The relay actuator RLC is a accessory device designed for DT system to control door
locks and lights. It has the features as follows:
• Allows to open gate door locks and control lights;
• Support high power-consumption lock;
• With configurable unlock timed output;
• Support exit control button.
2.Parts and Name
lock Control1
2
Jumper
NC
COM
NO
GND
RLC
GND NO COM NC 12V S2 S1 GND
3
POWER IN-USE
2-WIRE SYSTEM
BUS BUS RISE R
12V
S2
S1
GND
1
2
3
DIP
DIP
POWER
IN-USE
+12V:12V power output. Can be used to power the lock.
S2:Reserved.
S1:Exit button contact. Short this contact and the GND to unlock.
GND:The common Ground of the other 3 contacts: S1, S2 and +12V.
BUS
-2
NC:The normally-closed contact to COM.
COM: The common contact of the unlock relay.
NO: The normally-open contact to COM.
Lock Control Jumper: To select the lock type: see section 5,6.
POWER:Working indicator,it will light up when plugs in power supply.
IN-USE:Unlock indicator,it will light up when unlock.
Bus:Connect to the bus line, no polarity.
DIP :Used for setting the address of the RLC.
2.Unit Mounting
RLC
GND NO COM NC
POWER IN-USE
2-WIRE SYSTEM
12V S2 S1 GND
BUS BUS RISER
1
2
3
3.How to set the work mode
1).In DIP 1 = ON, DIP 2 = ON, DIP 3 = OFF status, exit button(S1 and GND) shortcircuit, meanwhile, the RLC will power-on to activate the setting mode;
2).In setting status, struck repeatedly DIP 1 four times to switch work modes:
A.When the IN-USE indicator flashes once, it means the system will enter the lock
control mode.
B.When the IN-USE indicator flashes two times, it means the system will enter the
light control mode.
3).When the setting complete,it will automatically restart.
Please note the setting state valid within 5 seconds, more than five seconds without
operation, it will exit the setting mode automatically.
DIN Rail Mounting
-3
4.How to set the unlock time
DIP
Bit State
Descriptions
ON
1 2 3
OFF,OFF,OFF
Applies to door station1 & lock 1
In ock control mode:
1). Power-on within 5 seconds, short-circuit S2 up to 3 seconds, the IN-USE indicator
flash.
2). Short-circuit S1 up to 3 seconds, and the IN-USE indicator always light.
3). Short-circuit again S2, meanwhile, the time of short-circuit equal to unlock time.
(the IN-USE indicator flashes once per second, Less than two seconds by one second
calculation; The maximum setting time is 30 seconds.)
4). After S2 released, saved unlock time, and exit the setting.
5.How to set the light working time
In ight control mode:
1). Power-on within 5 seconds, short-circuit S2 up to 3 seconds, the IN-USE indicator
flash.
2). Short-circuit S1 up to 3 seconds, and the IN-USE indicator always light.
3). Short-circuit again S2, meanwhile, the time of short-circuit 1 seconds equal to light
working time 30 seconds.(the IN-USE indicator flashes once per second, Less than
two seconds by one second calculation; The maximum setting time is 30 seconds.)
4). After S2 released, saved unlock time, and exit the setting.
6.DIP Switch Setting
The DIP switch in the back of the panel is used to set the address of the RLC. Please
refer to the followings for more detail informations about the DIP settings:
A.
DIP settings for lock.
-4
ON ON
ON
ON
ON ON ON ON ON ON 1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
DIP Bit State Descriptions
B.
DIP settings for light.
DIP Bit State Descriptions
OFF,OFF,ON Applies to door station1 & lock 2
ON,OFF,OFF Applies to door station2 & lock 1
ON,OFF,ON Applies to door station2 & lock 2
OFF,ON,OFF Applies to door station3 & lock 1
OFF,ON,ON Applies to door station3 & lock 2
ON,ON,OFF Applies to door station4 & lock 1
ON,ON,ON Applies to door station4 & lock 2
OFF,OFF,OFF Set to the first RLC.
OFF,OFF,ON Set to the second RLC.
