XtendLan DPC-D248-R, DPC-D248-FR User Manual

DPC-D248-R DPC-D248-FR
RF CARD
RF CARD
English
User Manual
2-Wire Video Outdoor Station
Contents
6.Unlock Operations ............................................................................................... 10
7.ID Setting of Door Station .................................................................................... 10
8. Precaustions ....................................................................................................... 11
9. Specications ..................................................................................................... 11
10. Cables Requirements ....................................................................................... 12
Side View
Mounting box
ID card window
Rainy Cover
Camera Lens
Speaker
Nameplate Call Button
Microphone
93 mm
182 mm
Night Light
RF CARD
ID card window
RF CARD
30 mm
220 mm
120 mm
RF CARD
Camera Lens
Speaker
Nameplate
Call Button
Microphone
Night Light
Screws for panel mounting
RF CARD
1.Parts and Functions
2.Terminal Descriptions
1 2 3
Lock Control Jumper
BUS
PL
S+
S-
Main Connect Port
-1-
3.Door Station Mounting
1 2
43
Drill holes in the wall to match the size of screws and attach the rainy cover to the wall.
Attach the panel to the rainy cover Use the screwdriver and the screw
to fix the panel
Connect the cable correctly
DT601/ID Mounting
-2-
Lock Control Jumper:
To select the lock type.
Main Connect Port:
To connect the bus line and the electronic locks.
•BUS: Connect to the bus line, no polarity.
PL: External lock power input, connect to the power positive(power +).
S+: Lock power(+) output.
S-: Lock power(-) output, connect to the power(-) input of locks(only when using the door station to power the locks, if using the external power supply for the locks, the S- will not be connected).
Mounting
1 2
43
Drill a hole in the wall to match the size of the mounting box and attach to the wall.
Attach the panel to the mounting box and use screws supplied to fix the panel
Connect the cable correctly
Placing Name Label
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
-3-
Use a screwdriver to unscrew the screw, and cock the host , then Placing Name Label.
4. System Wiring and Electric Lock Connection
Basic Connection
AC~
monitor
DPS PS4
-
+
L1 L2 PL S+ S-
-4-
Electric Lock Connection
Door Lock Controlled with Internal Power
Note:
1. Electronic lock of Power-on-to-unlock type should be used.
2. The door lock is limited to 12V, and holding current must be less than 250mA.
3. The door lock control is not timed from Exit Button(EB).
4. The
Unlock Mode
Parameter of Monitor
must be set to 0 (by default).
EB
*
LOCK
BUS PL S
+
S-
Jumper position in 2-3
1 2 3
Unlock parameter setting(set on monitor)
LOCK
Take off the Jumper
POWER SUPPLY
BUS PL S
+
S-
1.Touch item on main
menu page.
2.Touch the screen anywhere and hold for 2s.
3.Touch Installer setup item
4.A digital keypad and setting
instructions will be showed.
Manual Monitor
Monitor
Memory Playback
Album
User Setup
09/30/2010 Thu.16:41
Close
Intercom
Multimedia
About
?
H/W : --- a1.3 S/W: V17.11.418.00 Local addr: --­Unlock timing: --­Video standard: ­UI-CODE: --­MCM-VER.: --­Updated: ---
Home
Installer setup
Caliber TouchScreen
Code Number:[----]
[0010]#:Remove all remote control [0011]#:Add remote control
[8000]#:Set as master unit 0 [8001]#:Set as slaver unit 1 [8002]#:Set as slaver unit 2 [8003]#:Set as slaver unit 3 [8004]#:Set as guard unit [8005]#:Set as not guard unit [8006]#:Panel on as slaver unit called [8007]#:Panel off as slaver unit called [8008]#:Date format:MM/DD/YYYY [8009]#:Date format:DD/MM/YYYY [8010]#:Set lock mode to 0 [8011]#:Set lock mode to 1
[8021]~[8029] #Set the lock time of 1~9s
Multi language settings:
---
1
4
7
8
0
9
6
5
2
3
Cancel
Installation settings:
-5-
Door Lock Controlled with Dry Contact
Note:
1. The external power supply must be used according to the lock.
2. The inside relay contact is restricted to AC or DC 24V/1A.
3. The jumper must be taken off before connecting.
4. Setup the
Unlock Mode
of Monitor for
different lock types.
Power-on-to-unlock type:Unlock Mode=0 (by default)
Power-off-to-unlock type:Unlock Mode=1
Note:
1.must connect DT601(F)/ID correctly before setting.
2.the parameter will be saved in DT601(F)/ID automatically,so you need only set on one monitor.
3.the above diagram is t for icon menu series monitors only, to text menu series monitors,please refer to
the corresponding user manual.
