The door station is an audio door station without camera, which is designed for 2-wire system.
The front panel is made of zinc alloy for better protection against vandalism & cauterization, and
the call button is also made of zinc alloy with blue backlight for auxiliary illumination, the unlock
and talking LED indicator guarantee the door station working efficiently.
With the rainy cover, the door station can be strongly protection against water.
Speaker
1
2
1
2
3
4
5
7
6
3
4
5
6
7
Terminal Description
Jumper
CALL button
SPK adjust
DIP PROG
ON
1 2 3
Connection line
ON
1 2 3
Lock Control
Lock Control Jumper: to select the lock type. Please refer to Electric Lock ConnectionDIP switch: to set ID code for door station, total 4 door stations can be supported. Please
refer to DIP Switch Setting.SPK adjust: to adjust the talk volume.PROG button: reserve.CALL button: press to call the user.4P terminal: to update software via specified programmer.Connection line: to connect the bus line and the electronic locks.
BUS(Blue&Green): connect to the bus line, no polarity.
S2+(Red): the S2+ connect with S1- to activate the relay to extend a camera of DPV-D246,
The audio door station DT595A can be extended an additional CCTV camera to be a video door
station. For more details about the camera, please refer to DPV-D246 user instructions.
DPV-D246
OUT IN
AC~
PC6
DS IM
Note:
1.
Electronic lock of Power-on-to-unlock type
should be used.
2.
The door lock is limited to 12V, and holding
current must be less than 250mA.
3.
The door lock control is not timed from Exit
Button(EB).
4.
The Unlock Mode Parameter of Monitor must
be set to 0 (by default).
Note:
1.
The external power supply must be used
according to the lock.
The DIP switch is designed to set the code for door station and monitor, there are two states for
each DIP switch, please refer to the following sketch map.
ON(1)
=
OFF(0)
=
Door station DIP setting
Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station, bit-3 is
used to match the video impedance.The switches can be modified either before or after installation.
Note: if the video impedance need to match, please set the bit-3 on.
Indoor monitor DIP setting
There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance,
otherwise set to OFF.
Bit-1~Bit-5 are used to set user code, to DT595A door station, the user code should set to 0~15.
Please refer to the following settings:
Bit state User codeBit state User code Bit state User code
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=0
code=1
code=2
code=3
code=4
code=5
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=6
code=7
code=8
code=9
code=10
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=11
code=12
code=13
code=14
code=15
Specification
• Power Supply: DC 24V
• Power Consumption: Standby 60mA; Working status 200mA
• Lock Power Supply:12Vdc, 300mA(Internal Power)
• Working Temperature: -10ºC ~ +45ºC
• Wiring: 2 wires, non-polarity
• Dimension:137(H)x49(W)x28(D)mm
Precaustions
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent.
If necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad
directly. Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
• Pay attention to the high voltage inside the products, please refer service only to a trained and qualified
professional.
Cable Usage
A B
C
Twisted cable 2x0.75 mm
2
60
60
30
Twisted cable 2x1 mm
2
80
80
40
Cable Requirements
Cable Usage
A B
C
Twisted cable 2x1 mm
2
70
30
20
Twisted cable 2x1.5 mm
2
70
50
30
The maximum distance of the wiring is limited in the D2 system. Using different cables may also
affect the maximum distance which the system can reach.
The farest monitor
with two or four monitors
monitor
When Monitor quantity < 20
AC~
monitor
monitor
C
PC6
DBC-4S
B
When Monitor quantity >20
Note: If the monitor has been specified
the distance, refer to the parameter.
A
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.