Xerox Fiery SI Administrator Guide

Fiery SI Color Server
ADMINISTRATOR GUIDE
Copyright © 1996 Electronics for Imaging, Inc. All rights reserved.
This publication is protected by copyright, and all rights are reserved. No part of it may be reproduced or transmitted in any form or by any means for any purpose without express prior written consent from Electronics for Imaging, Inc., except as expressly permitted herein. I nformation in this document is subject to change without notice and does not represent a commitment on the part of Electronics for Imaging, Inc.
The software described in this publication is furnished under license and may only be used or copied in accordance with the terms of such license.
Trademarks
EFI, the EFI logo, Fiery, the Fiery logo, EFICOLOR and the EFICOLOR logo are trademarks registered with the U.S. Patent and Trademark Office. Fiery SI, Fiery XJe, Fiery XJ+, Fiery Driven, the Fiery Driven logo, XJ RipChips, Rip-While-Print, Continuous Print, Command WorkStation, AutoCal, Starr Compression, and Memory Multiplier are trademarks of Electronics for Imaging, Inc.
Adobe, the Adobe logo, Adobe Illustrator , P ostScript, Adobe P hotoshop, Adobe S eparator , and A dobe P ageMaker ar e trademarks of Adobe Systems I ncorporated, registered in certain jurisdictions. EPS (Encapsulated PostScript) is a trademark of Altsys Corporation. Apple, the A pple logo, A ppleShar e, A ppleTalk, E therTalk, LaserWriter, and Macintosh are registered trademarks, and MultiFinder is a trademark of Apple Computer, Inc. Microsoft, MS, and MS-DOS are registered trademarks, and Windows is a trademark of Microsoft Corporation in the US and other countries. QuarkXPress is a registered trademark of Quark, Inc. Times, Helvetica, and Palatino are trademarks of Linotype AG and/or its subsidiaries. ITC Avant Garde, ITC Bookman, ITC Zapf Chancery, and ITC Zapf Dingbats are registered trademarks of International Typeface Corporation. Ethernet is a registered trademark of Xerox Corporation. Farallon, PhoneNET PC, and PhoneNET Talk are trademarks of Farallon Computing, Inc. COPS and COPSTalk are trademarks of CoOperative Printing Solutions, Inc. NetWare and Novell are registered trademarks and Internetwork Packet Exchange (IPX) is a trademark of Novell, Inc. UNIX is a registered trademark of UNIX System Laboratories, a wholly owned subsidiary of Novell, Inc. Sun, Sun Microsystems and SunOS are trademarks or registered trademarks of Sun Microsystems, Inc. PANTONE is a registered trademark of Pantone, Inc. X-Rite
All other terms and product names may be trademarks or registered trademarks of their respective owners, and are hereby acknowledged.
Legal Notices APPLE COMPUTER, INC. (“APPLE”) MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION THE
IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, REGARDING THE APPLE SOFTWARE. APPLE DOES NOT WARRANT, GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OR THE RESULTS OF THE USE OF THE APPLE SOFTWARE IN TERMS OF ITS CORRECTNESS, ACCURA CY, RELIABILITY, CURRENTNESS, OR OTHERWISE. THE ENTIRE RISK AS TO THE RESULTS AND PERFORMANCE OF THE APPLE SOFTWARE IS ASSUMED BY YOU. THE EXCLUSION OF IMPLIED WARRANTIES IS NOT PERMITTED BY SOME STATES. THE ABOVE EXCLUSION MAY NOT APPLY TO YOU.
IN NO EVENT WILL APPLE, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE TO YOU FOR ANY CONSEQUENTIAL, INCIDENTAL OR INDIRECT DAMA GES (INCLUDING DAMA GES FOR LOSS OF BUSINESS PR OFITS, BUSINESS INTERRUPTION, L OSS OF BUSINESS INFORMATION, AND THE LIKE) ARISING OUT OF THE USE OR INABILITY TO USE THE APPLE SOFTWARE EVEN IF APPLE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. BECAUSE SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU.
Apple’s liability to you for actual damages from any cause whatsoever, and regardless of the form of the action (whether in contract, tort [including negligence], product liability or otherwise), will be limited to $50.
Restricted Rights Legends
For defense agencies: Restricted Rights Legend. Use, reproduction, or disclosure is subject to restrictions set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at 252.227.7013.
For civilian agencies: Restricted Rights Legend. Use, reproduction, or disclosure is subject to restrictions set forth in subparagraph (a) through (d) of the commercial Computer Software Restricted Rights clause at 52.227-19 and the limitations set forth in Electronics for Imaging, Inc.’s standard commercial agreement for this software. Unpublished rights reserved under the copyright laws of the United States.
Printed in the United States of America on recycled paper. Part Number:
10012198
®
is a registered trademark of X-Rite, Incorporated.
FCC Information
WARNING: FCC Regulations state that any unauthorized changes or modifications to this equipment not expressly approved by the manufacturer could void the user’s authority to operate this equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, and uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his own expense.
Industry Canada Class A Notice
This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled, “Digital Apparatus” ICES-003 from Industry Canada.
