XtendLan XL-RAID-225 User Manual

XL-RAID
SATA II-to-SATA II
Internal RAID Subsystem
Installation and Configuration Manual
Revision
1.0
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
2
Contents
Preface.....................................................................................................................................................3
Before You Begin ...................................................................................................................................4
Chapter 1 Introduction .........................................................................................................................6
1.1 Technical Specification....................................................................................................................7
1.2 Identifying Parts of the RAID Subsystem........................................................................................8
1.2.1 Front View....................................................................................................................................8
1.2.1.1 Disk Drive Carrier .....................................................................................................................9
1.2.1.2 LED Indicators...........................................................................................................................9
1.2.2 Rear View....................................................................................................................................10
1.3 RAID Concepts .............................................................................................................................11
Chapter 2 Getting Started....................................................................................................................14
2.1 Installing Hard Drives ...................................................................................................................14
2.2 Preparing the RAID Subsystem.....................................................................................................16
Chapter 3 Configuration Utility .........................................................................................................17
3.1 Starting the AP in Microsoft Windows..........................................................................................18
3.2 Starting the AP in Linux.................................................................................................................19
3.3 Starting the AP in Mac OS ............................................................................................................20
3.4 XtendLan Management GUI .........................................................................................................21
3.4.1 Other Buttons of the XtendLan ManagementGUI .....................................................................22
Chapter 4 RAID Management............................................................................................................24
4.1 Basic Mode ....................................................................................................................................24
4.1.1 RAID and Disk Information........................................................................................................24
4.1.2 Event Log....................................................................................................................................27
4.1.3 Basic Raid Configuration............................................................................................................28
4.2 AdvancedMode ...............................................................................................................................32
4.2.1 SMART Information...................................................................................................................32
4.2.2 Email Notification.......................................................................................................................33
4.2.3 Advanced Raid Configuration.....................................................................................................34
4.2.4 Firmware Information.................................................................................................................38
4.2.5 System Information.....................................................................................................................40
SATA II-to-SATA II Internal RAID Subsystem
3
Ins
tallation and Configuration Manual
Preface
About this manual
his manual provides information regarding the quick installation and hardware features of the SATA II-to-SATA II Internal RAID subsystem. This document also describes how to use the storage management software. Information contained in the manual has been reviewed for accuracy, but not
for product warranty because of the various environment/OS/settings. Information and specifications will be changed without further notice.
This manual uses section numbering for every topics being discussed for easy and convenient way of finding information in accordance with the user’s needs. The following icons are being used for some details and information to be considered in going through with this manual:
NOTES:
These are notes that contain useful information and tips that the user must give attention to in going through with the subsystem operation.
IMPORTANT!
These are the important information that the user must remember.
WARNING!
These are the warnings that the user must follow to avoid unnecessary errors and bodily injury during hardware and software operation of the subsystem.
CAUTION:
These are the cautions that user must be aware to prevent damage to the equipment and its components.
Copyright
No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent.
Trademarks
All products and trade names used in this document are trademarks or registered trademarks of their respective holders.
Changes
The material in this document is for information only and is subject to change without notice.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
4
Before You Begin
efore going through with this manual, you should read and focus on the following safety guidelines. Notes about
the subsystem’s controller configuration and the product packaging and delivery are also included. To provide reasonable protection against any harm on the part of the user and to
obtain maximum performance, user is advised to be aware of the following safety guidelines particularly in handling hardware components:
Upon receiving of the product:
Place the product in its proper location.It should be handled with care to avoid dropping that may cause damage to the
product. Always use the correct lifting procedures.
Upon installing of the product:
Ambient temperature is very important for the installation site. It must not
exceed 30◦C. Due to seasonal climate changes; regulate the installation site temperature making it not to exceed the allowed ambient temperature.
Before plugging-in any power cords, cables and connectors, make sure that the
power switches are turned off. Disconnect first any power connection if the power supply module is being removed from the enclosure.
Outlets must be accessible to the equipment.All external connections should be made using shielded cables and as much as
possible should not be performed by bare hand. Using anti-static hand gloves is recommended.
In installing each component, secure all the mounting screws and locks. Make
sure that all screws are fully tightened. Follow correctly all the listed procedures in this manual for reliable performance.
Controller Configurations
This RAID subsystem supports single controller configuration.
Packaging, Shipment and Delivery
Before removing the subsystem from the shipping carton, you should visually
inspect the physical condition of the shipping carton.
