis respectively.
The chassis is fitted with 19 inch Rack mounting features which enables it to be fitted to standard 19 inch racks and uses 3EIA units of rack space.
• A Bay is defined as the space required to house a single 1.0" high 3.5 inch disk drive in its carrier module. e.g. a 1 x 4 bay module would take the space of 1 drive width by 4 drive bays high (in rack mount configuration).
• A 4 x 4 Chassis fitted with 19 inch Rack mounting features enables it to be fitted to standard 19 inch racks. It uses 3EIA units of rack space
Introduction
3
.
1.2.2 Tower Option
An optional tower kit is available, which can be fitted to the rack chassis described here.
Figure 1–2 Enclosure Chassis (Front)
Figure 1–3 Enclosure Chassis (Rear)
Figure 1–4 T o wer Option
RS-1600/1602-FC-SBD User Guide
4
1.3 The Plug-in Modules
An RS-1600-FC-SBD or RS-1602-FC-SBD Enclosure requires the following modules for normal operation:
• 2 x Power Supply/Cooling modules
• 1 x Operator Panel
• 2 x SBD (I/O) modules
• Up to 16 drive carrier modules and/or d ummy drive carrier modules, as required.
Note No drive bays should be left completely empty.
1.3.1 Power Supply/Cooling Module
Two variants of the Power Supply/Cooling module are available for the RS-1600-FC-SBD and RS-1602­FC-SBD subsystems:
• Auto ranging AC 450W Power Supply/Cooling module
• -48V DC 450W Power Supply/Cooling module
Warning Do not mix Power Supply/Cool ing modules of different types.
1.3.1.1 AC Power Supply/Cooling Module
Two Power Supply/Cooling modules (Figure 1–5) are supplied mounted in the rear of the enclosure as part of the subsystem core product.
.
Figure 1–5 AC Power Supply/Cooling Module
Introduction
5
PSU voltage operating ranges are nominally 115V or 230V AC, selected automatically.
.
Four LEDs mounted on the front panel of the Power Supply/Cooling module (see Figure 2–1) indicate the status of the PSU and the fans.
1.3.1.2 -48V DC Power Supply/Cooling Module
A -48V DC Input Power Supply/Cooling Module variant is also available (Figure 1–6).
Warning The -48V DC Power Supply/Cooling module is not an operator removable part. It should only be
removed by a technician who has knowledge of the hazards present within the module.
1.3.1.3 Multiple Power Supply/Cooling Modules
The RS-1600-FC-SBD or RS-1602-FC-SBD must always be operated with two Power Supply/Cooling modules fitted. The two Power Supply/Cooling modules operate together so that if one fails the other maintains the power supply and cooling while you replace the faulty unit.
Module replacement should only take a few minutes to perform but must be completed within 10 minutes from removal of the failed module.
Figure 1–6 -48V DC Power Supply/Cooling Module
RS-1600/1602-FC-SBD User Guide
6
1.3.2 Operators Panel
Supplied as an integral part of the Enclosure core product, a typical Operators (Ops) Panel is shown in
Figure 1–7.
The Ops Panel provides the enclosure with a micro controller which is used to monitor and control all elements of the Enclosure.
1.3.2.1 Ops Panel Indicators and Switches
The Ops Panel includes Light Emitting diodes (LEDs) which show the status for all modules, an Audible Alarm which indicates when a fault state is present, a push-button Alarm Mute switch and a thumb wheel SEL_ID Address Range selector switch.
The Ops Panel switch functions are shown in Table 1–1.
Figure 1–7 Ops Panel
Introduction
7
Caution All mandatory settings must be observed in order for the RS-1600-FC-SBD system to function correctly.
Important Switch settings are only read at Power On.
Note The Ops Panel is not user replaceable.
1.3.3 SBD Input/Output Module
The RS-1600-FC-SBD and RS-1602-FC-SBD storage subsystems each include an enclosure with rear facing bays which house two SBD modules. These are Loop Resiliency Circuit (LRC) Input/Output modules with integrated 20-port Fibre Channel Arbitrated Loop Switch.
The plug-in SBD modules have been designed for integration into a RS-1600-FC-SBD or RS-1602-FC­SBD storage subsystem, providing external FCAL cable interfacing with the host computer system
The FC-AL Backplane incorporates connection to each of the switch ports within the SBD modules.
At any host port this appears as one FC-AL logical loop.
The SBD module internal processor monitors error conditions on each disk drive port and will automatically isolate device that causes excessive FC errors or cannot communicate correctly. Under these conditions the drive’s amber LED will be set to Flash and the status (2Gb) LED on the SBD module will Flash to indicate which loop the problem has been identified on.
Table 1–1 Ops Panel Switch Functions (Default settings for RS-1600-FC-SBD or RS-1602-FC-SBD
SBD module usage at 2Gb/s)
Switch Number
Function Recommended Setting Definition
1 Loop Select,
Single (1x16)
On SBD operated on single loop of 16 drives
Mandatory 2 Not Used 3 Not Used 4 Not Used 5 & 6 Not Used 7 & 8 Drive Loop Speed
Select
Sw7 Sw8
On Off Force 2Gb/s Off Off Force 1Gb/s
9 & 10 Drive Addressing
Mode Selection
Sw9 Sw10
On On Mode 0 Off On Mode 1
11 SOFT SELECT On Select functions using the hardware
switches 12 Not Used
RS-1600/1602-FC-SBD User Guide
8
Processors housed on the SBD modules provide enclosure management interfacing to devices on the Backplane, PSU, SBD module and Ops Panel, to monitor internal functions.These processors operate in a master slave configuration to allow failover.
The module incorporates the follo w i n g LED in d icators:
Host
LED Functions LED State Description Host Port 0 Signal Good Green incoming FC signal GOOD Host Port 1 Signal Good Green incoming FC signal GOOD Host Port 2 Signal Good Green incoming FC signal GOOD Host Port 3 Signal Good Green incoming FC signal GOOD Status Green
OFF
Flashing
All device ports GOOD @ 2Gb/s All device ports GOOD @ 1Gb/s
Drives bypassed on module
SBD Module Fault Amber SBD module FAILED
Figure 1–8 SBD Module
Introduction
9
The SBD module operates at 1 or 2 Gb/s.
• The SBD module has four external ports with Small Form Factor Pluggable (SFP) GBIC modules, with auto-bypass at the output ports. Any of these SFPs can be used as an IN or OUT connector, providing either connection to the host controllers or expansion connections, up to a maximum of 5 additional enclosures in Address Mode 1 or 6 additional enclosures in Address Mode 0.
• Insertion or removal of any device connection to an active host, or insertion or removal of a drive, will cause a LIP to occur. (This feature may be optionally disabled, please contact your supplier for details).
• If the multi-port trunking feature is enabled then a string of enclosures may be connected with a maximum of 2 FC interconnect cables between each enclosure. Without this feature only 1 FC link may be used in a string of enclosures.
• All 4 host connectors may be routed to separate hosts, the internal switch will provide non blocking FC-AL data routing to all devices in the enclosure.
• The module also incorporates an RS232, 6 pin Mini-DIN connector (factory use only)
Figure 1–9 SBD Module Front Panel
RS-1600/1602-FC-SBD User Guide
10
Other models in the RS-1600/1602 product ranges are available in 1Gb/2Gb, JBOD or RAID variants for operation with Fibre Channel or Serial ATA drives, by changing the LRC modules. Please contact your supplier for details.
Figure 1–10 Enclosure with SBD Modules and AC PSUs Installed
Figure 1–11 Enclosure with SBD Modules and -48VDC PSUs Installed
Introduction
11
1.3.4 Drive Carrier Module
The Drive Carrier Module comprises a hard disk mounted in a carrier. Each drive bay will house a single Low Profile 1.0 inch high, 3.5 inch form factor disk drive in its carrier.The carrier has mounting locations for FC-AL drives.
Each disk drive is enclosed in a die-cast aluminum carrier which provides excellent thermal conduction, radio frequency and electro-magnetic induction protection and affords the drive maximum physical protection.
The front cap also supports an ergonomic handle which provides the following functions:
• Camming of carrier into and out of drive bays.
• Positive 'spring loading' of the drive/backplane connector.
• An anti-tamper lock operated by a torx socket type key.
Two versions of the drive carrier (Figure 1–12) are offered, for installation in RS-1600 or RS-1602 chassis. They are not interchangeable as the RS-1602 drive carrier is longer (approximately 44mm) than that for the RS-1600 chassis.
1.3.4.1 Drive Status Indicators
Each drive carrier incorporates two indicators, an upper (Green) and lower (Amber). In normal operation the green indicator will be ON and will flicker as the drive operates.
1.3.4.2 Anti-tamper Locks
Anti-tamper locks are fitted in the drive carrier handles (Figure 1–13) and are accessed through the small cutout in the latch section of the handle.These are provided to disable the normal ‘pinch' latch action of the carrier handle.
