Product Safety Data Sheet XEROX
Xerox Corporation (585) 422-2177 (800) 828-6571 Manufacturer's Address
Rochester, N.Y.
Product Designation Product Identifier: DocuColor 2006 YCA-1 for IOT YCA-3 for Scanner
Section II - Electrical Information
Line Voltage Line Current Freq. Branch Cir. Protection (Volts) (Amps) (Hertz) (Amps)
100-127 10 50/60 15
Line Cord/Plug Specification Power Consumption(Watts)*
Equipped with Appliance coupler Detachable Cord, Two wire + Ground Running: 451 NEMA 5-15P/ -20P Standby: 234
Agency Approval
UL File Number E158002 cUL File Number E158002
Section III - Supplies Xerox Part No. Material Safety Data Sheet
CRU TONER, Cyan 6R995 Article ** (A30) CRU TONER, Magenta 6R996 Article ** (A30) CRU TONER, Yellow 6R997 Article ** (A30) Print Cartridge 13R574 Article **
CRU Toner, Black 6R994 Article ** (A30)
Section IV - Environmental Information Product Size Heat Emission* Environmental Limitations
(Centimeters / Inches) (BTU/HR) Min Max
D: 750 / 21.9 Running: 1533 Relative Humidity (%) 15 85
W: 650 / 27.0 Standby: 796 Ambient Temp. (oC) 5 32 H: 1160 / 16.2 Floor Space Requirements Weight (Meters / Feet) (K Grams / Lbs.) W = 2.2 / 7.3 IOT 86.5 / 208 D = 1.7 / 5.7
* Based on a five minute average ** MSDS is not required by OSHA, Hazard Communication Std., 29 CFR or WHMIS HPA (Section II (2) )
Product: DocuColor 2006CP PSDS No: 0861 Section V - Emission/Exposure Information*
Light Source FDA Accession #
FDA registered laser in a Class 1 Laser System 9820515-03
Electromagnetic Emissions
US FCC: Class A, Token Ring Class A Canada DOC: Class A, Token Ring Class A
Audible Noise TLV
Run 52.9 dB(A) 85.0 dB(A) Standby 35.7 dB(A) Impulse 66.7 dB(A)
Ozone
Concentration Based on Simulation Model: Daily Copy Volume 136 copies/ hours Room Size 8 m3 1/2 Air Room Change per Hour
0.01 mg/m3 TLV
0.005 ppm 0.1 ppm
Total Dust TLV
.012 mg/m3 10 mg/m
3
* TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American
Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time­Weighted Average) for a normal eight-hour workday.
All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions.