XtendLan XL-RAID-SATA User Manual

Page 1
XL-RAID-SATA
Data Backup System
User’s Guide
Page 2
1-1 Functions and Features .......................................................... 1
1-2 Product Specification ............................................................ 2
Chapter 2 Hardware Installation ...........................................3
2-1 Contents in the product package ........................................... 3
2-2 System Requirement ............................................................. 4
2-3 Operation Requirement and Caution ..................................... 4
2-4 Detail Description ................................................................. 5
2-5 Installing Hard Drive............................................................. 6
2-5 Installing Hard Drive............................................................. 7
2-6 Connecting XL-RAID-SATA to your computer ................. 10
Chapter 3 How to Operate XL-RAID-ATA........................13
3-1 Setting the Hard Drive Array Mode .................................... 13
3-2 Computer Set Up ................................................................. 15
3-3 LCD Display Message After Turning the Machine On ....... 15
Chapter 4 System Maintenance............................................17
4-1 Hot Swap & Auto Rebuilding ............................................. 17
4-2 Firmware Update ................................................................. 19
Chapter 5 Installing RAIDGuide .........................................22
5.1 Software Introduction .......................................................... 22
5.2 Installing RAIDGuide.......................................................... 23
Appendix A Trouble Shooting Q&A Appendix B Pin Definitions for each connection port Appendix C LCD Display Symbol Definition Chart
Page 3
Chapter 1 Introduction
1 -1 Functions and Features
The XtendLan disk array XL-RAID-SATA provides both RAID 1 and RAID 0 functions with its independent disk array microprocessor chips. It is considered as the best choice for storage expansion and instant online backup.
No hardware driver needed and applicable to all operating
systems
XL-RAID-SATA is equipped with the standard SATA Type 1 and ATA133 connection interfaces. The XL-RAID­SATA system not only possesses high transfer rate but also does not require specific system drivers. Therefore, it can be simply applied to any computer system without any concerns about incompatibility.
Supports both SATA and E_IDE hard drive
XL-RAID-SATA comes with removable hard drive carrier that is compatible with these two types of enclosure module. It can be applied to hard drives with E_IDE interface or to the SATA hard drives.
Hot Swappable Drive
Under the mirroring mode (RAID 1), when one hard drive is damaged, XtendLan allows the system to switch hard drive without pausing the system operations.
Auto Data Rebuilding
Under the mirroring mode (RAID 1), XL-RAID-SATA will treat one hard drive as the source hard drive and the other as the target hard drive. Therefore, it does not require any specific command or system interruption to rebuild the hard drive while the computer system is still running.
1
Page 4
 Hard Drive Backup
Under the mirroring mode (RAID 1), XtendLan can serve as
hard drive backup. It can also be used as system backup or off-line data backup to avoid any virus attack.
LCD Display Screen
The LCD display screen will allow users to monitor and to maintain the system operations.
 System Failure Buzzer
When system failure occurs, XtendLan will not only display the damage status on the LCD display screen but will also generate system alarm as well. The XtendLan system also utilizes Windows version graphic user interface monitoring software which will allow remote maintenance via internet. XtendLan will notify system maintenance technicians once malfunction is detected for immediate repair services.
 Aluminum Alloy Frame
The aluminum alloy frame gives strong and durable structure and serves as the best heat sink.
