Parts List .................................................................................................................................... 9
Warranty Registration Form ......................................................................................................10
- 1 -
Introduction
Thank you for purchasing the XPOWER X-35AR and X-48ATR Hi-Temp Turbo-Pro professional
axial air movers. XPOWER Manufacture, Inc. has over 25 years of manufacturing experience,
bringing a series of products with the most advanced technology in today’s market. Our goal with the
X-35 or X-48 Series was to bring an axial air mover never seen before. Through our research and
design, we have brought a revolutionary series of air movers to the industry that provide long-life
operation, excellent performance, compact design and extremely low noise. Our axial air movers are
completely speed controllable-- a first in the industry. We also offer a high quality dual outlet for
daisy-chaining and a 3 hour timer (X-48ATR) for ease of use in professional applications. Enjoy!
Features
SEALED INDUCTION MOTOR
The advanced design SEALED INDUCTION MOTOR protects the internal motor parts from dust
and moisture accumulation, thus, making it very suitable to be used in highly contaminated and
wet environment areas.
HEAT-RESISTANT
The unit is made with high temperature resistant material for lethal room temperature.
- 2 -
VARIABLE SPEED CONTROL SWITCH:
An industry first, our completely variable speed control allows you to adjust the fan speed
exactly to your liking. This is extremely useful in ventilation applications where precise volume
guidelines need to be met.
DAISY CHAIN FEATURE:
2 Built-In Outlets allowing multiple units to be connected together.
3-HOUR TIMER: (For X-48ATR)
Extremely convenient in busy contractor projects for the professional or a busy afternoon for
the handyman, 3 hour timer allows you to setup multiple fans without having to come back to
turn them off.
SPECIALLY DESIGNED AIR FIN GUIDE:
Contoured to provide maximum focused and extended airflow volume and velocity.
(Technology targets air flow up to 60 ft.)
360° ROTATION- RACK STAND INCLUDED:
Full rotation of the axial air mover to fit the need of any project including drying flooded floors,
painted walls and damp damaged ceilings.
SUPER LIGHTWEIGHT:
Durable ABS+PC Housing
COMPACT DESIGN W/ STACKABILITY:
Stackable Up To 5 Units
- 3 -
Operation
1) With the unit unplugged, carefully place the XPOWER unit on a stable, flat, and dry surface.
2) Plug the cord into a grounded G.F.C.I. outlet only, the use of a 3-prong to 2-prong adapter
is strictly prohibited.
3) Turn on the switch to make sure the axial air mover is operating correctly.
4) To reduce the risk of injury, close supervision is necessary when an appliance is used near
children. Do not allow children to play with or around an Axial Air Mover at any time.
Daisy Chain
If utilizing the Daisy-Chain feature, only allow up to two additional axial fans or other devices
running together on total 12 AMPs circuit. X-35AR & X-48ATR axial air movers have an on-board
circuit breaker. If the auxiliary outlet overloads, the circuit breaker will trip. If the breaker does trip,
unplug the units and press the circuit breaker Reset button. Plug the units back into the power
source and turn on the switch.
Timer (for X-48ATR)
Model X-48ATR using a timer can be set up to 3 hours long. After the timer expires, the axial air
mover will turn off while the speed control will be at the last set position. Set position to off and
then again at a desired speed to continue operation.
Rack
The unit includes a durable and sturdy rack which allows 360° full angle rotation.
- 4 -
Specificaons
ModelX-35ARX-48ATR
TimerN.A.Incl.
360° Rotational Coverage
115V / 60Hz
Injection-molded ABS + PC
20 ft / 14 AWG
Volt/Frequency
Airflow1720 CFM3600 CFM
Amps1.6 A2.8 A
Power1/4 HP1/3 HP
Weight17.6 lbs25.6 lbs
Dimensions (LxWxH)18.6x9.4x19.2 inch21.9x9.8x22.5 inch
Cord
Housing
Positions
Daisy ChainIncl.Incl.
- 5 -
Safety Instructions
1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug
the unit with wet hands or while standing in water.
2. To avoid risk of injury, do not direct air flow at face or body.
3. Suitable for use with solid-state speed controls.
4. Use only with GFCI protected receptacles. Please contact a qualified electrician for
verification and / or installation of a GFCI receptacle if necessary.
5. Do not operate any unit with a damaged cord or plug. Discard axial air mover or return to an
authorized service facility for examination and/or repair.
6. To reduce the risk of injury, disconnect from power supply before servicing.
7. Do not run cord under carpeting. Do not cover cord with throw rugs, runners, or similar
coverings. Do not route cord under furniture or appliances. Arrange cord away from traffic area
and where it will not be tripped over.
8. Do not allow children to play with or around an axial air mover at any time.
9. Do not move or carry the axial air mover while unit is operating.
10. Keep air intakes and exhausts clean at all times to avoid clogging or blocking in order to
prevent overheating the unit. Blocking the air intake could result in a fire or electrical hazards.
11. To prevent injury to persons and to avoid objects from coming in contact with the fan blade,
do not remove any screens or safety guards from this unit. Altering this unit will void your
warranty.
12. Always place the axial air mover on a smooth and level surface for safe operation.
13. Do not use unit if defective or damaged.
14. Unplug the unit before performing any maintenance, cleaning, or servicing.
15. Any misuse or abuse of this product will void the warranty.
16. An electronic instruction manual can be obtained through the manufacture’s website
www.xpower.com.
- 6 -
XPOWER Limited Warranty (USA)
XPOWER’s Limited Warranty covers the unit (excluding POWER CORD) from defects in material
and craftsmanship. The Warranty covers normal use for a term of one year from the original date
of purchase including parts, labor and one way shipping. Non-contiguous states must pay for
roundtrip freight. A purchase receipt must be provided.
Important!
This warranty does not cover or apply to defects due directly or indirectly to misuse, abuse,
disassembly, alteration, corrosive chemicals, improper voltage, fire, flood, negligence, accident,
improperly or incorrectly performed maintenance or repair, or failure to perform necessary maintenance or repair, or if the use of this product is not in compliance with the instructions and specifications for its use.
Service
For Warranty service and parts replacement (US users only), you must:
A. Call 1-855-855-8868 for a RMA (Return-Merchandise-Authorization) number.
B. Have original proof of purchase.
C. Use the original undamaged packaging or an industrial certified packaging method.
End user will be responsible to ship the unit (with RMA Number showing on the shipping label) to
the XPOWER Service Department. XPOWER will inspect, assess and advise the repairs needed
and the applicable cost, if any. For users outside the US, please contact an XPOWER Distributor
in your country or region for Warranty service and parts replacement.
- 7 -
Maintenance Instructions
1. Always disconnect the axial air mover from its power source before performing any
maintenance or cleaning.
2. Never clean the unit with water directly.
3. When not in use, unplug and store the axial air mover in a dry indoor place out of reach of
children.
4. To keep the axial air mover clean, use a damp cloth to wipe the surface of the housing.
Troubleshooting
SYMPTOMPROBABLE CAUSEACTION
Make sure unit is plugged in
Switched Off
Motor Not Running
Power failure
Wiring failureContact XPOWER for repair
Obstructions at the
Scraping Noise From Fan
Weak Air FlowObstructed vents/inletsClean out vents/inlets
intake or exhaust of fan
Fan broken
and switch is turned to ON
mode
Check outlet/Change to
another outlet
Remove obstruction(s)
Contact XPOWER for repair
- 8 -
Parts List
Item # Parts NameItem #Parts NameItem # Parts Name