40 Watts
PD40 Series
Low Cost
•
100% Burn-In
•
Small Size, Light Weight
•
Three Wide Input Voltage Ranges
10-30 VDC, 20-60 VDC, 30-90 VDC
•
Overvoltage Protection
•
Overcurrent Protection
•
•
•
Specification
All specifications typical at nominal line, full load and 25°C
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
Intelligent Design Quality Product
XPiQ inc.
DC/DC Converters
Input
Input Voltage • 10 to 30 VDC
(PD40 “L” series)
20 to 60 VDC
(PD40 “M” series)
30 to 90 VDC
(PD40 “H” series)
Input Current • 2.5A (rms) for 24 VDC
1.3A (rms) for 48 VDC
0.84A (rms) for 72 VDC
Output
Output Voltage/ • See rating chart
Current
Ripple • 1% peak to peak maximum
Overvoltage • Provided on output #1 only,
Protection set at 112-132% of its nominal
output voltage
Overcurrent • All outputs protected in short
Protection: circuit conditions
Temperature • All outputs ±0.04%/°C
Coefficient: maximum
General
Efficiency • 65% minimum
Hold-up time • 10 msec
Line Regulation • ±0.5% max
Isolation Voltage • 1000 VDC from input to output
Environmental
Operating • 0°C to +70°C*
Temperature
Storage • -40°C to +85°C
Temperature
MTBF • 100,000 hours
Weight • 300 grams - PCB
500 grams - enclosed
* Derate linearly from 100% load at 50°C to 50% load at 70°C
PD 40 26/4/02 2:41 pm Page 1
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xp-iq.com
Holliston, MA 01746 USA
www.XP-iQ.com
OUTPUT VOLTAGE & CURRENT RATINGS PD 40
Notes
•
Mechanical Details
Pin Chart
Output #1 Output #2 Output #3 Maximum
Output
Model Vnom Imin Imax Tol. Vnom Imin Imax Tol. Vnom Imin Imax Tol. Power
2
PD40-10 5V 0.0A 8.0A 1% 40W
PD40-12 12V 0.0A 3.5A 1% 40W
PD40-13 15V 0.0A 3.0A 1% 40W
PD40-14 24V 0.0A 2.0A 1% 40W
PD40-25 +5V 0.5A 3.0A 3% +24V 0.1A 1.0A 5% 40W
PD40-30 +5V 0.5A 3.0A 3% +12V 0.2A 2.0A 5% –5V 0A 0.8A 5% 40W
PD40-31 +5V 0.5A 3.0A 3% +12V 0.2A 2.0A 5% –12V 0A 0.8A 5% 40W
PD40-32 +5V 0.5A 3.0A 3% +15V 0.2A 2.0A 5% –15V 0A 0.8A 5% 40W
MODEL PIN 1 2 3 4 5 6
PD40-10 PD40-12 OUTPUT OUTPUT OUTPUT RETURN RETURN RETURN
PD40-13 PD40-14 #1 #1 #1
PD40-25 OUTPUT OUTPUT OUTPUT COMMON COMMON N.C.
#2 #1 #1 RETURN RETURN
PD40-30 PD40-31 OUTPUT OUTPUT OUTPUT COMMON COMMON OUTPUT
PD40-32 #2 #1 #1 RETURN RETURN #3
1. All multi-output units may be operated at no load without damage. At no load, output tolerance increases to 10%.
2. Maximum output power for 10-30 VDC input range is 70% of that shown above.
3. Suffix codes for mechanical format and input range as follows:
Input voltage range L: .10-30 VDC
2
Mechanical format: A: PCB only
M: .20-60 VDC C: Enclosed
H: .30-90 VDC
Example: PD40-31MC (20-60 VDC input range/Enclosed).
Dimensions shown in inches (mm)/Tolerance ± 0.02 (0.5) maximum
Input connector mates with Molex housing 09-50-3041 and Molex 2878 series crimp terminal
Output connector mates with Molex housing 09-50-3061 and Molex 2878 series crimp terminal
OPEN PCB “A” ENCLOSED “C”
PD 40 26/4/02 2:41 pm Page 2