1-2 Product Specification
Disk Array Hardware Include disk array chips with individual
microprocessor Disk Array Type: RAID 0,1 Connection Interface: SATA Type1 and ATA133 Connection Transfer Rate: Up to 150 MB/ Up to 133 MB Hard drive Interface: SATA Type 1 or ATA 133 Hot Swappable Drive: 2 x (1 inch IDE Hard Drive) Cooling Fans: 5.2 cm ball bearing fan Operating Temperature: 0 ~ 55
Power Input: 12V 4 A, 5V 4 A
°C
2
Page 5
Dimension (MM): 146(width) x 238(length) x 85(height) Weight: 4kg(Hard Drive excluded) Aluminum Alloy Frame: Yes LCD Display: Yes Online Hot Swappable Drive: Yes Auto Rebuild: Yes System Driver Needed: No Certificates: CE, FCC Certificate
Chapter 2 Hardware Installation 2-1 Contents in the product package
The XL-RAID-SATA package contains:
Object Quantity XL-RAID-SATA 1 RS232 Cable 1 Removable Carriers 2 User’s Guide 1 RAIDGuide CD 1 Attachment Pack 1
(includes 6#-32 screws x 8 pcs , Key for keylock x 2 )
3
Page 6
2-2 System Requirement
Hardware Requirement
1. Computers or servers with SATA Type 1 or E_IDE interface.
2. Hard drive with SATA Type 1 or E_IDE interface.
3. The computer or server must run on the Windows system and has RS232 port to install the RAIDGuide GUI software.
2-3 Operation Requirement and Caution
1. XL-RAID-SATA’s brilliant design allows the user to simultaneously utilize two hard drives manufactured by different companies. However, if the user expects better efficiency, we strongly recommend the users to use hard drives manufactured by the same manufacturers.
2. Please carefully select the mode of disk array (RAID 0 or RAID
1) prior to usage. Unless high transfer rate and large storage capacity is needed, otherwise, please use the manufacturer’s default mirror setting (RAID 1). Changing the disk array mode
4
Page 7
after the system setting is completed will result in complete loss and damage to the stored data.
3. Since the system uses more stringent factors to determine the disk corruption in the hard drive, please use noncorrupted hard drive with minimum storage capacity of 20 GB.
4. Please set the first and second hard drive (IDE drives) in XL-
RAID-SATA
to MASTER or Single Drive mode. Otherwise, the system will
not be able to detect the hard drives.
5. The SATA and E_IDE interfaces can not be used simultaneously. If the system detects the E_IDE interface, the system will prefer to use the E_IDE interface.
6. The XL-RAID-SATA had undergone strict hard drive compatibility test. The result shows that it is compatible with most hard drives on the market such as Maxtor, Western Digital, Seagate, Fujitsu, Hitachi, and etc. However, due to the new types of hard drives appearing on the market, if your hard drive is not compatible with the system, please contact us at www.xtendlan.com
or download the latest firmware
updates.
The XL-RAID-SATA is equipped with a 5.2 cm ball bearing cooling fan that will provide effective cooling for the 7200 rpm hard drive. We highly recommend using computer chassis with effective cooling design to avoid disk array crashing due to ineffective cooling.
2-4 Detail Description
Front View
5
Page 8
Rear View
6
Page 9
2-5 Installing Hard Drive
1. Insert key to the lock located at the right side of the tray handle. Turn the key clockwise to open the tray handle.
2. Pull the handle of the removable hard drive carrier.
7
Page 10
3. Remove the removable hard drive carrier.
4. Connect the IDE cables on the removable hard drive carrier to the pins on the hard drive.
5. Secure the hard drive on the removable hard drive carrier by the screws provided in the accessory pack.
8
Page 11
6. Insert the removable hard drive carrier back to XL-RAID-SATA.
7. Lock the screen by turning the key counter clockwise.
9
Page 12
2-6 Connecting XL-RAID-SATA to your computer
Set the Jumper at the back of XL-RAID-SATA
Connect DC12V&4V power cables and SATA or ATA133
cables to XL-RAID-SATA.
Secure RS232 set on the XL-RAID-SATA machine
Connect XL-RAID-SATA to the motherboard COM 1 with
RS232 cables included in the accessory pack as shown in the picture.
10
Page 13
11
Page 14
Note We do not recommend users to disassemble the machine without proper instructions and authorization. The manufacture warranty will not cover damage caused by unauthorized disassembling.
If exchange the parts of XL-RAID-SATA is absolutely necessary, please refer to the diagram in the user’s guide.
