XL Microwave 3400A Data Sheet

Page 1
product data
Ultimate frequency counting
Simultaneous Frequency and Power
l
measurements Wide frequency range from 10 Hz to
l
60 GHz Compact, portable, rugged and battery
l
operated High stability Oven-controlled Crystal
l
timebases and ultra-stable Rubidium option
Short acquisition time (<60ms)
l
5 year warranty
l
Outstanding performance/price ratio
l
XL 3000-series
Microwave Frequency Counters
Perfect solution in the field...
The 3000-series of combined microwave counters and power meters, providing simulta­neous measurement of both frequency and power, suits both field, lab bench and test rack environments.
For field applications like installation, mainte- nance and calibration of microwave links, ra­dar CW, microwave transmitters, DAB or DTV links, satellite ground stations or radio base stations, the models in the 3000-series give you ultra-high accuracy in a portable compact, lightweight and rugged design. A weather-resistant instrument back-pack is in cluded.
Atomic clock accuracy in a true portable for mat: You can bring cal lab accuracy out into
the field thanks to an integrated rubidium or high-stability OCXO oscillator. Since both frequency and power verification are standard measurements in field installation and mainte nance, you can have both instruments in one box, meaning less to carry around. The same input connector is used for both measure ments, which simplifies operation. An optional battery pack is used in environments where no AC power is available, or to keep an OCXO continuously heated during transport for opti mum performance. The battery typically pro vides over 3 hours of continuous operation and automatically charges whenever the counter is connected to the AC mains.
Very Easy to Use: To eliminate operator mis takes, the instruments are very easy to use and require no costly training. The front panel controls are self-explanatory and the read out of result is unambiguous due to the bright LED display which ensures full visibility, whether in full sunlight or in the dark.
Lower operating costs than any competitive solution: In addition to the very affordable
mm frequency counter, a power meter and a fre
quency reference. purchase price, the instruments are very dura­ble and reliable, and will give you trouble-free operation year after year. A 5 year warranty comes with each instrument.
...or on the bench
For bench ant test systems applications like R&D, Service, incoming inspection, quality control and manufacturing test of RF compo­nents, systems or subassemblies, microwave transmitters/receivers, radar equipment etc, the models in the 3000-series gives you ultra-high
­performance and remote GPIB connectivity.
Three instruments in one: Measurements are
-
accurate and fast, with less than 60 ms acquisi tion time. With the Rubidium oscillator option, you will not only get a high-accuracy micro wave counter, but also a 10 MHz reference output frequency for the local lab or for the
­ATE-rack, where you can supply other instru
Oscillator Options
A wide choice of internal time base oscillators are available; the standard TCXO oscillator, two high stability OCXO oscillators, and a Rubidium Fre­quency Standard. Please see table below for specs.
Telecommunication professionals often have a re­quirement to measure and verify base station ref­erence oscillators at remote sites. These base station oscillators must be calibrated very accuratly. The optional internal Rubidium Fre quency Standard, along with the standard 0.01 Hz resolutioninBand1meetsthisrequirement,by
-
displaying accurate digits in only 10s.
The Rubidium option counters require four min
­utes of warmup time and provide measurements
only when fully stable - accuracy and reliabilty you can count on!
-
ments with an atomic frequency standard. In Test Systems you save valuable space by inte
­grating three instruments in one package; a
Oscillator Options Available Standard
-
Short term stability: 5.1x10
-
Aging/day: n.s. 3x10
Aging/month: n.s. n.s. n.s. 5x10
Aging/year:
-
Warm-up (time): @ 25°C 4x10-7in 5 min. 1x10-8in 20 min. 5x10-8in 5 min. 5.1x10
Temperature: (0°C to 50°C)
MAINS change: (±10%)
TCXO (Note 1)
-9
(t=1s, Allan Dev.)
7
-
(after 45 days)
7.6x10
-6
1x10
-9
5x10
Note 1: The standard TCXO oscillator is installed in the basic unit unless an optional oscillator is selected.
Note 2: Selection of Rubidium Oscillator Option 125 extends the counter chassis depth from 333 mm (13.1 in.) to 368
mm (14.5 in.). Rubidium Oscillator Option 125 is not available with Battery Option 150 counters.
-
Option 112 OCXO
-10
5x10 (t=1s, Allan Dev.)
-9
-7
5x10
-8
1x10
-9
1x10
Option 120 OCXO
-12
5x10 (t=1s, Allan Dev.)
-10
4x10
1x10-7(after 30 days) 2x10
-9
7x10
-9
2x10
Option 125 Rubidium (Note 2)
-11
1.4x10 (t=1s, Allan Dev.)
n.s.
