XPR Access B100PROX-EH-SA v2, B100PROX-MF-SA v2 Installer Manual

B100PROX-EH-SA v2 B100PROX-MF-SA v2
Standalone Biometric Reader
1
INSTALLER’S MANUAL
v. c2
INTRODUCTION
MOUNTING
SPECIFICATIONS
APPLICATION DIAGRAM
RECOMMENDED SWIPING TECHNIQUE
INDICATION
WIRING
ADDING ADMIN FINGER
PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing B100PROX-SA v2 with DINRTT
Pairing B100PROX-SA v2 with RTT
Pairing B100PROX-SA v2 with RU2
ADMINISTRATOR PROGRAMMING
ADD Finger Relay 1
ADD Finger Relay 2
ADD Finger Relay 1&2
DELETE Finger
DELETE ALL Fingers
CHANGE ADMIN Finger
CHANGE INSTALLER Finger
Administrator Programming block diagram
INSTALLER PROGRAMMING
Set Relay 1 Time
Set Relay 2 Time
BUZZER ON/OFF
BACKLIGHT ON/OFF
Installer Programming block diagram
2
3
4
4
4
4
5
5
..............................................................
..............................................................
...........................................................
...........................................................
.............................................................
....................................................................
....................................................................
...........................................
..............................................................
..............................................................
..............................................................
..............................
...........................................................
...........................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
..............................................................
...........................................................
7 7 7 7 7 8 8 8
8
6 6 6
9 9 9
9 9
10
...........................................................
6
2
B100PROX-SA v2 is access control fingerprint reader designed for easy management of the users and configuration. The scanner is made with advanced capacitive sensing technology that provides some advantages over optical solutions like:
- making almost impossible to make fake copy of the users fingers
- same performance in the different light conditions
- good reading of fingers with stains from daily jobs Built in strong scanning and matching algorithm provides excellent tolerance in the way finger is swiped over the sensor reducing to minimum the need to repeat finger swiping at the sensor. The reader can store up to 100 finger templates and 2000 cards. One template is reserved for User manager (Administrator), one template is reserved for Reader configuration (Installer) and up to 98 templates are for Users.
This manual is used for both B100PROX-EH-SA (EM/HID Cards) and B100PROX-MF-SA (Mifare Cards).
INTRODUCTION
Consult with installer about safety level of the installation. There are devices with relays compatible with this reader that can increase the security of the system if needed. One or two enrolled fingers are enough for one user. Ask the installer before he leaves the site to enroll your finger as administrator.
Do not touch the sensor with other objects than finger. Do not pour or splash with water or other liquids. When painting or construction work is ongoing in the area around the reader, protect the reader sensor area from possible damages and paint. If reader is to be dismounted or relocated, call authorized installer for the job. Disposal of this product must be handled according to all national laws and regulations.
RECOMMENDATIONS
NOTES
The Reader is using physical roughness of the fingerprint to scan the finger. Some of the users may have very flat fingertips, making difficult for the sensor to recognize correctly the fingerprint. In most cases, these are children and older persons. To solve this problem, do the following:
1. Try with different user’s fingers to find the “best” finger.
2. Check with the installer other models of the reader with added card reader or keypad for other type of access.
MAINTENANCE
No special or periodic maintenance is required. If cleaning is needed, use soft wet cloth and wipe gently the dirt. Do not use chemicals and materials that can scratch the sensor.
WARNING!
3
MOUNTING
100 mm
94 mm
30 mm
Cable
Ø6.0
30mm
MCD-MINI
Do not install the device and cabling close to a source of strong electro-magnetic fields like radio-transmitting antenna. Do not place the device near or above heating equipments. If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel. Do not let children touch the device without supervision. Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered.
If the biometric reader is installed and used outdoor, the reader MUST be fitted with the MCD-MINI metal cover available in our accessories in order to protect the sensor from direct rainfall. The operating temperature of the product is between -20ºC - + 50ºC. If the reader is installed in an environment where the temperature can drop below -10ºC or/and if the sensor could only be exposed to direct sunlight, it is strongly recommended to install the reader inside a third party sealed wall mount box (fitted with additional heater if very low temperature) to keep a constant sensor level performance. XPR™ cannot guarantee the functionality of the product if measures and advice before are not followed. It is also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use different readers depending on users.
