User Manual - INTRODUCTION
TAG LINK
The eXI Tag Link device automates tag administration by providing a localized
eLink between the Halo or Assetrac application software and the targeted tag
device.
The Tag Link communicates directly with the system computer through a serial
port and may be powered by an internal 9 volt battery or accessory AC wall
adapter. The Tag Link enables the software application to transparently interact
with the tags.
Tag Link Views
PHOTO ILLUS: TAG LINK WITH PTAG
WITH LED HIGHLIGHTED
PHOTO ILLUS: TAG LINK WITH MOTHER TAG
Copyright 2003 - eXI Wireless Systems Inc. Page XX 980-000003 – 002. R1.01
![](/html/c0/c0eb/c0ebcbe58b17550a1269bfdd5cdf5c4b0c59ea168a2e555ec699a24ce55ac52d/bg2.png)
User Manual - INTRODUCTION
Tag Link Range
The communication range for Tag Link is designed to be typically less than 12
inches. Therefore, it is recommended that the tags be located within 6 to 12
inches of Tag Link. Those tags with ‘off body’ sensor must be placed on the front
panel in the marked area. This will assure that the alarm TIC message is not
transmitted.
Tag Link Functions
The following table lists the functions that are performed transparently in
response to commands from the application software:
COMMAND TAG LINK ACTION LED
Power Up Powers up from sleep mode
Power Down Return to sleep mode immediately or after 30
seconds if no application command
Check RF Noise Measures and reports interference at 307 kHz
Measures and reports interference at 433.92 MHz
Test Tag TIF Interrogates tag and returns ID and tag status
Test Tag TIC Tag Link waits for TIC signal from specified tag
Set TLM Tag Link issues eLink TLM set command
Disable TLM Tag Link issues eLink TLM disable command
Check TLM Tag Link queries tag and reports rate to application
Assign MTAG Reads Mother Tag ID and assigns dynamic ID
MTAG Bond Sends baby tag ID(s) to Mother Tag, Mother Tag is
then bonded to the assigned tag(s)
none
none
Green Flashes
Red Flashes
See next table
See next table
See next table
See next table
See next table
See next table
See next table
Each operation is performed for a maximum of 10 seconds. During application
the following audio-visual signals are output:
ACTION BEEPER LED’s
Command received Very short beep None
Command succeeded Longer beep random
Command failed 4 short beeps
Copyright 2003 - eXI Wireless Systems Inc. Page XX 980-000003 – 002. R1.01
Both briefly on