-6-
Multi Door Stations Connection
85~260VAC
DT-DPS
PS5
monitors
DIP=on,off,off
DBC4S
A B C D
OFF
ON
Impedance
switch
1# Camera2# Camera3# Camera4# Camera
L1 L2 PL S+ S-L1 L2 PL S+ S-
L1 L2 PL S+ S-
L1 L2 PL S+ S-
(Device Address:3) (Device Address:2) (Device Address:1) (Device Address:0)
Basic IN-OUT Wiring Mode
Multi Monitors Connection
Code=0, DIP-6=off
1 2 3 4 5 6
ON
Code=15, DIP-6=on
1 2 3 4 5 6
ON
Code=14, DIP-6=off
1 2 3 4 5 6
ON
monitor
Code=1, DIP-6=off
1 2 3 4 5 6
ON
monitor
monitormonitor
85~260AC
DPS
PS5
RF CARD
(Device Address:0)
With DBC4S Wiring Mode
85~260AC
DPS
PS5
1 2 3 4 5 6
ON
1 2 3 4 5 6
Code=15, DIP-6=on
Code=13, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=14, DIP-6=on
Code=12, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=3, DIP-6=on
Code=1, DIP-6=on
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
Code=2, DIP-6=on
Code=0, DIP-6=on
OFF ON
OFF ON
monitor
monitor
monitor
monitor
monitor
monitor
monitor
monitor
BC4S
A B C D
BC4S
A B C D
Impedance
switch
Impedance
switch
DIP=on,off,off
DIP=on,off,off
RF CARD
(Device Address:0)
NOTE:Here we take DT27(the monitor) for example.
-7-
5. ID Card Registration
Introduction:
Up to 320 user cards can be registered by the door station.
Easy management with LED status and sound hints.
There are two master cards, one
MASTER CARD ADD
card and one
MASTER
CARD DELETE
card, When registered new master cards, the old master cards
are invalid automatically.
Card reading distance is from 3 to 5 cm.
The master cards are necessary when you add or delete user cards. Please keep it well for future use.
-8-
Add User Cards:
The color of background indicator
beep+,beep beep+ beep,beep+
Show the
MASTER CARD
ADD
card to ID card window
in standby mode.
Show user cards to be added, one by one.
Show the
MASTER CARD
ADD
card to exit.
(white)
The color of background indicator
(green blink
one time)
The color of background indicator
(blue)
Delete User Cards:
Notice:it will return to standby mode if no operation within 10s .Or press
Call Button
to exit the status of
setting and start to call the monitor.
The color of background indicator
beep+,beep beep+ beep,beep+
Show the
MASTER CARD
DELETE
card to ID card
window in standby mode.
Show user cards to be deleted in sequence
Show the
MASTER CARD
DELETE
card to exit.
(yellow)
The color of background indicator
(green blink
one time)
The color of background indicator
(blue)
Notice:it will return to standby mode if no operation within 20s.Or press
Call Button
to exit the status of
setting and start to call the monitor.
-9-
Access Initialization (delete all user cards):
Show the
MASTER CARD
DELETE
card to ID card
window in standby mode.
Show the
MASTER CARD
ADD
card to ID card window.
(At this time show the
MASTER CARD
DELETE
,
it will return to the "Delete User
Cards" state)
Show the
MASTER CARD
ADD
card to ID card window again,format operation is performing.
The color of background indicator
beep+,beep beep+
(yellow)
The color of background indicator
The color of background indicator
(green blink)(red)
beep+,beep
Notice:1.Automatically returns to standby mode after FORMAT completed.
2.It will return to standby mode if no operation within 20s.Or press
Call Button
to exit the status of
setting and start to call the monitor.
-10-
1. If show the authorized user card,the buzzer will sound of beep+,and the LED background indicator will light up.
2. If show the unauthorized user card,the buzzer will sound of beep,beep,beep.
6.Unlock Operations
When the registered user card has been shown to ID card window, the LED background indicator lights up, the buzzer sounds,and the electric door strike is unlocked.
Unlocking of ID Card
7.ID Settings of Door Station
The color of background indicator
beep+,beep
beep
Press the
Call Button
3 seconds.(At this time press the Call Button will to exit the setting,and start calling)
Press again the
Call Button
3 seconds.
(white)
The color of background indicator
(ID0:cyan)
(ID1:green)
(ID2:yellow)
(ID3:red)
beep,beep
beep,beep,beep
beep,beep,beep,beep
The ID of door station will circulate at
ID0 ID1 ID2 ID3.
At this time press the
Call Button
.
beep+,beep
If no operation within 5s,or press the
Call Button
3
seconds,it will exit the setting.
8. Precaustions
9. Specications
Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust.
The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit.
You must use the right adaptor which is supplied by the manufacture or approved by the manufacture..
Pay attention to the high voltage inside the products, please refer service only to a trained and qualied professional.
Power Supply : DC 24V (supplied by PS4-24V or PS5-24V);
Power Consumption: Standby 40mA; Working status 160mA;
Camera: Pinhole Sharp Color CCD; 420 TV Lines;
Lock Power supply: 12Vdc, 280mA(Internal Power);
Number of relay circuits: 2(the second lock need external device to support)
Mounting: Surface mounting DPC-D248-R Flush mounting DPC-D248-FR
Working temperature: -10ºC ~ +45ºC
Wiring: 2 wires,non-polarity
Dimension: 182(H)×93(W)×44(D)mm(DPC-D248-R)
220(H)×120(W)×50(D)mm(DPC-D248-FR)
-11-
-12-
The farest monitor
B
A
C
DPS
PS5
DBC/DBC-4
monitor
monitor
monitor
with two or four monitors
RF CARD
10. Cables Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach.
When Monitor quantity < 20
Cable Usage A B C
Twisted cable 2x0.75 mm
2
60 60 30
Twisted cable 2x1 mm
2
80 80 40
When Monitor quantity > 20
Cable Usage A B C
Twisted cable 2x1 mm
2
70 30 20
Twisted cable 2x1.5 mm
2
70 50 30
Note:If the monitor has been specied the distance,refer to
the parameter.
Loading...