PARAMETRIC EQUALIZATION
The P500 is a 5-band parametric equalizer. Its design
allows the user to vary center frequency, select a “Q” of 110, and select up to 18 dB of boost or cut.
Center frequencies range from 20 Hz to 20 KHz. The onboard frequency jumper divides the frequency range into three
bands: 20 Hz to 200 Hz, 200 Hz to 2 KHz, and 2 KHz to 20 KHz.
Simply place the jumper in one of the three positions which corresponds with the frequency to be adjusted. The specific frequency is then selected via the “frequency” potentiometer
“Q” determines the range of frequencies affected on either
side of the center frequency. “Q” is equal to the center fre-
quency divided by the bandwidth. As “Q” goes up, bandwidth
decreases. The P500’s “Q” adjustment ranges from a narrow
bandwidth of 10 to a very broad bandwidth of 1.
Boost / Cut on the P500 is +/–18 dB. The rotary potentiometer provides continuously variable adjustment.
P500 TUNING SEQUENCE
The P500 is designed to be “set-up” or “tuned” with the aid
of a Real Time Spectrum Analyzer measuring a pink noise sig-
nal generated by the mobile audio system. The analyzer provides visual feedback when following the steps listed below.
RTA the system and determine points of adjustment. Turn
the system off and place each of the frequency range jumpers
into their corresponding “frequency range” positions.
•••••••••
installer’s reference
xtant technologies
THI S DOCUMENT HA S BEEN CRAFTED TO MAKE INSTALLA-
TION, SYSTEM DESIGN A N D TROUBLE- SHOOTING, A QUICK
A ND EASY PROCESS
. THE CHARTS PROVIDED, OFFER A SIM-
PL E METHOD O F DOCUMENTATION.
IT IS IMPORTANT THAT YOU RETAIN THIS LOG
FOR YOUR RECORDS. O
N PAGE 8 OF THE OWNER’S
MANUAL, YOU WILL FIND THE OWNER’S REFERENCE LOG.
O
NCE YOU HAVE NOTATED THE FINAL SETTINGS FOR THIS
P500, TRANSFER THOSE SETTINGS TO TH E OWNER’S
REFERENCE LOG. IN THE FUTURE, A N Y SYSTEM EXPANSION
AND
/ OR PROBLEMS M AY BE REFERENCED TO THIS LOG.
INSTALLATION SEQUENCE
REMOVE P500 COVER:
Loosen allen head screws and lift-off cover. Do not remove
protective covering on stainless steel lid until installation is complete.
TEMPORARILY MOUNT P500:
The P500 is designed to be anchored through the four (4)
holes located on the circuit board/base assembly.
MARK WIRES FOR TERMINA TION AND REMOVE P500:
Determine wire lengths for Power, Ground & Remote and
mark for cutting/termination. Remove P500 before cutting and terminating all wires. CAUTION: stripping
wires over the circuit board may cause product failure.
INPUT SENSITIVITY:
Make initial adjustment to input gain at your work bench.
Refer to the section “Input Sensitivity” on the reverse
side.
BALANCED LINE:
Make initial adjustment at your work bench. Refer to the
section “Balanced Line” on the reverse side
MOUNT THE P500 AND MAKE ALL CONNECTIONS:
Re-install the P500 and make all wire connections. i.e.
Power, Ground, Remote and RCA input/outputs.
DOUBLE CHECK ALL CONNECTIONS! TURN ON P500:
Check red LED, it should be on.
MAKE ALL EQUALIZATION ADJUSTMENTS:
Refer to “P500 Tuning Sequence” in this “Reference”
ADJUST NOISE GATE THRESHOLD (IF USED):
Refer to “Activating the Noise Gate” on the reverse side
AFTER FINE TUNING THE SYSTEM:
Remove protective covering from P500 and clean. Attach
cover to base.
•••••••••
INSTALLER’ S REFERENCE LOG
DA T E INSTALLED:
OWNER’S NAME: PHONE:
A DDRESS:
CITY/STATE: ZIP:
VEHICLE: YEAR:
XTANT P500 SERIAL#
MODES OF OPERATION: (CIRCLE SETTING)
INPUT MODE: 4 CHANNEL 2 CHANNEL
BALANCED LINE: ENABLE DISABLE
NOISE GATE: O N DEFEAT
P500 ADJUSTMENTS (DRAW POSITION OF CONTROL & CIRCLE FREQ. RANGE SELECTED)
system components
SOURCE SERIAL #
PROCESSOR( S) SERIAL #
SERIAL #
AMPLIFIER( S) SERIAL #
SERIAL #
SERIAL #
xtant technologies •••••••••
7676 SOUTH 46TH STREET PHOENIX, ARIZONA 85040 USA
••••••••602 431 8686
CENTER FREQUENCY
RANGE OF BOOST
/CUT
LOW “Q”: A WIDER RANGE OF FRE-
QUENCIES (ON EITHER SIDE OF THE
CENTER FREQUENCY
) ARE AFFECT-
ED BY EQUALIZATION.
HIGH “Q”: A NARROW RANGE OF
FREQUENCIES
(ON EITHER SIDE OF
THE CENTER FREQUENCY
) ARE
AFFECTED BY EQUALIZATION
.
Perform the following steps per band:
With the system playing pink noise, turn on the
RTA and adjust pink noise SPL to 85 – 90 dB.
Turn the boost/cut control to +18 dB (full clockwise
rotation). This will show the present center frequency and “Q” settings on the analyzer.
Rotate frequency control to the frequency you wish to
adjust.
Adjust “Q” setting to match the width of the dip or
peak you are addressing.
Finally, adjust the gain control to achieve the desired
response curve.
Freq. Range
20 – 200 Hz
200 – 2 KHz
2K – 20 KHz
Freq. Range
20 – 200 Hz
200 – 2 KHz
2K – 20 KHz
Freq. Range
20 – 200 Hz
200 – 2 KHz
2K – 20 KHz
Freq. Range
20 – 200 Hz
200 – 2 KHz
2K – 20 KHz
Freq. Range
20 – 200 Hz
200 – 2 KHz
2K – 20 KHz
front “a”
front “b” front “c” rear “a” rear “b”
+/– 18 dB
Q ADJUST
FREQ.
+/– 18 dB
Q ADJUST
FREQ.
+/– 18 dB
Q ADJUST
FREQ.
+/– 18 dB
Q ADJUST
FREQ.
+/– 18 dB
Q ADJUST
FREQ.