XtendLan DPK-W100 User Manual

DPK-W100
Wireless colour video doorphone
User manual
Contents
Features……………………………………… …………………………… 1 Components checklist……………………………………………………1
Products
description………………………………………………………2
Cradle………………… ………………………… ………………… ……… 3
Charger fixing
procedure…………………………………………………4
Button
description…………………………………………………………5
ID NO.
display………………………… ……… ………… ……… ………5
Coding………………………………………………………………………5
Receive
code………………………………………………………………6
Code
clearing………………………………………………………………7
Setting of ring
tone………………………………………………………7
B
rightness adjustment
…………………………………………………8
Surveillance…………………………………………………………………8
Basic
operation ……………………………………………………………9
Night-vision operation………… ………………………………………11
Unlocking
time
setting…………………………………………………11
Installation……………… ……… ……… ………… ……………………12
Lock
connection…………………………………………………………13
Technical
specifications … … … … … … … … … … … … … … … … 14
Trouble
shooting…………………………………………………… 15
Propagation
of radio waves… … … … … … … … … … … … … … 16
Battery
specifications … … … … … … … … … … … … … … … … … 16
Notes… … … ………………… … … … … … … … … … … … … ………… 17
1
Features
Wireless colour video doorphone
Mobile handset with 2.4 TFT-LCD screen
Identify and screen callers
Unlock doors remotely for visitors
Range in free field 300 meters
12 selectable ringtones
Handset to handset communication (Paging)
Infra red camera in outside call station to see callers at night
Expand to a 2-way system by adding a call station & handset
Rechargeable battery via mini USB interface
Standby status 72 hours
Easy to install
Built-in surveillance mode function
Components checklist
Package contents:
one outdoor camera/call station, one handset monitor (include Li-ion battery), one power adaptor for call station (DC5V, 1A), one charger for handset monitor (DC4.5V, 0.8A), cradle and some screws for fixing the call station on the wall.
Components description:
Handset monitor
Charger
Call station
Power adaptor
Cradle
2
Products description
Speaker
2.4G antenna
ON/OFF
Status
indicator
2.4 inch LCD
Unlock
Monitor
Brightness+
Brightness-
Code clearing
Reset
Answer
Microphone
Microphone
Camera
Speaker
Status indicator
Call
3
Cradle
1.Fixed on the desk 2.Fixed on the wall
4
Charger fixing procedure
(3)
(5)
(4)
(6)
5
Button description
“ON/OFF”button: It is used to power on/power off of wireless
handset monitor. ”: Is used to:a) answer the calls when visitors press the call button in outdoor call station; b) as the confirmation button when performing the ringing tone selection; c) as the coding button when carrying out coding between the components. ”: In standby status, it is used to enter the menus of ringing tone selections; in talk status, it is used to increase brightness.
”: In talk status, it is used for reducing brightness. “ ”: Is used to switch on the camera in outdoor call station in order
to monitor outside in standby status.
“ ”: It is used to operate an electric lock release when the monitor is in the “talk” status. “ ”:Is used to clear the previous code .After this operation ,you
should carry-out the coding procedure between or among the call stations and handsets again. :Make it return to the default status .After this operation ,then it will enter the OFF status.
ID NO. display
Press the “ON/OFF” button when the handset monitor is in OFF status, until the 2.4 inch TFT-LCD displays Welcome” and sounds
two “Di Di” tones, then release the button. It means that the handset
monitor is entering into the ON status. Press the “ON/OFF” button when the handset monitor is in ON status, then the 2.4 inch TFT-LCD will show “Goodbye”and create two “Di Di” tones, then release the button. This indicates that the handset monitor is entering into OFF status. When the outdoor camera is powered, a single “Di” tone indicates that call station 1 is being viewed. If a dual “Di Di” tone is sounded this confirms that the call station 2 is being viewed.
Coding
1).Press the and buttons at the same time when the handset monitor is in power-on status, until the screen shows the
6
letters “Configure code”, then release the buttons and it will enter the coding status.
2).At this time, press the call button in outdoor camera when it is in standby status until the red indicator remains lit and creates two sounds “Di Di , then release the button and it will enter the coding status.
3)If the handset monitor shows the letters “successed” within 8s, the coding is successful and the call station and handset monitor have successfully paired; at this time, the outdoor call station will create 3 sounds “Di Di Di”. If the handset monitor shows the letters "failed" within 8S, then it means that the coding is failed and the outdoor station will have no response. Note: After successful coding, then the outdoor camera and handset
monitor are the 1st outdoor camera and 1st handset monitor respectively; if coding is failed, you should do the coding again.