12
Page 15
Chapter 3 How to Operate XL-RAID-SATA 3-1 Setting the Hard Drive Array Mode
XL-RAID-SATA can be set on either the mirror (RAID 1) or striping (RAID 0) mode. Once the hard drive array mode is selected, it can not be changed because any changes made afterwards will damage the data stored in the hard drive. Therefore, prior to selecting the hard drive array mode, please ensure the function desired for the XL-RAID-SATA – whether it is used to protect the data or as a hard drive with bigger storage capacity.
There is a switch on the back of the XL-RAID-SATA to allow the user to switch the disk array mode. The default mode is set on the mirror mode (RAID 1). The user can switch to the striping mode (RAID 0) by simply switching the Jumper.
Default Setting
RAID Setting Mirror Mode (RAID 1)
E_IDE Master/Slave Master Drive
Alarm Buzz On
Setting Mirror Mode (RAID 1)
Installing two brand new hard drives
1. Place the two new hard drives into XL-RAID-SATA at the same time.
2. Use the disk monitoring software in the operating system to partition and format the hard drive after turning the machine on. At this point, XL-RAID­SATA will be treated as a single hard drive. If hard drives with different storage capacity are installed, XL-RAID-SATA will automatically detect the storage capacity of each hard drive and treat the hard drive with larger storage capacity as the same capacity of the hard drive with smaller storage capacity.
13
Page 16
3. Install RAIDGuide (Windows User)
Installing a brand new hard drive and a hard drive with
existing data
We highly recommend using the same brand of hard drives with the same or larger storage capacity when installing hard drives to XL-RAID-SATA. The user can use the auto rebuilding function to automatically format the new drive and subsequently to back up the data into the new hard drive.
1. Place the hard drive with existing data into slot 1 or 2 in the XL-RAID-SATA.
2. Since one of the slots is empty, the buzzer will alarm user about the empty slot when the computer is turned on. To shut off the buzzer alarm, just push the bottom located in the front display screen.
3. After turning on the operation system, please check whether the current XL-RAID-SATA setting is the same prior to hard drive installation. Then place the new hard drive in the removable hard drive carrier into another slot. Note: the storage capacity of the newly installed hard drive must be larger than or equal to the old hard drive.
4. The XL-RAID-SATA will start the auto rebuilding function shortly after (please refer to chapter 4 for the auto rebuilding function). The LCD screen will display the backup progress.
5. Please press the Buzzer bottom after auto rebuilding to reset the buzzer alarm and to return the system back to normal operation.
Setting Synchronous Data Saving Mode (RAID 0)
Under the synchronous data saving mode (RAID 0), we suggest
to use two identical hard drives. Once the hard drives are installed, the original files in the hard drives will be removed.
The storage capacity of XL-RAID-SATA is the sum of
the two hard drives installed in the system.
14
Page 17
Under the synchronous data saving mode (RAID 0), the
data can not be protected. If one of the installed hard drives fails, the data will be completely damaged.
Synchronous data saving mode (RAID 0) can not be used
simultaneously with the mirror saving mode (RAID 1). This means that user can only choose one of these two modes before the operation.
Do not turn off power if synchronous data saving mode
(RAID 0) is selected. Otherwise, the data will be lost and damaged.
3-2 Computer Set Up
When the hardware setup for XL-RAID-SATA is complete, you are now ready to turn the machine on.
After the hardware installation is complete, the XL-RAID-SATA will be
treated as one single hard drive. Set the hard drive setup to
AUTO in the computer’s BIOS. When the computer is turned on,
the system will retrieve the following information:
At this point, the installation process is completely finished. The
user can freely retrieve and save data to XL-RAID-SATA
just like retrieving and saving data to a regular hard drive. If
the user
experiences any abnormality during the operation, please refer to
the trouble shooting Q&A section in Appendix A.
