XS Instruments BL 224 Basic Basic User Manual

1
BL 224 Basic
User Manual
2
Index
Warning and safety use instructions ............................................................................................................. 2
Spare Parts ..................................................................................................................................................... 2
Overview ........................................................................................................................................................ 3
Remarks ......................................................................................................................................................... 3
Preparation before Use ................................................................................................................................. 3
Keypad ........................................................................................................................................................... 4
Normal weighing ........................................................................................................................................... 4
Calibration ..................................................................................................................................................... 5
Function Operation ....................................................................................................................................... 5
PCS counting .................................................................................................................................................. 5
Percentage ..................................................................................................................................................... 6
Density ........................................................................................................................................................... 6
Settings Menu ................................................................................................................................................ 7
Software Exchange ........................................................................................................................................ 7
Data sheet...................................................................................................................................................... 8
Maintenance .................................................................................................................................................. 8
Warranty ........................................................................................................................................................ 8
Warning and safety use instructions
To avoid damage of the balance, please read the operation manual carefully
before use.
Please do not use it in dangerous environment.
Please cut off the electricity without use for more than one week.
Please power off the balance when it connects with output device or before cut off the connection.
Magnet or static interference will affect the accuracy of balance, when these
interference removed, balance will recover to normal use.
Spare Parts
The spare parts we used are the most compatible with the balance.
Any revision to the balance or use the third party’s cable and other device, it’s end user’s
responsibility to check and correct the power and voltage.
Please do not open the out case, if the safety label is damaged, warranty
will not be guaranteed.
3
Overview
LCD backlight display, easy and clear.
Operator-friendly, direct weigh, directly read the weighing result.
Highly smart, tare and back to zero within the whole weighing scope, overload
display.
Multi-mode choice: counting, percentage weigh, density weigh.
RS-232C interface, easy to connect with printer and PC
Remarks
Do not wash with water;
Do not install the balance in places where is too hot or too wet, with vibration,corrosion, strong
magnet or with the risk of explosion;
Do not load excess samples (not over the max capacity
If the balance is not used for a long time , please clean it up ,pack it by plastic bag with drier in ;
Please pre-heat for 60 minutes before use the balance.
Preparation before Use
Adjust level before use.
Use the air bubble and feet under the front to adjust the level until the bubble move to the centre of the circle.
Put the balance on the stable and flat table, not on shaking or vibrating plate, to make the balance
stable. (Recommend to use aseismic marble)
Avoid to put balance in place with big temperature change or air flow, such as the place with direct
sunlight or cold air outlet.
Please use the separate power socket to avoid the interruption by other device.
Please do not put anything on the scale when power on the balance.
Make balance adjust itself to the change of temperature.
When change the balance from lower temperature to higher temperature or reverse, please put the balance in the new environment for about 2 hours, then pre-heat the balance , make it conform with the new room temperature.
4
Keypad
Button
Description
On / Off
Switch On-Off the balance
Zero / Cal
Short press: When measure is ≤ 6g – back to zero Long press: Enter calibration procedure
Tare
Tare – Scroll menu and number in setup
Print
Print – Change the position in settings
Mode
Function selection (weigh – PCS counting - Percentage…)
Unit
Short press: Unit conversion Long press: 1d / 10d conversion
Normal weighing
Preparation
Connect the power supply.
Press On/Off button to switch on the balance.
Pre-heat Time
In order to ensure the precision of weighing, please preheat the balance completely reference to technical parameter form (page 19-20), then start the following operation .
Measure.
Example
Basic weigh operationbalance already pre-heated
Display
1
Zero position stable
0.0000 g
2
Put the container on the plate
50.0000 g
3
Tare the balance (TARE key)
0.0000 g
4
Put the sample in the container
68.3357 g
5
Calibration
In order to ensure the precision of weighing, please preheat the balance completely before the calibration
Procedure
Display
1
Zero position stable
0.0000 g
2
With no load on the plate, keep pressed CAL key for 5 seconds
CAL
3
Scale value blinks for 3 seconds
200.0000 g
4
Put the correspondent external certificated weight on the plate
-------------
5
Display the calibrated valued
200.0000 g
Calibration complete
Function Operation
To choose the operating mode keep pressed MODE key for 3 seconds:
All functions are displayed, in a cycle:
Normal weighing mode
NORMAL
g
Pieces counting
COUNT
Pcs
Percentage weigh mode
PERCENT
%
Density measure mdoe
DENSITY
d
Press MODE to confirm the selection.
Density measure mode is an option, if you need please contact our company or authorized Distributor
PCS counting
By this procedure the user measures the total weight of the certain samples which with similar single weight, then divided by the single sample weight to get the final quantity of the sample.
Procedure
Display
1
Select COUNT mode
COUNT pcs
2
Display asks for sample number
20 pcs
3
Use Tare to select an alternative number
10, 20, 100 …
4
Put the correspondent numbers of samples on the pan
-------------
5
Press CAL to confirm the sample number
20 pcs
6
Unload the pan
0 pcs
7
Putt all your samples on the pan
167 pcs
In Count Mode, to reset the sample number value, press MODE.
To Exit the Count Mode: Keep pressed MODE key, and then choose the normal weigh mode.
6
Percentage
The end user can make a certain weight as definition 100%, then make other weight displayed as the percentage of the definition weight.