Figure 1–12 Drive Carrier Module: (unpopulated) for RS-1600 Enclosure
RS-1600/1602-FC-SBD User Guide
12
1.3.5 Dummy Carrier Modules
Dummy carrier modules are provided for fitting in all unused drive bays. They are designed as integral drive module front caps with handles and must be fitted to all unused drive bays to maintain a balanced airflow.
1.3.6 Blank Modules
Warning Operation of the Enclosure with ANY modu les missing will disrupt th e airflow and th e drives will
not receive sufficient cooling. It is ESSENTIAL that all apertures are filled before operating the unit. Dummy Carriers and/or Blank modules are available for this purpose.
1.4 Visible and Audible Alarms
The functional modules have associated status LEDs. The Ops Panel shows a consolidated status for all modules.
LEDs show constant green for good or positive indication. Constant Amber LEDs indicate there is a fault present within that module.
The Ops Panel also incorporates an Audible Alarm to indicate when a fault state is present and also an Alarm Mute push-button.
Warning The Ops Panel is an integral part of the enclosure chassis assembly and can only be replaced by
trained personnel.
Figure 1–13 Anti-tamper Lock
Introduction
13
1.5 RS-1600-FC-SBD & RS-1602-FC-SBD Technical Specifications
1.5.1 Dimensions
It is recommended that a rack with a depth of no less than 700mm is used with this product.
1.5.2 Weight
1.5.3 AC Power (450W PSU)
Rack Enclosure inches mm Height 5.13 134 Width across mounting flange 19 483 Width across body of enclosure 17.6 447 Depth from flange to rear of enclosure body • RS-1600
• RS-1602
19.69 21
500 532
Depth from flange to maximum extremity of enclosure (rear hold down)
• RS-1600
• RS-1602
20.12
20.55
511 551
Depth from flange to furthest extremity at front of unit 0.67 17
Tower Enclosure inches mm Height 19.72 501 Width (including mounting feet) 9.06 230 Depth • RS-1600
• RS-1602
20.12
23.24
511
523
Maximum Configuration Rack mount:
Tower:
37kg (81lb) 40kg (88lb)
Empty Enclosure (Rack) 9kg (19.8lb) PSU/Cooling Module 4kg (8.8lb) SBD Module 0.9kg (1.98lb) Tower Conversion Kit 3kg (6.6lb)
Voltage Range 100-120 / 200-240 VAC Rated Voltage Range Selection Automatic Frequency 50/60 Hz Inrush Current 50A @ 260VAC Power Factor >0.98 Harmonics Meets EN61000-3-2
RS-1600/1602-FC-SBD User Guide
14
1.5.4 -48V DC Power (450W PSU)
1.5.5 PSU Safety and EMC Compliance
1.5.6 Power Cords
1 United States
Must be NRTL LISTED (National Recognized Test Laboratory, e.g. UL)
2 Europe & Others
General requirements:-
Important The Plug and the complete power cord assembly must meet the standards appropriate to the
country, and must have safety approvals acceptable in that country.
DC Input Voltage Range -40V to -60V DC Rated DC Line Inrush Current 50A peak Rated Current 17 A
Safety Compliance UL 60950
IEC 60950 EN 60950
EMC Compliance CFR47 Part 15B Class A
EN55022 EN55024
Cord type SV or SVT, 18 AWG minimum, 3 conductor, 4.5 M max length. Plug NEMA 5-15P grounding-type attachment plug rated 120V 10A;
or
IEC 320 C14, 250V, 10A.
Socket IEC 320, C-13, 250V, 10A.
Cord type Harmonized, H05-VVF-3G1.0 Socket IEC 320, C-13, 250V, 10A.
Introduction
15
1.5.7 Environment
1.5.8 Interfaces
Table 1–2 Ambient Temperature and Humidity
Temperature Range Relative Humidity Max. Wet Bulb
Operational 5°C to 40°C 20% to 80%
non-condensing
23°C
Non-Operational 0°C to +50°C 8% to 80%
non-condensing
27°C
Storage 1°C to +60°C 8% to 80%
non-condensing
29°C
Shipping -40°C to +60°C 5% to 100%
non-precipitating
29°C
Airflow System must be operated with low pressure rear exhaust installation
(Back pressure created by rack doors and obstacles not to exceed 5 pascals [0.5mm Water gauge])
Altitude, Operational 0 to 2133 m (0 to 7,000ft) Altitude, Non-Operational -305 to 12,192m (-1000 to 40,000ft) Shock, Operational Vertical axis 5g peak 1/2 sine, 10ms Shock, Non-Operational 30g 10ms 1/2 sine Vibration, Operational 0.21grms 5-500 Hz Random Vibration, Non-Operational 1.04grms 2-200 Hz Random Vibration, Relocation 0.3g 2-200 Hz sine Acoustics Sound Pressure Operating - Less than 58 dB LpA average
measured at the bystander positions.
(The 4 bystander positions are 1m horizontal and 1.5m off the floor positioned front, back, left and right. The unit under test will be measured on the floor)
Measured at 20°C
Orientation & Mounting 19" Rack mount (3EIA Units)
• Rack Rails To fit 800mm depth Racks compliant with IEC 297
• Rack Characteristics Back pressure not exceeding 5 pascals (0.5mm water gauge)
Safety & Approvals CE, UL, cUL
•EMC EN55022 (CISPR - A), FCC A
Drive support See drive carrier specification Attachment • 1 FCAL loop of 16 drives per SBD module
• Passive Backplane with 1 or 2 Loop Resiliency Circuit (SBD) Module.
• Host/Expansion Ports: FC-AL – 4 x SFP optical per SBD module
RS-1600/1602-FC-SBD User Guide
16
1.5.9 SBD Module Specification
FC-AL: Error Handling
Auto disk Port Bypass on:
• CRC error level exceeding 10 errors per 512 million frames persistently.
• Word error levels exceeded
BURST - more than 400 errors in a 4 second.period, 3 times consecutively.Long term- more than 20 errors in a30 minute period consecutively.
• Clock Delta greater than 200 ppm.
• Repeated insertion.
• Failure to insert within a minute.
For more details on the algorithms used and how to configure these settings please contact your customer service representative.
SES Reporting
Using vendor specific Extended Pages the following information can be gathered:
• Bypass reason, specific reason why the port is not inserted.
• Word errors
• CRC errors
• Clock delta
• Loop Up
• insert
•stalls
• utilization
Speed 1Gb/s or 2Gb/s FC-AL
• Creates connections to a single logical loop of 16 drives
Mounting Rear, single bays 3 and/or 4 (see Figure 1–3) Connectors • 4 x SFP connectors for Host/Expansion Ports, to accommodate the
following interconnects:
a optical (LC to LC cable), maximum length 500m b copper (100 ohm SFP patch cable) maximum length 1.5m, or c copper SFP, maximum length 10m.
• 1 x RS232 , 6 pin Mini-DIN (factory use only)
Power Dissipation 5A @ 3.3V, 1A @ 5V
Introduction
17
LED Functions
1.5.10 Drive Carrier Module Specification
Please contact your supplier for details of approved drives.
Important Operating RS-1600-FC-SBD or RS-1602-FC-SBD subsystems with non-approved drives may
invalidate the warranty.
1.5.11 SCSI Enclosure Services (SES) Support
The enclosure has a sophisticated self-monitoring and reporting function which conforms to ANSI SES specifications.This reports on such topics as:
Enclosure temperatureFan speedDrive conditionOperator panel status
Extensive detailed data on all internal ports of the SBD module is also provided via Vendor Specific Extended SES Pages.
For more information on the implementation of this function please request a copy of the SBD SES specification from your supplier.
LED Color Description Status Green
OFF
Flashing
All device ports GOOD @ 2Gb/s All device ports GOOD @ 1Gb/s Drives bypassed on module
SBD Module Fault Amber When ON this LED denotes that the SBD module is FAILED Host port 0
Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host Port 1 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host Port 2 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host port 3 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Module Dimensions • Height 29.1mm
• Width 106.55mm
•Depth
RS-1600: 207mmRS-1602: 251 mm
Weight • RS-1600: 0.88kg
• RS-1602: 0.98kg (1.0” 36Gb drive)
Operating Temperature 5° C to 40° C (when installed in an RS-1600/1602 system enclosure with
dual Power Supply/Cooling Modules)
Power Dissipation 17 Watts maximum
RS-1600/1602-FC-SBD User Guide
18
Getting Started
19
Chapter 2
Getting St arted
2.1 Introduction
In this chapter, you are shown how to install your RS-1600-FC-SBD or RS-1602-FC-SBD Enclosure and plug-in modules into an industry standard 19 inch rack cabinet.
Caution When connecting up the RS-1600-FC-SBD or RS-1602-FC-SBD subsystem, use only the power cords
supplied or cords which match the specification quoted in section 1.5.6.