15
Page 18
3-3 LCD Display Message After Turning the Machine On
Left Hard Drive (Primary Hard Drive) Fail
Right Hard Drive (Secondary Hard Drive) Normal
Pri HDD : Fail
Primary hard drive storage capacity larger than secondary
hard drive
Secondary hard drive storage capacity larger than primary
hard drive
Sec HDD : OK
Wrong Capacity
PRI>SEC
Wrong Capacity
SEC>PRI
16
Page 19
Chapter 4 System Maintenance 4-1 Hot Swap & Auto Rebuilding
The hard drive Hot Swap and Auto Rebuilding functions are available only under the mirror mode (RAID 1). Synchronous data storage mode (RAID 0) does not support such functions.
The Hot Swap & Auto Rebuilding functions are applicable in
Off-line Back up
When the data is stored within XL-RAID-SATA, the user can remove one of the hard drives from XL-RAID-SATA as back up drive for data such as system operation file, secured files, seldom modified files or image and music files. The user can periodically insert the hard drive back into XL-RAID-SATA to execute automatic backup to protect the system from being hit by computer virus or to avoid risk of having both hard drives failing at the same time.
During Hard drive Failure
When one of the two hard drives fails in the XL-RAID-SATA system, the system will alarm the hard drive failure message both in the LCD display screen and in the monitoring software. The user can remove the failed hard drive from the system while the system is still in operation without shutting down the machine. If the failed hard drive is replaced shortly, the system will automatically execute the Auto Rebuilding function without affecting the system operation and without any operation command from the user.
The LCD Display Message During Hot Swap and Auto Rebuilding
When the XL-RAID-SATA detects a hard drive missing or a hard drive failure, the Buzzer will go off and the LCD display screen will display the following messages:
17
Page 20
Pri HDD : OK
Sec HDD : Fail
Pri HDD : Fail
Sec HDD : OKl
1. After removing the failed hard drive and replacing with a new
hard drive, if the hard drive is properly installed, the LCD display screen will display the following messages:
Pri HDD : OK
Sec HDD : OK
2. After few seconds of installing the new hard drive, the LCD
display screen will display the data rebuilding progress:
Rebuilding …
Pri->Sec XXX%
Rebuilding …
Sec->Pri XXX%
Pri->Sec represents that the data in the original hard drive (primary hard drive) is copied to the new hard drive (secondary hard drive). XXX % represents the rebuilding completion percentage.
3. When the rebuilding is fully completed, the LCD display screen
will again display the following messages:
Pri HDD : OK Sec HDD : OK
18
Page 21
4-2 Firmware Update
Since the specification of computer hardware is constantly upgraded due to the advancement in the computer technologies, some of the Firmware might not be fully compatible with XL-RAID-SATA. Prior to installing the new version of Firmware, the user must first examine the system specification to ensure the new Firmware version is supported by the user’s system. Ensuring the compatibility of the new version of Firmware will prevent the system from failing to start. Please contact our local distributor representative and our technical support staff for any questions concerning Firmware update.
Upgrade Preparation and System Requirements
1. Please prepare a Windows 98 or DOS operating system boot disk
or boot hard drive.
2. Please prepare an E_IDE Cable since the Firmware upgrade must
done through the E_IDE interface.
3. From the attached CD in the XL-RAID-SATA package, copy the
Firmware upgrade tool program “Kflash.exe” to the boot disk or to the boot hard drive.
4. Copy the desired Firmware upgrade files to the boot disk or the
boot hard drive.
Upgrade Procedure
1. Please open the system frame and connect the E_IDE interface.
2. Set the Switch on the rear of the XL-RAID-SATA to the Update Firmware status.
19
Page 22
3. Boot up the system with the boot disk or boot hard drive.
4. Execute upgrade software after turning the system on.
filePath\kflash x filepath\filename
filepath : The path of flash211.exe and new firmware Filename : The name of new firmware X : The location of XL-RAID-SATA series
As x=0 is master on primary IDE channel
x=1 is slave on primary IDE channel x=2 is master on secondary IDE channel x=3 is slave on secondary IDE channel
5. System will ask you whether to save the old version firmware or
20
Page 23
not?
6. Start to upload firmware.
7. Update is successful in case of no any errors displayed.
PS: There is no driver required when carrying out the firmware updating.
