5FORM OF THE EQUIPMENT .................................................................................................................................... 4
5.1.1 Front panel of XL-FMUX4E1T............................................................................................................................ 4
5.1.2 Front panel of XL-FMUX4E1 .............................................................................................................................. 6
6.3NOTICES FOR INSTALLATION..................................................................................................................................... 4
For a model with AC power supply, AC power (165~265VAC) is supplied to the XL-FMUX4E1
through
a becoming standard clover leaf 3-prong receptacle, located on the rear of the unit. The XL-FMUX4E1
should always be grounded through the protective earth lead of the power cable in AC installations.
For a model with DC power supply, DC +24V (18~36VDC) or DC -48V (36~72VDC) is connected
to the detachable terminal block. Please take extra caution to observe the proper polarity of the DC
when wiring the connector. The XL-FMUX4E1 should always be grounded through the protective
earth lead via the frame ground connection for DC installations.
.
Hot-line phone:
4-wire handset interface detail is shown below:
Interface MicrophoneEarphone
RJ-11 2
3
Fiber optic connector:
The standard interface is FC, TX means output, RX means input.
E1 interface:
Unbalance interface: BNC connector, OUT means transmit, IN means
receive. Balance interface: RJ-45 connector, the definition is shown below:
1 2 3 4 5 6 7 8
Function
Note: NC means “ No connection”
Pin
1
NC
23456
TX+Tx-NCNCRX+
78
RX-NC-
6 Installation and maintenance
6.1Unpacking
After the equipment arrives, unpack and check it before installation. Items to be checked are as
follows:
● The external package is in good condition or not. If it is damaged seriously, please contact our
after-sale service department immediately for solving.
● Based on the package list, verify the items one by one. If there is any serious damage on the
surface or any accessories missed, please contact the installation person or directly contact our
after-sale service department.
● Please check carefully whether the equipment type and quantity are in conformity with what you
ordered.
● Check the power supply mode.
6.2 Installation
● Fix the equipment on the 19” rack-mount.
● According to the manual, connect power supply with the power cable. Pay attention to the
power polarity.
● According to actual situation, make and connect relevant cable (2M, RS-232). Do not connect
the TX and RX optic cables wrongly.
● Connect the TX and RX optical fibers (or patch cords) to the optical RX and TX connectors in
the equipment. Do not connect the TX and RX fibers wrongly. Check whether the fiber head is
clean or not. Insert the optical fiber (or patch cords) and make sure the connection is good. (The
bending radius of optical fiber must 50mm.)
● Use a multimeter to check the power polarity and voltage is in conformity with equipment
requirements or not. This is especially recommended for 48V power supply version.
● After all installation and check, turn on the power supply switch.
● Check whether the equipment indicator light is the same as the actual situation (Refer to
relevant chapters in the manual.).
Note: When install single fiber Optic Multiplexers, you must ensure they are same TX and RX
wavelength, for example: TX:1550nm, RX:1310nm must match with TX:1310nm, RX:1550nm
6.3Notices for Installation
1) Avoid strong vibration and mechanical damage during transportation and installation.
2) Place the optical fibers reasonable. The bending radius of optical fiber must 50mm.
3) Check whether the voltage and polarity is in conformity with the marks on the rear panel before
supplying power. Otherwise, it may cause permanent damage to the equipment.
4) The optical fiber connector cannot be contaminated. Clean the fiber head with alcohol before use.
Otherwise, it may affect the transmission distance. If the optical fiber connector is connected
wrongly, it may cause more power consumption. Adjust the connector according to the actual
situation.
5) The installation position shall be easy for persons to access and transport equipment.
6) The ambient environment shall be dry, clean and good in ventilation.
7 Start Equipment
Turn the power supply switch to ON.
After supplying power, check and verify relevant indicators and alarms according to the manual.
Caution:Please turn power supply off and contact with our after-service engineer once you find
any error。
8 Fault Treatment
Before leaving factory, the equipment has been adjusted to optimal status, and all the functional
interfaces are all in the front and rear panel. Except our technicians, no one shall open the unit shell
freely. When the equipment has fault, use the stand-alone self-loop-back function to decide the fault
scope and contact us immediately.
The table below lists the common faults and alarms, the possible causes for alarms and solution, only
for reference.
Equipment Alarms and Corresponding Treatment
No Alarm
1
2
3
5
6 CH# alarm
7
Primary
Alarm
Secondary
Alarm
POWER is
on.
Red LOS
light is on.
Red LOF
light is on.
Red RAD
light is on.
Sound
alarm
Possible
Causes
Cannot supply
power.
Cannot
receive optical
signal.
Cannot
receive
normal frame
signal.
The opposite
end alarms.
Cannot
receive 2M
signals.
The local end
alarms.
The power supply is not connected well. The
polarities are reversed.
The optical fiber link is not through. There is on
optical light from the opposite end.
The receiving is not stable. Check the optical link
and equipment.
Check the opposite end.
Check the quality of fiber cable. The TX and RX
You may screen the equipment when handling
fault.
Treatment
fibers are connected in reverse or not.