Xantech 490-95 User Manual

INSTALLATION INSTRUCTIONS
MODEL 490-95
MICRO LINK™ “PLASMA FRIENDLY” INFRARED RECEIVER
TABLE OF CONTENTS
INTRODUCTION ............................................................................................................................................................. 1
Features ...................................................................................................................................................................... 1
Specifications .............................................................................................................................................................. 1
INSTALLATION ............................................................................................................................................................... 2
Mounting...................................................................................................................................................................... 2
Application Wiring........................................................................................................................................................ 3
Advanced Wiring Configuration.................................................................................................................................... 3
3.5mm Mini Plug Pinout ............................................................................................................................................... 4
INTRODUCTION
The 490-95 is designed to reject interference from Plasma Displays from entering the IR signal line. These Small IR Receivers are intended to be mounted in panels, doors, cabinets, etc. for control of A/V equipment behind closed doors or any IR Repeater System that is in close proximity of a Plasma or LCD Displays. Modeled after the original 490-90, the 490-95 offers the same features as its predecessor but in a smaller mounting frame.
FEATURES
Small size; mounts in ¾” diameter hole. 2¾ inches deep (70mm)
Quick-Connect 3.5mm Stereo Mini Plug on 7ft. (213.36cm) cable for direct plug-in to Xantech Connecting Blocks
Works in normal 3-wire mode (12VDC, IR, GND)
Green Talkback LED for System Verification
Improved Fluorescent Light rejection (under most conditions) and rejection from LCD Displays
Can be used in Direct Sunlight
RF Grid included for EMI interference reduction
Includes CB12 Connecting Block for easy connection and extension of 7' ribbon cable
7 units may be powered by one 781RG power supply
Note: The 490-95 will not operate in 2-wire Phantom Power mode
SPECIFICATIONS
Infrared modulation frequency bandwidth: 30 - 100 kHz
Reception range: up to 55 feet (17M), depending on local conditions
Reception angle: 55 degrees off axis for 50% range reduction
Cable requirements: 3-conductor. Use 24 gauge up to 200' (61M), 22 gauge up to 600' (182.5M), 20 gauge up to 1000' (305M), 18 gauge up to 2000' (610KM) -- unshielded OK)
Maximum transmission length: One mile using 18 gauge wire (1.6KM)
Maximum current output: 100 mA
Dimensions: 0.75" diameter x 2.75" deep (19mm x 70mm)
Power requirements: 12 volts DC @ 20 mA
Page 2 Model 490-95
INSTALLATION
These units, equipped with a 7-foot cable and 3.5 mm stereo mini plug, are intended to be plugged directly into the "IR RCVR" or "AUX" jack on Xantech Connecting Blocks, such as the CB12(included), CB60, 789-44, 791-44, etc. The 490­95 should be used in installations where the connecting block is within reach of the 7-foot cable -- such as when installing the 490-95 in a cabinet where the controlled equipment is behind closed doors.
PLACEMENT
Placement of the IR Receiver does matter when used in the presence of a Plasma Display. Ideally it should be placed at areas around the Display with the front of the receiver flush with the front of (or
45°
PLASMA DISPLAY
45°
set back from) the Display. If the 490-95 needs to be placed in front of the display (such as on an adjacent side wall perpendicular to the display), make sure it is placed at a location at least 45 degrees off axis from the corners of the unit – see Figure 1. The presence of Direct Sunlight and Fluorescent Lighting should not effect the reception of this unit.
Figure 1 – 490-95 Placement
Note: Plasma interference can be reflected off of any item it comes into contact with within approx. 3 ft. from the front of
the display. Keeping this in mind, make sure that the 490-95 is free of any obstruction that might reflect back into the receiving eye. Note: While this unit shows strong rejection to standard 50/60Hz ‘ballasted’ fluorescent lighting, it is still prone to interference from CFL style Fluorescent lighting.
MOUNTING
1. Drill a 0.75” (19mm) hole in any flat surface, such as a cabinet panel.
2. Pass the lead and the body of the 490-95 through the hole.
3. Secure from the rear with the Washer and Nut (all supplied) as shown in Figure 2a. Be sure not to over-tighten
nut.
1.25
0.90
2.75
0.75
Figure 2a – 490-95 Features Figure 2b – 490-95 Dimensions
© 2004 Xantech Corporation
Model 490-95 Page 3
APPLICATION WIRING
A typical system, with a 490-95, 781RG Power Supply and 283M Emitter plugged into a 789-44 Connecting Block, is shown in Figure 3:
1. Plug in the 2.1mm Coaxial power plug of the 781RG Power Supply (not included) into the jack labeled 12VDC on
the 789-44 Connecting Block.
2. Plug the AC end of the 781RG power Supply into an ‘un-switched’ 120v AC Line outlet.
3. Plug the 3.5mm stereo mini plug from the 490-95 into the IR RCVR input on the 789-44 Connecting Block
4. Plug in the Emitters 3.5mm mono mini plug such as any of the 282, 284, 283 and 286 series into the jacks labeled
EMITTERS on the 789-44 and affix the opposite end to the IR Sensor Window of the controlled equipment.