Receive code
(only required when adding one more call station or one more handset monitor.) Adding one more handset monitor :
1).Press the and buttons at the same time, when the 1st handset monitor is in ON status until the screen shows “transmit code”, then release the buttons and enter the “transmit code” status.
2).On the additional handset(2nd) after “transmit code” is displayed on the 1st handset, press the “ ” and “ ” buttons at the same time
on the 2nd handset when it is in ON status until the screen shows “receive code, then release the buttons and enter the “receive code” status, then press the button at this time in 2nd handset monitor. If it shows “successed” on the handset, it means that the coding has been successful.
Adding one more outdoor call station :
1).Press the “ ” and “ ” buttons when the handset is in the ON status until the screen shows “transmit code”, then release the
buttons and enter the “transmit codestatus.
2).Then press and hold the call button in outdoor call station until
7
you hear the two “Di Di” tones. Then release the call button in outdoor call station (Do not release until you hear the two Di Di tones ). Then
press the “ ” button in the handset at this time. If it shows “successed” on the handset, the coding has been successful.
Adding one more outdoor call station and one more handset monitor:
1).Press the “ ” and “ ” button when the 1st handset monitor is in ON status until the screen shows “transmit code”, then release the buttons and enter the “transmit code” status .
2.Then press the and buttons at the same time when the 2nd handset monitor is in ON status until the screen shows “receive code”, then release the buttons and enter the “receive code” status. Press the button at this time on 2nd handset monitor. If it shows “successed” on the handset, then it means that the coding is successful.
3).On the 2nd handset, press and hold the “ ” and “ ” buttons when the 2nd handset monitor is in ON status until the screen shows
“transmit code”, then release the buttons and enter the “transmit code” status.
4).During this time, press the call button in 2nd outdoor call station until you hear two DiDi tones. Then release the call button in the outdoor call station(Do not release the button until you hear the two DiDi tones). If it shows “successed” in the handset, it means that the coding has been successful.
5).If all the coding is successful, press the button in the 1st handset monitor to return to the standby status .
Code clearing
Handset monitor: Keep pressing the and buttons when
the handset monitor is in OFF status. At the same time, then press the ON/OFF button in the handset monitor together until the screen displays “clear code ” and creates one “Di” sound (still keep pressing the “ ” and buttons when you press the ON/OFF button). This means that code clearing is successful. It will be in OFF status after releasing the buttons.
8
Outdoor call station:
Press the code-clear button (the code-clear button is in the back of outdoor call station, for details, please refer to the
lock
connection section. Its icon is . ) and it creates one “Di” sound. This means that code clearing is successful.
Note: Be careful when doing this, as it will cause a malfunction. You will then need to carry out the coding procedure of outdoor call station and handset again. See above for CODING and RECEIVE CODE sections.
Setting of ring tone
Press the “ (ring tone sele ction button) when the handset monitor is in standby stat us, until a ring tone sounds, the monitor is now in r ing tone selection mode. At th is time, press the button successively to choose anot her tone(A tot al 12 ring tones are available for selection ). After choosing your favorite tone, press the “ b utton to confirm, or w ait until the playing tone is ended, then it w ill auto -exit.
Adjusting brightness
There are 6 levels for bright ness adjustment. Press the button when the handset monitor is in talk status or surveillance function(For details, please kindly refer to the BASIC OPERATION and SURVEILLANCE), then the brightness level will become higher. At this time, it will show “Val 0i” on the handset monitor (“ i ”is to indicate the brightness level). When the brightness is adjusted up to maximum level, if you press this button again, then it will be invalid. Press the button when the handset monitor is in talk status or surveillance status, then the brightness level will become lower. At this time, it will show “Val 0i” on the handset monitor (“ i ” is to indicate the brightness level). When the brightness is adjusted to minimum level, if you press this button again, then it will be invalid.
Surveillance
One to one intercom:
1).Press the “ ” button when the handset monitor is in standby
9
status, then the screen will display “monitoring 01”.
2).If the outdoor call station receives a signal within 1S, then it will display the 1st outdoor station; if not receiving the signal within 4S, then it will auto-exit the monitor status.
3).In monitor status, press the button again, then it will exit the monitoring of 1st outdoor call station. The monitor time is 60S. After 60S, it will auto-exit the monitor status.
One to two or two to two system:
1)Press the button when the handset monitor is in standby status, then it will monitor the 1st outdoor station (It will display monitoring 01); press this “ ” button again, then it will monitor the 2nd outdoor station (It will display“monitoring 02”); press the ” button in third time, it will auto-exit the monitoring status.