Unpack the subsystem and verify that the contents of the shipping carton are all
there and in good condition.
Exterior damage to the shipping carton may indicate that the contents of the
carton are damaged.
If any damage is found, do not remove the components; contact the dealer where
you purchased the subsystem for further instructions.
SATA II-to-SATA II Internal RAID Subsystem
5
Ins
tallation and Configuration Manual
Unpacking the Subsystem
The package contains the following items:
Internal RAID subsystem unit
One SATA cable
Installation Reference Guide
llation and Configuration Manual
6
Chapter 1 Introduction
The Internal RAID Subsystem
Unsurpassed Value
- Most cost-effective SATA II RAID subsystem.
- Compact Desktop size with stylish design.
Application Flexibility
- Extends useful life by adapting to future IT/SOHO requirements.
Easy Installation & Maintenance
- Provide a fast and easy way to install and manage the storage.
Low Power Consumption
- Cable-less backplane with integrated RAID processor. No more unnecessary components inside.
Features
- SATA II (3GBps) host interface
- Over 2TB support
- Supports hot spare and automatic hot rebuild
- Local event notification
- Easy management via In-Band data bus
- Transparent data protection for all popular operating systems
RAID Management
- Real time drive activity and status indicators
- Graphical User Interface (GUI) management utility
SATA II-to-SATA II Internal RAID Subsystem
SATA II-to-SATA II Internal RAID Subsystem
7
Ins
tallation and Configuration Manual
1.1 Technical Specification
Model XL-RAID-225
Form Factor Internal RAID Box
RAID Processor Integrated Micro-processor
RAID Levels 0, 1, 3, 5, 10, LARGE, CLONE
Host Interface SATA II
No. of channels (host+drive) 1+5
Data Transfer Rate Up to 3.0Gbps
Disk Interface SATA II (3Gbps)
Number of Hot-swap Disk Trays Five (5) 2.5-inch SFF Disk trays
Cooling Fans 1
Failed Drive Indicators Yes
Failed Drive Auto Rebuild Yes
Environment Monitor Yes
Auto Spare Support Yes
Over 2TB Support Yes
Environmental Relative Humidity:
Operating Temperature:
10% ~ 85% Non-condensing 10°C ~ 40°C (50°F ~ 104°F)
Dimension 84(H) x 146(W) x 190(D)mm
Weight 1.43Kg (without disk)
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
8
1.2 Identifying Parts of the RAID Subsystem
The illustrations below identify the various parts of the subsystem.
1.2.1 Front View
SATA II-to-SATA II Internal RAID Subsystem
9
Ins
tallation and Configuration Manual
1.2.1.1 Disk Drive Carrier
HDD Status Indicator
Part
Function
HDD Access LED
This LED will blink blue when the hard drive is busy or being accessed.
HDD Fault LED
Green LED means HDD is good. Red LED indicates hard drive has failed. No LED light means no hard drive in the slot.
1.2.1.2 LED Indicators
Part
Function
Fan Fail LED
Green LED means Fan is good. Red LED means Fan has failed.
Over Temp LED
Green LED means Temperature is normal. Red LED means Temperature exceeded normal.
Power On LED
White LED means RAID subsystem is powered on.
llation and Configuration Manual
10
1.2.2 Rear View
SATA Port
The RAID subsystem has one 3Gbps SATA port for connecting to host system/server.
Fan
The fan provides proper ventilation for the RAID subsystem.
Power Socket
The RAID subsystem has two power sockets to plug in power connectors.
SATA II-to-SATA II Internal RAID Subsystem
SATA II-to-SATA II Internal RAID Subsystem
11
Ins
tallation and Configuration Manual
1.3 RAID Concepts
he basic idea of RAID (Redundant Array of Independent Disks) is to combine multiple inexpensive disk drives into an array of disk drives to obtain performance, capacity and reliability that exceeds that of a single large drive. The array of drives appears to the host computer as a single logical drive. Five
types of array architectures, RAID 1 through RAID 5, were originally defined; each provides disk fault­tolerance with different compromises in features and performance. In addition to these five redundant array architectures, it has become popular to refer to a non-redundant array of disk drives as a RAID 0 arrays.
Disk Striping
Fundamental to RAID technology is striping. This is a method of combining multiple drives into one logical storage unit. Striping partitions the storage space of each drive into stripes, which can be as small as one sector (512 bytes) or as large as several megabytes. These stripes are then interleaved in a rotating sequence, so that the combined space is composed alternately of stripes from each drive. The specific type of operating environment determines whether large or small stripes should be used.