21
Page 24
Chapter 5 Installing RAIDGuide
r
5.1 Software Introduction
RAIDGuide is a graphic user interface monitoring program which is designed to control the RAID system. It can receive the RAID system information via the PC serial ports and displays such information on the monitor screen. The displayed information include system status, hard drive status (hard drive failure, system failure, hard drive insert and confirmation) and the data rebuild progress. This program provides users with monitoring interfaces that are simple and easy to operate.
Function and Features
Support the connection between two RAID systems.
Notify the technicians about system or hard drive failures via
email.
Support the PC sound alert function and activate wav or midi
files in case of system or hard drive failures.
Support up to 20 users to remotely monitor the RAID system.
Minimize window and automatically restart the windows
operating system in case of system and hard drive failure.
Provide instant cooling fan operation status, current temperature,
hard drive operation status, and system failure detection.
Operating system requirement
Hardware Specification
Processo
Memory 64MB
Connector cable 1 Set
Hard drive storage capacity 10 MB
Screen resolution (recommended) 800 ×600
22
Pentium
Page 25
5.2 Installing RAIDGuide
Place the RAIDGuide graphic user interface monitoring program CD into the CD ROM. Double click the Set.exe file to begin the installation process. You can select under which file folder or directory destination the program will be installed. After completing the RAIDGuide graphic user interface monitoring program installation, you can immediately use this software without restarting the computer.
Please refer tot her RAIDGuide user’s guide in the program CD for instructions on how to use the RAIDGuide.
23
Soho RAID
Page 26
Appendix A Trouble Shooting Q&A
Unstable system after connecting XL-RAID-SATA
Q1: After installing XL-RAID-SATA, we are unable to start
the computer or the computer can not locate XL-RAID­SATA upon startup.
A:1. Please check whether the readings on the XL-RAID-SATA
LCD display screen appear normal.
2. Please check whether the IDE and/or SATA Cable connection cables are properly connected to the computer system and whether IDE and/or SATA drives are functioning normally. If both the IDE and SATA cables are connected, the computer system will choose to run the IDE drive first.
3. If everything is functioning properly but the user still can not start the computer system, then the problem might be the system incompatibility. If such incompatibility takes place, please contact our technical support department.
Q2: When the XL-RAID-SATA is in use, the computer
system is functioning normally but the XL-RAID­SATA access speed is abnormal.
A:1. Please first check whether the XL-RAID-SATA is in the
progress of executing data auto-rebuild.
1. Please examine if the length of the connection cables, SATA Cable or IDE Cable, that connect the drives to the computer system is too long and whether the specification these cables complies with the requirements.
2. If both the lengths and specification of the cables are checked out ok, please turn off XL-RAID-SATA and remove the hard drive from XL-RAID-SATA. Test the hard drive directly with the computer
24
Page 27
system since it might be the bad sectors in the hard drive that are causing the longer than normal system down time.
Hard Drive Failure
Q3: Under the mirror mode (RAID 1), what will be the
system’s total storage capacity when adding a brand new hard drive?
A: 1. The total storage capacity for XL-RAID-SATA is
determined by the storage capacity of the primary hard drive installed during the initial usage.
2. The storage capacity will not increase after initial installation even when place a brand new hard drive with larger storage capacity.
Q4: Why does the error message appear when I installed the second hard drive?
A:1. The storage capacity of the second hard drive must be
larger than the first hard drive. Otherwise, XL-RAID­SATA can not rebuild the new hard drive and the LCD display screen will display “Wrong Capacity”.
2 The LCD display screen might display rebuilding error
messages such as Pri(s)->Sec(s) or Sec(s)->Pri(s). The term (s) signifies that both hard drives are treated as original hard drive. The user must determine which hard drive will be the original hard drive prior installing the hard drives into XL-RAID-SATA. Once the original hard drive is designated and installed in XL-RAID­SATA, the user can place in the second hard drive by taking advantage of XL-RAID-SATA’s Auto Rebuilding function.