2.2 Planning Your Installation
Before you begin installation you should become familiar with the configuration requirements of your RS­1600-FC-SBD or RS-1602-FC-SBD subsystem, detailed in
Figure 2–1. The correct positions of each of
the optional plug-in modules are shown in Figure 2–1. Please refer to sections 2.6 - 2.5 for details of SBD module configurations and installation.
Caution Dummy Carriers and Blank Modules MUST be fitted to ALL unused bays, there will be inadequate drive
cooling if any are left open.
Table 2–1 Enclosure Subsystem Configuration
Module Location
Drive Bays ALL drive bays must be fitted with either a drive carrier module or a dummy
carrier, no bays should be left completely empty.
Power Supply/Cooling Modules
Two Power Supply/Cooling modules must be fitted. Full power and cooling redundancy is provided while a faulty module is replaced. Install the Power Supply/Cooling modules in rear Bays 1 & 5.
Note: Rear bays are numbered from 1 to 5 commencing from the right
hand side) SBD Module Install in rear Bays 3 and 4 Ops Panel (integral part of chassis assembly) Installed in rear Bay 2
RS-1600/1602-FC-SBD User Guide
20
2.2.1 Enclosure Bay Numbering Convention
The enclosure bay numbering convention is shown in Figure 2–1. A Bay is defined as the space required to house a single 1.0" high 3.5 inch disk drive in its carrier module. e.g. a 1 x 4 bay module would take the space of 1 drive width by 4 drive bays high (in the rack mount configuration).
RS-1600-FC-SBD and RS-1602-FC-SBD subsystems are housed in a 4 x 4 enclosure, i.e. 4 bays wide by 4 bays high. The front bays are numbered 1 to 4 from left to right, viewed from the front. Bays are numbered from 1 (top row) to 4 (bottom row). Drive Carrier Module locations are identified from a matrix of the top and side numbers. The rear bays are numbered 1 to 5 from right to left, viewed from the rear
Important Drive carrier module must always be fitted in locations 1/1 (drive 0) and 4/4 (drive 15). This is the
minimum configuration required for the system to operate and provide SES Management Services.
Figure 2–1 Module locations
Getting Started
21
2.3 Enclosure Installation Procedures
Caution The RS-1600-FC-SBD and RS-1602-FC-SBD Enclosures with all component parts installed are too
heavy for easy installation into a Rack cabinet. The following procedures describe the installation of RS­1600-FC-SBD and RS-1602-FC-SBD enclosures and highlights any critical co-requisite requirements and good handling practices which we encourage you to follow so as to ensure that a successful installation is achieved in the easiest manner.
Warning Ensure that you have fitted and checked a suitable anti-static wrist or ankle strap and observe all
conventional ESD precautions when handling RS-1600-FC-SBD or RS-1602-FC-SBD modules and components. Avoid contact with Backplane components and module connectors, etc.
2.3.1 Pre-Requisites
The RS-1600-FC-SBD and RS-1602-FC-SBD Enclosures are designed for installation into an industry standard 19 inch cabinet capable of holding the unit.
• Minimum depth 500 mm from front flange to rear metalwork (excludes rear cabling).
• Weight: up to 37kg dependent upon configuration per enclosure.
• A minimum gap of 25mm (1inch) clearance between the rack cover and front of drawer; and 50mm (2 inches) rear clearance between rear of drawer and rear of rack is recommended in order to maintain the correct air flow around the enclosure.
• The rack should present a maximum back pressure of 5 pascals (0.5mm water gauge).
2.3.2 Rack Mounting Rail Kit
A set of mounting rails is available for use in 19 inch rack cabinets. These rails have been designed and tested to handle the maximum enclosure weight and to ensure that multiple RS-1602 enclosures may be installed without loss of space within the rack. Use of other mounting hardware may cause some loss of rack space.
The rack mounting rail kit also incorporates a rear hold down mechanism to ensure shock and vibration immunity.
Please contact your supplier to ensure suitab l e mo un t ra il s are ava i la b l e fo r the rack yo u are using.
2.3.2.1 Parts Check List
• Rack Mounting Rail Kit.
2.3.2.2 Installation Procedure
Please see detail drawings supplied with the rack mounting rail kit for assembly details.
RS-1600/1602-FC-SBD User Guide
22
2.3.3 Chassis Installation
2.3.3.1 Parts Check List
• Chassis (complete with Backplane and Ops Panel installed but excluding all plug-in modules).
• Rack mount front flange mounting screws (4 off).
2.3.3.2 Procedure
1 Check for damage.
2 Slide the chassis assembly onto the rack rails until the front flanges engage on the rack. Ensure the
chassis is centrally located.
3 If in doubt about correct orientation, the drive bays (at front) should have their black drive connectors
toward the bottom of each bay.
4 Screw the 4 front rack mount screws through the flanges and tighten.
5 Fit and tighten the rear hold down screws ensuring the enclosure is in tight contact to both the side and
top of the chassis to avoid any movement of the chassis in the rack.
Figure 2–2 Rack Mounting Rail Kit
Getting Started
23
2.4 Power Supply/Cooling Module Inst allation
Install in the rear of the enclosure in positions 1 and 5.
Warning Do not remove covers from the Power Supply/Cooling (PSU) module. Danger of electric shock
inside. Return the PSU to your supplier for repair.
2.4.1 Parts Check List
2 Power Supply/Cooling Modules of the following types:
Either:2 x AC 450W PSU
or 2 x -48V DC 450W PSU
Warning Do not mix Power Supply/Cooling modules of different types.
2.4.2 AC Power Supply/Cooling Module Procedure
Important PSU2 (RH rear bay) must be fitted “upside-down” as shown in Figure 2–1. If the cable strain relief
wire tab is upside down it must be inverted by squeezing together the two sides of the tab removing them from their mountings, inverting and then replacing them, as shown in
Figure 2–3.
1 Check for damage, especially to the rear connector on the supply.
Caution Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins
appear to be bent.
2 With the PSU handle in the open position (Figure 2–4), slide the module into the enclosure (Figure 2–5).
Important install the Power Supply/Cooling module in the right hand bay (Rear Bay 1) of the enclosure in an
“upside down* orientation.
3 Cam the module home by manually closing the PSU handle (Figure 2–6). A click should be heard as the
handle latches engage.
4 Connect the power supply cord to the power source and switch the power supply ON.
Figure 2–3 Inverting the Cable Strain Relief
RS-1600/1602-FC-SBD User Guide
24
Figure 2–4 AC Power Supply/Cooling Module - Handle in Open Position
Figure 2–5 Installing an AC Power Supply Cooling Module (1)
Getting Started
25
2.4.3 -48V DC Power Supply/Cooling Module Procedure
Important PSU2 (RH rear bay) must be fitted “upside-down” as shown in Figure 2–1. If the cable strain relief
wire tab is upside down it must be inverted by squeezing together the two sides of the tab removing them from their mounting s, inverting and then replacing them.
2.4.3.1 -48V DC PSU Safety Requirements
Voltage Rating
The marked rated voltage for the-48VDC Power Supply/Cooling (PSU) module is -40V DC to -60V DC. The equipment is intended to operate from a centralized dc supply system with a NOMINAL voltage of ­48V DC or -60V DC.The voltage from a nominal -48V DC system may vary, due to float charging or discharge conditions, from -40V DC to -60V DC.The voltage from a nominal -60V DC system may vary, due to float charging or discharge conditions, from -48V DC to -72V DC.
Caution If this equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Equipment Location
The rear of this Equipment (in particular the supply terminals and wiring to the terminals on the power supply) must only be located in a “RESTRICTED ACCESS LOCATION” where both of the following apply (Ref.UL60950):
• access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and
• access is through the use of a TOOL or lock and key, or other means of security and is controlled by the authority responsible for the location.
Figure 2–6 Installing an AC Power Supply Cooling Module (2)
RS-1600/1602-FC-SBD User Guide
26
Access restrictions are applicable where:
• The DC wiring to the terminals on the PSU are not enclosed.
• The PSU input terminals have exposed voltages that may exceed the 60 volt SELV limit during float charging of battery supply.
• The PSU input terminals have exposed hazardous energy levels, i.e. very high current capability.
Disconnect Device
The wiring installation must provide a disconnect device close to the product.
Wiring
Must be connected in accordance with the local and national wiring regulations.
Wire Temperature Rating
The supply wiring to the power supply terminal blocks must have a minimum temperature rating of 75ºC.
Terminal Block Screw Torque
The screws on the terminal block must be tightened to a torque of 2.4 Nm (21 in-lb.)
Circuit Protection
The building installation must provide overcurrent and short circuit protection in the non earthed supply conductor.
2.4.3.2 USA and Canadian Safety Requirements
Wiring Methods
Wiring method must be code compliant in the field. Wiring methods must be in accordance with the U.S. National Electric Code, Article 300.
Earthing
This equipment is designed to permit the connection of the earthed conductor (+) of the DC supply circuit to the earthing conductor at the equipment.
If this connection is made, all of the following conditions must be met (Ref. UL60950):
1 This equipment shall be connected directly to the DC supply system earthing electrode conductor
or to a bonding jumper from an earthing terminal bar or bus to which the DC supply system earthing electrode conductor is connected.
