INSTALLATION INSTRUCTIONS
792-10
POWER MODULE
The 792-10 is a multipurpose device designed for use in the following applications:
1. As an output amplifier and power source to convert Xantech 3-wire IR Receivers to 2-wire PHANTOM POWER operation.
IR IN
GND
+12V
IR OUT
2. As an output amplifier for any Xantech IR Receiver or Controller to drive large numbers of emitters when plugged into one or more 790-00 passive Connecting
Fig.1 792-10 Power Module
Blocks.
FEATURES AND SPECIFICATIONS
• Phantom Power and/or Current booster modes.
• Phantom mode powers the 291-10, 480-00, 490 and 780-10 series IR receivers for 2-wire operation.
• Screw terminals provide for wired input connections.
• 3.5 mm mono mini jack emitter IR OUT port.
• Low current mode drives up to 4 emitters in series.
• High current mode drives up to 100 emitters in parallel through 790-00 Connecting Blocks.
• Maximum peak output current - Low Current mode: 100 mA.
• Maximum peak output current - High Current mode: 1 A.
• 2.1mm coaxial DC power jack (+12V).
• Requires a 781RG or a 782-00 power supply.
• Dimensions: 3-5/8" L x 1-5/8" W x 1" D.
792-10
POWER MODULE
ON
1 2 3 4 5 6 7 8 910
12345678910
®
1 (ON) 0 (OFF)
+12V
IR OUT
Modules & Connecting Blocks
GENERAL
The input and output parameters for setting Normal 3-wire, Phantom 2-wire and Output Current modes are configured by setting the DIP switches. These switches are accessible through the slot in the case.
• In the Normal 3-Wire mode, +12V is applied to Xantech IR Receivers and Keypads on a third wire in the same manner as on Xantech Connecting Blocks.
• In the Phantom 2-Wire mode, +12V is applied to the IR Receivers on the same wire that carries the IR control signal.
PLEASE NOTE:
The Xantech Smart Pads and the CFL Friendly IR receivers, will not operate with
the 2-wire Phantom Power connection!
• In the Low Current mode, the 792-10 IR OUT jack will drive a single or dual emitter or connecting blocks in the same manner as an IR receiver.
• In the High Current mode the 792-10 IR OUT jack will drive up to 10 Model 790-00 Connecting Blocks, each having up to ten emitters connected to it.
CAUTION:
Do not plug single or dual emitters into the IR OUT jack when the 792-10 dip switches
are set to the High Current mode. To do so will destroy emitters!
1
INSTALLATION
Set the DIP switches to the desired mode, using the chart below. Check your settings carefully to be sure they are correct.
NOTE:
Do not connect the power supply until all switches are set & all other connections are made.
DIP SWITCH SETTINGS
INPUT MODE
OUTPUT MODE
123456789
NORMAL 3-WIRE
PHANTOM 2-WIRE
LOW CURRENT HIGH CURRENT LOW CURRENT HIGH CURRENT
1100000000 1100000111 0010000000 0010000111
Fig. 2 DIP Switch Setting Chart
SWITCHES
780-10
J-Box IR Receiver
10
Use jumper wire between IR OUT and GND screws as shown
780-10
J-BOX RECEIVER
XANTECH CORPORATION
+12V
IR OUT
GND
REMOTE ROOM
2-Conductor Inter-room Cable (usually coax)
Shield
Power Module
High Current Mode)
792-10
(In Phantom
792-10
IR IN
POWER MODULE
ON
GND
1 2 3 4 5 6 7 8 910
+12V
12345678910
IR OUT
1 (ON) 0 (OFF)
®
Power Supply
+12V
IR OUT
781RG
MAIN ROOM
IN / OUT
IN / OUT
SIGNAL
GROUND
MODEL 790
CONNECTING BLOCK
XANTECH CORPORATION
790-00
Connecting Block
To
282M or 283M
EMITTERS
Emitters on
controlled
equipment
Fig.3 A Basic Phantom Powered System
Phantom Power Connections
Some existing installations may have only 2 wires (such as coax) going to a remote room. Fig. 3 illustrates Phantom Power connections in a basic system:
• Although a 780-10 is shown, other Xantech 3-wire IR Receivers may be used.
