XPiQ inc JPM120PS13R, JPM120PS13, JPM120PS12R, JPM120PS12, JPM120PS07 Datasheet

...
Input
AC Input Voltage 85-264 VAC Input Frequency 47-63 Hz DC Input Voltage 120-370 VDC Power Factor 0.98 at 115 VAC, 0.96 at 230 VAC Input Current 2.2 A max at 115 VAC Inrush Current 40 A at 230 VAC cold start Start-Up time 600 ms Rise Time 30 ms
Output
Output Voltage 3.3 V to 48 V single outputs Output Power 120 Watts, see table Output Voltage +10%, -5%
Adjustment Minimum Load 0 minimum load required Tolerance ±2% max Line Regulation ±0.5% Load Regulation ±1% max, see table Ripple & Noise 100mV typical, see table Transient Response 5% max deviation, 500 µs
recovery time for a 50% load change
Temperature 0.05%/°C Coefficient
Hold Up Time 20 ms minimum at 230 VAC Overvoltage 110-135 %
Protection Overcurrent 140-170%, constant current
Protection auto restart
General
Efficiency • See Table MTBF 100,000 hrs min Leakage Current <2 mA at 240 VAC Isolation Voltage 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground Size 199 x 99 x 50 mm Weight 750 grams
Environmental
Operating -10 °C to +50 °C Temperature (see derating curves)
Cooling Convection cooled Humidity 20-90% RH non condensing Storage -20 °C to +85 °C
Temperature Shock & Vibration 10-500 Hz 2G 10 min/cycle
for 60 min each axis
Safety and EMC
Safety UL1950, CSA C22.2 No 950
per cUL EN60950, CE Mark LVD EMI/EMC Meets EN61000-3-2, -3, ENV50204,
CISPR22 (EN55022) Class B Immunity & Surge Meets EN61000-4-2, -3, -4,
-5, -6, -8, -11
120 Watts
JPM120 Series
AC/DC Industrial Type
Specification
Intelligent Design Quality Product
XPiQ inc.
CE Marked LVD
Low Cost
High Reliability
Power Factor Corrected
Low Ripple Noise
Adjustable Output
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
Output Output Output Ripple & Noise Load Regulation Efficiency Model
Voltage Current Power
(1)
(Pk-Pk) Number
(2,3)
3.3 V 24.0 A 79 W 100 mV ±1.0% 67% JPM120PS03
5.0 V 24.0 A 120 W 100 mV ±1.0% 75% JPM120PS05
7.5 V 16.0 A 120 W 100 mV ±1.0% 79% JPM120PS07
12.0 V 10.0 A 120 W 100 mV ±0.5% 80% JPM120PS12
13.5 V 8.9 A 120 W 100 mV ±0.5% 80% JPM120PS13
15.0 V 8.0 A 120 W 100 mV ±0.5% 81% JPM120PS15
24.0 V 5.0 A 120 W 150 mV ±0.5% 83% JPM120PS24
27.0 V 4.4 A 120 W 150 mV ±0.5% 84% JPM120PS27
48.0 V 2.5 A 120 W 250 mV ±0.5 % 84% JPM120PS48
Mechanical Details - 120 Watts
Derating Graph 120 Watts
Dimensions (mm)
TERMINAL Pin No.Assignment
PIN 1,2: AC Input Pin 3: FG Pin 4,5: DC Output -V Pin 6,7: DC Output +V Weight: approx 750 grams
Notes
1. Max output increases to 125% of rated power when input voltage is between 180 VAC to 264 VAC and ambient temperature is less than 40°C convection cooled or 47°C with 18°CFM airflow.
2. Part numbers in bold type are standard stock models, all others are build to order.
3 For optional Remote On/Off, add suffix “R” to part number. Example: JPM120PS03R On=3~15VDC, Off=<3VDC
OUTPUT VOLTAGE & CURRENT RATINGS JPM120
Optional Mounting Tabs in 4 places. Consult factory for details
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
Loading...