DPA-D2-DBC4 USER MANUAL
1. Parts and Functions
Impedance
switch
OFF
ON
DIP
BUS
Output Output
A
B C D
IN-USE:Status indicator,it will light up when receives signal.
POWER:Working indicator,it will light up when plugs in power supply.
Impedance Switch:Video match switch, the last DBC4 at the end of the
bus should set ON to match the video impedance,
the power indicator will turn to orange after setting.
Bus:Input port,bus connection port.
A,B,C,D:Output port,connect to indoor monitors or door stations.
DIP :Used for current control when connected with different devices.
2. Unit Mounting
DBC4
DIN Rail Mounting

3. DIP Switch Setting
The DIP switch in the back of the panel is used to adjust the terminal start-up current.
Please refer to the followings for more detail informations about the DIP settings:
DIP Bit State Descriptions
ON
1 2 3
ON
1 2 3
ON
1 2 3
ON,OFF,OFF
OFF,ON,OFF
OFF,OFF,ON
The output port A,B,C,D connected with the device such as
monitor(all D2 model monitors),outdoor camera(e.g.DPCD241),and DPC-D211 series without ID function model.
The output port A,B,C,D connected with DPC-D211-xx-ID
series with ID function model.
The output port A,B,C,D connected with DPC-D218ID series
door station.
Please note that DPC-D24x (like DPC-D241-1) and DPC-D218 can not be
connected to the same DBC4, If it happen,please use two DBC4.
The same situation as DPC-D211 and DPC-D218 model.
4. System Wiring with DBC4
Mulit Door Station Wiring:
4# Camera
ID=11
ON
1 2
3# Camera
ID=01
2
2# Camera
ID=10
2
1# Camera
ID=00
2
L1 L2 PL S1+ S2+ S-
L1 L2 PL S1+ S2+ S-
L1 L2 PL S1+ S2+ S-
L1 L2 PL S1+ S2+
S-
switch
A B C D
DBC4
DPS
OFF
ON
PS5
85~260VAC
DIP=on,off,off
Impedance
monitors

5. Specification
Power Supply : DC24V
Working Temperature: -100C~+400C;
Wiring: 2 wires (non-polarity);
Dimension: 89(H)×70(W)×45(D)mm