X-GLOO 4x4, 5x5, 8x8, 6x6 User Manual

EN
USERS MANUAL
WINDECKSTR. 4 | 83250 MARQUARTSTEIN - GERMANY
Tel. +49(0) 86 41- 69 48 - 60 | www.x-gloo.com | info@x-gloo.com
THANK YOU FOR YOUR TRUST
2
If you loan your X-Gloo Event Tent to another person, please pass on these instructions and make sure that the person is fully advised regarding the technical aspects of the X-Gloo Event Tent, in order to avoid faulty operation.
Skywalk GmbH & Co. KG - Windeckstraße 4 - 83250 MARQUARTSTEIN | GERMANY
If you have any further questions, we are always happy to assist you:
Service Hotline +49 (0)8641-6948-60
TABLE OF CONTENTS
TECHNICAL DATA 4
STANDARD DELIVERY 5
SPECIAL INSTRUCTIONS 6
SETUP 8
1. Lay out the Matrix ..........................8
2. Test the Valves
3. Inflate Inflation with the Hand Pump
Inflation with the Electric Pump
Bravo OV10/Bravo 2000
Inflation with the Bravo
Turbo Max 12 V for car battery
Setup using the Protection Foil
............................................8-9
.................................8
..........8
....................8
.........8
........9
STABILISATION 10
Stabilisation with Water Ballasts .. 10 Stabilisation with Sand Ballasts Stabilisation with
Water Ballast Barrels Stabilisation with the
Anchoring Set
........................ 12
.................................... 13
.... 11
ELEMENTS 14
Side Walls ........................................... 14
Tunnel Part Canopy and Canopy Banner LED Lighting Kit
......................................... 16
............. 16
................................ 17
BLOCK-BUILDING SYSTEM / X-GLOO MATRIX 18
TAKEDOWN 20
CLEANING 20
REPAIR 21
Bladder Repair ................................... 21
Replacement of the Protection Strip
Bladder Replacement
................................. 21
....................... 22
X-RELAX 25
Tel. +49(0) 86 41- 69 48 - 60 | www.x-gloo.com | info@x-gloo.com
3
TECHNICAL DATA
4 m
ca. 13,3 kg
ca. 7,23 m2
ca. 23 m2
ca. 2,0 m
ca. 2,38 m
ca. 25 cm
4 m
ca. 13,3 kg
ca. 11,3 m2
ca. 35,7 m2
ca. 7,23 m2
ca. 23 m2
ca. 31 cm
5 m
ca. 2,0 m
ca. 2,38 m
ca. 2,5 m
ca. 3 m
ca. 25 cm
ca. 18,8 kg
4 m
ca. 3,0 m
ca. 13,3 kg
ca. 22,5 kg
ca. 16,27 m2
ca. 11,3 m2
ca. 35,7 m2
ca. 51,34 m2
ca. 7,23 m2
ca. 23 m2
ca. 31 cm
ca. 3,57 m
6 m
5 m
ca. 2,0 m
ca. 2,38 m
ca. 2,5 m
ca. 3 m
ca. 25 cm
ca. 37 cm
ca. 18,8 kg
4x4
Exterior side length ....... ca. 4 m
ca. 25 cm
ca. 13,3 kg
ca. 23 m2
Entrance height .......... ca. 2,0 m
Total height ...............ca. 2,3 m
Covered area
without Side Walls........... 7,23 m
with 4 Canopies ............ca. 23 m
6x6
ca. 22,5 kg
Exterior side length ....... ca. 6 m
Entrance height .......... ca. 3,0 m
ca. 51,34 m2
ca. 37 cm
ca. 16,27 m2
Total height .............ca. 3,57 m
Covered area
without Side Walls......... 16,27 m
with 4 Canopies ....... ca. 51,34 m
5x5
ca. 7,23 m2
Tube diameter ............ca. 25 cm
Weight without Walls ca. 13,3 kg
Setup ........
Hand Pump .....................15 min
2
Electric Pump .................3-5 min
2
Operating pressure
Tube diameter ............ca. 37 cm
Weight without Walls . ca. 22,5 kg
Setup ........
