Xerox 2300 User Manual

Product Safety Data Sheet XEROX
Product: 2300 PSDS No.: 0607
ISSUE DATE: 6/18/83 REV. DATE: 2/26/90
Section I - Product Identification
Manufacturer's Name Emergency No. EH&S Inquiries
Xerox Corporation (585) 422-2177 (800) 828-6571
Rochester, New York 14644 Product Designation Product Code
2300 930
Section II - Electrical Information
Line Voltage Line Current Freq. Branch Cir. Protection
(Volts) (Amps) (Hertz) (Amps)
115 9 60 15A Sole or Multi-use
(sole use recommended)
Line Cord / Plug Specification Power Consumption (Watts)*
Single Phase 2 Wire + Ground Running: 1,000 NEMA 5-15R / 5-20R Standby: 160
Agency Approvals UL File Number E24014 CSA LR Number LR2196
Section III - Supplies Xerox Part No. Material Safety Data Sheet
Dry Imager (magnetic) 6R130 A-0009A Dry Imager 6R189 A-0009 Developer 5R129 B-0209A Fuser Oil 8R79 D-0407 Photoreceptor 1R19 Article (C2) **
Section IV - Environmental Information
Product Size Heat Emission* Environmental Limitations
(Centimeters/Inches) (BTU/HR) Min Max D: 56 / 22.1 Running: 3,800 Relative Humidity (%)10 85 W: 95 / 37.4 Standby: 607 Ambient Temp. (
o
C) 10 32
H: 33 / 13.0
Floor Space Requirements Weight
(Meters/Feet) (K Grams/Lbs.) 2 x 2 / 6.6 x 6.6 79 / 174
* Based on a five-minute average ** MSDS is not required by OSHA, Hazard Communication Std., 29CFR or WHMIS HPA (Section II (2)
http://www.xerox.com:80/environment.html
PRODUCT: 2300 PSDS No. 0607
Section V - Emission/Exposure Information*
Light Source
Long term viewing of exposure lamp may be uncomfortable but not harmful.
Electromagnetic Emissions
US FCC: Class A Canada DOC: Class A Germany VDE: Class B
Audible Noise TLV
Running: 59.5 dB (A) 85.0 dB (A) Standby: 46.5 dB (A) Impulse: 74.0 dB (A)
Ozone TLV
92 ug/min 0.1 ppm
0.009 ppm (TWA)
0.024 ppm (Peak) Concentration Based on Customer Simulation Model:
Daily Copy Volume 270 copies / 7.84 hours Room Size 5.0 m
3
1/2 Air Room Change per Hour
Dust TLV
0.024 - 0.31 mg/m
Selenium TLV
< 0.035 - 0.05 ug/m
Arsenic PEL
< 0.022 ug/m
3
3
3
10 mg/m
200 ug/m
10 ug/m
3
3
3
Nitrogen Dioxide TLV
< 0.04 ppm 3 ppm
* TLV (Threshold Lim it Value) and PEL (Permiss ible Exposure Level) respectively set by American Conf erence of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for a normal eight hour workday.
07/07/97
All measurements were made on products performing within established operating specifications and received recommended m aintenance procedures. Xer ox certifies that this produc t meets or exceeds the applicable standards for safety and emissions.
http://www.xerox.com:80/environment.html
Loading...