Fingerprint Capacity: Prox. cards Capacity: Card Type:
Output: Push Button Input: Door Open Time: Entry Mode: Programming: Master/Admin Fingers: Backlight ON/OFF: Buzzer ON/OFF: Firmware upgrade: Current Consumption: Power Supply: Indication: IP Factor: Storage/Operating Temperature : Storage/Operating Humidity: Dimensions(mm):
98 templates 2000 cards EM or HID compatible (125KHz) - B100PROX-EH-SA or Mifare (13,56 Mhz; Classic 1K & 4K, Ultralight, Desfire) - B100PROX-MF-SA 1 x Relay (2A/24V AC/DC) Yes Pulse (1 to 30 seconds) or Toggle(ON/OFF) Finger or Card By swiping 1 Administrator and 1 Installer Finger Yes Yes via converter and windows applicationRS485 150 mA max. 9-14 V DC Tricolor Status LED IP65
-20°C to +50°C 5% to 93% RH without condensation 100 x 94 x 30
4
SPECIFICATIONS
APPLICATION DIAGRAM
R
S485 (max. 50m)
DINRT T (Oponal)
2 Relay Remote Unit
and request-to-exit Buon
RTT (Oponal)
1 Relay Remote Unit
and request-to-exit Buon
RU2 (Oponal)
2 Relay Remote Unit
OR
Secured Area Outside
B100PROX-EH/MF-SA v2
Standalone Biometric Reader
MCD- MINI
(Oponal)
Metal Cover
NC COM
NO
Tamp
Blue
Yellow
Red
Black
Pink
Violet
Orange
Gray
White
PB
RS485
+
_
12VDC
POWER SUPPLY
+
_
NC
COM
GND (PB)
PB
+
_
Electro Magnetic Lock
Green
Blue
Yellow
Red
Black
Pink
Violet
Orange
Gray
White
Green
Colour
Connection
Tamper
12V DC
Red
Black
White
Yellow
Grey
NC COM
NO
GND
Green
Relay
(2A)
Push Button
Orange
Pink
Violet
Blue
Tamper
A (RS485)
B (RS485)
1N4001
Diode
12V DC GND
A B
+
-
+
_
12VDC
POWER SUPPLY
NO
COM
GND (PB)
PB
+
_
Blue
Yellow
Red
Black
Pink
Violet
Orange
Gray
White
Green
1N4001
Diode
Electric Strike
ON
1 2
ON
1 2
Adding Admin Finger
CARD Type
Dipswitch A: Card Type
ON: HID OFF: EM
ON
1 2
Dipswitch A Dipswitch B
Dipswitch B: Adding Admin Finger
ON
1 2
reader back view
Switch No. 2
Switch No. 2
B100PROX-SA
+12V GND NO COM
A
B
NC
PB1
TAMP TAMP
Relay
(2A)
RS 485
Power Supply
ON
1 2
Dipswitch A (sw. no.2)
Card Type
ON
1 2
Dipswitch B (sw. no.2)
Adding Master Finger
Push Button
ON: HID OFF: EM
5
Only in B100PROX-EH-SA v2
WIRING
Wiring B100PROX-SA with magnetic lock
Wiring B100PROX-SA with electric strike
DIPSwitch settings
6
ADDING ADMIN FINGER
1.Push dip switch no.2 in position ON.
2.Reset the Power of the device.
3.Wait for One long + multiple short beeps
4.Put the dip switch in position OFF. (short beeps will stop)
5.Wait for about 15 seconds for the LED to blink in Orange.
6.Swipe the Master finger min.6 times. (Until Ok Beep)
No.2
No.2
Warning: This procedure also deletes all the users and the installer finger. Warning: This procedure will unpair the connected relay unit (RTT, DINRTT or RU2)
x 6
ON
1 2
ON
1 2
Tricolor Status LED
- Access GrantedGreen
- Access deniedRed
- Idle ModeOrange
OK Beep - short + long beep
- 3 short beepsError Beep
Swipe Finger - 2 short beeps
INDICATION
Follow the below instructions for correct finger swiping. Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement.