2 This equipment shall be located in the same immediate area (such as adjacent cabinets) as any
other equipment that has a connection between the earthed conductor of the same dc supply circuit and the earthing conductor, and also the point of earthing of the DC system. The DC system shall not be earthed elsewhere.
3 The DC supply source is to be located within the same premises as this equipment.
4 Switching or disconnecting devices shall not be in the earthed circuit conductor between the DC
source and the point of connection of the earthing electrode conductor.”
Getting Started
27
Protective Earth Conductor Size
The protective earth conductor size must be suitable for the maximum fault current that the installation can provide. U.S. National Electric Code, Article 250-122
Branch Circuit Protection
The PSU must be connected to a Branch circuit that is protected by a LISTED Branch Protector. Th e rating of the LISTED Branch Protector >= 125% of the product rating and the rating of the LISTED Branch Protector =< current rating of wire supplying the equipment. U.S. National Electric Code, Article 210-3, Article 240.
Minimum Wire Size
12 AWG minimum must be used for the input connections to the terminal block on the power supply.
Terminal Block Connections
The terminal block is suitable for Field Wiring and Factory Wiring.
2.4.3.3 Installation Procedure
Warning Installation of this Power Supply/Cooling module should only be performed by qualified
personnel.
1 Check for damage, especially to the rear connector on the Power Supply/Cooling module.
Caution Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins
appear to be bent.
2 With the PSU handle (Figure 2–7) in the open position, slide the module into the enclosure.
Important Install the PSU module in the right hand bay (Rear Bay 1) of the enclosure in an “upside down*
orientation.
3 Cam the module home by manually closing the PSU handle (see Figure 2–8). A click should be heard
as the handle latches engage (see Figure 2–9).
Figure 2–7 -48V Power Supply/Cooling Module - Handle in Open Position
RS-1600/1602-FC-SBD User Guide
28
4 Remove all supply power by turning off the supply at the disconnect device located near to the
equipment.
5 Remove the terminal block cover.
6 Connect the wires in accordance with the Wiring Instructions in section 2.4.3.4.
7 Replace the terminal block cover.
Figure 2–8 installing a -48V DC Power Supply/Cooling Module (1)
Figure 2–9 Installing a -48V DC Power Supply/Cooling Module (2)
Getting Started
29
8 Turn the supply power back on.
9 Switch on power at the PSU switch.
2.4.3.4 Wiring Instructions for -48V DC PSU
Warning The +48V and-48V terminals are not connected to chassis earth.
1 For installations with -48V earthed a shorting link mu st be added (see Figure 2–10).
2 For installations with a separate earth, connect the earth cable to the earth terminal (see Fi gure 2–11)
2.5 SBD Module Installation
2.5.1 Parts Check List
• 2 SBD Modules
2.5.2 Procedure
Important Fibre Channel Host and Expansion Conn ectors:
If fitted with Optical modules, the modules must be a UL (or other North American NRTL) RECOGNISED COMPONENT and the laser in the module must comply with Laser Class 1, US 21 CFR (J) and EN 60825-1.
If passive copper cables are connected, the cable must not have a connection to a common ground/earth point.
1 Check for damage especially to the interface connector, do not install if any pins are bent
2 The modules should be installed in rear bays 3 and 4 of the Enclosure (Figure 2–1).
3 With the latch in the open position (see Figure 2–12), slide the SBD module into the en cl o sure until the
latch engages automatically.
Figure 2–10 Shorting Link
Figure 2–11 Separate Earth
S
horting Link
E
arth Termina
l
RS-1600/1602-FC-SBD User Guide
30
.
4 Cam the module home by manually closing the latches (see Figure 2–13). A click should be heard as the
latch engages.
Figure 2–12 SBD Module Latch Operation
Figure 2–13 Installing an SBD Module
Getting Started
31
2.6 SBD Module Configurations
Important Please refer to section 2.9 for information on drive configurations.
2.6.1 Internal Loop Structures
RS-1600-FC-SBD and RS-1602-FC-SBD enclosures are configured with one internal loop of 16 drives.
2.7 FC-AL Interface
The SBD interface module provides quad FC-AL SFP interface connections.
The SBD module provides bi-directional connection between the Fibre Chann el host side interface and the drives.The drives will not be presented to the Host until they are configured and mapped by the controller.
Each SBD module can be connected to up to 4 Host Bus adaptors, as shown in Figure 2–14.
Note There are no external terminators required with Fibre Channel architecture and any drive may be hot
plugged during operation.
2.7.1 Connecting Multiple Enclosures
RS-1600-FC-SBD or RS-1602-FC-SBD enclosure expansion is achieved by connecting additional RS­1600-FC-SBD or RS-1602-FC-SBD enclosures, as appropriate, via SFP host/expansion ports of the SBD modules in the “master” enclosure, using SFP to SFP patch cables.
Any of the four SFPs on the SBD module can used as an IN or OUT connector.
A maximum of 2 FC interconnect can be used between each shelf.
Figure 2–14 Multiple Host Bus Adaptor Connections
RS-1600/1602-FC-SBD User Guide
32
Important Optical modules must be UL (or other North American NRTL) RECOGNISED COMPONENT and the
laser in the module must comply with Laser Class 1, US 21 CFR (J) and EN 60825-1.
Please contact your supplier for a list of qualified optical SFP components.
If passive copper cables are connected, the cable must not have a connection to a common ground/earth point.
Note A maximum of 6 expansion enclosures in Mode 0, or 5 expansion enclosures in Mode 1, can be attached
to RS-1600-FC-SBD or RS-1602-FC-SBD enclosures. A typical expansion configuration is shown in
Figure 2–15.
Setting the FC-AL Enclosure ID Range
Set each enclosure in a physical loop to a different range.
Drive bay 4/4 is set for immediate start, all other bays are delayed spin start (12 seconds x Module 8 of the SEL_ID) unless there are two active PSUs when they all start immediately.
Table 2–2 SBD Modul e LEDs
LED Color Description Host port 0
Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host Port 1 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host Port 2 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host port 3 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Status Green
OFF
Flashing
All device ports GOOD @ 2Gb/s All device ports GOOD @ 1Gb/s
Drives bypassed by module, see drive LED states.
SBD Module Fault Amber When ON this LED denotes that the SBD module is FAILED
Getting Started
33
Figure 2–15 Connecting Multiple Enclosures
RS-1600/1602-FC-SBD User Guide
34
2.8 Drive Enclosure Device Addressing
Each enclosure has 16 drives. The SEL_ID of each drive is determined by the device slot (0-15) in which it is installed and the address range setting, which is set by means of the Enclosure ID switch, additionally an Address Mode (Mode 0 or Mode 1) must be selected, please refer to Table 2–4.
The Mode selection is set on the Ops Panel (shown in Figure 1–7 on page 6) at the rear of the enclosure. The switch settings are as follows:
Notes 1 ON = switch to the Left, OFF = switch to the Right.
2 Switches 2 to 6 and 12 are Not Used.
3 Modes 2 and 3 are Not Used.
Table 2–3 Ops Panel Switch Functions (Default settings for RS-1600-FC-SBD or RS-1602-FC-SBD
SBD module usage at 2Gb/s)
Switch Number
Function Recommended Setting Definition
1 Loop Select,
Single (1x16)
On SBD operated on single loop of 16 drives
Mandatory 2 Not Used 3 Not Used 4 Not Used 5 & 6 Not Used 7 & 8 Drive Loop Speed
Select
Sw7 Sw8
On Off Force 2Gb/s Off Off Force 1Gb/s
9 & 10 Drive Addressing
Mode Selection
Sw9 Sw10
On On Mode 0 Off On Mode 1
11 SOFT SELECT On Select functions using the hardware
switches 12 Not Used
Getting Started
35
Note * SES drives. There must be a drive present in Bay 1/1 or 4/4 to enable SES communications to operate.
Note Drives are numbered row/column.
2.8.1 Drive Start
*SES drives: Drive bay set for immediate start, all other bays are delayed spin start (12 seconds x Module 8 of the SEL_ID) unless there are two active PSUs when they all start immediately.
With only one active PSU the enclosure will take approximately 96 seconds to start all drives from Power ON.
Table 2–4: Enclosure Device Settings
Drive Slot
Enclosure ID Switch
t 0* 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15*
Mode 1
0* 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
1 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 2 24 25 2 6 27 28 29 30 31 32 33 34 35 36 37 38 39 3 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 4 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 5 84 85 86 87 88 89 90 91 92 93 94 95 96 97 989 99
6-14 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119
Mode 0
0 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 1 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35
7 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115
Table 2–5 Drive Slot Arrangement: Enclosure Front View
Column/row 1/# 2/# 3/# 4/#
#/1 Drive 0* Drive 1 Drive 2 Drive 3 #/2 Drive 4 Drive 5 Drive 6 Drive 7 #/3 Drive 8 Drive 9 Drive 10 Drive 11 #/4 Drive 12 Drive 13 Drive 14 Drive 15*
RS-1600/1602-FC-SBD User Guide
36
2.9 Drive Carrier Configuration
2.9.1 Planning and Configuring Your Installation
2.9.1.1 System Configuration
Important Before you begin installation you should become familiar with the configuration requirements of
your RS-1600-FC-SBD or RS-1602-FC-SBD subsystem. Please refer to Section 2.2 for information on your overall system configurations.
