XtendLan PIRCAM700L20-P7110 User Manual

Image Sensor
1/3'' Sony Effio CCD
Effective pixel
NTSC: 976(H)*494(V)
PAL: 960(H)*582(V)
Horizontal Resolution
700TVL
PIR
IR Motion Detector Sensitive Distance 5-10m
Lens
3.7mm pinhole lens
Scanning Area 4.9mm(H)*3.7mm(V)
Min
illumination
0.01lux
Electronic
Shutter
Auto
Audio
Optional, Built in Mic
S/N Ratio
≥48dB
Sync System
Internal
Video Output
1VP-p Composite Output (75Ohm/BNC)
Day/night
Color to BW
OSD Menu
No
AGC
Auto
White Balance
Auto
BLC
Auto
Power Supply
12V DC
Operating
Temperature
-10°C ~ 50 °C
Feature
1. Original 1/3'' Sony Effio CCD
2. High resolution 700TVL
3. 3.7mm pinhole lens
4. PIR Sensor hidden camera camera
Specification
XTENDLAN WIDE ANGLE PIR
PRODUCT INTRODUCTION
The p roduct i s p assive infrared d etector w ith high stabili t y. I t h as adopted advanced t e chnolog y in signal processing and provided superhigh detection ability and anti error alarm. The d etector will detect m ovement o f human automatically when intruder passes through the detection area, and i t w ill send out alarm s ignal t o alarm host i f t here is movement. The product is suitable for the safety of residential house, villas, factories, markets, warehouses, office building etc.
PRODUCT PROFILE
Notes:LED indicator should be kept over the lens when installation
Wire Exit Anti-dismantle Switch Terminal Block Relay
Infrared Sensor LED Jumper
MAIN FEATURE
Intelligent logic control, anti false alarm efficiently
Auto temperature compensation Pulse count adjustment Anti white light interference Anti RF interference (20V/m-1GHz)
Fresnel lens Wall/ceiling installation SMT design adopted
Alarm output N.C. / N.O. Optional
Relay Jumper
LED Indicator
Thermistor Resistance
Lens
Pulse Jumper
TECHNICAL SPECIFICATION
Operating voltage:DC 9V 16V Current comsuption: 18mA(DC12V) Detecting distance: 12m Detecting angle: 110 Self-testing time: 60S or so Operating temperature: -10 ~+50
Alarm indicator: red LED
Alarm output:N.C. or N.O., DC28V,100mA Anti dismantle output: N.C., DC28V 100mA Range of coverage: 11 distance, 8 middle, 5 vicinities Sensor: dual element infrared sensor Operating temperature: -10 to +50 Environment humidity: 95% RH (no congelation) Anti RF interference: 10MHz 1GHz 20V/m Installation mode: wall mounted or hanged in corner Installation height: 1.7 to 2.5m (2.2m is Proposed) Outline Size: 59L*39.5W*107H mm
INSTALLATION
1. Installation at the out door,place with pets, air-condition
nearb y, d irect sunshine, h eat source a nd under t he rotating objects should be avoided.
2. Surface of installation should be firm with no vibration.
3. Installing the detector in the place where intruder passes
easily.
INSTALLATION STEP
1. Screw the detector bottom off, then open the detector.
2. Screw the PCB off, and remove the PCB.
3. Drill a wire hole in the rear housing.
4. Install the rear housing on the suitable position.
5. Connect the terminal block.
(Referring to the following figture)
TERMINAL BLOCK FIGTURE
+12V DV ANODE GND DV CATHODE ALARM ALARM OUTPUT PORT TAMPER ANTI-TEMPER OUTPUT PORT
OPERATING INSTRUCTION
Function Setting
1. Relay Jumper: Short N.C. or N.O. to set the state of alarm
output. You should choose different alarm output in accordance with alarm host. Short 1&2: N.O. Short 2&3: N.C.
2. Pulse Jumper: You can adjust the sensitivity and anti RF
interference by choosing the Pulse Jumper.
Short 1&2: class 1 pulse, the sensitivity and anti RF
XTENDLAN WIDE ANGLE PIR
interference is general, adapt to general environment. Short 2&3: class 2 pulse, the sensitivity is highest, and anti RF interference is high, adapt to the environment with strong RF interference.
Shut off: class 3 pulse, the sensitivity is low, and the anti RF interference is highest, adapt to the environment with exceeding RF interference.
3. LED Jumper: Control LED indicator, no effect of detector
normal work. Short 1&2: set LED ON Short 2&3: set LED OFF LED can be shut off for concealment of the detector after Test.
Product testing
Turning on power and LED indicator on, the detector comes into the state of self-check, it takes about 60s, after that it is in the state of normal work. Conner should walk parallel with the wall installed detector in the testing area. LED lighting means the detector is in the state of alarm.
NOTICE
1. Please install and use the detector according to this
manual, don't touch the surface of sensor for avoiding affecting the sensitivity of the detector. Please shut off power and then clean the sensor by soft cloth with little alcohol if cleaning needed.
2. The product can reduce accident but may not perform as
expected. T he user is advised t o take all necessary precautions for his/her s afety and t he protection o f his/her property.
3. In order to ensure it can work normally, the power should
be kept to supply and get on walking test periodically, once a week is better.
JUMPER SETTING FIGURE
LED J UMPER
RE LAY JUM PE R
PU LSE JUM PE R
1 2 3
1 2 3
1 2 3
Detecting Area View
Planform
Side View