Hand Pump .....................30 min
2
Electric Pump ............. 10-15 min
2
Operating
pressure ........
*This data serves primarily as information, since the operation of the Overpressure Valves is automatic.
4 m
ca. 2,38 m
ca. 2,0 m
ca. 3,0 m
6 m
*
0,18 bar/2,6 PSI
*
0,2 bar/3 PSI
ca. 3,57 m
ca. 31 cm
ca. 18,8 kg
ca. 35,7 m2
Exterior side length ....... ca. 5 m
Entrance height .......... ca. 2,5 m
Total height ..................ca. 3 m
Covered area
without Side Walls...... ca. 11,3 m
with 4 Canopies ......... ca. 35,7 m
8x8
ca. 43 cm
ca. 42 kg
Exterior side length .. ca. 7,85 m
Entrance height ........ ca. 3,94 m
Total height ...............ca. 4,8 m
Covered area ...........ca. 30,3 m
Tube diameter ............ca. 43 cm
ca. 11,3 m2
2
2
2
ca. 3 m
ca. 2,5 m
5 m
Tube diameter ............ca. 31 cm
Weight without Walls ca. 18,8 kg
Setup ........
Hand Pump .....................23 min
Electric Pump ............... 7-10 min
Operating pressure
ca. 30,3 m2
*
0,2 bar/3 PSI
ca. 7,85 m
ca. 3,94 m
Weight without Walls .. ca. 42 kg
Setup with Electric Pump .. 25 min
Operating
*
pressure
............ 0,35 bar/5 PSI
ca. 4,8 m
4
Skywalk GmbH & Co. KG - Windeckstraße 4 - 83250 MARQUARTSTEIN | GERMANY
STANDARD DELIVERY
X-GLOO MATRIX WITH ACCESSORIES
4x4, 5x5 AND 6x6 MODELS
1x - X-Gloo Multifunction Transport Bag (1) 1x - Hand Pump (2) 1x - Side Wall Bag (3) 1x - Anchoring Line Set (4) 1x - Manual and Quick User Guide (5) 1x - Closing Rod for X-Gloo 5x5/6x6 (6) 1x - X-Gloo Repair Kit (contents below)
X-GLOO MATRIX WITH ACCESSORIES
8x8 MODEL
1x - Quick Pack Sack (7) 1x - Hand Pump (2) 3x - Side Wall Bag (3) 1x - Anchoring Webbing Set (8) 1x - Manual and
Quick User Guide (5) 1x - Closing Rod (6) 1x - Setup Support Bar (9) 1x - X-GLOO Repair Kit
(contents below)
7
1
2
5
3
4
6
9
8
X-GLOO REPAIR KIT
1x - Replacement Bladder (10) 1x - Replacement Protection Strip (11) 1x - Replacement Overpressure Valve (12) 1x - Adhesive Repair Patches (13) 1x - Fixing Element Tool (14) 1x - Allen Wrench (15)
Tel. +49(0) 86 41- 69 48 - 60 | www.x-gloo.com | info@x-gloo.com
10
14
12
11
13
15
5
SPECIAL INSTRUCTIONS
GRAPHICS/DESIGN
• A transparent effect can occur (especially with background light) with different tent color combinations (e.g. light Roof color and dark Tubes). This should be taken into consideration by customers when designing the X-Gloo. If in doubt, please consult your X-GLOO professional.
• With sewn application on different cloths, there is an area of overlap of ca. 5-10 mm where the cloth is sewn together. This results in a color change in the area of the overlap.
SET-UP
• Do not exceed the specified maximum air pressure.
• The X-Gloo is not intended for long-term outdoor use and should be inspected for wear or damage after every event.
• If small folds form inside the Tubes when inflating, it is helpful with the larger tents to gently shake the Tube during the inflation process. This will help keep the inner Bladder in the correct position assuring proper inflation.
• The X-Gloo should be deflated in winds exceeding 60 km/h (The first sign of overload is when the Roof begins to compress). When high wind force is expected (gusts of more than 50-60 km/h for the 4x4, 5x5, or 6x6; and more than 40 km/h for the 8x8) the tent must be secured and anchored.