Avis de Conformation Classe A d l’Industrie Canada
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Classe A prescrites dans la norme sur le matériel brouilleur, “Appareils Numériques” NMB-003 édictée par l’Industrie Canada.
Certificate by Manufacturer/Importer
This is to certify that the FC07 is shielded against radio interference in accordance with the provisions of VFG 243/1991. The German Postal Services have been advised that this device is being put on the market and that they have been given the right to inspect the series for compliance with the regulations. Electronics for Imaging, Inc.
Bescheinigung des Herstellers/Importeurs
Heirmit wird bescheinigt, daß der FC07 im Übereinstimmung mit den Bestimmungen der VFG 243/1991 Funk-Entstort ist. Der D eutschen Bundespost wur de das Inverkehrbringen dieses Gerätes angezeigt und die Berechtigung zur Überprüfung der Serie auf Einhaltung der Bestimmungen eingeraumt. Electronics for Imaging, Inc.
RFI Compliance Notice
This equipment has been tested concerning compliance with the relevant RFI protection requirements both individually and on system level (to simulate normal operation conditions). However, it is possible that these RFI Requirements are not met under certain unfavorable conditions in other installations. It is the user who is responsible for compliance of his particular installation.
Dieses Gerät wurde sowohl einzeln als auch in einer Anlage, die einen normalen Anwendungsfall nachbildet, auf die Einhaltung der Funkentstörbestimmungen geprüft. Es ist jedoch möglich, daß die Funkenstörbestimmungen unter ungünstigen Umständen bei anderen Gerätekombinationen nicht eingehalten werden. Für die Einhaltung der Funkentstörbestimmungen einer gesamten Anlage, in der dieses Gerät betrieben wird, ist der Betreiber verantwortlich.
Compliance with applicable regulations depends on the use of shielded cables. It is the user who is responsible for procuring the appropriate cables. Die Einhaltung betreffender Bestimmungen hängt davon ab, daß geschirmte Ausführungen benützt werden. Für die Beschaffung richtiger Ausführungen ist der
Betreiber verantwortlich.
Software License Agreement
Electronics for Imaging, Inc. grants to you a non-exclusive, non-transferable license to use the software and accompanying documentation (“Software”) included with the Fiery XJ Color Server you have purchased, including without limitation the PostScript
®
software provided by Adobe Systems Incorporated.
You may: a. use the Software solely for your own customary business purposes and solely with Fiery XJ; b. use the digitally-encoded machine-readable outline and bitmap programs (“Font P rograms”) pr ovided with F iery XJ in a special encrypted format (“Coded Font
Programs”) to reproduce and display designs, styles, w eights, and versions of letters, numerals, characters and symbols (“Typefaces”) solely for your own customary business purposes on the screen of the Fiery XJ or Macintosh monitor used with Fiery XJ;
c. use the trademarks used by Electronics for Imaging to identify the Coded Font Programs and Typefaces reproduced therefrom (“Trademarks”); and
d. assign your rights under this Agreement to a transferee of all of your right, title and interest in and to Fiery XJ provided the transferee agr ees to be bound by all of the terms and conditions of this Agreement.
You may not: a. make use of the Software, directly or indirectly, to print bitmap images with print resolutions of 6c00 dots per inch or greater, or to generate fonts or typefaces
for use other than with Fiery XJ; b. make or have made, or permit to be made, any copies of the Software, Coded Font Programs, accompanying documentation or portions thereof, except as
necessary for use with the Fiery XJ unit purchased by you; provided, however, that under no circumstances may you make or have made, or permit to be made, any copies of that certain portion of the Software which has been included on the Fiery XJ hard disk drive. You may not copy the documentation;
c. attempt to alter, disassemble, decrypt or reverse engineer the Software, Coded Font Programs or accompanying documentation. d. rent or lease the Software.
Proprietary Rights
You acknowledge that the Software, Coded Font Programs, Typefaces, Trademarks and accompanying documentation are proprietary to Electronics for Imaging and its suppliers and that title and other intellectual property rights therein remain with Electronics for Imaging and its suppliers. Except as stated above, this Agreement does not grant you any right to patents, copyrights, trade secrets, trademarks (whether registered or unregistered), or any other rights, franchises or licenses in respect of the Software, Coded Font Programs, Typefaces, Trademarks or accompanying documentation. You may not adapt or use any trademark or trade name which is likely to be similar to or confusing with that of Electronics for Imaging or any of its suppliers or take any other action which impairs or reduces the trademark rights of Electronics for Imaging or its suppliers. The trademarks may only be used to identify printed output produced b y the Coded Font P rograms. At the reasonable request of Electronics for Imaging, you must supply samples of any Typeface identified with a trademark.
