XL-RAID-2803SISA
XL-RAID-2803SSSA
XL-RAID-2803FCSA
2U 8bays, SCSI U320 – SATAII / SAS
– SATAII / FC- SATAII RAID Subsystem
The most cost-effective SATA II RAID subsystem, the XL-RAID-2803x series RAID subsystem
features SCSI U320, 3Gb SAS or 4Gb FC-AL host interface to increase system efficiency and
performance. It carries 8 hot-swappable SATA II hard disk drive bays in a 19-inch 2U rackmount unit,
scaling the storage capacity of server in the terabyte range, provides a fast and easy way to install and
upgrade your storage.
Ex
ce pt io na l Ma na gea bi li ty
- The firmware-embedded Web Browser-based RAID manager allows local or remote management
and configuration
- Th e firmware-embedded SMTP manager monitors all system events and user notification
automatically
- The firmware-embedded SNMP agent allows remote to monitor events via LAN with no SNMP agent
required
- Menu-driven front panel display
Fea tur es
- Supports online array roaming
- Online RAID level/stripe size migration
- Online capacity expansion and RAID level migration simultaneously
- Online volume set expansion
- Supports multiple array enclosures per host connection
- Supports greater than 2TB per volume set
- Transparent data protection for all popular operating systems
- RAID ADG provides the highest level of data protection
- Instant availability and background initialization
- Supports S.M.A.R.T, NCQ and OOB staggered Spin-up capable drives
- Local audible event notification alarm.
- Supports password protection
- Serial port interface for remote event notification
- Redundant flash image for high availability
- Support spin down drives when not in use to extend service (MAID)
- Supports bad blocks auto remapping and schedule volume check
- Supports hot spare and automatic hot rebuild

Series Technical
Specif
ications
Model
RAID Controller
RAID processor
Cache memory
No.of channels (Host+Drive)
Host Interface
Disk Interface
Management port support
Monitor port support
RAID Features
RAID level
Array group
LUNs
Hot spare Drive
roaming Online
rebuild Variable
stripe size E-mail
notification
Online capacity expansion,
RAID level / stripe size migration
Online array roaming
Online consistency check
SMTP manager and SNMP agent
Redundant flash image
Instant availability and
background initialization
S.M.A.R.T. support
MAID
Bad block auto-remapping
Enclosure
Platform
Form factor
# of hot swap trays
Tray lock
Disk status indicator
Power supply
# of fans
Power requirements
Environmental
humidity Operating
temperature Physical
dimension Weight
(Without disk)
Relative
XL-RAID-2803SISA
Intel IOP348 64 bit RISC
512MB ~ 4GB
DDRII ECC SDRAM
2+8
Two SCSI Ultra 320
SATA II
Yes
Yes
0, 1, 10(1E), 3, 5, 6
and JBOD
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Rackmount
2U
8
Yes
Access / Fail LED
300W x 2
4
AC110V / 220
6A / 3A, 47Hz / 63Hz
10% ~ 85% Non-condensing
10°C~40°C(50°F ~ 104°F)
88 (H) x 482(W) x 500 (D) mm
12.5Kg
XL-RAID-2803SSSA
Intel IOP348 64 bit RISC
512MB ~ 4GB
DDRII ECC SDRAM
2+8
Two 4x mini SAS(3Gb/s)
SATA II
Yes
Yes
0, 1, 10(1E), 3, 5, 6 ,
30, 50, 60 and JBOD
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Rackmount
2U
8
Yes
Access / Fail LED
300W x 2
4
AC110V / 220
6A / 3A, 47Hz / 63Hz
10% ~ 85% Non-condensing
10°C~40°C(50°F ~ 104°F)
88 (H) x 482(W) x 500 (D) mm
12.5Kg
XL-RAID-2803FCSA
Intel IOP348 64 bit RISC
512MB ~ 4GB
DDRII ECC SDRAM
2+8
Two FC-AL(4Gb/s)
SATA II
Yes
Yes
0, 1, 10(1E), 3, 5, 6 ,
30, 50, 60 and JBOD
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Rackmount
2U
8
Yes
Access / Fail LED
300W x 2
4
AC110V / 220
6A / 3A, 47Hz / 63Hz
10% ~ 85% Non-condensing
10°C~40°C(50°F ~ 104°F)
88 (H) x 482(W) x 500 (D) mm
12.5Kg