There must be a drive present in Bay 1/1 or 4/4 to enable SES Communications to operate. Installing drives in both of these bays will provide redundant SES communication paths.
When planning your system configuration, please remember that:
• All RS-1600-FC-SBD and RS-1602-FC-SBD enclosure drive bays must be filled with either a drive carrier or front dummy fascia, no bays should be left completely empty.
2.9.1.2 Drive Configuration
Important After you have installed the drive carrier modules in yo ur RS-1600-FC-SBD or RS-1602-FC-SBD
enclosure, please refer to Section 2.6 for configuration information relevant to the SBD module you are installing.
2.10 Drive Carrier Installation
2.10.1 Parts Check List
• Drive Carrier module, or
• Dummy Carrier module
2.10.2 Procedure
1 Release the carrier handle, by pressing the latch in the handle towards the right and insert the carrier into
the enclosure.
Important For a Rack Mounted System: Ensure that the carrier is orientated so tha t the drive is uppermost
and the handle opens from the left (Figure 2–16).
For a Tower System: Ensure that the carrier is orientated so that the carrier lock position is uppermost and the handle opens from the top (
Figure 2–17).
Getting Started
37
2 Slide the carrier, gently, all the way into the enclosure until it is stopped by the camming lever on the right
of the carrier (
Figure 2–18)
3 Cam the carrier home - the camming foot on the base of the carrier will engage into a slot in the enclosure.
Continue to push firmly until the handle fully engages. A click should be heard as the latch engages and holds the handle closed (
Figure 2–19).
Note Ensure that the handle always opens from the left.
Figure 2–16 RS-1602-FC-SBD Drive Carrier (example shown Open for Rack System)
Figure 2–17 RS-1600-FC-SBD Drive Carrier (example shown Open for T ower System)
RS-1600/1602-FC-SBD User Guide
38
Note Removal is the reverse of this procedure (press on the latch to release the handle).
Figure 2–18 Installing a Drive Carrier Module (2)
Figure 2–19 Installing a Drive Carrier Module (3)
Getting Started
39
2.10.3 Dummy Carrier Modules
Any unused drive bays must be fitted with a dummy carrier module.
2.10.4 Engaging the Anti-tamper Locks
The anti-tamper locks are fitted in the drive carrier handles and are accessed through the small cutout in the latch section of the handle.
Drives are supplied with the locks set in the locked position.
2.10.4.1 Activating the Locks
1 Carefully insert the lock key provided into the cutout in the handle.
2 Locate the key into its socket.
3 Rotate the key in a clockwise direction until the indicator is visible in the aperture beside the key.
4 Remove the key.
De-activation is the reverse of this procedure, that is:
• Rotate the key in an anti-clockwise direction until the indicator is no longer visible in the aperture beside the key.
Note A drive carrier cannot be installed if its anti-tamper lock is activated outside the Enclosure.
2.11 Power Cord Connection
2.11.1 Parts Check List
• Power cord to requisite local standards
Figure 2–20 Activating the Anti-tamper Lock
RS-1600/1602-FC-SBD User Guide
40
2.11.2 Procedure
1 Attach the power cord to the Power Supply/Cooling Modules,
2 Attach the power cord to the in-line IEC connector in this cord.
Caution These power splitting cables are provided so that the system is operated from a SINGLE power source
thus providing a single point of disconnect.
3 Switch on each Power Supply/Cooling Module.
4 A POWER LED on the Ops Panel indicates whether AC power is present.
Caution The power connections must always be disconnected prior to removal of the Power Supply/Cooling
module from the enclosure.
2.12 Grounding Checks
Perform these checks to ensure that a safe grounding system is provided.
• If a rack distribution system is being used.
Ensure power is removed from the rack. Connect the RS-1600-FC-SBD or RS-1602-FC-SBD power cord to the rack distribution and the
enclosure.
• If a direct connection is made with the RS-1600-FC-SBD or RS-1602-FC-SBD power cord, ensure that it is connected to the enclosure.
Warning Some electrical circuits could be damaged if external signal cables or power control cables are
present during the grounding checks.
• Check for continuity between the earth pin of the IEC 320 connector on one of the Power Supply/ Cooling modules and any exposed metal surface of the RS-1600-F C-SBD or RS-1602-FC-SBD enclosure.
Operation
41
Chapter 3
Operation
3.1 Before You Begin
Before powering up the enclosure please ensure that all the modules are firmly seated in their correct bays.
3.2 Power On
Caution Do not operate this equipment until the ambient temperature is within the specified operating range. If the
drives have been recently installed ensure they have had time to acclima tize before operating them.
Note Please refer to Section 3.3 for details of the Ops Panel LEDs and related fault conditions.
Follow the procedure below to Pow e r On th e en cl o s ure.
1 Apply AC power to the enclosure. Turn the Power Supply modules to ON.
2 On the Ops Panel, the Audible Alarm beeps once, all LEDs flash for 7 seconds then the Alarm double
beeps.
3 All LEDs on the Ops Panel should be lit (Green) when the enclosure power is activated (and the disk drive
motors should start).
Note All LEDs on the Ops Panel should be lit Green at power up to indicate that the system is functioning
correctly. If any show Amber then a problem exists and the procedure in
Chapter 4 should be followed.
Important If AC power is lost for any reason, on restoration of power the enclosure will re-start
automatically.
RS-1600/1602-FC-SBD User Guide
42
3.2.1 Power Supply/Cooling Module LEDs
The Power Supply/Cooling module incorporates 4 LEDs, located below the On/Off switch and shown in
Table 3–1.
• Under Normal conditions the LEDs should all be illuminated constant GREEN
• If a problem is detected the color of the relevant LED will change to AMBER.
3.3 Ops Panel LEDs
The Ops Panel LEDs status conditions are defined in Table 3–2 and the LEDs are illustrated in Figure 3–1.
Table 3–1 PSU LEDs
AC PSU -48V DC PSU
PSU Good Green PSU Good Green AC input Fail Amber Battery Fail Amber Fan Fault Amber Fan Fault Amber DC Output Fail Amber DC Output Fail Amber
Figure 3–1 Ops Panel LEDs and Switches
Operation
43
Important Please refer to Table 4–2 on page 48 for details of the Ops Panel LED fault indications.
Chapter 4 on page 45 provides more information on ., ”Troubleshooting and Problem Solving”.
3.4 St arting the Drives
Unless otherwise selected during installation, all drives in the enclosure should automatica lly start their motors. If this has not occurred one of the following conditions may exist:
• There may be a power problem (an alarm and power fault indication would normally be active).
• if there is only one Power Supply/Cooling Module present, the drive motors will spin up in a delayed sequence.
3.4.1 Disk Drives LEDs
Each drive carrier incorporates two in di ca tors, an upper (GREEN) and lower (AMBER).
• In normal operation the Green LED will be ON and will flicker as the drive operates.
• The Amber LED will be OFF In normal operation. It will only be ON if there is a drive fault.
3.5 Power Down
To power the Enclosure down,
either
• Switch Off the Power Supply/Cooling modules installed in the Enclosure. or
• Remove AC power at the power source
Table 3–2 Ops Panel LED States
Ops Panel LEDs Other Associated
LEDs or Alarm
State Description
Power
(Green)
PSU/
Cooling/
Temp
(Amber)
System
(Amber)
Address
Mode Error
(Amber)
FC
Loop
Speed
(Green)
Hub
Mode
Selected
(Green)
On On On On On On single beep, then
double beep
Ops Panel power On (5s) test state
On Off Off Off Off Off Power On, all functions good On Off Off Off On Off 2Gb/s Drive loop speed selected On Off Off Off Off On RAID ONLY
Host side Hub mode enabled
RS-1600/1602-FC-SBD User Guide
44
Troubleshooting
45
Chapter 4
T roubleshooting and Problem Solving
4.1 Overview
RS-1600-FC-SBD and RS-1602-FC-SBD Enclosures include a processor and associated monitoring and control logic to enable them to diagnose problems within the enclosure’s power, cooling and drive systems.
The Enclosure Services Processor is housed along with the Ops Panel in the rear of the enclosure.
The sensors for power and cooling conditions are housed within the Power Supply/Cooling modules. There is independent monitoring for each unit.
If a fault is indicated on the Ops Panel, please refer to Table 4–2.
4.1.1 Initial Start-up Problems
4.1.1.1 Faulty Cords
First check that you have wired up the subsystem correctly. Then, if:
• cords are missing or damaged
• plugs are incorrect
• cords are too short
Call your supplier for a replacement.
