Input
Input Voltage • 36-72 VDC, DC input versions
90-264 VAC, AC input versions
Input Frequency • 47-63 Hz
Inrush Current • 30 A at 115 VAC, 60 A at 264 VAC
40 A at 48 VDC for DC version
Power Factor • 0.99
Leakage Current • <3 mA
Output
Output Adjustment • ±0.25 V on each rail
Load Regulation • See Table
Line Regulation • See Table
Ripple & Noise • See Table
Overvoltage • 125-135% Vnom recycle input
Protection to reset
Overload • Recycle input to reset
Protection
Overtemperature • Automatic shutdown at 100 °C
Protection measured internally with auto restart
Remote Sense • V1, V2 & V3 compensates for
0.5 V drop
Power Fail • TTL compatible signal, open collector
active low signal. Indicates any output
below 90% and/or low input below
60 VAC for AC version or 36 VDC for
DC version
Front Panel LED • Power good (green),
Power fail (amber)
Inhibit • ON = Logic high or open circuit
OFF = Low low or shorted to ground
Enable • ON = Logic low or shorted to ground
OFF = Logic high or open
General
Efficiency • 70% typical
Switching Frequency • 200 kHz ±20%
Current Share • Accuracy of current share with up to
6 parallel units is 10%, available on
V1, V2 & V3.
Isolation • Input to ground 1500 VAC
Input to output 3000 VAC
Weight • 1.8 kg (4 lbs)
Environmental
Operating • 0 °C to +70 °C, derate from 100% load
Temperature at +50 °C to 50% load at +70 °C
Cooling • 400 LFM/30 CFM at 50 °C
(full power operation)
Storage • -40 °C to +85 °C
Temperature
Overtemperature • TTL compatible signal provides
Warning warning when power supply
temperature exceeds rating
Relative Humidity • 5-95% non-condensing
Shock & Vibration • MIL-STD-810D
EMC & Safety
Safety Approvals • EN60950 (TÜV), UL1950,
CSA950/234 per cUL, CE LVD
EMC • EN55022 level A radiated & conducted
Immunity • EN61000-4-2 level 4,
EN61000-4-3, 4, 5 level 3,
EN61000-4-6 level 2
400 Watts
RTC400 Series
Compact PCI®
Specification
•
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
Intelligent Design Quality Product
XPiQ inc.
Industry Standard
•
AC or DC Input Versions
•
Power Factor Corrected
•
Hot Swap N + 1 Redundancy
•
Active Current Share
•
International Safety Approvals
•
PICMG 2.11 Compatible