Result: For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep) For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps)
RECOMMENDED SWIPING TECHNIQUE
12/24V AC/DC
B (RS485)
A (RS485)
1. Close the Jumper. DINRTT beeps continuously and the red led blinks.
2. Open the Jumper
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
P
B2
G
ND
PB1
G
N
D
NC1
COM
NO1
NC2
COM
NO2
A
B
T
A
MP
TA
M
P
R
S485
GND
+12V
GND
+12V
Exit Button
(NO)
1N4007
+
-
12 VDC
+
-
DINRT T
+12V
+12V
GND
GND
G
N
D
P
B1
NO1
COM
1 2
Black
Red
Pink
Violet
B
R
S485
12 VDC
+
-
1. Put Dipswitch No.1 to position ON. RTT beeps continuously and the red led blinks.
2. Put Dipswitch No.1 to position OFF.
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
1 2
ON
If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also can play the role of request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay’s Manual.
12 VDC
+
-
1N4007
+
-
RTT
Black
Red
Pink
Violet
Black
Brown
Pink
Violet
Red
White
Yellow
COM
NO
GND
12V out
A (RS485)
B (RS485)
7
Warning: Changing the ADMIN finger will also unpair the remote relay unit.
PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT
Pairing B100PROX-SA v2 with DINRTT
Pairing B100PROX-SA v2 with RTT
Pairing B100PROX-SA v2 with RU2
1. Put the Jumper to closed position. RU2 beeps continuously and the red led blinks.
2. Put the Jumper to open position.
3. Wait for Beep + OK Beep (short + short + long beep)
After the OK beep, the coupling is done.
12 VDC
+
-
1N4007
+
-
RU2
Violet
Pink
COMNO
A (RS485)
B (RS485)
+12V
GND
GND
+12V
B100PROX-SA
1
2
max. 50 meters
max. 50 meters
max. 50 meters
8
short beep
Swipe Admin Finger 1 time
Action
Wait 5 seconds (until fast blinking)
Swipe User Finger min. 6 times
(until short + long beep)
Finger
Backlight
Buzzer Sound
x 1
Use point fingers as Administrator and Installer. You can use the other fingers as access fingers. Administrator finger is enrolled at the end of the system installation. Initial enrollment of the Admin finger is described in installer manual.
ADMINISTRATOR PROGRAMMING
ADD Finger Relay 1 (Finger that will activate on board relay 1)
slow blinking
fast blinking
short + long beep
short beep
INSTALLER
RIGHT
ADMIN
LEFT
x 6
Present card/tag 1 time
fast blinking
short + long beep
x 1
or
Swipe Admin Finger 2 times
Action
Wait 5 seconds (until fast blinking)
Finger
Backlight
Buzzer Sound
x 2
ADD Finger Relay 2 (Finger that will activate remote relay 2)
slow blinking
fast blinking
short beep
short + long beep
short beep
Swipe User Finger min. 6 times
(until short + long beep)
x 6
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
Present card/tag 1 time
fast blinking
short + long beep
x 1
or
Swipe Admin Finger 3 times
Action
Wait 5 seconds (until fast blinking)
Finger
Backlight
Buzzer Sound
x 3
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
ADD Finger Relay 1&2 (Finger that will activate relay 1&2)
slow blinking
fast blinking
short beep
short + long beep
short beep
Swipe User Finger min. 6 times
(until short + long beep)
x 6
Present card/tag 1 time
fast blinking
short + long beep
x 1
or
Swipe Admin Finger 4 times
Action
Wait 5 seconds (until fast blinking)
Swipe User Finger
Finger
Backlight
Buzzer Sound
x 4
DELETE Finger
slow blinking
fast blinking
short beep
short + long beep
short beep
x 1
Present card/tag 1 time
short + long beep
x 1
or
fast blinking
Swipe Admin Finger 5 times
Action
Wait 5 seconds (until fast blinking)
Swipe NEW Admin Finger min.6 times
Finger
Backlight
Buzzer Sound
x 5
x 6
short beep
