XtendLan DPP-D201 User Manual

User Manual
Audio Phone
Read this manual carefully before using the product, and keep it well for future use.
1 2
8888
DPP-D201
1. Parts and Functions
187
33.2
150
97.1
2 1
8888
Handset
7 segment LED
Menu button
Cancel button
Unlock 2nd button
Speaker
Handset line
Side View
Up button
Down button
Unlock button
7 segment LED Display setting informations
Handset Pick up to communicate with visitor
Hand line Connect handset with monitor
Unlock button Press to release the door
Unlock 2nd button Press to release the second door
Up button Press to move up or increase the value
Down button Press to move down or decrease the value
Menu button Press and hold for 2s to open the setting menu shortcuts.
Cancel button Press to cancel the operations
Speaker Send out vioce from the visitor
Key functions
2. Operation Instructions
3. Setup Instructions
1) Door opening function:When visitor calls from outdoor station, the monitor rings, pick up handset to talk with the visitor, then press the Unlock button to open the door.If the system connect 2 locks,press Unlock 2nd button to open the second door.
2) Entrance monitoring: Pick up handset in standby mode,the LED will be shown a scroll information "Intr Call",press Up button or Down button to stop the scroll,and the LED show "ds-x"(x=1~4,refer to part 3-Numbers of door station),it means that the monitor select "x" door station to mionitor.Press Up / Down button to increse/decrese the value,then press Menu button to activate the monitoring.
3) Inner call: Use Up / Down button to select "-ALL" item on LED,then press Menu button to activate the inner call,all monitors connected to the system will ring at the same time.Pick up any monitor,the others will stop ringing immediately.(note that the user code must be the same for all monitors to activate the inner call function)
4) Intercom call:Use Up / Down button to select "C-xx" (xx=00~31,refer to part3­Numbers of indoor monitor)item on LED,then press Up / Down button to increse/ decrese the value,and press Menu button to conrm the intercom calling.(note that the user code must be different for all monitors to activate the intercom call function)
Press Menu button and hold for 2s in standby mode,the LED will be shown a scroll information "User Set-",press Up button or Down button to stop the scroll,and the LED show the setting items.Press Menu button to select next setting items.
Setting
Item
L E D state
Description Default
Door station
call tone
1-xx
Set the ring tone calling from outdoor station.Total 12 pieces ring tones can be selected(xx=01~12),press Up button or Down button to increse/decrese the value,settings will be performed immediately.
02
Intercom
call tone
2-xx
Set the ring tone callin g fr o m i n tercom call or inner call.Total 12 pieces ring tones can be selected(xx=01~12),press Up / Down button to increse/decrese the value,settings will be performed immediately.
12
Setting
Item
L E D state
Description Default
Ring volume 3-rx
Set volume for call tone,rang from 0~9.
6
Speaker volume 4-Lx
Set volume for speaker,adjust the voice from outdoor,rang from 0~9.
6
Microphone
volume
5-tx
Set volume for microphone,adjust the voice from user,rang from 0~9.
6
Numbers of door
station
6-0x
Maximum 4 door stations can be selected,this item is used to set the numbers of door station that can be surveilled by indoor monitor.refer to part 2 ->Entrance Monitoring.
1
Numbers of
indoor monitor
7-xx
Maximum 32 indoor monitors can be selected,this item is used to set the numbers of indoor monitor that can be selected to intercom.refer to part 2
->Intercom call.
04
Keypad sensitivity 8-sx
Rang from 0~2,The larger you set the value,the stronger it will be,"0"-slow,"1"-normal,"2"-fast.
1
Slave adress
setting for monitor
9-dx
Rang from 0~3,"0"-master monitor,"1~3"-slave monitor.
0
Restore to default
setting
9-FS
The restore to default function allows the user to recover the settings to factory setting.Select "9­FS" item on LED,then press Up button,"yES­"will be asked,press Up button again,the LED will be shown"SUCC",that means settings are restored to default.
-
4. Specication
●Power Supply: DC24V
●Power Consumption: standby 20mA,working 70mA
●7 segment LED: 4 digits dynamic
●Wiring: 2 wires, non-polarity
●Dimension: 187(H)X97(W)X33(D)mm
The design and speci cations can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.
Loading...