The MacApp software is proprietary to Apple Computer, Inc. and is licensed to Electronics for Imaging, Inc. for distribution only for use in combination with Fiery SI software utilities.
Confidentiality
You agr ee to hold the Software and Coded F ont P rograms in confidence, disclosing the Software and Coded F ont P rograms only to authorized users having a need to use the Software and Coded Font Programs as permitted by this Agreement and to take all reasonable precautions to prevent disclosure to other parties.
Remedies
Unauthorized use, copying or disclosure of the Software, Coded F ont Programs, Typefaces, Trademarks or accompanying documentation will result in automatic termination of this license and will make available to Electronics for Imaging other legal remedies.
Limited Warranty And Disclaimer
Electronics for Imaging warrants that, for a period of ninety (90) days from the date of delivery to you, the Software under normal use will perform without significant errors that make it unusable. Electronics for Imaging’s entire liability and your exclusive remedy under this warranty (which is subject to you returning Fiery SI to Electronics for Imaging or an authorized dealer) will be, at Electronics for Imaging’s option, to use reasonable commercial efforts to attempt to correct or work around errors, to replace the Software with functionally equivalent software, or to refund the purchase price and terminate this Agreement. Some states do not allow limitations on duration of implied warranty, so the above limitation may not apply to you.
Except for the above express limited warranty, Electronics for Imaging makes and you receive no warranties or conditions on the Products, express, implied, or statutory, and Electronics for Imaging specifically disclaims any implied warranty or condition of merchantability or fitness for a particular purpose.
For warranty service, please contact your authorized service/support center. EXCEPT FOR THE ABOVE EXPRESS LIMITED WARRANTY, ELECTRONICS FOR IMAGING MAKES AND YOU RECEIVE NO WARRANTIES
OR CONDITIONS ON THE SOFTWARE OR CODED FONT PROGRAMS, EXPRESS, IMPLIED, STATUTORY, OR IN ANY OTHER PR O VISION OF THIS AGREEMENT OR COMMUNICATION WITH YOU, AND ELECTRONICS FOR IMAGING SPECIFICALL Y DISCLAIMS ANY IMPLIED WARRANTY OR CONDITION OF MER CHANT ABILITY OR FITNESS FOR A P AR TICULAR PURPOSE. Electronics for Imaging does not warrant that the operation of the software will be uninterrupted or error free or that the Software will meet your specific requirements.
Limitation Of Liability
IN NO EVENT WILL ELECTRONICS FOR IMAGING OR ITS SUPPLIERS BE LIABLE FOR ANY DAMA GES, INCLUDING LOSS OF DATA, LOST PROFITS, COST OF COVER OR O THER SPECIAL, INCIDENT AL, CONSEQ UENTIAL OR INDIRECT DAMAGES ARISING FR OM THE USE OF THE SOFTWARE, CODED FONT PROGRAMS OR ACCOMPANYING DOCUMENTATION, HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY. THIS LIMITATION WILL APPLY EVEN IF ELECTRONICS FOR IMAGING OR ANY AUTHORIZED DEALER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. YOU ACKNOWLEDGE THAT THE PRICE OF FIERY SI REFLECTS THIS ALLOCATION OF RISK. BECAUSE SOME STATES/JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES, THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
Export Controls
You agr ee that you will not export or re-export the Softwar e or Coded Font Programs in any form without the appropriate United States and foreign government licenses. Your failure to comply with this provision is a material breach of this Agreement.
Government Use
Use, duplication or disclosure of the Software by the United States Government is subject to restrictions as set forth in subdivision (c) (1) (ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 or in subparagraphs (c) (1) and (2) of the Commercial Computer Software—Restricted Right Clause at 48 CFR 52.227-19, as applicable.
Third Party Beneficiary
You ar e hereby notified that A dobe Systems I ncorporated, a California corporation located at 303 Almaden Blvd., S an J ose, California 95110 (“Adobe”) is a third­party beneficiary to this Agreement to the extent that this Agreement contains provisions which relate to your use of the Fonts, the Coded Font Programs, the Typefaces and the Trademarks licensed her eby. Such provisions are made expressly for the benefit of Adobe and are enforceable by Adobe in addition to Electronics for Imaging.
General
This Agreement will be governed by the laws of the State of California. This Agreement is the entire agreement held between us and supersedes any other communications or advertising with respect to the Software, Coded Font
Programs and accompanying documentation. If any provision of this Agreement is held invalid, the remainder of this Agreement shall continue in full force and effect.
If you have any questions concerning this Agreement, please write to Electronics for Imaging, Inc., Attn: Licensing Dept. or see Electr onics for Imaging ’s web site at www.efi.com.
Electronics for Imaging, Inc. 2855 Campus Drive San Mateo, CA 94403

