Xetawave XETA2 User Manual

Xeta2m-T
User Manual
September 29, 2015
Table of
Contents
Warranty ............................................................................................................................. 1
FCC Notifications ................................................................................................................. 2
1.1 Performance ....................................................................................................... 4
Specifications ...................................................................................................................... 4
1.2 Environmental ........................................................................................................... 5
1.3 Security & Certifications ........................................................................................... 5
1.4 Mechanical / Physical Design .................................................................................... 6
i
Warranty
XetaWave LLC warrants your XetaWave wireless data transceiver against defects in materials and manufacturing for a period of two years from the date of purchase. In the event of a product failure due to materials or workmanship, XetaWave will, at its discretion, repair or replace the product.
In no event will XetaWave LLC, its suppliers or its licensors, be liable for any damages arising from the use of or the inability to use this product. This includes business interruption, loss of business information, or other loss which may arise from the use of this product. XetaWave LLC transceivers should not be used in situations where failure to transmit or receive data could result in damage of any kind to the user or any other party, including but not limited to personal injury, death, or loss of property. XetaWave LLC accepts no responsibility for damages of any kind resulting from delays or errors in data transmitted or received using the XetaWave transceiver, or for the failure of such transceiver to transmit or receive such data.
Warranty policy may not apply:
1) If product repair, adjustments, or parts replacements is required due to
accident, neglect or unusual physical, electrical or electromagnetic stress.
2) If product is used outside of XetaWave specifications.
3) If product has been modified, repaired or altered by Customer unless XetaWave
specifically authorized such alterations in each instance in writing.
The warranty period begins from the date of shipment and is defined per the standard warranty policy stated above.
Information in this document is subject to change without notice. The information contained in this document is proprietary and confidential to XetaWave LLC. This manual is for use by purchasers and other authorized users of the XetaWave wireless data transceiver only.
No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, or for any purpose without the express written permission of XetaWave LLC.
This product is licensed by the United States. Diversion contrary to U.S. law is prohibited. Shipment or re-export of this product outside of the United States may require authorization by the U.S. Bureau of Export Administration. Please contact XetaWave LLC for assistance and further information.
1
FCC
Notifications
Federal Communications Commission
This device complies with Title 47 CFR § Parts 1, 15, 90 of the federal code. Specifically, 47CFR § 1.1310, Table 1, Limits for General Population/Uncontrolled Exposure.
This device must be operated as supplied by XetaWave LLC. Any changes or modifications made to the device without the express written approval of XetaWave LLC may void the user’s authority to operate the device, pose violations and liabilities.
Caution
The Xeta2m-T has a nominal (rated) transmitter output power of:
- All modulations and bandwidths in the 217-220MHz bands: 2 Watts
- MSK, 15kHz, 220-222MHz: 3 Watts
- MSK, 50kHz, 220-222MHz: 2 Watts
- All other modulations and bandwidths, 220-222MHZ: 5 Watts
The transmit antenna shall be kept at least 61.65cm from physical space where humans may exist.
Additional details may be found in the “RF Exposure Calculations” at the end of this
section.
Integration FCC ID:
When the module is installed inside of another device, then the outside of the device into which the module is installed must display a label referring to the enclosed module.
The exterior label will use the wording: ‘Contains FCC ID: XETA2’
Serial # X00000000 1234 1234 Model # XETA2-E Contains FCC ID: PEJ-XETA2 Input Voltage: 12 VDC
This device compiles with Part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference, (2) this device must accept any interference received, Including interference that may cause undesired operation. Made in the USA by Xetawave, LLC Louisville, CO 80027 (303) 447-2745 www.xetawave.com
2
WARNING
These radio systems shall be installed by a RF/radio professional familiar with the applicable rules. Installation of all antennas shall be performed in a manner that will provide at least the MPE Distance from the direction of maximum radiation, to any user or member of the public and consistent with the settings in the applicable antenna installation compliance section below.
FCC antenna compliance
Since professional installation is required, standard RF connectors are used. Adapters or custom coaxial cables may be required to connect the radio output connector to the desired antenna.
Any antenna from a reputable manufacturer with desired bandwidth, gain/pattern coverage, and have an input impedance of approximately 50 ohms can be used.
Exposure Compliance
FCC ID: PEJ-XETA2
It is the responsibility of the licensee or user to guarantee compliance with the appropriate MPE regulations when operating this device in a way other than described herein. The installer of this equipment must ensure the antenna is located or oriented such that it does not emit an RF field in excess guidelines as posted in the 47 CFR Bulletin 65/47CFR § 1.1310 of the Federal Communications Commission.
