Read this manual carefully before using the product, and keep it well for future use.
1. Parts and Functions
Speaker
88
11020
Talk volume
controller
Tone volume
controller
Microphone
Unlock button
Talk button
Unlock 2nd/Intercom button
Indicator
Key functions
SpeakerSend out voice from the visitor.
MicrophoneReceive voice from the user.
Unlock button
Talk buttonPress to communicate hands free with visitor
Unlock 2nd button/
Intercom button
IndicatorPower and working indicator.
Tone volume contronller
Talk volume contronller
Press to release the door.
During calling/talking state, press Unlock 2nd button to release the second door;
In standby mode, press Call button to activate the intercom
call.
Adjust the tone volume.
Adjust the talk volume.
Side View
2. Terminal Descriptions
ON
1 2 3
ONDIP
1 2 3 4 5 6
DIP2
L2 L1
L1, L2
L1,L2:Bus terminal.
DIP1(Bit1~6):Used to User Code setting.
DIP2(Bit1~3):Used to Slave Monitor Address or Extended Address setting.
3. Unit Mounting
1). Fix 2 screws to the wall at a appropriate height;
2). Connect the system correctly;
3). Attach the audio phone to the bracket.
DIP1
4. Operation Instructions
1) Door release function: When visitor calls from outdoor station, the monitor rings,
press Talk button to talk with the visitor, then press the Unlock button to open the door.
If the system connect 2 locks, press Unlock 2nd button to open the second door.
2) Intercom call: When the monitor is in standby mode, press Unlock 2nd button/
Intercom button to activate the intercom call, all monitors connected to the system will
ring at the same time. whichever Monitor answers the call, conversation is started. and
the other monitors will stop ringing at the same time.(note that the user code must be
the same for all monitors to activate the intercom call function)
5. Setup Instructions
5.1 User Code Setting(DIP1 to set it)
In the DT system, every apartment must have a unique identication called User Code.
The DIP1 switches are used to congure the User Code for each Monitor.
• Bit-1~5 of DIP1 are used to User Code setting. The value is from 1 to 32, which
have 32 different codes for 32 apartments.
• Bit-6 of DIP1 is used to video match.
Bit stateUser CodeBit stateUser CodeBit stateUser Code
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=1
Code=2
Code=3
Code=4
Code=5
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=12
Code=13
Code=14
Code=15
Code=16
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=23
Code=24
Code=25
Code=26
Code=27
Bit stateUser CodeBit stateUser CodeBit stateUser Code
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=6
Code=7
Code=8
Code=9
Code=10
Code=11
ON
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
ON
1 2 3 4 5 6
Code=17
Code=18
Code=19
Code=20
Code=21
Code=22
ON
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=28
Code=29
Code=30
Code=31
Code=32
5.2 Slave Address Or Extended Address Setting(DIP2 to set it)
When multi Monitors are installed in one apartment, these Monitors have to use the
same User Code setting, and the Master/Slave mode should be set on the Monitor.
• Bit-1~2 of DIP2 are used to slave address or extended address setting.
• Bit-3 of DIP2 is used to monitor matched setting, When Bit-3 set to ON / OFF, there
are different usages.
5.2.1 When Bit-3 of DIP2 set to OFF, the Bit-1~2 of DIP2 are used to master/slave
address setting:
DIP2 stateMaster/Slave type
ON
1 2 3
ON
1 2 3
ON
1 2 3
ON
1 2 3
Master monitor
Slave monitor 1
Slave monitor 2
Slave monitor 3
5.2.2 When Bit-3 of DIP2 set to ON, the Bit-1~2 of DIP2 and Bit-1~5 of DIP1 are
used to extended address setting:
DIP2 stateDIP1 stateUser Code
ON
1 2 3
ON
1 2 3
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=1
Code=2
.........
ON
1 2 3
ON
1 2 3
ON
1 2 3
ON
1 2 3
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=31
Code=32
Code=33
Code=34
.........
ON
1 2 3
ON
1 2 3
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=63
Code=64
DIP2 stateDIP1 stateUser Code
ON
1 2 3
ON
1 2 3
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=65
Code=66
.........
ON
1 2 3
ON
1 2 3
ON
1 2 3
ON
1 2 3
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=95
Code=96
Code=97
Code=98
.........
ON
1 2 3
ON
1 2 3
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=127
Code=128
5.3 Ring Tone Setting
1). There are four groups ring tones to choose for you:
Group nameItems
Group1
Group2
Group3
Group4
Door StationDINGDONG
Intercom CallTELEPHONE_RING
Door StationJINGLE_DELL
Intercom CallCARMAN
Door StationHAPPY_BIRTHDAY
Intercom CallSONATINE
Door StationDOREME
Intercom CallRHYTHM_OF_THE
Songs
2). Press and hold Talk button in standby mode to enter the state of ring tone setting,
and then each time you press Unlock 2nd button to replace a group of ring tones. Four
groups ring tones cycle:
Group1 Group2 Group3 Group4.
3). Press Talk button to exit the setting.
press Unlock 2ndpress Unlock 2ndpress Unlock 2nd
press Unlock 2nd
6. Specication
●Power Supply: DC24V
●Power Consumption: standby 16mA,working 56mA
●Working Temperature: -15ºC ~ +55ºC;
●Wiring: 2 wires, non-polarity
●Dimension: 88(H)X110(W)X20(D)mm
The design and specications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.