Contents

Introduction
About the documentation
About this manual xii Conventions used in Fiery SI manuals xii
Chapter 1: Connecting to the Network
Fiery SI on the network Stages of installation on the network Quick path to installation Before you begin Ethernet cable connection Parallel cable connection
Chapter 2: Setting up the Fiery SI
Fiery SI Setup Fiery SI Setup from the Control Panel
Accessing Setup options 2-2
Running Fiery SI Setup
Types of setup screens 2-5
xi
1-1 1-2
1-4 1-11 1-11 1-13
2-1
2-2
2-5
Server Setup options Network Setup options
Ethernet Setup options 2-11 Token Ring Setup options 2-19 Parallel Port Setup options 2-20
Fiery SI printing connections
Direct connection 2-21 Queues 2-21
Printer Setup options
2-8 2-10
2-21
2-23
viii Contents
Administrative functions in the Setup menu
Fiery SI Job Log Setup 2-29 Job Log Setup options 2-30 Calibration 2-31 Change Password 2-35 Clear Server 2-36 Exit Setup 2-36
Chapter 3: Setting up network servers
Fiery SI on an IPX network Tips for experts—IPX networks Overview of IPX printing to the Fiery SI Configuring a NetWare server for printing
Setting the NetWare 4.x bindery context 3-6 Setting up a Fiery SI print queue 3-9
Setting up NetWare Windows clients for printing Configuring Windows 95 workstations for remote utilities Fiery SI on a network with Windows NT Tips for experts—Windows NT with TCP/IP Configuring a Windows NT server to support the Fiery SI
Loading the TCP/IP network protocol 3-18 Adding the Fiery SI to the TCP/IP network 3-20 Installing the Fiery SI as a PostScript printer 3-22 Setting up another printer 3-23
2-29
3-1
3-2
3-3
3-4
3-13 3-14 3-17 3-17 3-18
Configuring Windows NT clients Configuring Windows NT workstations for remote utilities Using AppleTalk with Windows NT Fiery SI on a network with UNIX workstations Tips for experts—UNIX workstations
Important note about the remote printer name 3-29 Setting up the Fiery SI on TCP/IP networks 3-30 Printing and managing print jobs 3-31
3-24 3-25 3-27 3-28 3-28
ix Contents
Chapter 4: Administering the Fiery SI
Administrator functions Maintaining optimal server performance Troubleshooting the Fiery SI
Troubleshooting during Setup 4-3 Runtime error messages 4-8
Appendix A: Token Ring Network Option
Fiery SI Token Ring option
Connecting Token Ring hardware A-1
Configuring the NetWare server Setting up IPX-Token Ring on the Color Server Setting up NetWare Windows clients
Index
4-1
4-2
4-3
A-1
A-3 A-3 A-3
xi About the documentation

Introduction

This manual is intended for anyone who is responsible for integrating the Fiery SI Color Server™ into a business environment that includes networked personal comput­ers. After the Fiery SI is set up, as described in this guide and in vidual users will be able print to the color server as a high-performance color PostScript printer.
This manual includes guidelines on the following topics:
• Basic configuration of the Fiery SI to support printing over AppleTalk, TCP/IP, and IPX (Novell) networks
• Setting up a parallel port connection
• Configuring UNIX systems and Novell and Windows NT servers to provide Fiery SI printing services
• Administering network printing
• Using the Fiery SI in mixed network environments
• Setting up a token ring connection
N
:
The network guidelines in this book are not intended to replace the services of
OTE
an experienced network engineer.
Getting Started
, indi-

About the documentation

This guide is part of the set of documentation that includes the following manuals for users and system administrators:
Getting Started
the Fiery SI. It describes installing PostScript printer drivers, printer description files, and other user software provided on the Fiery SI User Software CD or floppy disks. It also explains how to connect each user to the network.
• The
User Guide
Macintosh, Windows, and UNIX workstations. This guide also describes using the utilities and other software provided with the Fiery SI.
• The
Release Notes
available at the time the other manuals were produced.
describes first time installation of software to enable users to print to
describes how to set printing options and print to the Fiery SI from
contain important information about the product that was not
xii Introduction
About this manual
You’ll find the following information in this manual:
• Chapter 1 illustrates the supported network configurations and shows the network connectors on the Fiery SI.
• Chapter 2 describes configuring the Fiery SI from its Control Panel.
• Chapter 3 offers guidelines for setting up Windows network servers and UNIX sys­tems for printing to the Fiery SI.
• Chapter 4 summarizes some administrative features of Fiery SI software that are available for the three major platforms, and offers some troubleshooting hints.
• Appendix A describes the Token Ring option.
Administrator features described in other manuals are summarized on page 4-1.
Conventions used in Fiery SI manuals
Actions you should perform are shown as numbered steps in bold-faced type, followed by a brief explanation if needed. For example:
1. Choose Options in the Print dialog box.
Special options for your printer are available if you have installed the PostScript Level 2 driver and the PPD for your printer.
A special font indicates text you should type or keys you should press. For example:
<Tab>
indicates that you should press the Tab key.
At the NetWare 4.x drive prompt, type:
rconsole
The special font is also used to highlight options that appear in Fiery SI setup menus. For example:
This option appears only if
Enable Parallel Port
is set to
Yes
.
xiii About the documentation
The initial letters of menu options and Control Panel setups are uppercase. Filenames and settings are listed in the special font only if it is hard to distinguish them from sur­rounding text.
Occasionally you will be referred to other Fiery SI manuals, whose titles will be shown in italics. For example, see
Getting Started
.
1-1 Fiery SI on the network
1