-11
-10
-10
after 4 min.
-10
after 10 min.
1x10
-11
2x10
after 60 min.
-11
3x10
N/A
-
-
-
Page 2
Technical Specifications
Measuring modes
Frequency Band 1
Range: 10 Hz to 120 MHz (model 3120, 3200,
Resolution: 0.01 Hz, 1 Hz
Accuracy: ±1 count, ±time base accuracy
Frequency Band 2
Range: 120 MHz to 12.4/20/26,5 GHz (model
Resolution: 1 Hz to 1 MHz in decade steps
Accuracy: ±1 count, ±time base accuracy
Power Band 2
Frequency range: Full frequency range (band 2)
Power range: -35 to +10 dBm
Resolution: 0.1 dBm
Accuracy: ±1 dBm to 26.5 GHz, typical
Measurement time: Freq. meas. time +15 ms
Band 1 Specifications
Band 1 Input; 1/1 M
Frequency range: 10 Hz to 120 MHz (model 3120, 3200,
Sensitivity: 25 mVrms
Dynamic range: 25 mV to 1 Vrms
Coupling: AC
Impedance:
Damage level: 250 VAC+DC to 400 Hz, decreasing to
Connectors: BNC female
Band 1 Input; 1/50 M
(Models 40 GHz and above: 3400A, 3460A&3600)
Frequency range: 50 Hz to 250 MHz
Sensitivity: -25 dBm
Dynamic range: -25 dBm to +10 dBm
Coupling: AC
Impedance:
Damage level: +25 dBm
Connectors: BNC female
Band 2 Specifications
Common Specs
(Models 3120, 3200, 3260, 3400A, 3460A, 3600)
Dynamic range: Min. sens. to +10 dBm
Coupling: AC
Impedance:
Automatic Amplitude Discrimination:
Integrated Kickback noise:- -50 dBm typical
AM tolerance: Any modulation index, provided the
FM tolerance: 20 MHz P-P
Signal acquisition time: <60 ms
Damage level: +25 dBm (for mod 3600 +23 dBm)
VSWR: 2:1 typical (mod 3120/3200/3260)
Overload indicator:
3260); 10 Hz to 100 MHz (model 3400A, 3460, 3600; 1 MΩ); 50 MHz to 250 MHz (model 3400A, 3460, 3600; 50)
3120, 3200, 3260); 200 MHz to 40/46/60 GHz (model 3400A, 3460A, 3600)
±2 dBm to 26.5-40 GHz, typical ±3 dBm at 60 GHz, typical
3260) 10 Hz to 100 MHz (model 3400A, 3460A, 3600)
1MΩ/25 pF
5V at 1 MHz; 5V from 1 MHz to 120 MHz
50nom.
50nom.
10 dB separation between 2 signals within 30 MHz, 20 dB otherwise
minimum signal is not less than the sensitivity spec.
3:1 typical (mod 3400A/3460A/3600)
On at +10 dBm nom. to 26.5 GHz, increasing to +15 dBm at 46 GHz, to +20 dBm at 60 GHz
Model 3120 (12.4 GHz)
Frequency range: 120 MHz to 12.4 GHz
Sensitivity: -30 dBm
Connectors: N female
Model 3200 (20 GHz)
Frequency range: 120 MHz to 20 GHz
Sensitivity: -25 dBm
Connectors: N female
Model 3260 (26.5 GHz)
Frequency range: 120 MHz to 26.5 GHz
Sensitivity: -25 dBm
Connectors: SMA female plug
Model 3400A (40 GHz)
Frequency range: 200 MHz to 40 GHz
Sensitivity: -30 dBm to 26.5 GHz
Connectors: 2.92 mm female plug
-25 dBm to 40 GHz
Model 3460A (46 GHz)
Frequency range: 200 MHz to 46 GHz
Sensitivity: -30 dBm to 26.5 GHz
Connectors: 2.92 mm female plug
-20 dBm to 46 GHz
Model 3600 (60 GHz)
Frequency range: 200 MHz to 60 GHz
Sensitivity: -25 dBm to 40 GHz
Connectors: 1.85 mm female plug
-15 dBm at 60 GHz (-20 dBm at 60 GHz typ)
Additional Technical Data
General
Gate time: 1s, 0.1s, 0.01s & 1.0 ms
Display time: 0.3 s, 3.0 s, Infinite, & Min
Self-test: All digits segments, all LED’s, 10 MHz
Display: 11 digits/0.5 ’’ high LED, Overload,
Display legend: Hz, kHz, MHz, GHz & dBm
Status indicators:
F:
GPIB (IEEE 488 Std-1978)
Programmable:
Functions/Controls:
Environmental
Operating temp: 0°Cto50°C (std CW)
Storage temp: -40°Cto71°C (std CW)
Relative humidity:
Vibration limits: 2g
Burn-In: Failure-free burn-in of no less than 100
Pollution degree: 1 (no pollution) (EN 61010-1)
Transient overvoltage: Install. Cat II (EN 61010-1)
Cooling: Microwave counters do not contain nor
Mechanical
Power DC: 11-28 VDC; 20 VA (Std. CW); 12-28
clock, & GPIB address
decimal point & sign. Simultaneous displays Frequency (with 0.1 MHz resolution) and Power.