The XetaWave XETA2 uses a low power radio frequency transmitter. The concentrated energy from an antenna may also pose a health hazard in the near field. People should not be near the antenna when the radio link is operating as general practice and maintain a safe distance as calculated below.
The following calculations are based off the Maximum Permissible Exposure requirements as outlined by the FCC.
The MPED (Maximum Permissible Exposure Distance) is calculated based on the limits for a General Population/Uncontrolled Exposure in the 30 -300 MHz frequency band using the stated MPE power density limit of 0.2 mW/cm2. The following table provides safe distance for several power levels and antennas besides the worst case for convenience.
3
 
2
/(4
)(
cmmWmtExposureLi
nAntennaGaiDutyCyclemWowerConductedP
MPED
Table of MPE Safe Distance vs. Antenna Gain and Power Output Setting
Power Out
Setting
(mW)*
Duty
Cycle
(linear)
Antenna
Gain (dBi)
Antenna
Gain
(linear)
FCC MPE
Limit
(mW/cm2)
Safe
Distance
(cm)
5890
1.00
2.1
1.622
0.2
61.65
*The worst case is 5890 mW with a 2.1dBi gain antenna at 61.65cm
Specifications
To calculate safe distance:
Equation 2:
Where: MPED is Maximum Permissible Exposure Distance or safe distance.
All quantities are calculated in linear or numeric quantities.
The exposure limit, MPED, and conducted power units must be consistent, mW and cm for this case.
Duty cycle is set using packet sizes for master and slave. Packet sizes are set in the radio Network Configuration Menu. At Power up and with no data transmitting, the radios will transmit or beacon with a duty cycle of 6 to 10% depending upon modulation setting. The maximum Duty Cycle is 100%.
1.1 Performance
Transmitter
Frequency Range: 217-222 MHz Output Power: 2W, all 217-220 MHz modulations 3W, MSK, 15 KHz, 220-222 MHz 2W, MSK, 50 KHz, 220-222 MHz 5W, all 220-222 MHz modulations except MSK Range (Line of Sight): 70+ miles Modulation: MSK, QPSK, 8PSK, 16PSK, 32PSK RF Data Rate: 8.75 kbps to 180 kbps Occupied Bandwidth: 9.2 kHz to 45 kHz
4
Frequency Stability: Better than 1.0 ppm Duty Cycle: Continuous Output Impedance: 50 Ohms
Receiver **ALL SENSITIVITIES ARE TBD**
12.5 kHz 25 kHz 50 kHz
217-220MHz MSK 9.6 kbps 18 kbps 43 kbps QPSK 17 kbps 29 kbps 72 kbps 8PSK 26 kbps 44 kbps 105 kbps 16PSK 36 kbps 59 kbps 144 kbps 32PSK 45 kbps 76 kbps 180 kbps
15 kHz 50 kHz
220-222 MHz MSK 8.75 kbps 36 kbps QPSK 19 kbps 59 kbps 8PSK 28 kbps 88 kbps 16PSK 37 kbps 117 kbps 32PSK 47 kbps 146 kbps
Data Transmission
Error Detection: Up to 32-bit CRC, X2 ECC, Retransmit on error
Power / Physical
Operating Voltage: 12 VDC Transmit Current: 1A @ 12V for 1W
1.2 Environmental
-30°C to +50°C operating temperature range.
95% operating humidity @ 40°C non-condensing.
1.3 Security & Certifications
FCC, UL Class 1 Div 2
5
1.4 Mechanical / Physical Design
1.5 Configuration
The following parameters are available for selection by the installer at the end-product level for all products that incorporate the Xeta2m-T:
- Frequency (Master and Slave)
- Modulation Type
The installer shall set the frequency (or pair of frequencies) according to the
requirements of the user’s license. There are different modulations and bandwidths
available. The available modulations are limited to those listed in paragraph 1.1, and
6
further limited by frequency selection. A modulation shall be selected according to the
bandwidth (channel size and number of channels) that is specified in the user’s license.
Lower speeds have generally better sensitivity and longer range, while higher speeds offer greater data throughput.
1.6 Password
The installer shall set a password for the end-product to prevent alteration of the radio parameters by unauthorized parties. The procedure for setting the password is described in the user manual for the end-product that incorporates the Xeta2m-T.
7
Loading...