Chapter 1: Connecting to the Network

This chapter summarizes the stages in setting up a Fiery SI, and includes diagrams that refer you to other chapters or other manuals for completing your installation. If you check those references, you should be able to find the information you need quickly.
Fiery SI on the network
When the Fiery SI is connected to a network, it behaves as a networked PostScript printer. The built-in Ethernet interface on the Fiery SI supports three network protocols: AppleTalk, the lpd protocol of TCP/IP, and IPX (Novell). These three protocols (rules that enable computers on a network to communicate with each other) are supported on the Macintosh, Windows, and UNIX platforms and can run concurrently on the same Ethernet cable. Workstations that use other protocols can print through a server that uses one of the protocols mentioned, or they can print to the Fiery SI parallel port. A Token Ring option is also available on some systems. The Fiery SI is auto-sensing, and can handle all of these connections simultaneously.
When you add a Fiery SI to a network, it is assumed that a network administrator will have already installed a network cabling system and connected workstations and serv­ers, and perhaps one or more printers.
1-2 Connecting to the Network
1
Physically connecting the Fiery SI to a functioning network
Configuring the network server
Fiery SI Setup

Stages of installation on the network

Installation can be performed by a network or printing administrator. The stages of a successful installation are:
Prepare a network node for the Fiery SI—obtain cable and route it to the location where the Fiery SI will be installed (near the copier), and attach the cable to the net­work interface of the Fiery SI. See page 1-11 for details.
When network servers are required, you need to configure those servers to provide cli­ent access to the Fiery SI as a color PostScript printer. See Chapter 3 for configuring network servers in Windows and UNIX network environments.
Configure the Fiery SI for your particular printing and network environment. See Chapter 2 for details.
Client setup
Install the files needed for printing, install additional user software, and connect the client to the network. These steps are described in tion is provided in Chapter 3 of this manual.
Job administration
You can track and manage print jobs when networked users print to the Fiery SI. See Chapter 4 for details.
Getting Started,
and some informa-
1-3 Fiery SI on the network
1
Summary of Fiery SI network installation
CONNECTION
SERVER CONFIGURATION
COLOR SERVER SETUP
CLIENT SETUP
Fiery SI
Copier
UNIX Macintosh PC
Network server
Prepare a network node. Connect the Fiery SI to the copier and to the network.
Configure UNIX, Windows NT and IPX (Novell) servers to specify Fiery SI print queues and Fiery SI users.
Install Fiery SI remote utilities on the server and make installation disks for client installations.
No special configuration of AppleShare servers is required.
In the Fiery SI Control Panel Setup, choose Server Setup, Network Setup, Printer Setup and Job Log Setup. Set up the Fiery SI for all active protocols.
At each workstation that will print to the Fiery SI:
• Install the PostScript Level 2 printer driver and the Fiery SI PostScript printer description file (PPD), and connect to one or more queues.
• For computers that will use them, install Fiery SI remote utilities and optional user software.
• Verify the Fiery SI in the list of printers and run a test print.
Fiery SI available on the network
1-4 Connecting to the Network
1