Most operating systems today support concurrent disk I/O operations across multiple drives. However, in order to maximize throughput for the disk subsystem, the I/O load must be balanced across all the drives so that each drive can be kept busy as much as possible. In a multiple drive system without striping, the disk I/O load is never perfectly balanced. Some drives will contain data files that are frequently accessed and some drives will rarely be accessed.
By striping the drives in the array with stripes large enough so that each record falls entirely within one stripe, most records can be evenly distributed across all drives. This keeps all drives in the array busy during heavy load situations. This situation allows all drives to work concurrently on different I/O operations, and thus maximize the number of simultaneous I/O operations that can be performed by the array.
llation and Configuration Manual
12
Definition of RAID Levels
RAID 0 is typically defined as a group of
striped disk drives without parity or data redundancy. RAID 0 arrays can be configured with large stripes for multi-user environments or small stripes for single-user systems that access long sequential records. RAID 0 arrays deliver the best data storage efficiency and performance of any array type. The disadvantage is that if one drive in a RAID 0 array fails, the entire array fails.
RAID 1, also known as disk mirroring, is simply a pair of disk drives that store duplicate data but appear to the computer as a single drive. Although striping is not used within a single mirrored drive pair, multiple RAID 1 arrays can be striped together to create a single large array consisting of pairs of mirrored drives. All writes must go to both drives of a mirrored pair so that the information on the drives is kept identical. However, each individual drive can perform simultaneous, independent read operations. Mirroring thus doubles the read performance
of a single non-mirrored drive and while the write performance is unchanged. RAID 1 delivers the best performance of any redundant array type. In addition, there is less performance degradation during drive failure than in RAID 5 arrays.
Dual-level RAID achieves a balance between the increased data availability inherent in RAID 1 and the increased read performance inherent in disk striping (RAID 0). These arrays are sometimes referred to as RAID 10.
RAID 3 sector-stripes data across groups of
drives, but one drive in the group is dedicated
to storing parity information. RAID 3 relies on
the embedded ECC in each sector for error
detection. In the case of drive failure, data
recovery is accomplished by calculating the
exclusive OR (XOR) of the information
recorded on the remaining drives. Records
typically span all drives, which optimizes the
disk transfer rate. Because each I/O request
accesses every drive in the array, RAID 3
arrays can satisfy only one I/O request at a
time. RAID 3 delivers the best performance
SATA II-to-SATA II Internal RAID Subsystem
SATA II-to-SATA II Internal RAID Subsystem
13
Ins
tallation and Configuration Manual
for single-user, single-tasking environments with long records. Synchronized-spindle drives are required for RAID 3 arrays in order to avoid performance degradation with short records. RAID 5 arrays with small stripes can yield similar performance to RAID 3 arrays.
Under
RAID 5 parity information
is distributed across all the drives. Since there is no dedicated parity drive, all drives contain data and read operations can be overlapped on every drive in the array. Write operations will typically access one data drive and one parity drive. However,
because different records store their parity on different drives, write operations can usually be overlapped.
RAID Management
The subsystem can implement several different levels of RAID technology. RAID levels supported by the subsystem are shown below.
RAID Level Description Min. # of Drives
0
Block striping is provided and yields higher performance than with individual drives. There is no redundancy.
2
1
Drives are paired and mirrored. All data is 100% duplicated on an equivalent drive. Fully redundant.
2
LARGE
Large is similar to RAID 0 in that it combines the capacity of all member drives (based on smallest drive capacity). The data is written linearly from first disk drive. When first disk drive becomes full, the next disk drive is used. Large can have 2 or more disk drives. There is no data redundancy.
2
CLONE
Clone provides multiple copies of data in a disk drive. Clone can have 2 or more disk drives.
2
3
Data is striped across several physical drives. Parity protection is used for data redundancy.
3
5
Data is striped across several physical drives. Parity protection is used for data redundancy.
3
10
Combination of RAID levels 1 and 0. This level provides striping and redundancy through mirroring.
4
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
14
Chapter 2 Getting Started
This section describes the physical locations of the hard drives supported by the subsystem and give instructions on installing a hard drive. The subsystem supports hot-swapping allowing you to install or replace a hard drive while the subsystem is running.
