XENOX MV9 User Manual

(r?xEnrox
MV9
Manual
D
GB
F
I
E
NL
DK
S
cz
TR
Fig.
1
Fig. 2
Fig. 3
@
XENOX MV9
Note:
-
metal and voltage
detector
Dear Customer, Before using the detector, please read the
attached operating instructions.
Legend (see Fig. 1)
1.
LED display for metal detection or
voltage detection Adjuster wheel for switching on and
2. adjusting detector
3.
Metal detection (M) and voltage detection
4.
Battery compartment cover
Sensor unit for metal detection and
5. voltage detection
6.
Audio signal
(v)
selector switch
During adjustment, hold the device in the position (vertical or horizontal) in which the wail is to be scanned.
Hold the detector as you would for wall scanning.
1. Set the selector switch to metal detection or detection 3 (Fig. 1).
2. Switch on the detector using adjuster wheel 2 (Fig. 1).
If the detector is set to intermittent audio signal will sound briefly and then stop.
3. Rotate the adjuster wheel until LED 1
(Fig. 1) illuminates and the audio signal sounds (Setting M = continuous audio signal, setting V = intermittent audio signal)
4. Slowly rotate the adjuster wheel in the
reverse direction until the audio signal stops and the LED extinguishes.
“V”
‘IV”,
“M”
for
for voltage
an immediate
Inserting and replacing battery
1. Open battery compartment 4 (Fig.
2. Connect battery; do not to transpose the positive and negative terminals.
3. Replace battery compartment cover.
Detectina metal or
The sensitivity of the detector must be
reset before each use.
When resetting the detector, make sure that there are no metal components
(wristwatches) or current-carrying wires within a one-metre radius.
voltaae
I).
Note:
The less the adjuster wheel is rotated in the reverse direction, the more sensitive the setting and the greater the
penetration depth become (required
especially for flat-webbed house wire).
5. Slide the detector slowly and uniformly in a horizontal motion over the wall surface (Fig. 2).
Note-
4
Due to incorrect use or unfavourable environmental influences, it is possible that metal or electrical conductors will not be properly detected. The manufacturer cannot therefore guarantee certainty of detection.
Note-
-
The sensitivity of the detector can be
reduced further for precise localisation. Slightly rotate the adjuster wheel after the diode illuminates until the diode extinguishes. Then proceed with metal detection. For testing purposes, it is best
to select an exposed metal section or
electric cable.
Imnortant!
Jerky movements can cause the detector to react with a positive illumination response even though no metal or
voltage is present.
If lines are routed beneath reflecting materials (aluminium-coated insulating materials), system-based technical problems occur in the
“V”
setting.
There is no display response if the walls
are very wet, since it is impossible for an
electrical field to build up. There is no detection of telephone lines
or other signal lines.
4. When finished using the detector, switch it off using adjuster wheel 2 (Fig. 1) to preserve the battery.
Readjusting the detector
Fluctuations in temperature, voltage and air humidity may cause the LED or audio signal to fail to respond in the
“M”
setting
after the detector has been switched on.
Insert a charged battery.
2. Set selector switch 3 (Fig. 3) to setting
“M”.
3. Completely rotate the adjuster wheel (Fig. 3) to the limit stop and then in the reverse direction by
l/2
the number of
rotations.
4. Adjust the potentiometer (2) using a small screwdriver 4, (supplied in housing) so that the display illuminates.
5. For testing purposes, slightly rotate the adjuster wheel (1) in the reverse direction. The LED must extinguish.
6. Reassemble the housing.
The detector is now ready again for
operation.
EC declaration of conformity
We declare and are solely responsible for
guaranteeing that this product complies
with the following EC guidelines:
l
EC EMC Guideline 89/336
/K$C&S?/
Dipl. Ing. Martin
FaObender
Equipment Safety Division
In such cases, if the cause is not attributable to the battery, the detector must be adjusted.
1. Open the detector. Reach into the battery compartment and separate the two halves of the housing.
Note-
L
When adjusting the detector, ensure that there are no metal parts or
current-
carrying lines in the vicinity.
Unsere Erzeugnisse werden
nach
der
Fertigung
Stuck Mr Stuck
noch
einmal
tiberprtift.
Sollte
dennoch ein Defekt
auftreten, wenden
Sie
sich
bitte an:
XENOX-Zentralservice
Im
Spanischen 18-24
D-54518 Niersbach/Eifel
Bei
der
Rucksendung
von defekten
Geraten
innerhalb der
Garantiezeit (6 Monate) ist unbedingt der Kaufbeleg (oder eine
Kopie dieses Beleges)
beizuftigen.
Eine genaue Beschreibung des
aufgetretenen Defektes erfeichtert uns die Reparatur.
Sendung
bitte
ordentlich frankieren. Die Annahme von
ungenij-
gend frankierten Sendungen mu8 leider verweigert werden. Wir bitten urn Ihr Verstandnis.
jinderungen
im Sinne des technischen Fortschritts behalten wir uns vor.
Loading...