Quick path to installation

The diagrams in the following pages show typical systems that can be used for printing and for using the Fiery SI utilities. To use the diagrams, find the page with your preferred platform and network type. Then look up the setup procedures in the pages and books referred to in the keys.
The diagrams describe devices that use the supported networking protocols. They are logical diagrams and are not intended to describe the physical arrangement (topology) of devices on the network. A variety of physical arrangements is possible with each logical arrangement. For example, twisted pair Ethernet networks commonly use a star configuration around a hub, rather than a bus arrangement. The design of physical networks is beyond the scope of this manual.
If the network uses more than one protocol or more than one type of workstation, combine the setups listed for each component of your system. Note that multiple protocols (shown in the diagrams as parallel lines) can run on the same cable. A solid connection from the Fiery SI with an arrow indicates that other supported network types can be operational at the same time.
The protocols used in these diagrams are indicated as follows:
IPX (Novell)
AppleTalk
lpd (TCP/IP)
Parallel
Other
1-5 Fiery SI on the network
1
Networked Macintosh computers using AppleTalk
Key to setup:
1 Macintosh Getting Started 2 Fiery SI Setup Chapter 2
Another supported protocol
Fiery SI connected to copier
2
AppleTalk
AppleTalk protocol
Macintosh
1
Macintosh
1
Macintosh computers can print directly and run all Fiery SI utilities
Macintosh
1
1-6 Connecting to the Network
1
Predominantly Macintosh environment with AppleTalk
Key to setup:
1 Macintosh Getting Started 2 PC with AppleTalk Getting Started 3 Fiery SI Setup Chapter 2
Another supported protocol
Fiery SI connected to copier
3
AppleTalk
AppleTalk protocol
PC compatible
2
Macintosh
1
Macintosh
1
For printing and running Fiery SI utilities with AppleTalk
Macintosh computers PC compatibles with AppleTalk:
• Windows 3.x running PhoneNET PC or COPSTalk
1-7 Fiery SI on the network
1
PC compatibles in a Novell environment
Key to setup:
1 NetWare server page 3-4 2 Fiery SI Setup Chapter 2 3 NetWare client Getting Started 4 Windows 95 with SPX page 3-14,
Getting Started
5 Windows 3.1 with SPX Getting Started
Another supported protocol
Fiery SI connected to copier
2
PC compatible
3
IPX protocol
SPX protocol (TCP/IP or AppleTalk possible)
IPX
PC compatible
3
Novell NetWare server
1
PC compatible
3, 4, 5
IPX
SPX for running utilities
Printing on this network
All PC compatibles can print through the NetWare server
For running Fiery SI utilities
A PC compatible running Windows 3.1 or Windows 95 with IPX/SPX protocols loaded
The functionality outlined here also applies to token ring networks
1-8 Connecting to the Network
1
Windows NT Server environment
Key to setup:
1 Windows NT Server page 3-17 2 Fiery SI Setup Chapter 2 3 Windows NT client page 3-24,
Getting Started
Another supported protocol
Windows NT Workstation
or Windows NT Server acting as print server
1
LAN with NETBEUI, etc.
PC compatible
3
PC compatible
3
NETBEUI or other protocol available on the clients and the server
Windows NT Workstation
or Windows NT Server with
TCP/IP loaded
1
Fiery SI connected to copier
2
lpd (TCP/IP) for printing
TCP/IP for utilities
Printing on this network
PC compatible clients can print using a protocol available on the Windows NT print server; Windows NT machines can print using TCP/IP with lpd
For running Fiery SI utilities
A PC compatible running Windows NT Server or Windows NT Workstation, with TCP/IP loaded
TCP/IP protocol
1-9 Fiery SI on the network
1
UNIX workstations and PC compatibles on a TCP/IP network
Key to setup:
1 UNIX server/host page 3-28 2 Fiery SI Setup Chapter 2 3 UNIX workstation page 3-28 4 TCP/IP client Getting Started,
page 3-28
5 Windows NT page 3-17
UNIX server or workstation
1, 3
Another supported protocol
Fiery SI connected to copier
2
lpd (TCP/IP) protocol
TCP/IP client PC
4
lpd (TCP/IP)
Windows NT computer with
TCP/IP loaded
5
Printing on this network
UNIX workstations with lpd protocol can print directly and act as host for shared printing
TCP/IP clients can print through UNIX server or directly
For running Fiery SI utilities
Requires PC compatible running Windows NT with TCP/IP and lpd loaded.
Remote utilities are not available on UNIX workstations.
1-10 Connecting to the Network
1
Fiery SI parallel port connection
Key to setup:
1 Fiery SI Setup Chapter 2 2 PC compatible User Guide
With the parallel port enabled, the Fiery SI can accept and print jobs sent to its parallel port.
Fiery SI connected to copier
1
A supported network protocol
Parallel input
Protocol not directly supported on Fiery SI
Parallel
PC workstation, server, or laptop
2
The rest of this chapter and the next cover the parts of a installation that are performed on the Fiery SI itself. This chapter describes the physical network connections; Chapter 2 summarizes Fiery SI Setup and other administrative functions available from the Control Panel.
In addition to Ethernet and parallel cabling, described in this chapter, a Token Ring option is available for some Fiery SI models. See Appendix A for more information.
1-11 Ethernet cable connection
1

Before you begin

The following steps should be completed before you configure the Fiery SI and the workstations that will print to the Fiery SI. A service technician will have performed some initial installation.
TO PREPARE FOR FIERY SI INSTALLATION:
1. Make a copier test page to make sure the copier is functioning normally.
2. Shut down the copier and connect the interface cable from the copier to the Fiery SI.
3. onnect the network cable to the Fiery SI, as described in the next section.
An Ethernet network should already be installed and operational.
4. Turn on the copier and the Fiery SI.
5. Prepare network servers to share Fiery SI user software and to enable networked users to print to the Fiery SI, and proceed to Setup.
See Chapters 2 and 3 for details.

