Installation Instructions for FIB1- SERIAL RS-485/RS-423/RS-232 to Fiber Converter
Description
The FIB1-SERIAL will extend RS-485 transmission distance up to 2Km over multimode fiber or up to 120Km over single mode fiber. The converter is equipped with multiple interface circuits, for connection to RS-232, RS-423, or RS-485 (2 or 4-wire). The FIB1-SERIAL secures data transmissions at speeds up to 256kbps for RS-232, or up to 1024kbps for RS-422/485.
Specifications
Optical
Wavelength: 850, 1310 or 1550nm Optical Mode: Single Mode(S/M), or Multimode(M/M) Operating Distance: 2Km over multimode fiber
or up to 120Km over single mode fiber Fiber Type: 50/125um, 60/125um for M/M ; 9/125um for S/M Power Margin: 11dB(2Km, M/M), 12dB ~ 35dB(15 ~ 120Km, S/M) Data Rate: 31.104Mbps Line Coding: Scrambled NRZ Bit Error Rate: Less than 10
-11
DC Jack
DC Jack
Fiber Connections
Fiber Connections
LEDs
LEDs
screws terminal
Pin Definition
Pin Definition
Stickers
Stickers
Front Panel Serial Port Definition & DIP Switch Setting
Front Panel Serial Port Definition & DIP Switch Setting
66--screws terminal
DIP Switch
DIP Switch
Connectors Specifications
Optical: ST/SC type or WDM type (SC) Data: 6-Position detachable screw terminal
DATA SIGNAL Specifications
Data Formats: RS-485/422 2-Wire
RS-485/422 4-Wire
RS-232 + RTS/CTS 5-Wire
RS-232 3-Wire
RS-423 + RTS/CTS 5-Wire
RS-423 3-Wire
TTL 3-Wire Baud Rate: RS-485/422 up to 1024kbps
RS-232/423 up to 256kbps
TTL up to 1024kbps
LED Indicators
LED Indicators
LED
LED
Power Power indicator On Converter has power
Fiber Link Fiber link On The fiber link is up
Test Mode display On Any loopback test is on Data In Mode display On Serial transmission or receiving all zeros
Function
Function
State
State
Off Converter has no power Blinking No SNMP is installed in FRM301
Off No signal or fiber link is down Blinking Remote side fiber Sync loss
Off Normal status
Off No Serial transmission or receiving all Blinking Receiving random serial data
Status
Status
(space) data ones (mark) data
V.: 1.3
Six-screws Terminal Block
Application
FIB1-SERIAL Pin Assignment (DB9 Connector for Option)
Fiber Optic Connectors
Two connectors are provided for fiber optic cable connection. One is for transmission and the other is for reception of optical data. (WDM transceiver has only on SC connector for bi-directional transmissions on a single fiber)
Environment
Temperature : 0-50℃(operating)
-20℃- 70℃ (storage)
Humidity 10-90% non condensing
Dimension
138mm x 86mm x 20mm
(H x W x D)
Power
+12V / 1A maximum DC plug type : center Positive
Weight : 300g
PIN
NO #
1
DB9
Female
9 72
3 4 5 6
TRADEMARKS Ethernet is a registered trademark of Xerox Corp.
®
ST
is a registered trademark of AT&T.
WARNING:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate ra dio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference in which case the user will be required to correct the interferen ce at his own expense. NOTICE: (1) The changes or modifications not expressively approved by the party responsible for compliance could void the user's authority to operate the equipment. (2) Shielded interface cables and AC power cord, if any, must be used in order to comply with the emission limits.
CISPR PUB.22 Class A COMPLIANCE:
This device complies with EMC directive of the European Community and meets or exceeds the following technical standard. EN 55022 - Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment. This device complies with CISPR Class A.
WARNING:
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
CE NOTICE
Marking by the symbol CE indicates compliance of this equipment to the EMC directive of the European Community. Such marking is indicative that this equipment meets or exceeds the following technical standards: EN 55022:1994/A1:1995/A2:1997 Class A and EN61000-3-2:1995, EN61000-3-3:1995 and EN50082-1:1997