short + long beep
3 short beeps
Swipe Admin Finger 6 times
Action
Wait 5 seconds (until fast blinking)
Swipe NEW Installer Finger min.6 times
Finger
Backlight
Buzzer Sound
x 6
x 6
CHANGE ADMIN Finger
CHANGE INSTALLER Finger
slow blinking
slow blinking
fast blinking
short beep
short + long beep
short beep
slow blinking
slow blinking
fast blinking
short beep
multiple beeps
Swipe Admin Finger 4 times
Action
Wait 5 seconds (until fast blinking)
Swipe Admin Finger 2 times
Finger
Backlight
Buzzer Sound
x 4
x 2
DELETE ALL Fingers and Cards
slow blinking
slow blinking
fast blinking
short beep
9
ADD Finger
Relay 1
(on board)
1 swipe
ADD Finger
Relay 2
(remote)
ADD Finger
Relay 1&2
DELETE FINGER
Change
ADMIN
Finger
Enroll
INSTALLER
Finger
2 swipes 3 swipes
4 swipes
5 swipes
6 swipes
Wait
5 seconds
(until fast blinking)
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
already enrolled
finger 1 time
or present card/tag
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
new finger
min. 6 times
or
present
card/tag
SWIPE
ADMIN finger
2 times
to
DELETE ALL
SWIPE
new ADMIN
FINGER
min. 6 times
SWIPE
new
INSTALLER
FINGER
min. 6 times
Swipe the ADMIN Finger 1 to 6 times depending of the desired menu
END END
END
END
END
END END
Administrator Programming block diagram
Only in combination
with DIN RTT and R U2
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
10
short beep
Swipe Installer Finger 1 time
Action
Swipe the INSTALLER Finger
and start counting seconds
Finger
Backlight
Buzzer Sound
Set Relay 1 Time (on board)
slow blinking
fast blinking
beeps on 1 second
short beep
INSTALLER PROGRAMMING
x 1
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
fast blinking
short + long beep
x 1
x 1
short beep
Swipe Installer Finger 2 times
Action
Swipe the INSTALLER Finger
and start counting seconds
Finger
Backlight
Buzzer Sound
Set Relay 2 Time (remote)
slow blinking
fast blinking
beeps on 1 second
short beep
x 2
Swipe the INSTALLER Finger
to stop or wait 30 seconds to
put the relay in toggle mode
fast blinking
short + long beep
x 1
x 1
Swipe Installer Finger 3 times
Action
Swipe Installer Finger
Finger
Backlight
Buzzer Sound
x 3
Swipe Installer Finger 4 times
Action
Swipe Installer Finger
Finger
Backlight
Buzzer Sound
x 4
BUZZER ON/OFF
slow blinking
fast blinking
short beep
short + long beep
short beep
slow blinking
fast blinking
short beep
short + long beep
short beep
BACKLIGHT ON/OFF
x 1
x 1
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Wait 5 seconds (until fast blinking)
Relay 2 is available if the reader is used with remote relay unit with 2 relays(DINRTT and RU2). Consult the installer if Relay 2 is available in your system.
11
12
Set
RELAY 1
Time
(on board)
1 swipe
Set
RELAY 2
Time
(remote)
BUZZER
ON/OFF
BACKLIGHT
ON/OFF
2 swipes 3 swipes
4 swipes
Wait
5 seconds
(until fast blinking)
Swipe the Installer Finger 1 to 4 times depending of the desired menu
END END
END
END
Installer Programming block diagram
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to put the Buzzer ON/OFF
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Only in combination
with DIN RTT and R U2
Swipe the Installer Finger
and start counting seconds
Swipe the Installer Finger
to stop or wait 30 seconds
to put the relay in toggle
ON/OFF mode
Swipe the Installer Finger
to put the Backlight
ON/OFF
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
Wait
5 seconds
(until fast blinking)
This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS directive EN50581:2012
Loading...