Ethernet cable connection

The Fiery SI supports Ethernet cabling of three types:
• Thinnet (thin coaxial Ethernet cable or 10Base 2)
Uses an external transceiver (media attachment unit, or MAU) to attach to the AUI (attachment unit interface) connector on the Ethernet interface of the Fiery SI.
• Thicknet (thick coaxial Ethernet cable or 10Base 5)
Cable connects directly to the AUI connector on the Ethernet interface of the Fiery SI.
• Twisted pair (unshielded twisted pair cable or 10Base-T)
Uses an 8-pin RJ-45 connector that plugs into the RJ-45 socket on the Fiery SI.
The Ethernet connectors lead to the Ethernet network adapter chip built into the main logic board of the Fiery SI.
1-12 Connecting to the Network
1
Back view of the Fiery SI
Centronics-type parallel connector
AUI connector for thinnet and thicknet
RJ-45 connector for twisted pair Ethernet
Serial port for densitometer (for calibration)
Copier connector slot
Slots for options, for example
token ring
SCSI connector for external CD-ROM drive
Shut down the Fiery SI before connecting it to any network device
!!
NOTE: Do not attach the cable to more than one Ethernet connector on the Fiery SI at
one time.
TO USE THINNET CABLE:
1. With the Fiery SI turned off, connect the transceiver to the AUI connector on the back of the Fiery SI. Press down on the latch to lock the transceiver connection.
2. Connect the thinnet cable to the BNC connector on the transceiver.
3. Configure network servers for printing and then proceed to Setup.
Power switch
.
1-13 Parallel cable connection
1
TO USE THICKNET CABLE:
1. With the Fiery SI turned off, connect the thicknet cable connector to the AUI connec­tor on the back of the Fiery SI. Press down on the latch to lock the connector.
2. Configure network servers for printing and then proceed to Setup.
TO USE TWISTED PAIR CABLE:
1. With the Fiery SI turned off, connect the RJ-45 cable connector to the RJ-45 socket on the back of the Fiery SI.
2. Configure network servers for printing and then proceed to Setup.

Parallel cable connection

In addition to receiving print jobs over Ethernet, the Fiery SI can accept print jobs from a PC-compatible computer or server through its high-speed parallel port. This connection is advantageous for portable computers and for workstations that use dedicated networks using protocols other than AppleTalk, TCP/IP, or IPX.
The parallel port connection is active at the same time as the Ethernet port.
TO USE PARALLEL CABLE:
1. With the Fiery SI and a PC-compatible computer or server turned off, attach the Cen­tronics-type parallel cable to the parallel port of the Fiery SI.
The parallel port is the top connector on the back of the Fiery SI.
2. Connect the other end of the cable to the parallel port on the PC.
3. Turn on the computer and the Fiery SI.
4. Proceed to Setup.
To print to the parallel port, you will need to set up the parallel port connection. See “Parallel P ort S etup options ” on page 2-20. For information on setting up printing, see Getting Started; for printing to the parallel port, see the User Guide.
2-1 Fiery SI Setup
2