This also discusses on how to power-on the subsystem in preparation for operation.
2.1 Installing Hard Drives
a. Push the tray latch to release a disk tray.
b. Then pull out an empty disk tray.
c. Place the hard drive in the disk tray. Make sure the holes of the disk tray align
with the holes of the hard drive.
SATA II-to-SATA II Internal RAID Subsystem
15
Ins
tallation and Configuration Manual
d. Install the mounting screws on the bottom part to secure the drive in the disk
tray.
e. Slide the tray into a slot until it reaches a full stop.
f. Press the lever in until you hear the latch click into place.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
16
2.2 Preparing the RAID Subsystem
Here are the steps to prepare the RAID subsystem for use.
1. Shutdown the host system.
2. Install the Internal RAID Box into the host system and secure it by using screws on the sides.
3. Connect the SATA cable from RAID subsystem to the SATA port on the host system.
4. Connect two 4-pin power connectors to the two power sockets.
5. Power on the host system.
SATA II-to-SATA II Internal RAID Subsystem
17
Ins
tallation and Configuration Manual
Chapter 3 Configuration Utility
The subsystem has a setup configuration utility containing important information about the configuration as well as settings for various optional functions in the subsystem. This chapter explains how to use and make changes to the setup utility.
Configuration Method
The RAID subsystem can be configured using the Application Program provided with the subsystem. There are three versions: Microsoft Windows version, Linux version, and Mac OS version.
IMPORTANT: The RAID subsystem must be connected to the Host system in order to configure the RAID subsystem. If the RAID subsystem is not connected to the Host system, the Application Program will show “No disks or RAID!”
NOTE: At least disk drive must be inserted in the RAID subsystem. If there is no disk drive in the RAID subsystem, the Application Program will show “No disks or RAID!”
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
18
3.1
Starting the
AP in Microsoft Windows
To configure the RAID subsystem, go to the directory where the Application Program is saved and open/run the Application Program.
After running the Application Program, the XL-RAID main screen will be displayed.
SATA II-to-SATA II Internal RAID Subsystem
19
Ins
tallation and Configuration Manual
3.2 Starting the AP in Linux
To configure the RAID subsystem when connected to Linux system, go to the directory where the Application Program is saved and open the Application Program.
This example is from Fedora Core 9.
Another way is to open terminal window, then at the command prompt type “./XLRaidSetup.
After running the Application Program, the XL-RAID main screen will be displayed.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
20
3.3 Starting the AP in Mac OS
To configure the RAID subsystem when connected to Mac OS X Server, go to the directory where the Application Program is saved and open the Application Program.
This example is from Mac OS X Server version 10.5.4.
After running the Application Program, the XL-RAID main screen will be displayed.
SATA II-to-SATA II Internal RAID Subsystem
21
Ins
tallation and Configuration Manual
3.4 XL-RAID Management GUI
The XL-RAID management GUI contains the following menu options:
Basic Mode:
RAID and Disk Information
Provides information about RAID and disk drives.
Event Log
Shows the RAID controller event log.
Basic Raid Configuration
Provides function for creating basic RAID configuration. This function will use all available disk drives.
Advanced Mode:
SMART Information
This function will show SMART information of the SATA disk drives if SMART function is supported by the disk drives.
Email Notification
This function provides option to configure email for sending event notifications when events happen.
Advanced Raid Configuration
This function provides option to customize RAID configuration and select disk drive members.
Firmware Information
Shows information about current firmware and provides function to upgrade the firmware version.
System Information
Shows information about the system such as temperature, fan speed and voltage levels.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
22
3.4.1 Other Buttons of the XL-RAID Management GUI
Minimize Window button – Used to minimize the XL-RAID GUI into taskbar.
Close Windows button – Used to close the XL-RAID GUI.
Note that the AP is still running in the background. To exit the AP, right-click the XL-RAID icon in the task bar then select Quit from the pop-up menu.
SATA II-to-SATA II Internal RAID Subsystem
23
Ins
tallation and Configuration Manual
About button – Used to display the current XL-RAID AP version.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
24
Chapter 4 RAID Management
This chapter provides details about configurations and options available in the RAID subsystem. There are two modes of operation: Basic Mode and Advanced Mode.
4.1 Basic Mode
Under Basic Mode, there are three menu options that can be selected: RAID and Disk Information, Event Log, and Basic Raid Configuration.
4.1.1 RAID and Disk Information
RAID and Disk Information provides information about RAID and disk drives.
