C5-VD is a data and video signal amplifier
in the K5 system, used to increase the distance
between the door station and the farthest
distributor from 80 meters to 240 meters and to
realize the muti-riser connection style where more
than one riser is needed inside the building. It can
also be used where the distributors in one riser
has reached more than 20 to increase the number
of distributors (therefore monitors) that can be
connected in the riser.
The amplifier must be connected at a point in the riser less than 80 meters
from the door station, regardless of whether there be C5-IPC in between or not,
and must be in cascading connection with the distributors.
§ 2. Feature
Data and video signal separating and amplifying. The use of one C5-VD can
extend the length of the riser by 80 meters can make another 12 distributors
available for the system.
Maximum 2 C5-VD can be connected in cascading connection within one
riser.
-1-
§ 3. Parts and Functions
VIDEO MATCH SWITCH
180
HI
POWER
C5-VD
INUSE
POWER INPUTDIP SWITCH
LINK
§ 4. DIP switch and video switch
C5-VD
ON DIP
INPUT1 INPUT2
OUTPUT1 OUTPUT2
DIP settings:
(1).When used with C5-F4 or C5-F414:
DIP3 and DIP4 must be set to ON, the
rest to OFF.
(2).When used with C5-F422:
DIP3 and DIP4 must be set to OFF, the
rest to ON.
Note: When used with F422, it has to be opened
to set the jumper to the 2&3 position.
ONDIP
DIP
ONDIP
DIP
The Jumper
1
32
-2-
Video Switch
(1).When used at the end of the riser:
180
HI
(2).When used at the middle of the riser:
C5-VD
180
HI
§ 5. Specifications
Power supply: DC24V
Standby current: 10mA
Working current: 15mA
Working temperature: -10ºC ~ 40ºC
C5-VD
Connection port: RJ4S
Dimensions: 88*140*32mm
-3-
§ 6. Applications
(1).Data and video amplifying in the riser:
Applied where the riser has reached more than 80 meters or the number
of the distributors is more than 20. In such cases, maximum 2 C5-VD can
be connected in cascade in the riser. One C5-VD enables the riser to have
another 80 meters in length and another 12 distributors. And by use of 2
C5-VD, the length of the riser can go up to 240 meters and number of
distributors can reach 44.
NOTE:The distance from the
C5-VD to the last distributor
must not be more than 80
meters and the the quantity
of distributors should be no
more than 12.
180
HI
HI
120
C5-F4
To Next C5-F4
…
…
To other monitors
-
+
PS5
AC
C5-VD
FV+FV-P- AU P-P+ P+D1&D2
4B
1R 2W
C5-F4
-
+
3Y
GDVD T/R+T/R- Z1 Z2 Z3 Z4COM COMPR
C5-F4
HI
120
-
+
ON DIP
C5-AT27
1
2
3
4
C5-VD
ONDIP
NOTE:The distance from the C5-VD
to the door station must not
be more than 80 meters and
the the quantity of distributors
in between should be no more
than 20.
Keep 3 jumpers
POWER
S1
VR600
PA
ON DIP
AG
LINK
+
1
2 3 4 5 6
IN-USE
SW1
12
3
P+P- P+ P- RS485
JWB(IN) JWB(OUT) CN(MDS) ETHERNET
C5-IPC
-
+
AC
PS5
1 2 3
7 8 9
*
RF CARD
654
#0
F4/F4DV/F4Q
LAN
SW1
1 2
3
P-
P+
P+ P- RS485
JWB(IN) JWB(OUT) CN(MDS) ETHERNET
-
+
-
CN-LK
EB+
EB-
N.O
LK+
LK-
J/KMBJP-LK
+
T/R- T/R+
+12V
12
3
CN1
Bus
CN2
CAT5
RVV2*1.0mm2
Note that ID Code(#8001-1) setting in DPC-D218ID must be set to 1
-4-
(2).Realizing multi-riser connection style:
Applied where there are more than one tower in one building, to realize
multi-riser connection style. The use of one C5-VD will add another riser
to the system.