Q5: My hard drive is obviously operating properly but why
is it shown as failed in the XL-RAID-SATA display?
A: 1. XL-RAID-SATA uses more strict requirements and
standards to examine the bad sectors in the hard drive. The user can first overwrite the bad sector on a PC before placing the hard drive into XL-RAID-SATA.
2. The Hard Drive Jumper is not properly set on the Master or Single Drive position. The manufacture setting of current
25
Page 28
hard drives on the market is set on Cable Select and XL-RAID-SATA will be able to detect the hard drive
About Auto Rebuilding Function
only if the setting is on Cable Select.
Q6: What will happen if we turn off the computer’s power while
XL-RAID-SATA is still executing data auto rebuilding?
A: Under the mirror mode (RAID 1), if the power is out in the
middle of auto rebuilding process, the controller will remember when completion percentage of the auto rebuilding process and resume the rebuilding process when the power is back on.
Q7: Is it possible to lose any part of the data during the data
auto rebuilding?
A:1. The data auto rebuilding function will copy data from one
sector to another sector. Technically speaking, the data will not be lost during the auto rebuilding process. However, if the original hard drive is detected with bad sectors during the rebuilding process, XL-RAID-SATA will make hypothetical duplication instead of treat the bad sectors as hard drive failure. Therefore, the data stored in the bad sectors could potentially be lost during rebuilding.
Q8: Under the mirror mode (RAID 1), why does the
computer slows down during the data rebuilding process? Or why does the data rebuilding process slows down when the data is being processed?
A: If the XL-RAID-SATA system is executing data
rebuilding simultaneously while the computer system is saving the data, the auto rebuilding process and the saving process will take longer than normal time. This is because the XL-RAID-SATA must divide it resources between the normal system operation and the data rebuilding process.
26
Page 29
However, the priority for the XL-RAID-SATA is to maintain the proper system operations. Therefore, the data rebuilding speed will be extremely slow until the system finished with the data saving operations.
Other Possible Situations
Q9: The Buzzer will not stop when the XL-RAID-
SATA is in operation.
A: Please check whether the readings on the LCD display are
normal or if there is a hard drive failure. Please also pay attention to any other symbols displayed in the LCD display. For example, if the “F” symbol is displayed, this means that there is a cooling fan failure. If the “T” symbol is displayed, this means that the system is overheated.
Q10: How to turn on and off the Buzzer? A: 1. The manufacture default setting for the Buzzer in
XL-RAID-SATA is Buzzer On.
2. The user can use any pointed materials to push the bottom on the front dash board to turn on and off the Buzzer.
27
Page 30
Appendix B Pin Definitions for each connection
N.CN
N
port
RS-232 PORT PIN OUT
RS-232 PIN OUT
PIN-1 PIN-2 PIN-3
RX TX GND
POWER PORT
DC POWER PIN OUT
PIN-1 PIN-2 PIN-3 PIN-4
12V GND GND 5V
JUMPER SETUP
.C
.C RAID-0
SW1 SETTING
PIN OUT JUMP1 JUMP2 JUMP3 JUMP4 JUMP5
ON MASTER CSEL UPGRADE N.C RAID-1
OFF SLAVE
NOTES: BLUE WORD IS DEFAULT
28
Page 31
Appendix C LCD Display Symbol Definition Chart
ror
m
p
N
y
N
XL-RAID-SATA LCD List
1. Mirroring Mode Case 1 : Power On
Power On "2044 06/09 03:00"
Normal " Pri HDD : OK"
X-Drive Fail or EmptyTray Y-Drive Fail or
tyTray
E Non-X-Drive " Pri HDD : Off"
Non-Y-Drive " Pri HDD : OK"
Non-X-Drive &
on-Y-Drive
LCD display
"Mir
" Sec HDD: OK" " Pri HDD : OK" " Sec HDD: Fail" " Pri HDD : Fail" " Sec HDD: OK"
" Sec HDD: OK"
" Sec HDD: Off" " Pri HDD : Off" " Sec HDD: Off"
"
Case 2: HDD Swap Out or Failed
LCD Display
X-Drive Swap Out or Failed Y-D ri ve S wap Ou t o r Failed XY-Drive Swap Out or Failed
Case 3 : New Swap-in and Rebuild Mode
X-Drive S (Source) S (Source) System Failed RebuildFlag ERR
T (Target) T (Target) System Failed RebuildFlag ERR
N (No Flag) N (No Flag) Normal operation Pri HDD: OK
S (Source)
Y- D ri v e Active LCD displa
(No Flag) Rebuilding Rebuilding ...