!
PLEASE NOTE: If Side Walls are completely zipped in to a 6x6 tent, a force of almost 500 kg is the result. For this reason, please pay special attention to the following points:
- According to the ground surface, you may require longer or
additional stabilisation materials.
- Additionally, you must attach Anchoring Lines to all Shoulder
Loops (found on the outside of each Tube)!
- Our smaller Water Ballasts (ideal for use on hard ground
surfaces) may not be sufficient for securing your tent against strong wind gusts. Refer to our Wind Resistance Certificate to determine whether Water Ballast Barrels are required.
- Winds stronger than 60 km/h can lead to structural damage of
the tent and this damage is no longer covered by the warranty.
- If weather conditions deteriorate dramatically, all Overpressure Valves should be opened immediately and the tent deflated. Additionally, the deflated tent should be weighted down.
- In general, the Protective Strips on the bottom of the Tubes are exposed to more wear and tear on rough surfaces due to the movement of the tent from wind.
OPERATION
Keep open fires and heat sources away from the X-Gloo. FIRE PROTECTION CLASSIFICATION:
Description of Norms:
- DIN 4102-B1 (Abb.: B1) Controls testing and requirements on the reaction to fire of building materials. German norm, used in most European countries.
- CPAI 84-95, Section 6 Specification of the American Association of Sailcloth Materials for the assessment of flame­retardant materials used in (event-) tents. Due to the fact that the the X-Gloo is in use worldwide at tradeshows as an innovative event tent, we reserve the right not to certify the tent according to the national norms of each country. The certification according to CPAI 84 fulfills the international requirements for flame resistance in tent products and includes similar test criteria like DIN 4102-B1 or NFP 92501­7M2.
• When the tent is used in sandy terrain, avoid getting sand grains
in the Tubes or in the Pump
• Keep the Valves free of sand and dirt particles and clean them if
necessary, since this can cause faulty operation and pressure loss.
• The tent can be damaged by the penetration of sharp objects
(e.g. knives, tools) in the Tubes causing leakage and loss of pressure. Handle the X-Gloo with appropriate care.
• Avoid extreme variations in temperature (day and night) or
long-term use. This can lead to loss of air pressure, requiring reinflation of the tent.
6
Skywalk GmbH & Co. KG - Windeckstraße 4 - 83250 MARQUARTSTEIN | GERMANY
Procedure in the case of pressure loss:
• FIRST close all Valves TIGHTLY!
• If pressure loss continues, blow out the Overpressure Valves to remove all dust or dirt particles.
• If pressure loss still continues, the quickest solution is to remove the Bladder and replace it, as a damaged Bladder is likely the cause.
- If the damage is visible on the Bladder and the damaged
area is smaller than 1 cm -> Apply the Adhesive Repair Patch included in the Repair Kit.
- If the damaged area cannot be found, spray some soap suds
onto the inflated Bladder surface so that the escaping air bubbles are visible and the damage can be located. Then apply the Adhesive Repair Patch to repair the Bladder.
STORAGE
• Avoid pressure spots (e.g. do not lean on the tent with your knees while folding the tent up).
• Store the X-Gloo in a dry location and at temperatures not exceeding 40° celsius.
• Do not pack or store the X-Gloo when damp or wet, since this can cause the formation of mold spots and discoloration.
• At temperatures lower than 0° celsius, folding can lead to damage of the components. Take special care with the Window Walls in low temperatures and pack them carefully.
• Never store the X-Gloo in an automobile in direct sunlight. The intense heat can cause the Window Walls to stick together irreversibly, or may cause permanent damage to the cloth.
!
Important information for digitally-printed parts! Digital printed elements must be stored in dry condition! CAUTION: If the elements are stored while still damp, the ink from the printed material can bleed and the printing can become permanently damaged! We are unable to accept liability.
MAINTENANCE, CLEANING, REPAIR
All kinds of repairs can be done in our workshop in Marquartstein or in the Service Center in Las Vegas, Nevada. We can also take care of special requests (additional straps, velcro strips, etc.) at our facility.
