XPiQ inc IFC125-42-3, IFC125-14, IFC125-40-1 Datasheet

Active PFC - Meets EN61000-3-2, -3
Small Size 3.0” x 5.0” x 1.25”
Single, Triple & Quad Outputs
Overvoltage & Overcurrent Protection
Power Fail Detect
International Safety Approvals
AC Input Voltage 90-264 VAC Input Frequency 47-63 Hz Power Factor 0.98 typical Inrush Current 24 A max at 100 VAC Input Current 0.8 A max at 240 VAC
1.8 A max at 100 VAC
Output
Output Voltage See Table Output Power 125 Watts Minimum Load 5 W minimum load on any output
or combination of outputs required
to maintain regulation Line/Load Regulation • See Table Ripple and Noise ±2% pk-pk maximum
> = 5 V out ±1% maximum Transient Response 5% max deviation, recovering
to a 1% of final value in less than
500 µs after a 25% load change Temperature 0.04%/°C maximum
Coefficient Hold up Time >28 ms minimum at full load Overvoltage V1 & V2: 113% to 148% recycle input
Protection to reset Overcurrent All outputs 115% to 135% with
Protection auto recovery Remote Sense V1 only compensates for 0.5 V drop
Not Available on IFC125-31
General
Efficiency 83% typical Power Density 6.66 W/in
3
MTBF >220,000 hours per Bellcore Isolation Voltage 3000 VAC Input to Output
1500 VAC Input to Ground
500 VAC Output to Ground Signals Power Good - On = Logic Hi Size 5.00” x 3.00” x 1.25” Weight 312 grams approx.
Environmental
Operating -25 °C to +70 °C derate linearly from Temperature 100% load at +70 °C to 50% load
at +50 °C Cooling 5 CFM forced air required for 125 W Humidity 5-95% RH, non-condensing Storage Temperature • -40 °C to +85 °C
EMC & Safety
Safety Approvals UL60950, CSA22.2: 60950 per cUL,
EN60950, CE mark LVD EMI/EMC Meets EN61000-3-2, -3
EN55022/CISPR22 Class B and FCC
Class B conducted
125 Watts IFC125 Series
AC/DC Open Frame
Specification
Intelligent Design Quality Product
XPiQ inc.
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
OUTPUT VOLTAGE & CURRENT RATINGS IFC125
Mechanical Details
Notes
1. Total regulation includes tolerance, line regulation and load regulation.
2. Maximum output power not to exceed 125 W with 5 CFM forced air or 70 W with convection cooling.
3. For models IFC125-40-1 and -42-3, a maximum of 80 W combined +2.5 V or +3.3 V and +5 V outputs with 5 CFM of forced air cooling or 40 W with convection cooling.
4. 5 W minimum load required to maintain regulation.
Output 1 Output 2 Output 3 Output 4 Model
Vnom Imax Reg
(1)
Vnom Imax Reg
(1)
Vnom Imax Reg
(1)
Vnom Imax Reg
(1)
Number
24.0 V 5.2 A ±3% 12.0 V 0.5 A ±5% IFC125-14
5.0 V 16.5 A ±4% 12.0 V 5.0 A ±5% -12.0 V 0.5 A ±5% IFC125-31
2.5 V 12.5 A ±2% 5.0 V 15.0 A ±4% 12.0 V 5.0 A ±5% -12.0 V 0.5 A ±5% IFC125-40-1
3.3 V 10.0 A ±2% 5.0 V 15.0 A ±4% 12.0 V 5.0 A ±5% -12.0 V 0.5 A ±5% IFC125-42-3
Pin 1 Neutral Pin 2 Missing Pin Pin 3 Line
J1-AC Input Connector
All models.
PH: 508 429.9883
FAX: 800 226.2100
Email: sales@xpiq.com
Holliston, MA 01746 USA
www.XPiQ.com
Mechanical Drawing for IFC125-31, -40-1 and -42-3 only. See next page for IFC125-14
J2 - DC Output Connector
IFC125-31 IFC125-40-1 IFC125-42-3 Pin 14 +5 VDC +5 VDC +5 VDC Pin 13 +5 VDC +5 VDC +5 VDC Pin 12 +5 VDC +5 VDC +5 VDC Pin 11 +5 VDC +5 VDC +5 VDC Pin 10 DC GND DC GND DC GND Pin 9 DC GND DC GND DC GND Pin 8 DC GND DC GND DC GND Pin 7 DC GND DC GND DC GND Pin 6 DC GND DC GND DC GND Pin 5 Not Used. +2.5 VDC +3.3 VDC Pin 4 Not Used. +2.5 VDC +3.3 VDC Pin 3 Not Used +2.5 VDC +3.3 VDC Pin 2 +12 VDC +12 VDC +12 VDC Pin 1 -12 VDC -12 VDC -12 VDC
IFC125-31 IFC125-40-1 IFC125-42-3 Pin 1 0V Sense 0V Sense 0V Sense Pin 2 Not Used +2.5 V Sense +3.3 V Sense Pin 3 Power Good Power Good Power Good
J3-Remote Sense
& Power Good Connector
NOTE: J3-1 must be connected to DC GND at output or at load. J3-2 must be connected to Output 1 at the output or load
IFC125-31 IFC125-42-3
&-40-1
J1 Housing 09-50-8031 90-50-8033
Pins 08-52-0113 08-52-0113
J2 Housing 09-50-8141 09-50-8143
Pins 08-52-0113 08-52-0113
J3 Housing 22-01-3037 22-01-3037
Pins 08-50-0114 08-50-0114
Mating Connectors
with Molex part numbers
Loading...