Xerox 212 DP-C, 214 DP-C User Manual

Product Safety Data Sheet XEROX
PRODUCT: XEROX 212 DP/C PSDS No.: 0819
XEROX 214 DP/C ISSUE DATE: 11/18/98
REV. DATE: 1/10/01
Manufacturer's Name Emergency No. EH&S Inquiries
The Document Company, Xerox (585) 422-2177 (800) 828-6571
Manufacturer's Address
1125 John Street West Henrietta, New York 14586
Product Designation Product Identifier
Xerox 212 DP/C XZA-1 Xerox 214 DP/C XZA-1
Section II - Electrical Information
Line Voltage Line Current Freq. Phase Branch Cir. Protection
(Volts) (Amps) (Hertz)
110 - 127 8.0 50/60 15A Single Phase
Line Cord/Plug Specification Power Consumption(Watts)*
Single Cord 15A 3 Conductor 18Awg Running: 300
Standby: 23
Agency Approval
UL & cUL File Number E51242
Section III - Supplies
Xerox Part No. Material Safety Data Sheet
Black Toner, CRU 113R180/118R181 (USCO/ACO/CAN) A-0614 **
113R182 (Xerox Limited) A-0614 ** 113R285 (metered US/ACO/CAN) A-0614 ** 113R286 (metered XL) A-0614 ** 113R287 (retail) A-0614 ** 113R335 (OEM) A-0614 **
Section IV - Environmental Information
Product Size Heat Emission* Environmental Limitations
Configuration (Centimeters/Inches) (BTU/HR)
D: 40.0 / 16.0 Running: 1,023 Relative Humidity (%) 15 85 W: 63.5 / 25.0 Standby: 78 Ambient Temp. (oC) 10 32 H: 32.3 / 13.0
Min Max
*Based on a five-minute average
** MSDS is not required by OSHA, Hazard Communication Std., 29 CFR or WHMIS HPA Section II (2)
PRODUCT: XEROX 212 DP/C PSDS No. 0819
XEROX 214 DP/C
Floor Space Requirements Weight
(Meters/Feet) (K Grams/Lbs.)
2.4 / 7.2 22.6 / 50.0
Section V - Emission/Exposure Information*
Light Sources FDA Accession #
FDA registered Class 1 Laser 9820515-02
Electromagnetic Emissions
US FCC: Class A Canada DOC: Class A
Audible Noise TLV
Run 52.7 dB(A) 85.0 dB(A) Standby 28.5 dB(A) Impulse 62.2 dB(A)
Ozone TLV
159 ug/min
0.011 ppm (TWA) 0.1 ppm
0.015 ppm (Peak) Concentration Based on Customer Simulation Model:
Daily Copy Volume 100 copies/8.0 hours Room Size 6 m
3
1/2 Air Room Change per Hour
Total Dust TLV
0.003 mg/m3 10 mg/m
3
Organics Silicon Oil
<10 ppb 0.0 mg/m
3
* TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American
Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time Weighted Average) for normal, eight-hour workday.
06/15/99
All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions.
Loading...