• In each case, the OUTPUT and GND leads of
IR OUT
IR OUT
+12V
+12V
781RG
Power Supply
White Striped Side
6015900 cables (3.5mm-to­stripped ends)
MAIN ROOM
IN / OUT
IN / OUT
SIGNAL
GROUND
MODEL 790
CONNECTING BLOCK
XANTECH CORPORATION
790-00
Connecting Block
To
282M or 283M
EMITTERS
Emitters on
controlled
equipment
the IR receiver are jumpered together and connected, through the inter-room cable, to the GND terminal of the 792. The +12V lead is connected to the IN terminal of the 792.
• Additional 780's or other Xantech IR Receiv­ers may be wired in parallel at the IN and GND terminals of the 792, up to a maximum of three. More than this may cause unreliable
From Phantom Connected IR Receivers in Remote Rooms
792-10
IR IN
POWER MODULE
ON
GND
1 (ON) 0 (OFF)
1 2 3 4 5 6 7 8 910
+12V
12345678910
IR OUT
®
792-10
IR IN
POWER MODULE
ON
GND
1 (ON) 0 (OFF)
1 2 3 4 5 6 7 8 910
+12V
12345678910
IR OUT
®
Fig.4 Using Additional 792-10's
results.
• If you have more than three IR receivers, connect additional 792-10's as shown in Fig. 4
NOTE: Phantom power mode is not recommended unless faced with an existing coax or other 2-wire situation. For new construction, always pull three wires and use the normal 3-wire connections for best IR operation.
Multiple-Emitter High Current Operation
The high current output capability of the 792-10 allows up to 100 single or 100 dual emitters to be driven. Fig. 5 illustrates the necessary connec-
Connect to additional
790's in the same
manner, up to a maximum of 10,
as needed.
To Emitters on Controlled Equipment
IN / OUT
EMITTERS
SIGNAL
SIG
GROUND
GND
MODEL 790
CONNECTING BLOCK
XANTECH CORPORATION
Connecting Blocks
IN / OUT
790-00
To
Emitters on Controlled Equipment
IN / OUT
EMITTERS
SIGNAL
SIG
GROUND
GND
MODEL 790
CONNECTING BLOCK
XANTECH CORPORATION
IN / OUT
tions:
• The IR OUT jack of the 792-10 is connected to multiple 790-00 Connecting Blocks as shown. (The output of the 792-10 is also available between the IR OUT and GND screw termi­nals, in the event a wired connection is needed.)
• Set the DIP switches to the 3-Wire High Cur-
780-10
J-Box IR Receiver (or other Xantech 3-wire IR Receiver
or Keypad)
Fig.5 Driving Multiple-Emitters in High Current Mode
XANTECH CORPORATION
+12V
IR OUT
GND
780-10
J-BOX RECEIVER
3-Conductor Cable
792-10
Power Module (In 3-Wire High Current Mode)
IR IN
POWER MODULE
ON
GND
1 2 3 4 5 6 7 8 910
+12V
12345678910
IR OUT
792-10
To 120 VAC (unswitched)
782-00
High Current
1 (ON)
+12V
0 (OFF)
IR OUT
®
Power Supply
rent mode. Refer to Fig 2.
• A high current power supply, model 782-00, is used to supply the high peak currents required. MOUNTING - Holes are provided in the end flanges of the 792-10 for mounting. Use the 2 screws provided
to secure it to any flat surface. NOTE: With any of these systems, be sure the power supply is plugged into an un-switched AC outlet. This
maintains the IR system in "standby" operation so that power-on commands can be sent to the controlled equipment.
2