PRELIMINARY
Q3 2003
12 Volt Intermediate BUS for DPA
•
96% Efficiency
•
Low Cost
•
12 Volt / 25 Amp Quarter Brick
•
Low Profile 0.43”
•
International Safety Approvals
Input
Input Voltage Range • 42-53 VDC
Input Current • 5.90 A max at 42 VDC
6.63 A max at 53 VDC
Input Reflected • 5 mA pk-pk
Ripple
Remote On/Off • Shorted to -Vin (Logic Low) = ON
Open (Logic high) = OFF
Positive logic is available
Input Reverse Voltage • External components required
Protection
Undervoltage lockout • Below 37.6 to 40.7 VDC = OFF
Above 40.9 to 44.2 VDC = ON
Output
Output Voltage • 12 VDC
Minimum Load • No minimum load required
Line Regulation • ±1.3 V
Load Regulation • ±500 mV
Setpoint Accuracy • ±50 mV
Ripple & Noise • 120 mV pk-pk maximum
Transient Response • 200mV max deviation, 100 µs recovery
time for a 25% load change
Temperature • 0.01%/°C
Coefficent
Overvoltage • 14.9 V non-latching, hiccup mode
Protection
Overcurrent • 110-130% auto restart
Protection
Overtemperature • Shutdown at 120 °C auto restart
Protection
General
Efficiency • 96%
Isolation • 1500 VDC input to output
Size • 2.30” x 1.45” x 0.43”
(without baseplate)
Package Style • Open frame, baseplate option
Weight • 42 g for open frame
Environmental
Operating • -40 °C to +85 °C ambient
Temperature See Derating Curve
(with 200 LFM) Full power to +55 °C
Storage Temperature • -55°C to +125°C
Humidity • 5-95% RH non-condensing
EMC & Safety
Safety Approvals • UL60950, EN60950,
CSA 60950 per cUL,
CE Marked for LVD
EMI/EMC • FCC level B Part 15 with
external filtering
25 Amps
KIQ025 Series
Quarter Brick DC/DC Converters
Specification
•
•
•
Intelligent Design Quality Product
XPiQ inc.
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
* Preliminary datasheet - see website for current specs