Procedure
Display
1
Select Percent Mode
PERCENT %
2
Press TARE to select the precision of percentage
3
Put on the pan the chosen % sample (es. 100,00%)
100,00 %
4
Press CAL to confirm sample 100%
100,00 %
5
Take off the sample
0,00 %
6
Put the unknown % sample
8,00 %
In PERCENT Mode, to reset the sample % value, press MODE.
To Exit the PERCENT Mode: Keep pressed MODE key, and then choose the normal weigh mode.
Density
By using this procedure user can measure the density value for solid or liquid so that judge the sample desirable or not. (need to buy the optional density kits). First measure the solid density in air, and then the density of the solid in a certain liquid ( the density of the liquid must be known in advance)
Procedure
Display
1
Select Density Mode
DENSITY d
2
Press CAL to confirm the solid density measurement
SOLID
3
Balance asks for the liquid temperature coefficient (refer to Form1)- CAL to confirm
01.00000 d
4
The balance reminding to weight in air
HI
5
Put the sample and weight in air
6.8135 g
6
Press Cal to record the value
LO
7
Take off the solid
0.0000 g
8
Put the solid in liquid
1.3518 g
9
Press Cal to record the weight in liquid
OK
10
Display show the solid density calculated
1.2398 g
d
Result
1.2398 g/cm
3
If you want to measure different solid’s density, please repeat step 4-8.
In the solid density measure mode, if you want to reset the liquid density coefficient, press MODE
to re-enter the coefficient setting.
Exit the density mode: Long press MODE and choose the normal weigh mode
7
Settings Menu
To enter in the settings menu, keep pressed TARE + ZERO keys for 3 seconds, display shows Cod0000.
TARE : scroll the numbers or chose the parameters PRINT : change position ZERO : confirm and enter in the next step.
Code
Mark display
Description
Setting range
Cod 0001
Zero – x.x
Zero range
0.0 d – 6.0 d
Stdy - x.x
Start sensitive range
0.0 d – 6.0 d
Sens – x
Inner sensitivity grade
1,2,3,4,5,6
Filt – x
Stability Filter
1,2,3,4,5,6,7 -- 1 weakest – 7 strongest
Speed
Weighing speed
1,2,3 -- 1 slow - 3 fast
BL – xxx
Backlight
On, Off, AUTO
BEPxxx
Beeper
On, Off
ModRec
Function mode
0: switch on always in normal mode 1: switch on in the last weighing mode used
Tadj
Display temperature
-1.9 to +1.9
Baud xx
Baud rate
12; 1200; 24; 2400; 48; 4800; 96; 9600.
Con – xxx
Communication
NON: no communication CON: continuous STY: print when stable KEY: print when press PRINT key SOFT: software exchange Txxx: timing print, xxx is the time set, in sec
BLANk
Output the blank line
Line 0,1,2,3,4,5,6,7,8,9
Cod 0002
Unit - xxx
Unit on display
On, Off
Software Exchange
List of command which the communicating device can send in software exchange mode. (ASCII code)
No.
Command
Function
1 ? Sample
2 P Print
3 T Tare
4 Z Back to Zero
5 U Unit
8
Data sheet
Model
XS BL 224
Capacity
220 g
Precision level
I
Division
0.0001 g
Repeatability
± 0.0003 g
Linearity
± 0.0003 g
Stable time
≈ 3 sec
Warmup time
60 – 120 minutes
Operation temperature
20 ± 2,5 °C
Plate diameter
90 mm
Overall dimensions
325mmX205mmX305mmL*W*H
Chamber dimensions
180mmX175mmX200mmL*W*H
Net weight
≈ 6kg
Adapter power supply
460mmX360mmX400mmL*W*H
Maintenance
Cleaning
Unplug the power adapter from the socket.
If there is cable connecting with the balance interface, unplug the cable as well .
Clean the balance by a cloth soaked in neutral flush (soap).
After cleaning, wipe the balance by a soft dry cloth.
Taking up the bracket to check the weighing system not damaged.
Don’t make the liquid flow into the shield of balance; Don’t use the corrosive flush(solvent) to clean the
stainless steel surface. All the stainless steel parts need to be flushed frequently, take out of all the stainless steel parts and flush them completely, use the wet cloth or sponge to clean the stainless steel parts. Only use the homely flush suitable to clean stainless steel parts.
Warranty
We offer two years warranty for the balance from the date it sold out. Damages not caused by misuse or vandalism all belong to warranty exclude the following case:
Balance out of warranty.
Damage caused by misuses such as long time under sunshine or receive corrosion.
The user does not obey the operation manual such as overloading the balance.
If the user disassembly the balance on his own, without authorized technician support.
Any brute force application caused the damage of balance. E.g. throw the heavy loads to the pan,
open or shut the chamber door violently. If you have any quality problem, please pack the product well together with the warranty card, then contact the distributor. The sensor is not within warranty range. Any product out of warranty or caused by misuse will be charged a reasonable repairing fee.
9
Disposal of electronic devices
The electrical and electronic equipment marked with this symbol cannot be disposed of in public landfills. According to the UE Directive 2002/96/EC, the European users of electrical and electronic equipment can return it to the dealer or manufacturer upon purchase of a new one. The illegal disposal of electrical and electronic equipment is punished with an administrative fine.
Loading...