RAID and Disk Information: No existing RAID configuration
SATA II-to-SATA II Internal RAID Subsystem
25
Ins
tallation and Configuration Manual
Disk Information: Disk drive is “Unused” or not a RAID member.
RAID Information: Disk Drives are RAID 5 member.
RAID Information:
RAID Level – Shows the RAID Level of the RAID Status – Shows the current status of the RAID. Status can be:
Normal – No failed disk drive. Degrade – One or more disk drives failed in a RAID Level with data
redundancy. The data is still accessible.
Broken – One or more disk drives failed in a RAID Level. The number of
allowable failed disk drives in the RAID Level has been exceeded and data is not accessible.
Rebuilding (%) – The RAID is in rebuilding state. The completed rebuilding
percentage is shown. Capacity – Shows the capacity of the RAID Plugged Member(s) – Shows the disk drive slots which are member of the RAID
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
26
Disk Information: Disk drive is a RAID member.
Disk Information:
Model Name – Shows the disk drive model Serial Number – Shows the disk drive serial number Capacity – Shows the capacity of the disk drive Unused Capacity – Shows the amount of unused capacity in the disk drive
SATA II-to-SATA II Internal RAID Subsystem
27
Ins
tallation and Configuration Manual
4.1.2 Event Log
The RAID controller event log can be viewed from this menu. It will show the Number of Events, the Issued Module, Date, Type, and Message.
Event Log Buttons:
Save To File – This option allows the event logs to be saved as a log text file (.log).
Enter the filename you want for the log file and click “Save”.
Clear – Selecting this option will clear the event log. When the dialog box shown below
is displayed, select “Yes” to delete all event logs.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
28
4.1.3 Basic Raid Configuration
This menu provides function for creating basic RAID configuration. This function will use all available disk drives in the RAID subsystem.
Basic Raid Configuration Options:
Configure RAID – Select the RAID Level from the list of options. The RAID
Levels that can be selected for the number of available disk drives are enabled. When there is an existing RAID, the “DELETE ALL RAID(s)” option is enabled.
Support Password – This option provides RAID security. When this option is
enabled and a password is entered in the corresponding box, deleting the RAID will require the password to be entered. Using a wrong password will not allow the RAID to be deleted. The password can be up to 8 characters.
Basic Raid Configuration Buttons:
Apply – Save the configuration and create the RAID.
Cancel – Undo the current operation.
SATA II-to-SATA II Internal RAID Subsystem
29
Ins
tallation and Configuration Manual
To create a RAID using Basic Raid Configuration:
1. In the Configure RAID option, select the RAID Level you want for the RAID. Click
“Apply” to save the RAID configuration.
2. When a dialog box is displayed, select “Yes” to confirm creating RAID.
3. An information message will be displayed. Click “OK”.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
30
4. The RAID is created successfully. The RAID will be available to the Host/Server
immediately and a new disk device will be detected.
5. Check the new disk drive in your Host/Server.
Example: Connection via SATA
In Microsoft Windows under Device Manager, the new disk drive
(XtendLan H/W RAID5) is
displayed. Example: Connection via USB
In Microsoft Windows under Device Manager, the new disk drive
(XtendLan H/W RAID5 USB Device) is
displayed.
SATA II-to-SATA II Internal RAID Subsystem
31
Ins
tallation and Configuration Manual
Example: Connection via IEEE 1394
In Microsoft Windows under Device Manager, the new disk drive
(XtendLan H/W RAID IEEE 1394 SBP2 Device) is
displayed.
NOTE:
If your RAID subsystem’s host interface is SATA, you can create up to two RAIDs. If the SATA controller in your host system supports SATA port multiplier, the two RAIDs will be detected. For example, Silicon Image SiI3132 chip supports port multiplier.
If your RAID subsystem’s host interface is either USB or IEEE 1394, only one RAID will be detected if you create two RAIDs.
Over 2TB RAID via SATA host interface is supported only in latest OS, such as MS Vista or Windows Server 2008, which includes default SATA driver.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
32
4.2 Advanced Mode
4.2.1 SMART Information
This function will show SMART information of the disk drives if SMART function is supported by the disk drives.
NOTE: The SMART information will be shown only if a RAID is already created.
Click on a disk drive in the left pane; the SMART information will be displayed on the right pane.