BAND 1, (or BAND 1/1 M, BAND 1/50), BAND 2, EXT REF, DISPLAY TIME, REMOTE, GATE, F, OVERLOAD (band 2 only), POWER METER (band 2 only), & STANDBY
Difference between stored and measured frequency
BAND 1, (or BAND 1/1 M, BAND 1/50), BAND 2, RESET, TEST, F
DISPLAY TIME, POWER METER, STANDBY & RESOLUTION
-0°Cto40°C (battery operation)
-10°Cto40°C (battery operation)
95% ±5%, 10°C to 30°C; 75% ±5%, to
40°C; 45% ±5%, >40°C
hours at 40°C
require a cooling fan
VDC (Opt. 150); 18-28 VDC (Opt. 125)
Power AC MAINS: 90-130 VAC or 180-265 VAC,
Weight Net: 3.6 kg (8 lbs.)/Battery Option 5 kg.
Weight Shipping: 5.5 kg (12 lbs.)/Battery Option 6.8
45 Hz-440 Hz; 25 VA
(11 lbs)
kg. (15 lbs)
Internal/External Reference Oscillator
10 MHz ref osc out:
Ext ref osc in:
Connectors (IN/OUT): BNC female (rear panel)
10 MHz, 1 Vrms into 5
2, 5 or 10 MHz/>0.2 Vrms/1 k
Reliability
MTBF: >32,000 hours (MIL-HDBK-217E)
MTTR: 30.92 minutes (MIL-HDBK-472)
Standards Compilance
EC (European Union):
EMC Emissions: Certified to EN 55022:1987 Class B EMC Immunity: Certified to EN 50082-1:1992 Safety (LVD): Complies with EN 61010-1
ISO 9001:
The Quality System for design and manufacture is registered and certified by TUV Essen to IS
Montreal Protocol: Nil return
Ordering Information
Basic models
3120 Frequency counter 10 Hz to 12.4 GHz
3200 Frequency counter 10 Hz to 20 GHz
3260 Frequency counter 10 Hz to 26.5 GHz
3400A Frequency counter 10 Hz to 40 GHz
3460A Frequency counter 10 Hz to 46 GHz
3600 Frequency counter 10 Hz to 60 GHz
Accessories Included
1. One (1) Operating/Maintenance manual
2. One (1) AC power cord, 2 meters
Options/Accessories
150 Battery Option, rechargeable sealed lead/acid
battery (3h op time)
170 Rack Ears, RETMA (HxW) 88.9 mm x 482.6
mm (3.5’’x 19’’)
213 Factory Calibration of microwave counters with
TCXO oscillators
214 Factory Calibration of microwave counters with
OCXO oscillators
302 Hard shell Case
326 Watertight Case, for severe environmental
conditions
336 Weather-Resistant Instrument Back-Pack
320 Spare Battery, 12V/2.3 Ah Rechargable
305 Spare Operating and Maintenance Manual
315 Adapter: V (m) to K (f)
(model 3600 only)
316 Adapter: V (f) to WR15
(model 3600 only)
317 Adapter: V (f) to WR19
(model 3600 only)
318 Coax cable, 0.5 m V (m) to V (m) (<60 GHz)
319 Coax cable, 1.0 m V (m) to V (m) (<60 GHz)
Specifications subject to change without notice
4031 630 00121 - rev. 06 March 2004
US: Pendulum Instruments Inc
5811 Racine Street Oakland, CA 94609-1519, USA Voice:(510)-428-9488 Fax: (510)-428-9469
International: Pendulum Instruments AB
PO Box 20020, SE-16102 Bromma, Sweden Voice: +46 8 598 51057 Fax:+46 8 598 51040
Pendulum Instruments www.pendulum-instruments.com
- Experts in time & frequency calibration, measurement and analysis
Loading...