4.1.1.2 Alarm Sounds On Power Up
Please refer to Section 4.3.
4.1.1.3 Green “Signal Good” LED on SBD Module Not Lit
Check that the Rx and Tx cables have not been inverted during installation.
RS-1600/1602-FC-SBD User Guide
46
4.1.1.4 Computer Doesn’t Recognize the RS-1600-FC-SBD or RS-1602-FC-SBD Subsystem
1 Check that the FC-AL interface cables from the RS-1600-FC-SBD or RS-1602-FC-SBD enclosure to the
host computer are fitted correctly.
2 Check the Drive Select ID settings on your RS-1600-FC-SBD or RS-1602-FC-SBD subsystem and on
your system host.
3 Check that the LEDs on all installed drive carrier modules are illuminated Green. Note that the drive LEDs
will not be lit during drive spinup.
4 Check that all drive carrier modules have been correctly install ed.
5 Check that there is a valid FC_AL signal present at the SBD connector (see section 2.6.1.) If there is no
signal present check that the cable has not been inverted during installation.
6 Check the SBD module setup as follows:
Check that the SBD module has been correctly installed and all external links and cables are
securely fitted.
Check the maximum cable length has not been exceeded.
4.2 LEDs
Green LEDs are always used for good or positive indication, flashing Green/Amber if non-critical conditions exist. Amber LEDs indicate there is a critical fault present within the module.
4.2.1 Power Supply/Cooling Module LEDs
The Power Supply Cooling LEDs are shown in Table 4–1.
• Under Normal conditions the LEDs should all be illuminated constant GREEN
• If a problem is detected the color of the relevant LED will change to AMBER.
Table 4–1 PSU LEDs
AC PSU -48V DC PSU
PSU Good Green PSU Good Green AC input Fail Amber Battery Fail Amber Fan Fault Amber Fan Fault Amber DC Output Fail Amber DC Output Fail Amber
Troubleshooting
47
4.2.2 Ops Panel LEDs
The Ops Panel displays the aggregated status of all the modules. The Ops Panel LEDs are shown in
Figure 4–1 and defined in Table 4–2. For details on how to remove and replace a plug-in module see
Section 4.8.
Note The Ops Panel is supplied as an integral part of the Enclosure core product and is not user replaceable.
Figure 4–1 Ops Panel
RS-1600/1602-FC-SBD User Guide
48
Note “x” = no bearing on these states
Table 4–2 Ops Panel LED States
Ops Panel LEDs Other Associated
LEDs or Alarm
State Description
Power
(Green)
PSU/
Cooling/
Temp
(Amber)
System
(Amber)
Address
Mode Error
(Amber)
FC
Loop
Speed
(Green)
Hub
Mode
Selected
(Green)
On Off Off Off Off Off HDD green LEDs
OFF
5V Aux present, overall power failed
On On On On On On single beep, then
double beep
Ops Panel power On (5s) test state
On Off Off Off x x HDD green LEDs ONPower On, all functions good
On On Off x x x PSU LEDs or Fan
LEDs
Any PSU fault or Fan fault
On On Flash x x x Over or Under temperature On Off On x x x ESI LED on SBD ESI processor module A Failed On Off On x x x ESI LED on SBD ESI processor module B Failed On Off On x x x None • Unknown (invalid or mixed)
SBD module type installed, or
• I2C Bus Failure (inter ESI processor), or
• Backplane autostart watchdog failed.
On Flashing Flashing x x x PSU Removed PSU removed and System power
redundancy check option set. No indication if option not set.
On Off Flashing x x x SI alarm No SES Drive s fitted On Flashing On x x x Intermittent
audible alarm
Ops to ESI Communications failed
On x x Flashing x x Invalid address mode setting
(change thumb wheel to valid ranges)
On x x x On x 2Gb/s Drive loop speed selected On x x x x On RAID ONLY
Host side Hub mode enabled
Troubleshooting
49
4.2.3 SBD Module LEDs
The SBD module incorporates the following LED indicators: For details on how to remove and replace an SBD module see Section
4.8.3.
4.2.4 Drive Carrier LEDs
Please refer to Table 4–4 on page 50.
4.3 Audible Alarm
The Ops Panel also includes an Audible Alarm which indicates when a fault state is present. The following conditions will activate the Audible Alarm:
• Fan Fault
• Voltage out of range
• Over temperature
• Thermal overrun
• System fault
4.3.1 Audible Alarm Mute
When the Audible Alarm sounds, it may be muted by pressing the Alarm Mute push-button. Automatic muting will take place after two minutes if the mute switch is not manually operated. The Alarm Mute push-button is located above the indicators on the Ops Panel (see Figure 4–1).
When the alarm is muted it will continue to sound with short intermittent bleeps to indicate that a problem still exists, It will be silenced when all problems are cleared. (See also Thermal Shutdown states, Section
4.5.5).
Table 4–3 SBD Module LEDs
LED Color Description Host port 0
Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host Port 1 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host Port 2 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Host port 3 Signal Good
Green When ON this LED denotes that incoming FC signal is GOOD.
Status Green
OFF
Flashing
All device ports GOOD @ 2Gb/s All device ports GOOD @ 1Gb/s
Drives bypassed by module, see drive LED states.
SBD Module Fault Amber When ON this LED denotes that the SBD module is FAILED
RS-1600/1602-FC-SBD User Guide
50
4.3.1.1 LED Test Mode
The Alarm Mute push-button can also be used to test the LEDs on the Ops Panel. When the Mute push­button is held, all LEDs will be illuminated if there are no faults present.
4.4 Drive Carrier Module Faults
Disk drive status is monitored by a green LED and an amber LED mounted on the front of each Drive Carrier Module (see
Figure 4–2), providing the following indications:
Drive activity - LED may be off for a length of time during power up.
4.4.1 Dummy Carrier Modules
Dummy Carrier modules must be fitted to all unused drive bays to maintain a balanced air flow.
4.4.2 Auto Start Failure
Unless otherwise selected at installation time, all drives in the enclosure should automatically start their motors after power is applied. If this has not occurred there is a power problem (An alarm and power fault indication would normally be active).
Note The SYSTEM LED will flash Green/Amber.
Table 4–4 Drive Carrier LED Functions
State Green Amber
No drive fitted Off Off Drive Power ON On Off Drive Activity On/Blink off Off Drive Fault On On Drive bypassed by SBD On Flashing
Figure 4–2 Drive Carrier LEDs
Troubleshooting
51
4.5 Troubleshooting
The following sections describe problems, with possible solutions, which can occur with your RS-1600­FC-SBD or RS-1602-FC-SBD subsystem
4.5.1 System Faults
Note See also Section 4.5.5.
4.5.2 Power Supply/Cooling Faults
Symptom Cause Action
1 The FAULT LED will
illuminate AMBER on the SBD module
2 Audible Alarm sound
The ESI processor has detected an internal fault (e.g. failure of an internal communications path)
1 Check for other AMBER LED indications on the
Power Supply/Cooling modules. If there is a PSU error present there may be a communications problem with that Power Supply/Cooling module. Remove and then re-fit the module, if the problem persists then change the module.
2 Check for other AMBER LED indications on the
drives carriers. If none are evident then there may either be an ESI processor problem or a Backplane problem.
3 If possible check SES page 2, for any indicate
(status = 001).
4 Change the Ops Panel module (see 4.8.2).
Symptom Cause Action
1 Ops Panel FAULT
LED AMBER
2 An AMBER LED on
one or more Power Supply/Cooling Modules.
3 Audible Alarm
sounding.
1 Any power
fault.
2 A fan failure.
3 A thermal
condition which could cause PSU overheating.
1 Check Power On/Off Switch on rear of Power
Supply/Cooling module is switched ON.
2 Check AC power connections to Power Supply/
Cooling module are live.
3 Disconnect the Power Supply/Cooling module
from AC power and remove the module from the system, Re-install: if problem persists, replace Power Supply/Cooling Module.
4 Reduce the ambient temperature.
RS-1600/1602-FC-SBD User Guide
52
4.5.3 Thermal Control
RS-1600-FC-SBD and RS-1602-FC-SBD Enclosures use extensive thermal monitoring and take a number of actions to ensure component temperatures are kept low and also to minimize acoustic noise.Air flow is from front to rear of the enclosure.
Symptom Cause Action
If the ambient air is cool (below 25 °C) and the fans are observed to increase in speed then some restriction on airflow may be causing additional internal temperature rise.
Note: This is not a fault condition.
The first stage in the thermal control process is for the fans to automatically increase in speed when a thermal threshold is reached. This may be caused by higher ambient temperatures in the local environment and may be perfectly normal.
Note: This threshold changes according to the number of drives and power supplies fitted.
1 Check the installation for any airflow
restrictions at either the front or rear of the enclosure. A minimum gap of 25mm at the front and 50mm at the rear is recommended.
2 Check for restrictions due to dust
build-up, clean as appropriate.