“Pri HDD: OK” “Sec HDD: Fail” “Pri HDD: OK” “Sec HDD: Fail” " Pri HDD : Off" " Sec HDD: Off"
PRI: S SEC: S
PRI:T SEC: T
Sec HDD: OK
29
Page 32
S (Source) N (No Flag) Rebuild Check Err
Y-Drive be Target Pri => Sec 00%
1
RebuildFlag ERR Muti-sector Err
N (No Flag) S (Source) Rebuild Check Err
S (Source) T (Target) Rebuilding Rebuilding ...
S (Source) U (Unknown) System Failed RebuildFlag ERR
N (No Flag) S (Source) Rebuilding
T (Target) S (Source) Rebuilding Rebuilding...
T (Target) U (Unknown) System Failed RebuildFlag ERR
N (No Flag) T (Target) System Failed RebuildFlag ERR
N (No Flag) U (Unknown) System Failed RebuildFlag ERR
U (Unknown) S (Source) System Failed RebuildFlag ERR
Rebuild Check Err 2
Rebuild Check Err 3
Rebuild Check Err 4
1
Rebuild Check Err 2
Rebuild Check Err 3
Rebuild Check Err 4
X-Drive be Target
RebuildFlag ERR UDMA Mode Err
RebuildFlag ERR SATA Mode Err
RebuildFlag ERR Wrong Capacity
RebuildFlag ERR Muti-sector Err
RebuildFlag ERR UDMA Mode Err
RebuildFlag ERR SATA Mode Err
RebuildFlag ERR Wrong Capacity
Pri => Sec ??%
PRI: S SEC: X Rebuilding... Sec => Pri 00%
Sec => Pri ??%
PRI: T SEC: X
PRI: N SEC: T
Unknow Flag
PRI: X SEC: S
30
Page 33
U (Unknown) T (Target) System Failed RebuildFlag ERR
m
p
m
p
U (Unknown) N (No Flag) System Failed RebuildFlag ERR
U (Unknown) U (Unknown) System Failed RebuildFlag ERR
Case 4: After Rebuild finish:
Rebuild finish “Pri HDD : OK”
2. Striping Mode Case 1 : Power On
Power On "2044 06/09 03:00"
Normal " Pri HDD : OK"
X-Drive Fail or
tyTray
E Y-Drive Fail or
tyTray
E Non-X-Drive " Pri HDD : Off"
Non-Y-Drive " Pri HDD : OK"
Non-X-Drive & Non-Y-Drive
Case 2: HDD Swap Out or Failed
LCD Display
“Sec HDD: OK”
LCD display
" 2Strip "
" Sec HDD: OK" " Pri HDD : OK" " Sec HDD: Fail" " Pri HDD : Fail" " Sec HDD: OK"
" Sec HDD: OK"
" Sec HDD: Off" " Pri HDD : Off" " Sec HDD: Off"
LCD Display
PRI: X SEC: T
Unknow Flag
Unknow Flag
X-Drive Swap Out or Failed Y-D ri ve S wap Ou t o r Failed XY-Drive Swap Out or Failed
“Pri HDD: OK” “Sec HDD: Fail” “Pri HDD: OK” “Sec HDD: Fail” " Pri HDD : Off" " Sec HDD: Off"
31
Page 34
3. Other
FAN Fail F
Temperature alarm T
LCD Display
32
Loading...