HI
120
HI
120
-
+
AC
PS5
C5-F4
180
C5-F4
To other monitors
-
+
C5-F4
C5-VD
To Next C5-F4
…
…
FV+FV-P- AUP-P+ P+D1&D2
4B
1R2W
3Y
GDVD T/R+T/R- Z1 Z2Z3 Z4 COMCOMPR
-
+
ON DIP
C5-AT27
1
2
3
4
HI
120
C5-F4
To Next C5-F4
…
…
To other monitors
-
+
AC
FV+FV-P- AUP-P+ P+D1&D2
4B
1R2W
PS5
C5-F4
-
+
3Y
GDVD T/R+T/R- Z1 Z2Z3 Z4 COMCOMPR
C5-F4
HI
120
C5-AT27
1
2
3
4
HI
C5-VD
ONDIP
1 2
P-
P+
-
+
SW1
3
P+ P- RS485
JWB(IN) JWB(OUT) CN(MDS) ETHERNET
F4/F4DV/F4Q
LAN
Note:The distance from the DS to
AG
12
P+P- P+ P- RS485
S1
ON DIP
1
2 3 4 5 6
SW1
3
JWB(IN) JWB(OUT) CN(MDS) ETHERNET
C5-IPC
Keep 3 jumpers
POWER
VR600
PA
LINK
+
IN-USE
the last Distributor is no more
than 80 meters and the number
-
+
PS5
AC
1 2 3
7 8 9
*
CN-LK
RF CARD
654
#0
EB+
T/R- T/R+
EB-
N.O
LK+
LK-
+12V
J/KMBJP-LK
-
+
CN2
CN1
Bus
12
3
of distributors is no more than
20 in this riser.
CAT5
RVV2*1.0mm2
Note that ID Code(#8001-1) setting in DPC-D218ID must be set to 1
-5-
(3).Realizing multi-riser connection style and signal amplication:
In some cases, apart from the need of multi-riser, each of these risers
may also need a C5-VD to realize signal amplifying because of the long
distance or the large number of distributors.
HI
120
HI
120
-
+
AC
PS5
180
C5-F4
C5-VD
C5-F4
To other monitors
-
+
C5-F4
To Next C5-F4
…
-
+
…
ON DIP
FV+FV-P- AUP-P+P+D1&D2
4B
1R2W
3Y
GDVD T/R+T/R- Z1 Z2 Z3Z4 COMCOMPR
C5-AT27
1
2
3
4
HI
120
C5-F4
To Next C5-F4
…
…
To other monitors
-
+
AC
FV+FV-P- AUP-P+P+D1&D2
4B
1R2W
-
+
PS5
C5-F4
3Y
GDVD T/R+T/R- Z1 Z2 Z3Z4 COMCOMPR
C5-F4
HI
120
-
C5-VD
+
ON DIP
C5-AT27
1
2
3
4
HI
C5-VD
180
C5-VD
HI
ONDIP
1 2
P-
P+
-
+
3
P+ P- RS485
SW1
F4/F4DV/F4Q
JWB(IN) JWB(OUT) CN(MDS) ETHERNET
LAN
Note:The distance from the DS to the
last Distributor is more than 80
meters or the number of distributors
AG
P+P- P+ P- RS485
S1
ON DIP
1
2 3 4 5 6
12
3
C5-IPC
SW1
Keep 3 jumpers
POWER
PA
LINK
IN-USE
JWB(IN) JWB(OUT) CN(MDS) ETHERNET
VR600
+
is more than 20 in this riser.
-
+
PS5
AC
1 2 3
7 8 9
*
RF CARD
654
#0
CN-LK
EB+
EB-
N.O
LK+
LK-
+12V
J/KMBJP-LK
T/R- T/R+
3
-
+
CN2
CN1
Bus
12
CAT5
RVV2*1.0mm2
Note that ID Code(#8001-1) setting in DPC-D218ID must be set to 1
-6-
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.