XtendLan DPC-445ID User Manual

Installation Manual
DPC-445ID Outdoor Stati on ( D oor Camera with Card Reader)
Features:
-
Suitable for 4-wires Single Entry system, compatible with VT6xx serials of
monitors
-
Stainless steel panel, connect up to 4 Monitors directly
-
Flush mounting, with metal box
-
Capable of installing with Rainy Cover in flush mount
-
ID card or tags access security
Mount Instruction:
-
Cut a hole in 200x117x35mm size on the wall, input and fix mounting box with
screws.
-
Wire the cables, and test the single entry system unti l it works.
-
Put the DPC-445ID body into the box, then tight the screws firmly on top
and bottom.
Package List:
-
DPC-445ID unit
-
2 Master tags, for add and delete user cards
-
5 user tags (already authorized)
-
C3-4P cable to connect Monitor
-
2*C3-3P cable to connect latch, and JS/AP socket on Monitor
-
2*C3-2P cable to connect DC(+12V), and exit button
Parts and Functions:
1
CARD
2
3
4
5
6 7
1. Microphone
2. Camera
3. Speaker
4. Call Button
5. Access LED
6. Power LED
7. Card window
8. Fix screws (4)
8
Dimensions: 220(H)×125(W)×50(D)
Precautions:
-
Do not install in a place where there would be a bright light behind a visitor (or
where there would be a bright background), or in a place where the camera lens would be directly exposed to sunlight or a bright light. If light comes in on the unit's screen, the image looks white or silhouetted, this is not a unit malfunction.
-
Do not install the unit in places where High or extreme cold temperature,
moisture or humidity extremes, Constant vibration or impact, steam or smoke.
Specifications:
-
Power Supply: DC 10~12V (Powered by Monitors)
-
Power Consumption: 200mA in working state (latch is not included)
-
Video Output: 75Ohm Impedance, 1Vp-p, CCIR standard (unless specified)
-
Camera: 76 degree, CCD or CMOS camera with IR-LED for night vision
-
Working temperature: -10 ~ 40 degree
-
ID cards or tags: EM type or compatible
-
Cards Capacity: 50 user cards
-
Unlock timing: 5 seconds (or controlled by monitors)
- 2 -
- 3 -
- 4 -
Wiring Terminals on DPC­445ID
Illustration of DPC-445ID PCB Board
Terminals description
-
JS/DC: Connect to JS/AP on the Monitor, or external +12V Power Supply
-
JS/VP: Connect to JS/VP on the Monitor
-
JS/EB: Connect to external Exit Button
-
LB: Connect to latch (Dry Contact Mode)
-
LC: Connect to latch (DC output Mode)
-
JP/LS: Must be taken off if external Power Supply for latch is used
-
SET Jumper: Reserved, always set to right
-
ADD Jumper: If two DPC-445ID are installed, set ADD to right for 2nd DPC-445ID
-
PROG Button: Button used to authorize master cards
Wiring Diagram 1 (DPC-445ID is powered by Monitor)
Red
Black
White
Yellow
CN101
JS-OS1 JS-OS2
JS/VP
JS/AP
Wiring Diagram 2 (DPC-445ID is powered by Additional +12V Adaptor)
+12
- 5 -
- 6 -
2
3
2
Electronic Latch connecting instructions
-
Mode 1: With Monitor’s JP-LK Jumper (Dry contact)
LB
3
3 2
1
1
1,2: Normal-Open Contacts
3,2: Normal-Closed Contacts
-
Mode 2: Without Monitor’s JP-LK Jumper (DC output)
LC
3
2
1
1
LC Pin 3: 12V Output
LC pin 2: Do not connect
LC pin 1: GND
+
POWER
+
SUPPLY for Latch
+
Operation Instructions
Extra power supply for latch must be installed, and nearly all kinds of electronic latch can be used. in this mode, you can continue talking and monitoring during unlock operation. Note: JP/LS Jumper must be taken off.
If the latch (normally door Strike) rated voltage is DC 12V, and less than 500mA consumption. The Latch can be directly connect and powered by Monitor. During unlock operation, the monitor will close screen automatically.
Note: JP/LS Jumper must be reserved.
How to Program User Cards
The Master cards are necessary when you add or delete user cards.
Please keep the Master cards carefully.
-
Add user cards
Show the Master Card –ADD in standby. Note. LED will turns to orange, and beep sound.
-
Delete user cards
Show the Master Card –DELETE in standby. Note. LED flashes in red and orange in turn,
The upper LED is for access indicator, and will light after a valid User card is shown. The bottom LED is for state indicator, normally light in red, and turns to orange during programming.
There is a beeper inside DPC-445ID, in working state:
-
If a valid user card is shown, long beep;
-
If a invalid card is shown, three short beep;
In programming state:
-
Enter Programming state, long beep with short beep;
-
Exit Programming state, two short beep;
-
For user cards authorization, long beep if adding successfully, two long beep
and beep sound.
-
Delete all user cards(Format operation)
CARD
Show the Master Card –DELETE in standby.
Note. LED flashes in red and orange in turn, and beep sound.
MASTER
Show the cards to be added, one by one. Note. Long beep if add success, two long beep if repeated.
Show the cards to be deleted, one by one. Note. Long beep after deleting operation.
Show the Master Card –ADD to run format operation.
CARD
ADD
MASTER
CARD
DELETE
Show the Master Card –ADD again to exit.
However, will exit if no card was showed within 15s.
Show the Master Card –DELETE again to exit. However, will exit if no card was showed within 15s.
Show the Master Card –ADD again to confirm the Format operation.
if repeated, five short beep if the user cards are full (more than 50).
- 7 -
Program Instructions (Operate through Monitor)
-
Refer the Monitor manual to enter SETUP MENU, select INSTALLATION…, then
input password, you will see the Installation Menu on the Screen.
-
Select ADVANCED SET.. to enter, input 3# to add cards, and 4# to delete cards.
-
Please note, only DPM-D272T, DPM-471T, Monitors will support this
operation.
Program Instructions (Master Cards)
-
Authorize master card-ADD
Press PROG button on the DPC-445IDA PCB. Note. LED will turns to orange, and beep sound.
Show the card to be authorized. Note. Will exit if press PROG again or after 5 seconds
Long beep if authorize correctly, and will exit automatically. Note. The old Master card will be replaced.
-
Authorize master card-DELETE
Keep pressing PROG button for 2seconds on the DPC-445ID A PCB. Note. LED flashes in red and
Show the card to be authorized. Note. Will exit if press PROG again or after 5 seconds
Long beep if authorize correctly, and will exit automatically. Note. The old Master
card will be replaced. orange in turn, and beep sound.
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.
Loading...