ON,OFF,OFF Set to the third RLC.
-5
ON
2
1
ON ON ON ON ON 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
DIP 3
DIP Bit State Descriptions
ON,OFF,ON Set to the fourth RLC.
OFF,ON,OFF Set to the fifth RLC.
OFF,ON,ON Set to the sixth RLC.
ON,ON,OFF Set to the seventh RLC.
ON,ON,ON Set to the eighth RLC.
7. Internal powered lock connection(only suitable for Power-on-
to-unlock type)
RLC control the second lock of door station 1
E-lock
+
-
AC~
monitor
PC6
GND NO COM NC 12V S2 S1 GND
POWER IN-USE
GND NO COM NC 12V S2 S1 GND
RLC 2-WIRE SYSTEM
1
2
3
RISER
BUS BUS
BUS(IM) BUS(DS)
Exit Button
1# Camera
(Device Address:0)
L1 L2 PL S+ S-
-
+
-6
DIP
ON
1
2
3
RLC connect lock
Note:
1. When RLC connect Electronic
lock, the jumper position in 1-2.
2. When RLC connect E-magnetic
lock, the jumper position in 2-3.
8.RLC Connections for Light Control
monitor
110~250V AC Input
AC~
PC6
BUS(IM) BUS(DS)
Jumper position in 1-2
+
-
E-lock
GND NO COM NC
GND NO COM NC 12V S2 S1 GND
RLC 2-W IRE SYSTEM
GND NO COM NC 12V S2 S1 GND
POWER IN-USE
BUS BUS
1
2
3
RISER
1 2 3
Exit Button
*
12V S2 S1 GND
RLC
(Device Address:0)
L1 L2 PL S+ S -
-
+
-7
DIP
ON
1
2
3
9. External Power Supply powered lock connection
A. Power-on-to-unlock type:
RLC control the second lock of door station 1
monitor
RLC connect lock
Note:
1. Here 's lock type is
adaptor for the l ock
Electronic lock.
E-lock
AC~
-
+
BUS(IM) BUS(DS)
E-lock
POWER IN-USE
GND NO COM NC 12V S2 S1 GND
RLC 2-WIRE SYS TEM
G
N
D
1
2
3
RISER
BUS BUS
GND NO COM NC
POWER
SUPPLY
12V S2 S1 GND
PC6
RLC
Exit Button
1# Camera
(Device Address:0)
L1 L2 PL S+ S -
-
+
Exit Button
*
-8
DIP
ON
1
2
3
B.P ower-off-to-unlock type:
RLC control the second lock of door station 1
adaptor for the lo ck
monitor
RLC connect lock
Note:
1. Here's lock type is
E-magnetic lock.
EM-lock
AC~
-
+
GND NO COM NC 12V S2 S1 GND
RLC 2-WIRE SYSTEM
PC6
BUS BUS
POWER IN-USE
BUS(IM) BUS(DS)
POWER
SUPPLY
GND NO COM NC
RLC
S1
G
N
D
1
2
3
RISER
EM-LOCK
12V S2 S1 GND
Exit Button
1# Camera
(Device Address:0)
L1 L2 PL S+ S -
-
+
Exit Button
*
-9
DIP DIP
ON
ON
1
2
3
1
2
3
10.Connecting 2 RLCs
You can connect 2 RLCs to control both the front door lock and light.
adaptor for the lock
110~250V AC Input
AC~
monitor
E-lock
Safety Type: power-on to open
power-off to lock
N N L SW
LED
PC6
BUS(IM) BUS(DS)
GND NO COM NC 12V S2 S1 GND
RLC
POWER IN-USE
GND NO COM NC 12V S2 S1 GND
RLC
POWER IN-USE
RF CARD
(Device Address:0)
Exit Button
11. Specification
• Power Supply : DC24V;
• Unlocking Time: 1~30s(Default 1s);
• Lock Power supply: 12Vdc, 450mA(Internal Power);
• Working Temperature: -100C~+400C;
• Dimension: 89(H)×71(W)×45(D)mm.
The design and specifications can be changed without notice to the user. Right to interpret
and copyright of this manual are preserved.