Input
AC Input Voltage • 85-264 VAC
Input Frequency • 47-63 Hz
DC Input Voltage • 120-370 VDC
Power Factor • 0.98 at 115 VAC, 0.96 at 230 VAC
Input Current • 2.2 A max at 115 VAC
Inrush Current • 40 A at 230 VAC cold start
Start-Up time • 600 ms
Rise Time • 30 ms
Output
Output Voltage • 3.3 V to 48 V single outputs
Output Power • 120 Watts, see table
Output Voltage • +10%, -5%
Adjustment
Minimum Load • 0 minimum load required
Tolerance • ±2% max
Line Regulation • ±0.5%
Load Regulation • ±1% max, see table
Ripple & Noise • 100mV typical, see table
Transient Response • 5% max deviation, 500 µs
recovery time for a 50% load change
Temperature • 0.05%/°C
Coefficient
Hold Up Time • 20 ms minimum at 230 VAC
Overvoltage • 110-135 %
Protection
Overcurrent • 140-170%, constant current
Protection auto restart
General
Efficiency • See Table
MTBF • 100,000 hrs min
Leakage Current • <2 mA at 240 VAC
Isolation Voltage • 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground
Size • 199 x 99 x 50 mm
Weight • 750 grams
Environmental
Operating • -10 °C to +50 °C
Temperature (see derating curves)
Cooling • Convection cooled
Humidity • 20-90% RH non condensing
Storage • -20 °C to +85 °C
Temperature
Shock & Vibration • 10-500 Hz 2G 10 min/cycle
for 60 min each axis
Safety and EMC
Safety • UL1950, CSA C22.2 No 950
per cUL EN60950, CE Mark LVD
EMI/EMC • Meets EN61000-3-2, -3, ENV50204,
CISPR22 (EN55022) Class B
Immunity & Surge • Meets EN61000-4-2, -3, -4,
-5, -6, -8, -11
120 Watts
JPM120 Series
AC/DC Industrial Type
Specification
•
Intelligent Design Quality Product
XPiQ inc.
CE Marked LVD
•
Low Cost
•
High Reliability
•
Power Factor Corrected
•
Low Ripple Noise
•
Adjustable Output
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com