2)If receiving a signal within 1S, then it will monitor the outdoor station; if not receiving the signal within 4S, then it will auto-exit the monitor status.
3)In standby status, press the “ ” button to start or end the monitoring of outdoor stations. After 60S, it will auto-exit the status.
Basic operation
one to one intercom:
1).In standby status, when a visitor presses the call button on call station, then the power indicator will still light.
2).a.If not receiving a response signal within 4S, then it will sound “Di Di Di Di”, and it will end the call status and return to the standby status.
b.If receiving a response signal, the handset will display Talking”and the outdoor station will still sound “Du Du”, then the power indicators of handset/s will light and play the selected ring tone/s; meanwhile the TFT-LCD will display the visitors image.
3).a.If no one answers the call, the call will last 60S and return to the standby status.
b.If some one presses the buttons, then it will stop playing the ring tone and enter the talk status (The indicators in handset monitors will turn from red to green and stay lit), the talk time is
10
120S.
4).In the process of talking, pressing the “ ” button will operate the relay at the call station which can be connected to operate an electric lock release and allow the visitors enter, the monitor will display “unlock” (If visibility is poor, pressing the button will activate the night-visiton of outdoor camera ).
5).In the process of talking, the user can press the button again to end the communication, and then handset monitor will enter the standby status after sounding two “Du Du” tones.
One to two intercom:
1)In standby status, when the visitors press the call button on call station, then the power indicators will light.
2).a.If not receiving a response signal within 4S, then it will sound “Di Di Di Di, and end the call status and return to the standby status.
b. If receiving a response signal from any handset monitors, then the handset will display Talking” and the outdoor call station will still sound “Du Du”. Then the power indicators of handset will remain lit and play the selected ring tone; meanwhile the TFT-LCD will display the visitors image.
3).a.If no one answers the call, the call will last 60S and return to the standby status.
b. If some one presses the “ ” button from any handsets, then it will stop playing the ringtone and enter the talk status (the indicator in handset will turn from red to green and remain lit), the talk time is 120S, while the 2nd handset will return back to standby status after
creating one “ Di ” sound.
4).In the process of talking, pressing the button will operate the relay and allow the visitors to enter, the monitor will display “unlock” ( pressing the button will activate the night-vision of outdoor camera).
5).In the process of talking, the user can press the “ button again to end the communication, and then it will enter the standby status
after sounding two “Du Du” tones.
11
Handset intercom (Paging):
1).In standby status, if the user presses the in one handset monitor, then the red indicators will light and enter the call status. The screen will display“ Talking”.
2).a.If there is no response signal with 4S from called handset monitor, after 4 “Di Di Di Di” tones, the handset will exit the callstatus and return to standby status.
b.If receiving a response signal with 4S from the called handset monitor, then the calling handset monitor will play the selected ring tone, then the called handset will display “Talking” and play its selected ring tone and the indicator light will remain lit.
3). a.If some one answers the call from called handset monitor, the call will last 60S and enter the standby status.
b. If some one answers the call from called handset monitor, then it will stop playing the ring tone and enter the Talking” status (the indicators in both handset monitors will turn from red to green and remain lit), the talk time is 120S.
c.Meanwhile, if pressing the button in calling handset monitor, then it will end the call and enter into the standby status.
4).In the process of talking, the user can press the “ ” button again in any handset monitors to end the communication, then it will enter the standby status after hearing two “Du Du”. Note: If the handset monitor is short of power, then it will indicate the user to charge the battery in handset monitor.
Night-vision operation
1).When the handset is in talking status, press the button to activate the night-vision of outdoor camera.
2).When the handset is in surveillance status, press the button to activate the night-vision of outdoor camera.
Unlocking time setting
1).The 1st unlocking time is 1.8S (In default status, this is the 1st unlocking method). With power disconnected from the call station, press and hold the call button in outdoor call station, at this time connect the power to call station, when the unit sounds a single “Di”
12
tone , release the call button and the unlocking time will now be set at 1.8 seconds
2).The 2nd unlocking time is 4S. With power disconnected, press and hold the call button on call station, and connect power to this call station. When you hear two “Di Di” tones, release the call button and the unlocking period will be set at 4 seconds.
3). The 3rd unlocking time is 8S. With power disconnected, press and hold the call button on call station, and connect power to the call station. When you hear three “Di Di Di” tones, release the call button and the unlocking period will be set at 8 seconds. Note: The users can only unlock for the visitors during the talking and communication mode. In communication status, if either part is powered-off, then the other
will return back to standby status after one “Di” sound.
Installation
Panel
Screws
Back
box
Step 1: Install the back box Step 2: Install panel
1).Release the call station from back box by removing the locking screw under the front edge of the unit
2).Drill proper wire-through holes according to the mounting units.
