XtendLan DPC-511 User Manual

Page 1
DPC-511
Door station
User’s Guide
Page 2
1. Introductions
Door Station is a unit installed on the entrance of a building, which used to call a user in a apartment, and control the electronic lock opening.
To call the user, press a button with a associated nameplate of the user; then the user will press the Unlock button on the monitor to open the door for the visitor if she/he is accepted. The Camera angle can be adjusted to coordinate the install position of the Door Station
2. Parts and functions
Page 3
3. Terminals
• +12V: 12VDC power output .• LK-(GND): power ground.
• LK+(COM): electronical load activation relay contact common .• NO.: electronical load activation relay normally open contact
• EB+: Exit button.
• EB-: Exit button
• T/R-: USB-RS485 communication terminal negative .• T/R+: USB-RS485 communication terminal positive .• SET: DIP switches for system configurations.
• PA: program button A(refer to program section) .• PB: program button B.(refer to program section) .•Power (P-,P+): DC 18V
Page 4
DIP1
DIP2
DIP3
Door station address
OFF
OFF
OFF
Only one door station, set to 000
ON
OFF
OFF
Multi door station, first one address
OFF
ON
OFF
Multi door station, second one address
ON
ON
OFF
Multi door station, third one address
OFF
OFF
ON
Multi door station, fourth one address
ON
OFF
ON
Multi door station, fifth one address
OFF
ON ON
Multi door station, sixth one address
ON ON ON Multi door station, seventh one address
4. DIP Switches settings
Total 6 bits in the DIP s witches can be configured. The switches can be modified either before or after installation, but restart the power supply is needed whenever the switches have be en modified.
DIP1 DIP2 DIP3
The first three bit for door station ID settings When multi-door stations are installed in the system, these three bit must be set correctly, the door station’s DIP should set as below , If only one door station is installed , set to 000. The details as below:
DIP4
DIP4: button code selection DIP4=OFF=chose default codes for each button: (0001~0104), DIP4=ON=use the programmed codes, you can program each button on the door station by ST CONFIG software
DIP5
DIP5: Unlocking time quick selection DIP5=OFF=unlocking time 0.6 seconds DIP5=ON=can program by PC through software ( by default 5 seconds)
DIP6
DIP6=OFF=normal mode DIP6=ON=debug state enter, set to activate the debug state. Debug mode: When in this state, use the monitor to call , the outdoor station will call back automatism
Page 5
5. Place Name Plate
Press down and shift right/left to open the transparent nameplate cover, then insert the name paper, then put the plate cover back to the panel. Note that double button line panel can be opened both direction, single button line Can only be opened at right side.
6. Standard Installation
Page 6
7. Installation with expanding panel
8. ID CARD MANAGE
• Up to 1000 user cards can be registered by the Door Station.
• Easy management with LED state and Sound hint .• There are two master cards, one MASTER CARD ADD card and one MASTER CARD DELETE card, When adding a new master card, the old one will be replaced automatically.
• Card reading distance is from 3 to 5 cm. The Master cards are necessary when you add or delete user cards, Please keep the Master cards carefully. However, it is much easier to manage the ID cards using ST-CONFIG software.
Page 7
Page 8
9. Other functions :
1. <PA,PB >function
operate
PB button
PA button
Trigger mode
activate the monitor refer to the button at the right to debug and check
Activate program the monitor
address, one time trigger one
Three seconds mode
activate the monitor refer to the button at the left to debug and check
Program “ master ADD card” and “ master DELETE card”
Power on and push three seconds
Recover parameter by default
none
Power on and push three seconds and short the button which control open the door
Recover parameter which is default when it produce
none
2. MONITOR FUNCTION:
need indoor monitor support this function
2.1. multi door station in one system, only the master door station can monitored by indoor monitor
2.2. two indoor monitor can monitor(watch) in one time
2.3. monitor time: 30 seconds by default
Page 9
3. INTERCOM FUNCTION need indoor monitor support this function
4. MULTI OUTDOOR STATION
4.1. address should set to by DIP switch (details as above said) and the most quantity is seven outdoor station can support ( include the master door station)
4.2. any of the door station can call the indoor monitor, but if one of the door stations is contact with indoor monitor(audio phone), the other door station can not make a call, there will be a sound of beep: BP+, BP+
5. DPA-MRMDS:
5.1. Single DPA-MRMDS connection (DPA-MRMDS address by default):
5.1.1. master door station connect to VD/IN;
5.1.2. the second door station connect to CAM-1;
5.1.3. the third door station connect to CAM-2;
5.1.4. the fourth door station connect to CAM-3;
5.2. in multi door station mode, when door station call indoor monitor, if the indoor monitor have monitor function, then the DPA-MRMDS will output video from master door station
6. SET TO INDOOR MONITOR’S ADDRESS
6.1.1. power the door station and connect the monitor to the door station correctly, in the standby mode, press “PA” button( in the door station), there will be a hint sound ”BP+,BP+”,, and the indicator light of button will be close, that means it come to program mode;
6.1.2. then in five seconds , press the “call” button from indoor monitor, (otherwise, it will quit the program in 60seconds) ,the outdoor station will a hint sound, then do as below:
6.1.2.1. chose one wanted number button on the door station in two seconds, that
means the buttons you chose will be the indoor monitor’s room number. Waiting for about 5 seconds, if there is a long “D--------“ sound from the
Page 10
door station, that means the indoor monitor has been successfully programmed. But if it sounds “BP, BP, BP” , that means the operation is fail, should be the works again, if sounds “ BP, BP”, that means you use the same button two times, make the room number repeat , so please chose another button.
6.1.3. whatever success or fail for program, all the indicator light will be reback to light
6.1.4. if need program another indoor monitor, please work as above step by step once again
Loading...