490-95
Micro Link
Plasma-Friendly
IR Receiver
Hand Held
Remote
781RG
Power Supply
To 120 V AC (unswitched)
789-44
Connecting Block
12VDC
+12 VDC
GND
STATUS
IR IN
RCVR
IR
CONNECTING BLOCK
EMITTERS
789-44
®
Equipment Rack
Satellite Receiver
283M
Emitter
VCR
283M
Receiver
AV
283M
Blink-IR
Mouse Emitter
Emitter
Figure 3 - Typical System Layout using 490-95, 789-44, 781RG, and 283M Emitters
ADVANCED WIRING CONFIGURATION
490-95 may also be used where the 7-foot lead is not long enough. In this case, simply use the CB12 Connecting Block as a “break-out” block. In Figure 4, a 490-95 is extended down to a 789-44 Connecting Block and combined with other Xantech IR Receivers.
1. Plug the 3.5mm stereo mini plug from the 490-95 into the IR RCVR input on the CB12 Connecting Block.
2. Using 3-Conductor wire (refer to Specifications section for proper W ire Gauge) connect the terminals labeled V
G S of the CB12 to the terminals labeled +12VDC, GND, and IR IN on the 789-44 Connecting Block (or other)
3. Plug in the 2.1mm Coaxial power plug of the 781RG (or 782) Power Supply (not included) into the jack labeled
PWR on the 789-44CB.
CAUTION! Do not
plug in a 781RG or any other Power Supply into the CB12 when using in a “break-out” configuration. This will put 2 supplies in parallel and possibly damage your equipment. If a ‘local’ emitter is needed on the CB12, see Step 5 below.
4. Plug in the Emitters 3.5mm mono mini plug such as any of the 282, 284, 283 and 286 series into the Emitter
Outputs on the 789-44.
© 2004 Xantech Corporation
Page 4 Model 490-95
Hand Held
Remote
(See Text)
X X
OUT
RCVR
IR
VGS
PWR
CB12
Connecting
ROOM 2
Block
490-95
Plasma-Friendly IR Receiver
3-Conductor Room-to-Room Cable
24 to 18 gauge (unshielded OK)
+12V
IR OUT
GND
ROOM 3
®
+12 VDC
IR OUT
GND
+12V
780-10
J-BOX RECEIVER
IR Receiver
GND
IR OUT
780-10
J-Box
Smart Pad
GND
782-00
Power
Supply
291-10
IR Receiver
+12V
IR OUT
789-44
Connecting Block
12VDC
+12 VDC
GND
STATUS
IR IN
RCVR
IR
ROOM 4
3-Wire Cable
Red Stripe
To 120 V AC (unswitched)
CONNECTING BLOCK
789-44
EMITTERS
®
480-00
Dinky Link
IR Receiver
Satellite Receiver
282M
Mouse Emitter
VCR
282M
Emitter
AV
Receiver
283M
Blink IR Emitter
286M
Dual Blink IRs
(to other
controlled
devices)
MAIN ROOM 1, EQUIPMENT CABINET, ETC.
Figure 4 - Advanced Wiring Configuration using 490-95, CB12, 789-44, 781RG and multiple 286M’s
5. If a local Emitter is needed on the CB12, you will need to place a 470 Ohm Resistor in Series with the Signal
Output on the CB12. To Wire in this fashion:
a. Cut a standard Mouse Emitter (282M or 283M) approximately 12inches from the 3.5mm Mono Mini Jack.
You will now have 2 cables; one with a 3.5mm Mono Mini Jack and one with the Mouse Emitter. b. Wire the 2 leads of the Mono Mini Jack side to a terminal Strip. c. On the Terminal Strip, opposite the lead with the W hite Stripe (Signal) connect one side of the 470 Ohm
Resistor. d. Wire the other side of the resistor to the lead with the White Stripe on the Mouse Emitter. e. Connect the Black Wire of the Mouse Emitter to the Terminal Strip opposite the Black Wire (GND) from
the 3.5mm Mono Mini Jack.
This will keep the proper load balance and prevent miscommunication with the Emitters on the 789-44 CB.
3.5MM MINI PLUG PINOUT
There might be times when the 490-95 needs to be wired directly to a Terminal Block. In that case you will need to cut off the 3.5mm jack and wire according to Table 1.
Table 1 - 490-95 Connector Pin-Out
PLUG CABLE LEADS CIRCUIT ITEM
TIP WHITE IR OUT
RING BLACK GROUND
SLEEVE RED +12V
CAUTION: W ith any of these systems, be sure the 781-RG Power Supply is plugged into an un-switched AC outlet. This maintains the 490 system in "stand-by" operation so that power-on commands can be sent to the controlled equipment.
XANTECH CORPORATION
13100 Telfair Avenue, Sylmar CA 91342-3829
phone 818.362.0353 • fax 818.362.9506
Part No. 08901485 Rev A 07-22-04
© 2004 Xantech Corporation
Loading...