3).Use four screws to fix the installation panel on the wall.
4).Connect the cables from wire-through holes and square holes of rear panel in the call station. (When an electric lock is not being connected , any unused cables or terminals should be protected and insulated to avoid the possibility of short circuits)
5).Use screws to fix the door station on the rear installation panel.
13
Lock connection
1).Power -on unlocking diagram
DC5V Unlock in put
Unlock relay out pu t
+ - KB NC C NO
1 2 3 4 5 6
AC90~264V
50/60HZ
Unlock
adaptor
DC12V/3A
+
-
Input: AC90~264V Output DC5V/1A
Power
adaptor
Lock in terface
Power on unlock
Electronic lock
EX IT
2).Power -off unlocking di agram
DC5V
Exit input Un lock relay output
AC90~264V 50/60hz
+ - KB NC C NO
1 2 3 4 5 6
Power
adapt or
DC12V /3A
+
-
Input AC90~26 4V
Output DC5V/1A
power
adaptor
Lock in terface
Power of f
unlock
Magneti c
lock
EX IT
14
Technical specifications
Door Station
Image Sensor
1/4" CMOS
Min. Illumination
0 Lu (IR on)
Power
DC5V/1A
Current
20mA~30mA (standby), 300mA (operation)
Audio Input
12-digits digital audio signal, DAC interface, 8Kbps sampling speed rate
Image Compression
MJPEG compression
Transmission Power
16~20dBm
Ringing tone
12 options selectable
Dimension
127mm(H) 95mm(W) 37mm(D)
Weight
150g
Monitor
Screen
2.4" TFT LCD
Effective Pixels
320 240
Power Source
DC4.5V/0.8A (rechargeable battery
operated)
Battery Charging Time
For the first time, it is 7~10 hours; Later around 4 hours
USB port
For battery charge
Current
20mA~30mA/3.7V (standby), 250mA (Operation)
Receiving Sensitivity
-90dBm
Dimensions
118mm(H) 77mm(W) 19mm(D)
Weight
150g
15
Trouble shooting
Malfunction
Checking
Debug
Will not power on
Check by pressing the ON/OFF button
Press the ON/OFF button fully
Check whether the power of lion battery is enough or not
Charge the battery
Check the connection of power adaptor
Connect to the power adaptor
Battery not charging
Check whether the socket in power adaptor is plugged into the
Mini-USB
charging interface
Re-connect the socket and Mini-USB charging interface
Check whether the power adaptor is plugged into the AC110~240V correctly
Plug the power adaptor into AC110~240V socket
Cannot page or talk between two handsets
Check the coding between two handsets or two call stations
Clear the existing codes and re-code between two handsets or two call stations
Images is flashing
Check whether the handset/s or callstations are located close interfering equipment such as TV sets or microwave ovens wireless router,etc
Keep handsets far away from the interfering equipments
No signal in the handset monitors
Check the connection with the power supply
Connect the power
supply
Check the distance between handset monitor and outdoor camera
Adjust the outdoor camera and handset monitor into proper distance
Check whether there is nearby
interfering electrical equipment such as microwave oven or wireless routers, etc
Keep away from strong magnetic,radio or electrical fields
16
Propagation of radio waves
The radio coverage quality, and therefore the performance of the
doorphone, may be altered by obstacles located between the door
station and the interior handset unit:
walls, partitions, slabs, armoured doors or lift shaft comprising
metallic components.
(Furthermore, radio coverage may also be affected by electrical or
electromagnetic interference).
It is important to test the radio range on the installation site.
Plasterboard and wood
Concrete and building blocks
10% to 30% reduction
50% to 70% reduction
Brick
30% to 50% reduction
Metal and metal cladding
(e.g. armoured door)
70% to 90% reduction
Battery specifications:
Battery
Typ e
Standby time
Cha rging limited voltag e
3.7V,1050 mAh
Li-ion battery
72hour
4.2V
The above marked time is in the specific situation and atmosphere
Use the authorized charger only Do not dis assemble the batteries Do not short -circuit the batterie s Do not expose the batt eries to extreme hear, f ire or water
17
Notes
1).Handset monitors should be situated away from heat sources and water.
2).Products should be opened only by the professional personnel. If
there is a malfunction please contact us or our agents.
3).Handset monitors should be located where there is a good ventilation, dry, dustless and not in direct sunlight. Dont use the
chemical impregnated or wet cloth to clean the products. Clean, soft, dry cloth can be used to clean the products.
4).Please install the products according to this instruction manual to avoid of damaging to the products.
Loading...