Xantech YiAK-K1000-01A User Manual

KP 1 In-Wall Keypad
Power for the Digital Revolution
Decora is a registered trademark of Leviton Manufacturing Company, Inc. Micro Link is a trademark and Xantech is a registered trademark of Xantech Corporation. Harman Kardon is a registered trademark,and Power for the Digital Revolution is a trademark, of Harman Kardon, Inc.
250 Crossways Park Drive,Woodbury, New York 11797 1-800/422-8027 (USA only) Fax:516/682-3523
©2001 Harman Kardon,Incorporated
Printed 9/01 Part No.YiAK-K1000-01A
Introduction
Congratulations! As the owner of a KP 1 in-wall keypad, you own an
accessory that adds convenience and versatility to your home audio system by providing independent control in each room or zone powered by a Harman Kardon PA4000 multichannel power amplifier.The elegant,three­button design offers power on/off and volume control and is prewired to accept an optional infrared (IR) sensor to allow remote control of virtually any device equipped with a remote IR input.
The KP 1 uses an optional Decora
®
-style cover plate for coordination with other wall-mounted switches.The KP 1 does not require an external power supply,as all needed power is provided through the connection to the PA4000.
In order to fully enjoy the benefits of remote keypad control,please take a few minutes to read this owners guide. It contains important information that will guide you step by step through the correct and safe installation of your keypad.If you do not have experience installing in-wall electrical and telecommunications components,we recommend that you have the KP 1 installed by a properly trained professional.
If you have any questions about this product, its installation or its operation, please contact your retailer or custom installer. They are your best source of product information.
Features
Elegant,Three-Button Design
Up to Four KP 1 Keypads May Be Attached to the PA 4000 for
Independent Control of Separate Rooms and Zones
Accepts Optional IR Sensor That Transmits Commands to Most
Remote-Controllable Products Through a PA 4000
Designed for Use With Optional Decora-Style Wall-Plate That
Blends in With Other In-Wall Electrical Components
Mounts in Standard Electrical Junction Box or With Plaster Ring
RJ-45 Connector Offers Easy Installation With PA 4000 Amplifier
3-Pin Eurostyle Connector for Optional IR Sensor
Typographical Conventions
In order to help you use this guide with the front panel controls and rear panel connec­tions for both the KP 1 and PA 4000,certain conventions have been used.
Example – indicates a specific front panel button or rear panel connection jack 1 – indicates a KP 1 front panel control or feature ¡ – indicates a KP 1 rear panel connection or feature a – indicates a PA 4000 rear panel connection or switch
Important Safety and Installation Information!
Wire Separations
Low-voltage control wiring systems must always be installed to minimize the possibility of accidental contact with wiring carrying hazardous voltage.Never place any wiring near bare power wires or lightning rods,antennas, transformers, steam or hot water pipes,or heating ducts. Never place a wire in a conduit, box, channel, duct or other enclosure containing power or lighting control circuits of any type.Always provide ade­quate separation of control or audio/video wiring and other electrical wiring according to code.When in doubt about separation distances,the Rule of Sixescan be used. This rule requires six feet of separation between low-voltage control wiring and open high-voltage wiring, lightning grounding wire or grounding rods. It requires six inches of separation from all other high-voltage wiring unless either the power or control lines are inside a conduit.
Cutting and Drilling
Always observe all applicable safety rules when installing any wires.Be extremely care­ful not to cut through or drill into concealed wiring or pipes.
Splicing
Common wire-splicing techniques may cause wire to break, resulting in poor circuit integrity.This can cause interference in the form of static,noise or poor component performance.
Clean Contacts
Dust or dirt can cause special problems on contacts.Be sure all contacts are clean and that all parts are installed correctly to protect them from dust and dirt.
The KP 1 in-wall keypad has been custom-designed for use with the PA 4000 amplifier. Do not connect it to any other device.
Make sure to follow all instructions when preparing wiring for use with the KP 1 keypad.Failure to do so may result in a potential safety hazard, including possible danger to persons and/or equipment.
If you will be running cable through a plenum, remember to use P-rated cable to comply with your local building codes and the NEC.Failure to do so may result in a potential fire or safety hazard.
The KP 1 should be installed only by qualified personnel.Always be sure that any wiring inside walls is installed in compliance with the NEC,or as required by the applicable state,county and/or municipal building code. Failure to do so may pres­ent a potential safety hazard.
If you have any doubt about your ability to work with electrical and telecommuni­cations wiring, you are advised to hire a qualified professional custom installer to install this product.
For additional safety instructions,see the Harman Kardon PA 4000 owners manual.
Installation Location
The KP 1 in-wall keypad can be installed in any location appropriate for standard in­wall electrical components.You are responsible for selecting and properly installing an appropriate electrical junction box or plaster ring. Be sure to check the fit of the box or ring with the KP 1 before installation into your wall. If you plan on installing an optional IR sensor, be sure to avoid installing the KP 1 in an area subject to potential interference with the IR signal. Possible sources of interference include fluorescent lighting, neon lighting, dimmer-controlled lighting, plasma-panel video displays,natural light sources,and reflective surfaces such as mirrors or blank walls.You may wish to temporarily place the component to be controlled using the sensor in the proposed location prior to starting the installation in order to test the integrity of IR signals. Be sure to install the KP 1 keypad with the IR Sensor Cutout 5 at the bottom in order to avoid potential interference from the buttons when IR signals are transmitted from a seated position.
What Is Included
Your KP 1 in-wall keypad includes two mounting screws: 1/8" x 3/4" self-starting, universal-head machine screws.
What You Must Supply
You are responsible for providing a Decora-style cover-plate,which will also include the screws that secure it to the KP 1.
You are also responsible for providing a sufficient length of 24AWG,8-conductor, CM- or CP-rated Category 3 or Category 5 UTP (unshielded twisted pair) wire and RJ-45 modular plugs.The wiring scheme must be Straight Through (standard T568B) and not crossed over as is done for telephone or data connections.The maximum length should not exceed 250 feet in order to avoid degradation of the signal.Further information on the correct wiring configuration is provided below.
Should you wish to use an optional IR sensor, Harman Kardon recommends using the Xantech®model 490-00 Micro Link™sensor, which measures 1/2" (13mm) in diameter by 2" (51mm) deep,and includes a 7-foot, 3-conductor cable with pin assignments for +12 Volts, Signal and Ground.Any similar,compatible sensor may be used instead.
Front Panel Controls
1 Cover Plate Screwholes — After you have completed installation,these screw- holes accept the screws supplied with your Decora-style cover plate to attach it to the KP 1.
2 Mounting Screw Slots — Use the supplied machine screws to attach the KP 1 to an electrical junction box or plaster ring using these slots.
3 Power Button – When the KP 1 is connected to a properly configured PA 4000, gently pressing and releasing this button signals the PA 4000 to turn the channel(s) controlled by that KP 1 on or off,depending on its last state.
4 Volume ▲/▼Buttons – Press these buttons to raise or lower the level of the speakers connected to the channel(s) controlled by the KP 1 in use.
5 IR Sensor Cutout – If you will be installing an optional IR sensor, punch out this cutout. See the detailed installation instructions in the next section.
1
2
Power
Volume
3
4
5
2
1
Loading...
+ 3 hidden pages