Chapter 2: Setting up the Fiery SI

The Fiery SI Color Server fits into a variety of work environments. To prepare for printing at your site, you need to do some initial configuration to specify the network environment and the kind of printing you will do.
Fiery SI Setup
Setup is required the first time the Fiery SI is powered on after new system software is loaded. In this first-time setup you (or the service technician who loads the software) choose the language you want to use for Control Panel screens.
For the first-time setup, the server, network, and printer have to be set up from the Control Panel, in that order. Aside from choosing your copier or printer model, default settings are adequate for this setup although they may not be optimal. After you become more familiar with your options you can reset them according to your network and user environment.
On IPX networks and on some TCP/IP networks, the network servers should be configured for printing to the Fiery SI before you enter network settings on the Fiery SI. The diagrams on pages 1-5 through 1-10 give chapter references for network server setup.
You’ll need a live network connection so the Fiery SI can query the network for zones, servers, and server-based queues.
Whenever the configuration of servers, printers, or the network itself changes at your site, you can alter individual settings to correspond to the changed environment. Like­wise, if printing needs or administrative requirements change, you can alter the corre­sponding settings.
NOTE: Changing network or port settings may require that you make changes in more
than one setup area.
2-2 Setting up the Fiery SI
2
Fiery SI Setup from the Control Panel
Setup, performed from the Control Panel right after powering on the Fiery SI, configures it to communicate with other devices and manage print jobs sent to it.
There are four groups of setup options:
Server Setup to specify system options
Network Setup to specify all the active network systems that will transmit print jobs
to the Fiery SI
Printer Setup to specify the way print jobs and queues are managed on the color
server
Job Log Setup to specify how the Fiery SI handles its log of printed jobs
The setup menus also allow you to calibrate the copier or printer , cr eate and change an administrator password, and clear the jobs queued on the server.
Accessing Setup options
The Control Panel on the front of the Fiery SI enables you to set options and view information about jobs printed to the Fiery SI.
It comprises the following parts:
• Display window showing status information and options for setting up the Fiery SI
• Line selection buttons
• Up and down arrow buttons
• Menu button (escape)
• Activity light that indicates normal or problem activity
2-3 Fiery SI Setup
s
2
Fiery SI Control Panel
Activity light
Fiery SI at Idle (ready); message shown in display window
Up and down arrow buttons
Menu button
TO ACCESS SETUP WHEN THE FIERY SI IS AT IDLE:
Server Name
Idle 850 MB 1.0
Server Info
The User Guide describes the online display screens in detail. This chapter describes only the screens you might see when performing setup.
1. When the Fiery SI displays the Idle screen, press the oval Menu button on the Control Panel to go to the Functions menu.
The Functions menu has two screens, as shown to the left.
2. Press the down arrow button to view the second screen of the Functions menu.
3. In the second screen, press the button to choose Reboot Server.
After automatic startup diagnostics, the Fiery SI displays the entry screen.
Line selection button
2-4 Setting up the Fiery SI
For software update or setup, press any key.
Run Setup Install Software Format Disk
Start Up
Exit Setup Server Setup Network Setup Printer Setup
Setup
Job Log Setup Calibration Change Password Clear Server
Setup
2
4. At the startup message, press any button.
5. Choose Run Setup to access all setup menus.
6. Press the line selection button to choose a Setup menu or command.
7. Choose setups in the same order as they appear in the menu: Server Setup, Network
The Start Up screen is displayed.
The Install Software and Format Disk commands are for service technicians.
Press the down arrow to view the second screen of the main Setup menu.
Setup, Printer Setup, and then Job Log Setup.
The sequence is important for first-time setup. Later, just go directly to the menu you want to change. However, if you make
changes in Network Setup, y ou may need to change some settings in P rinter Setup as well.
NOTE: If you make changes in Server, Network, or Printer Setup, you’ll need to
update the system configuration by opening and saving the other setups even if you haven’t changed any other settings.
TO ACCESS SETUP WHEN THE FIERY SI IS OFF:
1. Make sure the Fiery SI is connected to the copier/printer and connected to the network you will use.
2. Turn on the Fiery SI.
The startup diagnostics are performed.
3. At the startup message, press any button.
4. Continue with step 5 from the previous procedure.
Review the settings described in this chapter. F or mor e information on calibration, and on Control Panel screens other than those in the Setup, see the User Guide.
2-5 Fiery SI Setup
2
Running Fiery SI Setup
When you restart the Fiery SI and choose Run Setup, you can select one menu after another and enter information about your Fiery SI and your network and printing environment.
In each setup, the last line of the display window tells you the name of the current Setup menu. The screens you see are shown on the Control Panel Map, a multiple­page flowchart that can be printed from the color server. When the color server is displaying the Idle screen (shown in the figure on page 2-3), you can print the Control Panel Map by choosing Print Pages from the Functions menu, and then choosing Control Panel Map.
Types of setup screens
There are two types of setup options:
Multiple choice questions
You are given choices (for example, Yes or No, or a list of options from which to choose). Only one choice is displayed at a time, in highlighted text. The currently selected (or the default) value appears first.
Information entry options
Use the up and down arrow buttons to scroll through the selections, and choose OK when the correct information is displayed.
You must specify the information for your site. For example, the printer name or IP address.
In that case, use the up and down arrow buttons to scroll the alphabet and numerals to make your selection.
The cursor position is made evident, and two of the line selection buttons become left and right buttons. Arrows appear on the display window next to the corresponding buttons. Use these buttons to move between positions for entering information.
NOTE: When you enter text, enter it from left to right, as
the left-arrow button acts as a delete key as well as a cursor­moving key. This is indicated in the display by the delete symbol ( ).
2-6 Setting up the Fiery SI
2
Example: Multiple choice
Publish Print Queue
Yes
OK
Printer Setup
Press the up or down arrow button to display the other option or options.
Example: Information entry with fields
Subnet Mask
255.0.0.0 >
< OK
TCP/IP Setup
From the starting position, press the right arrow but­ton to move the cursor to the right.
Example: Information entry with individual characters
Publish Print Queue
No
OK
Printer Setup
When the setting you want is displayed, press the but­ton beside OK to continue.
Subnet Mask
255.0.0.0 > < OK
TCP/IP Setup
The next field is selected. Press the up or down arrow button to change the num­ber.
Subnet Mask
255.255.0.0 > < OK
TCP/IP Setup
When the correct number is displayed, press the right arrow button to move to the third field. Press the left arrow to go back and edit, or press OK to accept the choice and continue.
Enter Your File Server Password >
OK
IPX (Novell) Setup
From the starting position, press the up or down arrow button to enter the first character.
x
When the correct charac­ter is displayed, press the right arrow button to move the cursor to the next posi­tion.
Enter Your File Server Password >
9
OK
IPX (Novell) Setup
Enter Your File Server Password >
x
9 OK
IPX (Novell) Setup
Press the up or down arrow to enter a character in the second position. The delete button erases the current character and moves the cursor to the left.
x
Loading...
+ 84 hidden pages