XPiQ inc PD40-14HC, PD40-14LA, PD40-14LC, PD40-14MA, PD40-14MC Datasheet

...
40 Watts
PD40 Series
Low Cost
100% Burn-In
Small Size, Light Weight
Three Wide Input Voltage Ranges
10-30 VDC, 20-60 VDC, 30-90 VDC
Overcurrent Protection
Specification
All specifications typical at nominal line, full load and 25°C
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
Intelligent Design Quality Product
XPiQ inc.
DC/DC Converters
Input
Input Voltage 10 to 30 VDC
(PD40 “L” series) 20 to 60 VDC
(PD40 “M” series) 30 to 90 VDC
(PD40 “H” series)
Input Current 2.5A (rms) for 24 VDC
1.3A (rms) for 48 VDC
0.84A (rms) for 72 VDC
Output
Output Voltage/ See rating chart Current
Ripple 1% peak to peak maximum Overvoltage Provided on output #1 only,
Protection set at 112-132% of its nominal
output voltage
Overcurrent All outputs protected in short Protection: circuit conditions
Temperature All outputs ±0.04%/°C Coefficient: maximum
General
Efficiency 65% minimum Hold-up time 10 msec Line Regulation ±0.5% max Isolation Voltage 1000 VDC from input to output
Environmental
Operating 0°C to +70°C* Temperature
Storage -40°C to +85°C Temperature
MTBF 100,000 hours Weight 300 grams - PCB
500 grams - enclosed
* Derate linearly from 100% load at 50°C to 50% load at 70°C
PD 40 26/4/02 2:41 pm Page 1
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
OUTPUT VOLTAGE & CURRENT RATINGS PD 40
Notes
Mechanical Details
Pin Chart
Output #1 Output #2 Output #3 Maximum
Output
Model Vnom Imin Imax Tol. Vnom Imin Imax Tol. Vnom Imin Imax Tol. Power
2
PD40-10 5V 0.0A 8.0A 1% 40W PD40-12 12V 0.0A 3.5A 1% 40W PD40-13 15V 0.0A 3.0A 1% 40W PD40-14 24V 0.0A 2.0A 1% 40W PD40-25 +5V 0.5A 3.0A 3% +24V 0.1A 1.0A 5% 40W PD40-30 +5V 0.5A 3.0A 3% +12V 0.2A 2.0A 5% –5V 0A 0.8A 5% 40W PD40-31 +5V 0.5A 3.0A 3% +12V 0.2A 2.0A 5% –12V 0A 0.8A 5% 40W PD40-32 +5V 0.5A 3.0A 3% +15V 0.2A 2.0A 5% –15V 0A 0.8A 5% 40W
MODEL PIN 1 2 3 4 5 6
PD40-10 PD40-12 OUTPUT OUTPUT OUTPUT RETURN RETURN RETURN PD40-13 PD40-14 #1 #1 #1
PD40-25 OUTPUT OUTPUT OUTPUT COMMON COMMON N.C.
#2 #1 #1 RETURN RETURN
PD40-30 PD40-31 OUTPUT OUTPUT OUTPUT COMMON COMMON OUTPUT PD40-32 #2 #1 #1 RETURN RETURN #3
1. All multi-output units may be operated at no load without damage. At no load, output tolerance increases to 10%.
2. Maximum output power for 10-30 VDC input range is 70% of that shown above.
3. Suffix codes for mechanical format and input range as follows: Input voltage range L: .10-30 VDC
2
Mechanical format: A: PCB only M: .20-60 VDC C: Enclosed H: .30-90 VDC
Example: PD40-31MC (20-60 VDC input range/Enclosed).
Dimensions shown in inches (mm)/Tolerance ± 0.02 (0.5) maximum Input connector mates with Molex housing 09-50-3041 and Molex 2878 series crimp terminal Output connector mates with Molex housing 09-50-3061 and Molex 2878 series crimp terminal
OPEN PCB “A” ENCLOSED “C”
PD 40 26/4/02 2:41 pm Page 2
Loading...