Setting
Item
L E D
state
Description Default
Ring volume 3-rx
Set volume for call tone,rang from 0~9.
6
Speaker volume 4-Lx
Set volume for speaker,adjust the voice from
outdoor,rang from 0~9.
6
Microphone
volume
5-tx
Set volume for microphone,adjust the voice from
user,rang from 0~9.
6
Numbers of door
station
6-0x
Maximum 4 door stations can be selected,this
item is used to set the numbers of door station
that can be surveilled by indoor monitor.refer to
part 2 ->Entrance Monitoring.
1
Numbers of
indoor monitor
7-xx
Maximum 32 indoor monitors can be selected,this
item is used to set the numbers of indoor monitor
that can be selected to intercom.refer to part 2
->Intercom call.
04
Keypad sensitivity 8-sx
Rang from 0~2,The larger you set the value,the
stronger it will be,"0"-slow,"1"-normal,"2"-fast.
1
Slave adress
setting for monitor
9-dx
Rang from 0~3,"0"-master monitor,"1~3"-slave
monitor.
0
Restore to default
setting
9-FS
The restore to default function allows the user to
recover the settings to factory setting.Select "9FS" item on LED,then press Up button,"yES"will be asked,press Up button again,the LED
will be shown"SUCC",that means settings are
restored to default.
-
4. Specication
●Power Supply: DC24V
●Power Consumption: standby 20mA,working 70mA
●7 segment LED: 4 digits dynamic
●Wiring: 2 wires, non-polarity
●Dimension: 187(H)X97(W)X33(D)mm
The design and speci cations can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.