• Maintenance and repair should be carried out only by X-GLOO or by an authorized Service Center.
• The X-Gloo should be periodically inspected for chafe marks and damage and promptly repaired.
• In order to avoid damage of the material coating, first attempt to remove dirt and stains using a soft, dry brush or microfiber cloth. Only if necessary use a small amount of mild alkaline solution mixed with water. Avoid the use of solvents, washing machines or steam cleaning.
• Re-waterproofing is not possible.
MATERIALS
• Bleaching of the material is possible with extended UV exposure (e.g. at high altitude or extended setup time). White wall material tends to yellow from UV exposure, and is easily stained when contacted with dust and dirt. All of the materials currently implemented in the X-Gloo have been subjected to extensive material testing. It is practically impossible to state when exactly a color change could become visible, since the influencing factors vary strongly. However: All cloths change in color with extensive UV exposure! According to expert knowledge, with proper care the X-Gloo will show only minimal color change after many years of use. The range of use will not be limited.
• The materials used (and therefore, the entire tent) are waterproof.
Tel. +49(0) 86 41- 69 48 - 60 | www.x-gloo.com | info@x-gloo.com
7
SETUP
1. LAY OUT THE MATRIX
Spread the X-Gloo Matrix out in the area intended for setup. Try to make sure that the tube endings of the X-Gloo are positioned approximately where you want them once the tent is inflated. This way you can avoid having to reposition or handle the tent again.
8x8 ONLY: Zip in the Middle Wall
Since the entrance height of an assembled X-Gloo 8x8 is very high, we recommend zipping in the Middle Wall before inflating the tent.
!
PLEASE NOTE: Only the outer side of the Middle Walls are equipped with a Zipper Rain Protector. If you should choose to attach the Middle Wall with the outer side facing inwards (so that a logo printed on the outside is be visible from the inside of the tent for example), the waterproof quality of the tent in the area of the zipper can not be guaranteed.
2. TEST THE VALVES
INFLATION VALVE: The Inflation Valves are air-tight and perma­nently welded to the Bladder inside each Tube. Each Inflation Valve consists of a rubber check valve and a threaded valve cover (1).
1 2
The check valve inside the housing prevents air from escaping. In order to prevent dirt from entering, the valve cover is screwed onto the housing after inflation is complete.
OVERPRESSURE/DEFLATION VALVE: Beside the Inflation
Valve you will find a red Over­pressure Valve (2) which opens automatically as soon as the Bladder is properly pressurized.
To deflate the Tubes, unscrew the housing of each Overpressure Valve by turning it counter­clockwise (3).
The function of each Overpressure Valve should be tested before inflation. To do this, unscrew the housing and make sure that the spring can be pushed in. Tightly close each valve after testing.
!
PLEASE NOTE: Sand and dirt can clog the spring inside the Overpressure Valve so that the function is negatively influenced.
3
!
Inflation with the Hand Pump
The standard Hand Pump included in delivery is equipped with different valve sockets and an air hose. Do not kink or press down on the air hose, to avoid air leakage or damage!
!
PLEASE NOTE: See the notation on the hose connection:
Inflate | Deflate
8
Inflation with the Electric Pump Bravo 0V10* and Bravo 2000*
Screw the hose (included in delivery) to the correct opening on the pump.
PLEASE NOTE: See the notation on the
!
hose connection:
IN = Inflate | OUT = Deflate
Stick the plug into the outlet. Please note that the Bravo 2000 has a booster, which can be turned on with the switch. Please read and folllow the operating instructions included with the Bravo OV10 and Bravo 2000.
*120V and 230V models available.
Inflation with the Bravo Turbo Max for 12V automobile battery
The Bravo Turbo Max can be connected to a 12V automobile battery. To avoid draining your battery, make sure that it is fully charged or that the vehicle is running while operating the pump. Please read and follow the operating instructions included with the Bravo Turbo Max.
Connect the cable clamps to the respective connections of the battery (red = +, black = -) and adjust the pressure control to 3 PSI.
Skywalk GmbH & Co. KG - Windeckstraße 4 - 83250 MARQUARTSTEIN | GERMANY
Loading...