SATA II-to-SATA II Internal RAID Subsystem
33
Ins
tallation and Configuration Manual
4.2.2 Email Notification
This function provides option to configure email for sending event notifications when events happen.
Email Notification Options:
SMTP Server Name – Enter the SMTP Server name or IP address SMTP Server Port – Enter the SMTP Server port number Sender – Enter the sender’s email address Recipient(s) – Enter one or more recipient email addresses Select event(s) for notification – Tick the events which you want to be
included in the list of events for email notification. When selected events happen, the email recipient(s) will receive the event notification.
Email Notification Buttons:
Load From Profile – Use this button to load a saved profile. Save To Profile – Use this button to save an existing profile. All settings will be
saved to the profile.
Apply – Use this button to apply changes to the configuration.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
34
4.2.3 Advanced Raid Configuration
This function provides option to customize RAID configuration and select disk drive members.
Advanced Raid Configuration Options:
Configure RAID – Select option whether to Create RAID or to Delete RAID.
When Create RAID is selected, the RAID Level options are displayed. When Delete RAID is selected, the list of available RAIDs that can be deleted is displayed.
Create RAID - Select the RAID Level from the list of options, and select the disk
drives in the right pane. When the minimum number of disk drives for the RAID Level has been selected, the Apply and Cancel buttons will become active and can be used.
Support Password – This option provides RAID security. When this option is
enabled and a password is entered in the corresponding box, deleting the RAID will require the password to be entered. Using a wrong password will not allow the RAID to be deleted. The password can be up to 8 characters.
Advanced Raid Configuration Buttons:
Apply – Save the configuration and create the RAID.
Cancel – Undo the current operation.
SATA II-to-SATA II Internal RAID Subsystem
35
Ins
tallation and Configuration Manual
To create a RAID using Advanced Raid Configuration:
1. In the Configure RAID option, select Create RAID.
2. Select the RAID Level you want for the RAID.
3. Select the disk drives you want to become member of the RAID.
4. If you want security for the RAID, enable Support Password and enter a password.
5. Click “Apply” to save the RAID configuration. A dialog box will be displayed.
Select “Yes” to proceed.
6. An information message will be displayed. Click “OK”.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
36
7. The RAID is created successfully. The RAID will be available to the Host/Server
immediately and a new disk device will be detected.
8. Check the new disk drive in your Host/Server.
Example: Connection via SATA
In Microsoft Windows under Device Manager, the new disk drive
(XtendLan H/W RAID5) is
displayed.
Example: Connection via USB
In Microsoft Windows under Device Manager, the new disk drive
(XtendLan H/W RAID5 USB Device) is
displayed.
SATA II-to-SATA II Internal RAID Subsystem
37
Ins
tallation and Configuration Manual
Example: Connection via IEEE 1394
In Microsoft Windows under Device Manager, the new disk
drive
(XtendLan H/W RAID IEEE 1394 SBP2 Device) is
displayed.
NOTE:
If your RAID subsystem’s host interface is SATA, you can create up to two RAIDs. If the SATA controller in your host system supports SATA port multiplier, the two RAIDs will be detected. For example, Silicon Image SiI3132 chip supports port multiplier.
If your RAID subsystem’s host interface is either USB or IEEE 1394, only one RAID will be detected if you create two RAIDs.
Over 2TB RAID via SATA host interface is supported only in latest OS, such as MS Vista or Windows Server 2008, which includes default SATA driver.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
38
4.2.4 Firmware Information
Shows information about current firmware and provides function to upgrade the firmware version.
Firmware Information – shows the Product Name, Firmware version, Manufacturer,
and Flash Number.
Firmware Upgrade Buttons:
Browse – Use this button to browse and select the firmware file. After selecting
the firmware file, the Select Firmware box will show the selected firmware file.
Update – Use this button to upgrade the selected firmware file.
SATA II-to-SATA II Internal RAID Subsystem
39
Ins
tallation and Configuration Manual
To upgrade firmware:
1. Select “Browse” and locate the firmware file.
2. Select “Update” to proceed with firmware upgrade.
3. The firmware will be upgraded. Click “OK”.
4. To reboot the RAID subsystem, uninstall the disk drive from the host system then
power cycle the RAID subsystem. The new firmware will be loaded in the RAID controller.
SATA II-to-SATA II Internal RAID Subsystem
llation and Configuration Manual
40
4.2.5 System Information
The System Information screen shows information about the RAID subsystem such as temperature, fan speed and voltage levels.
Loading...