INPUT SENSITIVITY ADJUSTMENT
The 1001dx offers five (5) input gain settings. The adjustment runs in 10 dB steps from -20 dB to + 20 dB. This wide range of adjustment allows the 1001dx to accept input voltages from 100 mV to 7 V. Adjustment is made by installing a jumper across the associated input voltage/pin location. Refer to the illustration on the reverse side of this document prior to setting the input sensitivity.
CROSSOVER MODES OF OPERATION
The 1001dx is equiped with a two-way electronic crossover. The Lowpass function of the crossover is dedi­cated to the amplifier (1001dx) and the Hipass function of the crossover is available at the on-board RCA line outputs.
The jumper labeled Lowpass Slope Select allows either 12 or 24 dB per octaves slopes to be selected for the Lowpass function of the 1001dx.
The Line Out Mode Select jumper controls the function of the on-board RCA line outputs and offers two (2) modes of operation: Bypass and HiPass.
The Hipass Slope Select jumper provides independent 12 or 24 dB per octave slope selection for the Hipass function available at the RCA Line Outputs.
The High and Low Pass frequenies are determined by the Frequency Modules (SIPs) installed in the three (3) SIP sockets pictured on the reverse side of this document. One SIP determines the Lowpass frequency, while two (2) SIPs determine the Hipass frequency. Each frequency setting is independent and may be changed to suit your needs.
CROSSOVER FREQUENCY MODULES
The following is a chart of Xtant’s available frequency modules. The frequency module (SIP) “ID Code” printed on the SIP and the associated frequency value is detailed below.
SIP Number Frequency
224 50 Hz 134 70 Hz 114 80 Hz 104 90 Hz 683 120 Hz 563 150 Hz 273 300 Hz 153 500 Hz 103 700 Hz 752 1 kHz 242 3 kHz 182 4 kHz 152 5 kHz
The 1001dx is shipped from the factory with 90 Hz HiPass and LowPass frequency modules (SIP) installed. To change a frequency module, simply remove the resistor SIP and replace it with the appropriate SIP value to achieve the desired frequency.
•••••••••
installer’s reference
xtant technologies
THIS DOCUMENT HA S BEEN CRAFTED TO MAKE INSTALLA-
TION, SYSTEM DESIGN A N D TROUBLE- SHOOTING, A QUICK A ND EASY PROCESS
. THE CHARTS PROVIDED, OFFER A SIM-
PL E METHOD O F DOCUMENTATION.
IT IS IMPORTANT THAT YOU RETAIN THIS LOG FOR YOUR RECORDS. O
N PAGE 12 O F THE OWNERS
MANUAL, YOU WILL FIND THE OWNERS REFERENCE LOG. O
NCE YOU HAVE NOTATED THE FINAL SETTINGS FOR THIS
1001DX, TRANSFER THOSE SETTINGS T O T HE OWNERS REFERENCE LOG. IN THE FUTURE, A N Y SYSTEM EXPANSION
AND
/ O R PROBLEMS MA Y B E REFERENCED T O THIS LOG.
INSTALLATION SEQUENCE
REMOVE AMPLIFIER COVER:
Loosen allen head screws and lift-off cover. Do not remove protec­tive covering on stainless steel lid until installation is complete.
TEMPORARILY MOUNT AMPLIFIER:
The amplifier is designed to be anchored through the four (4) holes located on the circuit board/base assembly.
MARK WIRES FOR TERMINATION AND REMOVE 1001DX:
Determine wire lengths for Power, Ground, Remote, & speaker cables. Mark for cutting/termination. Remove 1001dx before cutting and terminating all wires. CAUTION: stripping wires over the circuit board may cause product failure.
CROSSOVER SET-UP:
Adjust crossover mode jumpers at your work bench. Also, change crossover frequency SIP’s if desired.
INPUT SENSITIVITY:
Make initial adjustment to input gain at your work bench. To increase input gain, place jumper in the +20 dB position. To decrease input gain, place jumper in the 0, -10, or -20 dB position.
MOUNT THE AMPLIFIER AND MAKE ALL CONNECTIONS:
Install the amplifier and make all wire connections. i.e:.Speaker, Power, Remote, Ground, and RCA input.
DOUBLE CHECK ALL CONNECTIONS! TURN ON AMPLIFIER.
Check red LED, it should be on.
ADJUST AMPLIFIER OUTPUT GAIN POT. AFTER FINE TUNING THE SYSTEM:
Remove protective covering from amplifier and clean per the maintanence section on page 9 of the Owner’s Manual. Attach cover to base.
•••••••••
INSTALLERS REFERENCE LOG
DA TE INSTALLED: OWNERS NAME: PHONE:
A DDRESS: CITY/STATE: ZIP: VEHICLE: YEAR: XTANT AMPLIFIER:MODEL SERIAL#
CROSSOVER SETTINGS: JUMPER SETTINGS:
LOWPASS FREQ: SLOPE: 12 dB 24 dB VALUE CODE: PHASE: NORMAL INVERT
HIPASS FREQ
: R C A OUTPUTS (CIRCLE SETTING)
VALUE CODE:
BYPASS HIPASS
SLOPE: 12 dB 24 dB
INPUT SENSITIVITY JUMPER (CIRCLE SETTING)
–20 dB (X .1) –10 dB (X .3) 0 dB (X 1) +10 dB (X 3) +20 dB (X 10)
OUTPUT GAIN ADJUSTMENT
PQM-1 YES NO
(
DRAW ARROW POSITION
)
LFQ 45 YES NO
BLM-1 YES NO
system components
SOURCE SERIAL # PROCESSOR( S) SERIAL #
SERIAL #
AMPLIFIER( S) SERIAL #
SERIAL # SERIAL #
xtant technologies •••••••••
7676 SOUTH 46TH STREET. PHOENIX, ARIZONA 85040 USA
••••••••602.431.8686
REV 1197
MAXI
FUSE
MAXI
FUSE
REMOTE
GROUND
12 V
YELLOW LED
LOW IMPEDANCE
BLUE LED
LOW VOLTAGE
ORANGE LED
THERMAL PROTECT
RED LED
POWER ON
DUAL SPEAKER OUTPUTS
LEFT RIGHT
INPUTS
LEFT RIGHT
+20
+10
0
–10
–20
+
+
FAN
INVERT
BYPASS
HIPASS
NORMAL
24 dB/OCT.
24 dB/OCT.
12 dB/OCT.
12 dB/OCT.
AMP PHASE
SELECT
LINE OUT MODE
SELECT
LP SLOPE
SELECT
HP SLOPE
SELECT
EQ MODULE PORT:
REMOVE JUMPERS PRIOR TO INSTALLINGEITHER THE OPTIONAL
PQM-1 OR LFQ 45 MODULE.
JUMPERS MUST BE IN PLACE IF AN EQ MODULE IS NOT INSTALLED
.
DUAL SPEAKER OUTPUT TERMINALS:
EVEN THOUGH THE 1001dX IS A MONO AMPLIFIER, 2 SETS OF SPEAKER OUTPUT TERMINALS HAVE BEEN PROVIDED
. BOTH POSITIVE TERMINALS
AND NEGATIVE TERMINALS ARE PARALLELED
. EITHER SET OF TERMINALS
OR BOTHSETS OF TERMINALS MA YBE USED
. THIS FEA TURE WILL HELP TO
SIMPLIFY THE P ARALLEL CONNECTION OF MULTIPLE WOOFERS AND INSURE MAXIMUM CURRENT FLOW
.
BALANCED LINE PORT:
JUMPERS MUST BE IN PLACE WHEN OPTIONAL
BLM-1
MODULE IS NOT INSTALLED.
REMOTE SWITCHED
12 VOLTS
16 GAUGE OR LARGER
NOTE: ADD FUSE A T POSITIVE TERMINAL OF THE BATTER Y. THE V ALUE OF THIS FUSE SHOULD EQUAL THE COMBINED TOTAL OF
ALL AMPLIFIER FUSES IN THE SYSTEM
.
GROUND – 4 GAUGE OR LARGER
SPEAKER WIRE 12 GAUGE OR LARGER
POWER – 4 GAUGE OR LARGER
INPUT SENSITIVITY:TO ADJUST INPUT GAIN, MOVE JUMPER (IF NEEDED) – AND INSTALL IT IN THE LOCATION WHICH
MATCHES YOUR INPUT SIGNAL LEVEL
. REFER TO THE ILLUSTRATION BELOW FOR PROPER JUMPER LOCATION / LEVEL SETTING.
NOTE: –20 dB = 10V – 17V IS ONLY TO BE USED WITH BALANCED INPUT FROM A BALANCED SOURCE.
–20 dB = 10V– 17V
–10 dB = 3V – 8V 0 dB = 1V – 3V +10 dB = 300mV–1V +20dB= 100– 300mV
LOW PASS FREQ SIP
AMPLIFIER GAIN CONTROL:
TURN CLOCKWISE TO INCREASE GAIN
XTANT TECHNOLOGIES 7676 SOUTH 46TH STREET PHOENIX, ARIZONA 85040 PHONE: 602.431.8686 FAX 602.431.8600
HIGH PASS FREQ SIP
HIGH PASS FREQ SIP
LEFT CHANNEL
RIGHT CHANNEL
INSTALLER’S REFERENCE
..............
XT ANT 1001dx
..............
Caution: SHARP EDGES
be careful when
handling top and
bottom metal.
SERVICE JUMPER: REMOVING JUMPER WILL TURN-OFF AMPLIFIER
WHEN REMOTE TURN
-ON, GROUND AND +12 VOLT CABLES ARE CONNECT-
ED TO AMPLIFIER. USE TO SERVICE/ADJUST AMPLIFIER WHEN IN USE.
AMP PHASE SELECT: THE AMP PHASE SELECT JUMPER ALLOWS
YOU TO INVERT THE PHASE BY
180º AT THE OUTPUT OF THE 1001dX.
T
HIS JUMPER DOES NOT AFFECT THE PHASE OF THE RCA LINE OUTPUTS.
OUTPUTS