Xerox 16P, 16FX User Manual

Product Safety Data Sheet XEROX
Product: WorkCentre Pro 16fx PSDS No.: 0832
WorkCentre Pro 16p ISSUE DATE: 01/28/00
REV. DATE: 1/10/01
Manufacturer's Name Emergency No. EH&S Inquiries
Xerox Corporation (585) 422-2177 (800) 828-6571
Manufacturer's Address
Rochester, N.Y.
Product Designation Product Identifier:
WorkCentre Pro 16fx LY9 WorkCentre Pro 16p LY8
Section II - Electrical Information
Line Voltage Line Current Freq. Branch Cir. Protection
(Volts) (Amps) (Hertz) (Amps)
120 9.5 60 20
Line Cord/Plug Specification Power Consumption(Watts)*
Equipped with Appliance coupler Detachable Cord, Two wire + Ground Running: 295 NEMA 5-15P/ -20P Standby: 19
Agency Approval UL File Number E145607 cUL File Number E145607
Section III - Supplies
Xerox Part No. Material Safety Data Sheet CPU TONER 6R972, 6R987, 6R988 Article ** (A19) CPU DRUM 13R563 Article ** (C40)
Section IV - Environmental Information
Product Size Heat Emission* Environmental Limitations
(Centimeters / Inches) (BTU/HR) Min Max
D: 55.6 / 21.9 Running: 1,003 Relative Humidity (%) 20 85 W: 69.9 / 27.0 Standby: 65 Ambient Temp. (oC) 10 35 H: 41.1 / 16.2 Power Saver: 58
Pwr Svr: 17
Floor Space Requirements Weight
(Meters / Feet) (K Grams / Lbs.)
N/A - Desktop unit IOT 21 / 46
* Based on a five minute average ** MSDS is not required by OSHA, Hazard Communication Std., 29 CFR or WHMIS HPA (Section II (2) )
Product: WorkCentre Pro 16fx PSDS No: 0832
WorkCentre Pro 16p
Section V - Emission/Exposure Information*
Light Source FDA Accession #
Class 3b Laser in a Class 1 Laser System, 9831195 registered with US FDA. Copy lamp is rare gas Fluorescent.
Electromagnetic Emissions
US FCC: Class B Canada DOC: Class B
Audible Noise TLV
Run 46.9 dB(A) 85.0 dB(A) Standby 24.9 dB(A) Impulse 55.7 dB(A)
Ozone
Concentration Based on Simulation Model: Daily Copy Volume 136 copies/ hours Room Size 8 m
3
1/2 Air Room Change per Hour Ozone Filter – Life of Product
Emissions rate: 90 ug/min TLV
0.002 ppm (TWA) 0.1 ppm
Total Dust TLV
.002 mg/m
* TLV (Threshold Limit Value) and PEL (Permissible Exposure Level) respectively set by American Conference of Government Industrial Hygienists and by Occupational Safety and Health Administration. These levels are considered maximum exposure permitted to ensure no health hazard. TWA (Time­Weighted Average) for a normal eight-hour workday.
3
10 mg/m
3
All measurements were made on products performing within established operating specifications and received recommended maintenance procedures. Xerox certifies that this product meets or exceeds the applicable standards for safety and emissions.