3 Check for excessive re-circulation of
heated air from rear to the front, Use in a fully enclosed rack installation is not recommended.
4 Check that all Blank modules are in
place.
5 Reduce the ambient temperature.
Troubleshooting
53
4.5.4 Thermal Alarm
Symptom Cause Action
1 Ops Panel FAULT
LED AMBER.
2 An AMBER LED on
one or more Power Supply/Cooling Module.
3 Audible Alarm
Sounding.
4 Air temperature
exiting PSU above 55°C.
If the internal temperature measured in the airflow through the enclosure exceeds a pre­set threshold a thermal alarm will sound.
1 Check local ambient environment
temperature is below the upper 40°C specification.
2 Check the installation for any airflow
restrictions at either the front or rear of the enclosure. A minimum gap of 25mm at the front and 50mm at the rear is recommended.
3 Check for restrictions due to dust
build-up, clean as appropriate.
4 Check for excessive re-circulation of
heated air from rear to the front, use in a fully enclosed rack installation is not recommended.
5 If possible shutdown the enclosure
and investigate the problem before continuing.
RS-1600/1602-FC-SBD User Guide
54
4.5.5 Thermal Warnings
4.6 Dealing with Hardware Faults
Ensure that you have obtained a replacement module of the same type before removing any faulty module.
Warning If your RS-1600-FC-SBD or RS-1602-FC-SBD subsystem is powered up and you remove any
module, replace it immediately. If the subsystem is used with modules or module blanks missing for more than a few minutes, the Enclosure can overheat, causing power failure and data loss. Such use will invalidate the warranty.
• Replace a faulty drive with a drive of the same type and capacity.
• All drive bays must be fitted with a Drive Carrier module or a dummy carrier module in order to maintain a balanced air flow.
• All the supplied plug-in power supply units, electronics modules and blank modules must be in place for the air to flow correctly around the cabinet.
4.7 Continuous Operation During Replacement
Depending on how the subsystem is set up, if a disk unit fails, it can normally be replaced without interrupting the use of the system.
In addition, each enclosure contains two Power Supply/Cooling modules, either of which can maintain power and cooling to the subsystem while the other is replaced.
Symptom Cause Action
1 ALL AMBER LEDs
on the Ops Panel and on ALL drive bays illuminated flash.
2 Audible Alarm
sounds almost continuously and cannot be muted.
At a higher threshold than the Thermal Alarm (this should already have been activated).
OR - All fans have failed.
OR - Only 1 fan operating and the internal temperature is 40° C or above.
1 Check for airflow restrictions.
2 Check Power Supply/Cooling
module faults.
3 Check for excessive local
temperatures.
4 Switch Off immediately.
Troubleshooting
55
4.8 Replacing a Module
Warning Whenever replacing a module NEVER leave an EMPTY space in the rear of the enclosure, obtain
a replacement before removing the problem part.
Please refer to Chapter 2 , ”Getting Started” for information on the initial installation of the plug-in modules in the RS-1600-FC-SBD or RS-1602-FC-SBD enclosure.
Warning Observe all conventional ESD precautions when hand ling RS-1600-FC-SBD or RS-1602-FC-SBD
modules and components. Avoid contact with Backplane components and mo dule connectors, etc.
4.8.1 Power Supply/Cooling Modules
Warning Do not remove covers from the Power Supply/Cooling (PSU) module. Danger of electric shock
inside. Return the PSU to your supplier for repair.
4.8.1.1 Removing an AC Power Supply/Cooling Module
Warning Do not remove the faulty Power Supply /Cooling module unless you have a replacement unit of the
correct type ready for insertion.
If a power supply unit or its fan is faulty, you must replace the whole Power Supply/Cooling module.
As there should always be two power supply units installed, you can continue working while replacing the faulty module.
1 Make sure you identify the faulty Power Supply/Cooling module correctly, from the two modules installed.
2 Switch off and disconnect the power supply cord.
3 Squeeze the two latches on the PSU handle together (Figure 4–3) and open the handle to cam the PSU
out of the enclosure (Figure 4–4).
4 Grip the handle and withdraw the PSU (Figure 4–5).
4.8.1.2 Inserting the Module
1 Check for damage, especially to the rear connector on the PSU.
Caution Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins
appear to be bent.
2 With the PSU handle (Figure 4–4) in the open position, slide the module into the enclosure.
Important install the Power Supply/Cooling module in the right hand bay (Rear Bay 1) of the enclosure in an
“upside down* orientation.
3 Cam the module home by manually closing the PSU handle (see Figure 4–5). A click should be heard as
the handle latches engage (see Figure 4–3 ).
4 Connect the power supply cord to the power source and switch the power supply ON.
Note The alarm will sound until the new Power Supply/Cooling module is opera ting correctly.
RS-1600/1602-FC-SBD User Guide
56
Figure 4–3 Removing/Inserting an AC Power Supply/Cooling Module (1)
Figure 4–4 Removing/Inserting an AC Power Supply/Cooling Module (2)
Troubleshooting
57
4.8.1.3 Removing a -48V DC Power Supply/Cooling Module
Warning Do not remove the faulty Power Supply/Cooling (PSU) module unless you have a replacement unit
of the correct type ready for insertion.
Safety Requirements
Warning Please refer to 2.4.3.1, ”-48V DC PSU Safety Requirements”, on page 25 before proceeding with
the following Removal procedures.
1 Switch off power at the PSU switch.
2 Remove all supply power by turning off the supply at the disconnect device located near to the equipment.
3 Remove the terminal block cover.
4 Disconnect the wires.
5 Replace the terminal block cover.
6 Squeeze the two latches on the PSU handle together and open the handle (see Figure 4–6) to cam the
Power Supply/Cooling module out of the en cl o s ure.
7 Grip the handle and withdraw the module.(see Figure 4–8 ).
Figure 4–5 Removing/Inserting an AC Power Supply/Cooling Module (3)
RS-1600/1602-FC-SBD User Guide
58
Figure 4–6 Removing/Inserting a -48V DC Power Supply/Cooling Module (1)
Figure 4–7 Removing/Inserting a -48V DC Power Supply/Cooling Module (2)
Troubleshooting
59
4.8.1.4 Installing a -48V DC Power Supply/Cooling Module
Warning Installation of this PSU module should only be performed by qualified personnel.
Safety Requirements
Warning Please refer to 2.4.3.1, ”-48V DC PSU Safety Requirements”, on page 25 before proceeding with
the following Installation procedures.
1 Check for damage, especially to the rear connector on the Power Supply/Cooling module.
Caution Handle the module carefully and avoid damaging the connector pins. Do not install the module if any pins
appear to be bent.
2 With the PSU handle (Figure 4–7) in the open position, slide the module into the enclosure.
Important install the Power Supply/Cooling module in the right hand bay (Rear Bay 1) of the enclosure in an
“upside down” orientation.
3 Cam the module home by manually closing the PSU handle (see Figure 4–8). A click should be heard as
the handle latches engage (see Figure 4–6 0.
4 Remove all supply power by turning off the supply at the disconnect d evice located near to the
equipment.
5 Remove the terminal block cover.
Figure 4–8 Removing/Inserting a -48V DC Power Supply/Cooling Modu le (3)
RS-1600/1602-FC-SBD User Guide
60
6 Connect the wires in accordance with the Wiring Instructions in section 4.8.1.5.
7 Replace the terminal block cover.
8 Turn the supply power back on.
9 Switch on power at the PSU switch.
4.8.1.5 Wiring Instructions for -48V DC PS U
Warning The +48V and-48V terminals are not connected to chassis earth.
1 For installations with +48V earthed a shorting link must be added (see Figure 4–9).
2 For installations with a separate earth, connect the earth cable to the earth terminal (see Figure 4–10)
.
4.8.2 Ops Panel
The Ops Panel is an integral part of the enclosure chassis assembly and can only be replaced by trained personnel.
Figure 4–9 Shorting Link
Shorting Link
Figure 4–10 Separate Earth
E
arth Termina
l
Troubleshooting
61
4.8.3 SBD Module
Please refer to section 2.5, ”SBD Module Installation”, on page 29 for full information on installing the SBD module.
4.8.3.1 Removing the Module
Warning Do not remove this module unless a replacement can be immediately added. The system must not
be run without all units in place.
1 Using two hands, grasp each latch between the thumb and forefinger of each hand. Squeeze thumb and
forefinger together to release the latch. Pull the latches forward to cam the module out of the enclosure (Figure 4–13).
2 Grip the latch handles and withdraw the modul e (Figure 4–11).
Figure 4–11 Removing a SBD Module (1)
RS-1600/1602-FC-SBD User Guide
62
4.8.3.2 Inserting the Module
1 With the latch in the open position, slide the SBD module into the enclosure until the latch engages
automatically.
2 Cam the module home by manually closing the latches (see Figure 4–13).
3 A click should be heard as the latch engages.
Figure 4–12 Removing a SBD Module (2)
Figure 4–13 SBD Module Latch Operation
Troubleshooting
63
4.8.4 Drive Carrier Module
Please see section 2.10, ”Drive Carrier Installation”, on page 36 for information on the initial installation of the plug-in modules in the RS-1600-FC-SBD or RS-1602-F C-SBD enclosure.
Warning Observe all conventional ESD precautions when hand ling RS-1600-FC-SBD or RS-1602-FC-SBD
modules and components. Avoid contact with backplane components and modu le connectors, etc.
4.8.4.1 Removal and Replacement
Caution Drive spin down
Damage can occur to a drive if it is removed while still spinning, we recommend that you perform All steps of the following procedure to ensure that the drive has stopped prior to removal:
1 Release the carrier handle, by pressing the latch in the handle towards the right
Note The anti-tamper lock must be off.
2 Gently withdraw the Drive Carrier Module approximately 1 inch (25mm) and wait 30 seconds.
3 Withdraw the module from the drive bay and fit a replacement module in accordance with the instructions
in Section
2.10, ”Drive Carrier Installation”.
4.9 Sp are Part s and Ancillary Items
The following replaceable parts are available for RS-1600-FC-SBD and RS-1602-FC-SBD subsystems:
• Chassis including Backplane and integrated Ops Panel (RS-1600 or RS-1602 series as appropriate)
• AC Power Supply/Cooling Module
• -48V DC Power Supply/Cooling Module
• Drive Carrier Module (RS-1600 or RS-1602 as appropriate)
• SBD Module
• External FC-AL Interface Cables
• Cables:
LC - LC optical cables (500m length)SFP - SFP copper patch cable (1.5m length)SFP - SFP copper cable (10m length)RS232 cableLAN cable
• SFP module, optical
• SFP module, copper
• 19 inch rack mounting rail kit
• Dummy Carrier Module
• Bifurcated power cords
• (Country specific) power cords
• Keys for Drive Carrier modules.
• All documentation
RS-1600/1602-FC-SBD User Guide
64
Glossary
65
Glossary
In glossary definitions, italics are used for items defined elsewhere in the glossary and bold is used for the items shown in brackets after the main heading of the entry.
ASCII American Standard Code for Information Interchange. A 7-bit binary code (0's, 1's) used to represent letters, numbers, and special characters such as $,!, and /. Supported by almost every computer and terminal manufacturer.
Attribute Setting that controls access to a specific file. Often used to protect important files (such as the Registry files) from accidental change or deletion. Set using the ATTRIB command in MS-DOS.
Backplane A printed circuit board incorporated in the chassis assembly to provide logic level signal, and low voltage power distribution paths.
Bay The slot that a unit or media device fits into.
Byte A group of binary digits stored and operated upon as a unit. A byte may have a coded value equal
to a character in the ASCII code (letters, numbers), or have some other value meaningful to the computer. In user documentation, the term usually refers to 8-bit units or characters. 1 kilobyte (K) is equal to 1,024 bytes or characters; 64K indicates 65,536 bytes or characters.
Cable Throughout this RS-1600-FC-SBD and RS-1602-FC-SBD user guide this term is used in accordance with the preferred US context of: “an insulated flexible electric wire used for the transmission of data signals between computer equipment.”
Note: Cable is UK preferred terminology for either a power cord or a data cable.
Character A representation, coded in binary digits, of a letter, number, or other symbol.
Characters Per Second A data transfer rate generally estimated from the bit rate and the character
length. For example, at 2400 bps, 8-bit characters with Start and Stop bits (for a total of ten bits per character) will be transmitted at a rate of approximately 240 characters per second (cps).
Chassis A sheet metal enclosure incorporating a Backplane Printe d Circuit Board and module runner system. The chassis contains a number of 'Bays', each of which can accommodate a plug in module. There are sixteen drive carrier bays at the front and five bays at the rear which house two power supply/ cooling modules, two SBD modules and also the Ops Panel.
Configure To set up a hardware device and its accompanying software.
Data Communications A type of communications in which computers and terminals are able to
exchange data over an electronic medium.
Disk (drive, carrier, module) A FC disk drive mounted in a carrier. You can have up to sixteen disk drive carrier modules in each RS-1600-FC-SBD or RS-1602-FC-SBD enclosure.
Enclosure The chassis assembly which houses the plug-in modules that make up an RS-1600-FC­SBD or RS-1602-FC-SBD storage subsystem.
ESI/Ops module A unit used to monitor and control all elements of the Enclosure. The ESI/Operators (Ops) panel is supplied as an integral part of the RS-1600/1602 series Enclosure core products
RS-1600/1602-FC-SBD User Guide
66
Hot plugging A device with the capability of being connected to a subsystem without interrupting the power supplies to that subsystem.
Hot swap Hot swapping is the term used for manually swapping a failed disk unit with a replacement while an RS-1600-FC-SBD or RS-1602-FC-SBD subsystem is in normal use.
Hz (Hertz) a frequency measurement unit used internationally to indicate cycles per second.
Initialize To prepare a hardware device for use.
LED Light Emitting Diode. A small light displayed on the cabinet, disk units and power supply units.
LRC I/O module (SBD module) A plug-in module providing FC-AL channel external cable interface
with 16 FC drives, containing an integrated 20-port Fibre Channel Switch and optionally a Target SES interface device. These produce an SBOD (Switched Bunch of Discs) module with1Gb/2Gb external operating speed, known as SBD modules. The SBD module provides enhanced diagnostic status for FC ports and improved performance through its switching function.
Module (power supply, drive, SBD) A module is a power supply, disk drive or electronics unit held in a carrier that plugs into a bay inside the enclosure. An RS-1600-FC-SBD or RS-1602-FC-SBD enclosure can contain sixteen drive modules, two power supply/cooling modules and two SBD (I/O) modules.
Operating system The software running the host computer. For example, on PCs it is often Windows 2000, Windows NT or Windows XP and on Hewlett-Packard machines it could be HP-UX.
Parallel Transmission The transfer of data characters using parallel electrical paths for each bit of the character, for example, 8 paths for 8-bit characters. Data is stored in computers in parallel form, but may be converted to serial form for certain operations. See Serial Transmission.
Power Cord Throughout this RS-1600/1602-FC-SBD user guide this term is used in accordance with the preferred US context of: “an insulated flexible electric wire fitted with connectors at each end and used for the transmission of electrical power to computer equipment.
Protocol A system of rules and procedures governing communications between two or more devices. Protocols vary, but communicating devices must follow the same protocol in order to exchange data. The format of the data, readiness to receive or send, error detection and error correction are some of the operations that may be defined in protocols.
Redundant Not essential.
Serial Transmission The transfer of data characters one bit at a time, sequentially, using a single
electrical path. See Parallel Transmission.
.
Index
67
Index
numerics
-48V DC PSU x, 2, 4, 5, 23
a
AC PSU 2, 4, 23 Alarm Mute push-button 12, 49, 50 anti-static wrist or ankle strap 21 anti-tamper lock 11, 39, 63 Audible Alarm 6, 12, 49, 51, 53, 54 auto start failure 50
b
Backplane 2, 7, 21, 22, 55, 63 bay 2, 19, 20
c
chassis 2, 22
d
Disk 43 disk drive 2, 20 Disk Drives LEDs 43 Drive Bay 19 drive carrier 37 drive carrier handles 11 Drive Carrier Module 2, 11, 20, 36, 43,
46, 50, 63 Drive spin down 63 drive status indicators 11 dummy carrier module 2, 12, 39, 50
e
Enclosure 2, 4, 12, 19, 21, 52, 54 enclosure bay numbering
convention 20 enclosure expansion 31 Enclosure Services Processor 45 Enclosure System Interface/Operators
Panel 6 ESD 21, 55 ESD precautions 63
ESI processor 51 expansion configuration 32
f
fan failure 51 FC_AL signal 46
g
grounding system checks 40
i
IEC 320 connector 40 Input/Output Module 2
l
LED 5, 6, 8, 12, 46, 49, 50, 51, 53
o
Operators Panel 2, 6 Ops Panel 6, 12, 19, 22, 40, 41, 47, 49,
51, 60
Ops Panel LEDs 42, 47
p
plug-in module 2, 19 Power Down 43 Power On 41 power supply cord 23, 40, 55 Power Supply/Cooling 2, 4, 5, 19, 23,
25, 27, 40, 41, 45, 51, 54, 55, 57 PSU LEDs 42, 46 PSU voltage operating ranges 5
r
Rack mounting 2 rack mounting rail kit 21 replacing a module 55 RS232 9
RS-1600/1602-FC-SBD User Guide
68
s
SBD module 2, 7, 9, 19, 29, 31, 46, 49,
51, 61, 62 SBD module LEDs 49 SBOD 2 SEL_ID Address Range selector
switch 6 SEL_ID base address 34 Select ID 46 SES 36 SES drives 35 SFP 9, 31 starting drives 43 SYSTEM LED 50, 51
t
tower kit 3
v
Visible and Audible Alarms 12
Loading...