![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg1.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
Upper-arm Wireless Blood Pressure Monitor
User Manual
Type: MUMU-BP2 (Arm-type)
Thank you for choosing a MUMU product, Just in case that you are facing any problems
with your device, please contact us:
Xiamen Firstmed Medical Technology Co., LTD
East of 3rd Floor , No.4 Zhonghangji Building, No.1 Huli Avenue,Huli District, Xiamen
Service hotline: 400 999 2781
Service E-mail:service@mymumu.com
www.mymumu.com
Page 1
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg2.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
Content
Introduction
1 Preparation
1.1 Safety precautions…………………………………………………4
1.2 Composition of product……………………………………………9
1.3 Name of components………………………………………………10
1.4 Application method of blood pressure monitor……………………13
2 Measuring method
2.1 Mobile software installation…………………………………………15
2.2 Blood pressure measuring……………………………………………16
2.3 Historical Data Display………………………………………………19
2.4 Cloud Storage………………………………………………………20
2.5 Other Functions of Mobile Software………………………………21
3 FAQ & Maintenance
3.1 Q&A for blood pressure measurement………………………………22
3.2 Troubleshooting………………………………………………………26
3.3 Maintenance and storage……………………………………………28
3.4Specifications…………………………………………………………29
3.5 Cleaning………………………………………………………………30
3.6 Statement……………………………………………………………31
3.7 Warranty Information………………………………………………32
3.8 Symbol………………………………………………………………37
Page 2
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg3.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
Introduction
Thank you for purchasing and using the series products of MUMU-BP
blood pressure monitor. In order to ensure safe usage of this product and
make it to be your best assistant for daily blood pressure management, we
advise you to read this manual carefully before using the monitor. Please
take care of the attached warranty card.
Intended Use
This compact and convenient monitor is an ideal device for people
who need to measure their systolic and diastolic blood pressures and pulse
rate frequently. It is only designed for adults use, and the range of the cuff
circumference is 17cm-42cm(3 cuff sizes available, please refer to the size
you chose).
After installation of our mobile software on your iOS or Android smart
devices, the monitor will connect to your device via bluetooth and you can
measure the blood pressure. Push a button on the device, then the
measurement of blood pressure and pulse begins, and the results will be
displayed on your device. The results can be stored in your device or
uploaded to the cloud for permanent storage and management. No matter
at home or in the office, you can easily and quickly measure, browse and
share the historical data.
Page 3
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg4.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
Read all information in the instruction manual and any other
Self-judgment might possibly lead to exacerbation of diseases.
Diabetes, hyperlipidemia and high blood pressure, etc. can expedite
It is not recommended for people with serious arrhythmia to use
Please do not use the monitor for other purposes except blood
Please do not dismantle or repair by yourself, or modify this monitor
1.1 Safety Precautions
To assure the correct use of the product basic safety measures
Indicates a potentially hazardous situation should always be followed
including the precautions listed below:
Since the self-judgment and self-treatment based on the
measurement results are dangerous, please follow the doctor’s
instructions.
literature included in the box before using the unit.
arteriosclerosis and even lead to peripheral circulation disturbance,
etc. Patients with these diseases might have various measuring
results of upper-arm blood pressure.
this MUMU BPM-2.
pressure measurement.
and cuff.
Page 4
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg5.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
The product is made of precise components and parts. It should be
Please use soft dry cloth to clean the product. Do not use diluents,
Avoid over-folding the armlet and over-twisting the gas tube (for
The operator shall not touch the output of battery/ USB port when
As the product and armlet are not waterproofing, please avoid rain,
If the product is used close to TV, microwave oven, X-ray or other
The product, its components and parts, and batteries cannot be
This product applies only to adults.
Consult your doctor for any of the following situations:
1. The application of the cuff over a wound or inflamed area.
avoided from high/low temperature, humidity, direct sunlight,
vibration and dusty environment.
alcohol, gasoline or wet cloth to scrub it.
desk-type MUMU-BP1) so as to ensure the service life of the
accessories.
using
sweat or water.
devices with strong electromagnetic field, the precision of
measurement will possibly be affected.
discarded as normal domestic wastes. The local applicable laws
should be followed.
Page 5
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg6.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
2. The application of the cuff on any limb with intravascular access
3. The application of the cuff on the arm on the side of a
4. Simultaneous use with other medical monitoring equipment on
5. The blood circulation of the user needs to be checked.
1. This MUMU-BP2 is designed for adults and should never be used on
2. Please do not share the cuff with any infectious person to avoid
or therapy, or an arterio-venous(A-V) shunt.
mastectomy.
the same limb.
Note:
infants, young children, pregnant or pre-eclamptic patients.
cross-infection.
Caution: The user is cautioned that changes or modifications not
expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
Page 6
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg7.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of
the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for
an uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
Page 7
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg8.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
1. MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding
2. Wireless communications equipment such as wireless home network
EMC Guidance
EMC and needs to be installed and put into service according to the
EMC information provided in the ACCOPANYING DOCUMENTS
device, mobile phones, coreless telephones and their base stations,
walkie-talkies can affect this equipment and should be kept at least a
distance d=3,3 m away from the equipment.
(Note: As indicated in Table 6 of IEC60601-1-2: 2007 for ME EQUIPMENT, a
typical cell phone with a maximum output power of 2 W yields d=3,3 m at
an IMMUNITY LEVEL of 3V/m)
Page 8
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bg9.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
1.2 Composition of product
All products have been packaged. Please open the packing cases and
make sure whether they are complete.
MUMU-BP2
USB Cable
Storage Bag
Page 9
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bga.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
1.3 Name of components
Page 10
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bgb.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
Status of indicator light (MUMU-BP1/MUMU-BP2)
Charging port (MUMU-BP2)
1. Do not change the battery. If the battery can no longer be charged,
2. Overcharging the battery may reduce its lifetime.
Status of power light
Connection to external power
Low battery voltage
(less than 20% of full battery)
Battery voltage between 20%
and 100%
Full power (100%) Green light on Green light on
Power off Refer to above status Off
Red light flashing Red light on
Green light flashing Green light on
Non-connection to external
Status of Bluetooth indicator light
Non-connection to external
Power off off
Waiting to connect to cell
phone
Connection to external power
Blue light flashing
power
power
Connected to cell phone Blue light on
The monitor has one Micro USB interface for charging. It requires
DC5V/1.0A input. Generally, the smart mobile phone charger that has
Micro USB port and DC5V/1.0A output can be used to charge this monitor.
Please DO NOT use the monitor to measure during charging.
Note:
please contact customer service.
Page 11
![](/html/fc/fcf7/fcf7838bf7cae2e0e5af356698a3e86b680f495d66391e8df800a00116f70c99/bgc.png)
MUMU-BP Blood Pressure Monitor Manual V0.5
3. Do not replace the battery by inadequately trained personnel
4. If the AC adapter is abnormal, please change the adapter.
5. The monitor, cable, battery and cuff must be disposed of according
which could result in a hazard such as a fire or explosion.
to local regulations at the end of their usage.
Page 12