![](/html/fb/fbb7/fbb7be42a5282615cd253165ac1dea7e9a54743f8d2db131799ececede23f68b/bg1.png)
IFU ACTIVESOL FLEX en 10 17 V.3.
USER MANUAL
FLEXIBLE PHOTOVOLTAIC MODULES
ACTIVESOL LIGHT & ACTIVESOL ULTRA
This manual includes information regarding safety and guidelines regarding the ACTIVESOL flexible photovoltaic
modules system manufactured by XDISC S.A.
It is necessary to get acquainted with this manual prior to the installation, operation and maintenance of the modules.
Non-compliance with the manual entries may result in the destruction of property, body injuries or, in extreme cases,
in death.
LIMITED RESPONS IB ILITY
XDISC S.A. does not have any say in terms of the method of installation, operation and use of the ACTIVESOL flexible
modules. Due to the above, XDISC is not responsible for any losses, damage and costs resulting from incorrect
installation, operation and use of the modules.
IN T ENDED USE
The ACTIVESOL LIGHT & ULTRA are flexible photovoltaic modules for creating autonomous (off-grid) power supply
systems.
GE N ERAL RECOMMEND A T I ONS
All electrical systems must be executed according to the current legal regulations
It is necessary to verify the technical condition of the module prior to installation
The modules should be installed by a qualified personnel
It is forbidden to connect power receivers directly to the photovoltaic module
The total voltage of the system, the basis of which consists of the ACTIVESOL LIGHT & ULTRA modules, should
not exceed 1,000 VDC.
In real conditions, the photovoltaic modules may generate more current or more voltage than in the standard
testing conditions. Due to safety reasons, during the system designing, it is necessary to consider increased
rated values of the ACTIVESOL LIGHT & ULTRA modules; short-circuit current (Isc) and open circuit voltage
(Uoc), by multiplying them by the 1.25 coefficient.
![](/html/fb/fbb7/fbb7be42a5282615cd253165ac1dea7e9a54743f8d2db131799ececede23f68b/bg2.png)
IFU ACTIVESOL FLEX en 10 17 V.3.
do not install the modules
near sources of heat and
combustible materials
during the installation and
disassembly of the module, cover
the module with material which
keeps the light out
install and disassemble in dry
conditions
do not load the modules with
tools or objects which may
scratch the module’s surface
and damage the cells
do not stand and walk on the
module if it is not placed on
a flat and fine surface,
without visible faults,
elevations and curves
DANGER
Take care! Contact with live module parts may cause sparks and low-intensity electrical discharges.
DANGER
Photovoltaic module exposed to sunlight or other source of light generates power. The voltage generated
by a single module does not constitute a hazard. During the connection of several photovoltaic modules,
the accumulated voltage or the intensity of the generated current may be high and constitute a hazard for
health and life.
PR ECAUT I O N S
When working with the photovoltaic modules, it is necessary to use the recommended precautions.
Long-term load of the panels, incorrect transport and excess in the maximum bending radius may cause microcracks which may result in hot-spots.
The photovoltaic module must be stored in its original packaging until installation.
The modules may not be bent or folded. Do not bend the module excessively. This may cause permanent
damage to the cells. The module’s bending radius is 5 m.
It is necessary to keep the modules in a horizontal position when moved, hold them by their top edge and
do not put pressure on the cells.
It is forbidden to stand and walk on the module if it is not placed on a flat and fine surface, without visible
faults, elevations and curves.
Do not puncture the module, even at spots that are distant from the cells.
Do not move the module by holding it by the connection cables.
Do not disassemble or modify the module parts.