Xantech 590-00 User Manual

INSTALLATION INSTRUCTIONS
590-00
PROGRAMMABLE CONTROLLER
590
PROGRAMMABLE CONTROLLER
FRONT PANEL
The front panel of the 590 is made of acrylic plastic. It should be cleaned with a soft cloth as it scratches easily. Behind the panel are five red LEDs and an infrared sensor.
RED LEDs
ERROR - Lights when an error occurs in the learning process or when trying to send an unprogrammed command.
PROGRAM - Lights when the PGM (program) button on the rear panel is pressed. CONFIRM - Lights after a command has been memorized during programming. DELETE - Blinks on and off when the DELETE button on the rear panel is pressed. OUTPUT - Lights to indicate when infrared commands are being sent in response to a contact
closure. Contact closure is the most common form of input to the 590. If other types of inputs are used, they will perform the same function as contact closures.
INFRARED SENSOR
Receives IR commands for programming the 590. It is located about one-half inch above the OUTPUT lamp.
PROG
ERROR
CONFIRM
RAM
DELETE
O
UTPUT
Infrared Sensor
Controllers
+
1
2 3 4 5 6 7 8 9 10 11 14 15 16 O G – +12 13
RES DEL SEQ PGM
12VDC
ON
1234
1234
BANK
12VDC
REAR PANEL
The following connectors, push-buttons and controls are located on the rear panel:
12VDC jack – the power supply plugs in here (center conductor is positive). BUTTONS (Recessed - press with a pencil point or narrow blade screw driver).
RES - Reset - erases all stored commands. DEL - Delete - allows erasure of selected commands. SEQ - Sequence - begins and ends sequence mode programming. PGM - Program - begins and ends learning mode.
BANK - Bank DIP Switch – Selects one of four memory banks on microprocessor.
1
1
12VDC
12VDC
1234
BANK
RES DEL SEQ PGM
+
234567891011 141516OG
–+
12 13
Emitter, Connecting Block, etc.
120 V AC
Unswitched
786-00
Power Supply
White Striped Side (output)
C 1 2 3 4 5 6 7 8
C 1 2 3 4 5 6 7 8
Wire size typically AWG 20-24
Model 590
(rear panel)
Model 598
Key Pad
(rear view)
ON
Ground or "–" return wires. See Step 3 under "PROGRAMMING"
+12V DC
SCREW TERMINALS
Opto-Isolator Inputs - 16 pairs of positive and negative terminals, isolated from ground. O - Infrared Output - Positive terminal for the IR output signal. G - Ground - Negative terminal for the IR output signal.
The "O" and "G" terminals drive IR emitters directly or the IR input of Xantech connecting blocks, IR routers, interface modules, etc.
12VDC - 12 volts output, positive & negative terminals.
INPUTS
A decision as to the type of external input(s) must be made. Figs. 1 & 2 show some examples. The LED inside each opto-isolator within the 590 must pass current in order for the unit to recognize an input. This is accomplished by applying a momentary 5 to 30 volts DC input to these 16 circuits. While many types of switch closures to do this are possible, we will discuss only one for simplicity, the Model 598 key pad. Fig. 1 shows the 598 providing contact closures to activate 8 of the 16 opto-isolator inputs.
OUTPUT
The "O" and "G" terminals on the rear panel will drive IR emitters direct or the SIGNAL IN of Xantech connecting blocks, controllers, etc. If a single model 282, 283, 284 or 286 Mini-Emitter(s) is to be used, cut
Fig. 1 Typical connections when using a 598 Keypad with a
590 Programmable Controller.
off the plug, strip the leads, and connect the wire with the white stripe to "O" and the black wire to "G". For the connection of more emitters, use Xantech Connecting Blocks model 789-44 or 791-44. In this case, connect the "O" and "G" terminals to the "INPUT" and "GROUND", respectively, on the Connecting Blocks.
The 590 output circuit has the same electrical characteristics as the infrared receivers and key pads in Xantech’s broad line of remote control extension systems and therefore can be wired as part of a larger system.
TURN IT ON
Plug the power supply into the 12VDC jack on the 590 then plug it into a wall outlet. The five red LEDs (ERROR, PROGRAM, CONFIRM, DELETE and OUTPUT) on the front of the 590 should be off. If any of them are on, unplug the power supply from the wall, wait 10 to 15 seconds and plug it in again. Repeat this process until all of the lamps are off.
PROGRAMMING
Before programming the 590, press the RES (reset) button on the rear panel. This will clear any data stored during factory testing. Do not push this button again unless you wish to erase ALL of the programming information which you have entered. There is no way to restore this information except by reprogramming.
NOTE: FOR THE SAKE OF CLARITY, EXTERNAL CONTACT CLOSURES WILL BE REFERRED TO AS "KEYS" THROUGHOUT THIS MANUAL (whether made with a push-button +12V DC terminal and held to the + terminal of the desired input. Refer to step 3 following).
Programming Procedure:
1. Press the PGM (program) button on the rear panel. The PROGRAM lamp on the front panel will light.
2. Place the "teaching" hand-held remote control two to four inches in front of the 590. Point it directly
at the internal Infrared Sensor (located just above the OUTPUT LED on the 590's front panel).
2
or a wire connected to the
590-00
Loading...